Bradford-White Corp MAGNUM Series Commercial Electric Booster manual
- Consulta online o descarga el manual de instrucciones
- 28 páginas
- 0.89 mb
Ir a la página of
manuales de instrucciones parecidos
-
Water Heater
Bradford-White Corp U1TW40S*FRN
52 páginas 2.71 mb -
Water Heater
Bradford-White Corp M4TW50T*F
40 páginas 2.83 mb -
Water Heater
Bradford-White Corp MI303T*F(BN
28 páginas 1.4 mb -
Water Heater
Bradford-White Corp BMT2V
40 páginas 2.7 mb -
Water Heater
Bradford-White Corp PDV80S150
52 páginas 3.21 mb -
Water Heater
Bradford-White Corp CX
28 páginas 3.31 mb -
Water Heater
Bradford-White Corp 07.05.228.00
28 páginas 0.89 mb -
Water Heater
Bradford-White Corp U4TW50T*FRN
52 páginas 4.09 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Bradford-White Corp MAGNUM Series Commercial Electric Booster. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Bradford-White Corp MAGNUM Series Commercial Electric Booster o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Bradford-White Corp MAGNUM Series Commercial Electric Booster se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Bradford-White Corp MAGNUM Series Commercial Electric Booster, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Bradford-White Corp MAGNUM Series Commercial Electric Booster debe contener:
- información acerca de las especificaciones técnicas del dispositivo Bradford-White Corp MAGNUM Series Commercial Electric Booster
- nombre de fabricante y año de fabricación del dispositivo Bradford-White Corp MAGNUM Series Commercial Electric Booster
- condiciones de uso, configuración y mantenimiento del dispositivo Bradford-White Corp MAGNUM Series Commercial Electric Booster
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Bradford-White Corp MAGNUM Series Commercial Electric Booster no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Bradford-White Corp MAGNUM Series Commercial Electric Booster y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Bradford-White Corp en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Bradford-White Corp MAGNUM Series Commercial Electric Booster, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Bradford-White Corp MAGNUM Series Commercial Electric Booster, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Bradford-White Corp MAGNUM Series Commercial Electric Booster. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
MAGNUM Series Commercial Electric Booster Inst allation and Operating Manual I&W #07.05.228.00 No opere este equipo al menos que haya leído y comprendido el contenido de este manual! Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede result ar en un serio lesión o muerte. Este manual con tie ne im port ante[...]
-
Página 2
i CONTENTS Form No. EBOOSTERBWM-1009 INTRODUCTION The Bradford White Magnum Series Commercial Electric Booster water heater is designed for use with commercial dishwashers to boost the temperature of the regularly available hot water , usually 1 10°–150°F (43°–66°C) up to 180°F (82°C). W ater at 180°F (82°C) can be used as sanitizing ri[...]
-
Página 3
IMPORT ANT SAFETY INFORMA TION Form No. EBOOSTERBWM-1009 1 ELECTRIC SHOCK HAZARD: • This unit must be inst alled by qualified, trained inst allers. Installation must conform to all local electrical and plumbing codes. Check with your local plumbing and electrical inspectors for proper procedures and codes. • T urn power OFF at disconnect switch[...]
-
Página 4
IMPORT ANT SAFETY INFORMA TION Form No. EBOOSTERBWM-1009 2 Unit s are equipped with a high temperature limit safety switch that will shut off power if the unit overheat s. Cont act an Authorized Service Agent if high temperature limit safety switch cannot be reset or continues to trip. Inst all booster water heater as close as possible to the comme[...]
-
Página 5
MODEL DESCRIPTION SPECIFICA TIONS Form No. EBOOSTERBWM-1009 3 M a g n u m S e r i e s C o m m e r ci a l E l e c t r i c B o o s te r The Magnum Series Commercial Electric Booster water heater includes a booster heater with low-water cut-off system, temperature/pr essure relief valv e, pressure reduci ng valve with buil t-i n hig h pre ssu re by pa[...]
-
Página 6
Model kW V olt s Phase Amp Draw Breaker or Copper Conduit L1 L2 L3 Fuse Size Wire Size Size LI663CFC 6 208 1 29 29 - 40 8 1/2" (13 mm) LI663CFD 6 208 3 14 25 14 40 8 1/2" (13 mm) LI663CFE 6 240 1 25 25 - 40 8 1/2" (13 mm) LI663CFF 6 240 3 13 22 13 30 10 1/2" (13 mm) LI663CFM 6 480 36 1 1 6 15 14 1/2" (13 mm) LI693CFC 9 208 [...]
-
Página 7
SPECIFICA TIONS Form No. EBOOSTERBWM-1009 5 Wire size is based on THHN wire for branch circuit protection at .91 derate factor . Circuit breakers and fused disconnects are to be mounted remote and wired by contractor . Sizes are based on the 2002 NEC table 310-16. Conduit size based on conductors plus ground wire sizing per T able C1 from Appendix [...]
-
Página 8
INST ALLA TION Form No. EBOOSTERBWM-1009 6 General For th e most e ff ecti ve ope rati on, in st all th e boos ter wa ter he ater as close as possible to the commercial dish machine. The location must have a solid foundation or strong table/counter construction along with being clean and dry . Adequate front clearance is required to allow for acces[...]
-
Página 9
INST ALLA TION Form No. EBOOSTERBWM-1009 7 Figure 4. Components Shipped with the Magnum Series Commercial Electric Booster Legs Mounting Bracket s with Hardware T emperature/Pressure Gauge T emperature/Pressure Relief V alve Plastic Leg S tainless S teel Leg A set of mounting brackets or a set of legs are supplied with each booster water heater . T[...]
-
Página 10
INST ALLA TION Form No. EBOOSTERBWM-1009 8 T emperature/Pressure Relief V alves For pr otec tion a gain st ex cess ive pr ess ures a nd tem pera tur es in the booster heater , install temperature/pressure protective equipment required by local codes. The temperature/pressure relief valve supplied with this booster water heater is constructe d with [...]
-
Página 11
INST ALLA TION Form No. EBOOSTERBWM-1009 9 Plumbing Connections Use the following procedures to connect the inlet and outlet water lines as well as inspect the system once the plumbing connections are complete. Do not connect an exp ansion t ank of any type to booster water heater lines. Use only plumbing material suit able for a minimum water temp[...]
-
Página 12
INST ALLA TION Form No. EBOOSTERBWM-1009 10 T emperature/Pressure Gauge T emperature/Pressure Relief V alve 150 psi (1034 kPa)/210°F (99°C) 3/4″ Union* Pressure Reducing V alve w/Bypass. Maximum 20 psi (138 kPa) flow pressure. T emperature/Pressure Gauge Outlet to dish machine Shock Absorber † Drain V alve* 3/4″ Union* Floor Drain Outlet In[...]
-
Página 13
INST ALLA TION Form No. EBOOSTERBWM-1009 11 DO NOT turn on power to the booster water heater until t ank has been filled with water and all air has been vented through dish machine rinse nozzle. The heating elements will burn out in seconds if operated when they are not immersed in water . Electrical — All Sizes and V olt ages General Bradfor d W[...]
-
Página 14
OPERA TION Form No. EBOOSTERBWM-1009 12 General Use the following procedures to operate the Magnum Series Commercial Electric Booster water heater . Read all safety messages in the Important Safety Information section before operating this equipment. DO NOT turn on power to the booster water heater until t ank has been filled with water and all air[...]
-
Página 15
MAINTENANCE Form No. EBOOSTERBWM-1009 13 General Bradford White Magnum Series Commercial Electric Booster water heaters are designed for maximum durability and performance, with minimum maintenance. ELECTRIC SHOCK HAZARD: • T u rn powe r OFF at di sconn ect sw itch/ circu it brea ker and allow unit to cool before performing any maintenance or cle[...]
-
Página 16
MAINTENANCE TROUBLESHOOTING GUIDE Form No. EBOOSTERBWM-1009 14 General ELECTRIC SHOCK HAZARD: • T urn power OFF at disconnect switch/circuit breaker and allow unit to cool before performing any maintenance or cleaning. • This unit must be serviced by qualified personnel only . Service by unqualified personnel may lead to electric shock or burn.[...]
-
Página 17
TROUBLESHOOTING GUIDE Form No. EBOOSTERBWM-1009 15 Symptom Probable Cause Corrective Action W ater reaches 180°F (82°C) but does not last through the entire dishwasher operation. Low incoming water temperature. Incoming water temperature must be adequate for booster size. Increase incoming water temperature. Incoming water temperature drops. Prim[...]
-
Página 18
TROUBLESHOOTING GUIDE Form No. EBOOSTERBWM-1009 16 Symptom Probable Cause Corrective Action W ater at dish machine is not at the proper temperature. Gauge(s) not working properly . Check temperature of water with a thermometer to be certain gauges are working correctly . If not, replace gauge(s). Thermostat set too low . Adjust or recalibrate. If t[...]
-
Página 19
ACCESSORIES Form No. EBOOSTERBWM-1009 17 St ainless Steel Adjust able Legs 1. Carefully place the unit on its side. Do not lay unit on the side with the control p anel. Damage to the unit could occur . 2. Thread the adjustable legs into the existing leg holes on the bottom of the unit. 3. Af ter all legs are secure, return the unit to the upright p[...]
-
Página 20
WIRING DIAGRAMS Form No. EBOOSTERBWM-1009 18 10-01-454 6 – 9 kW Wiring Diagram, All V oltages, Single- or Three-Phase 10-01-448 12 – 18 kW Wiring Diagram, All V oltages, Three-Phase[...]
-
Página 21
WIRING DIAGRAMS Form No. EBOOSTERBWM-1009 19 10-01-452 12 – 15 kW Wiring Diagram, 208 and 240 V , Single-Phase 10-01-447 18 kW Wiring Diagram, 208 and 240 V , Single-Phase[...]
-
Página 22
WIRING DIAGRAMS Form No. EBOOSTERBWM-1009 20 10-01-432 24 – 30 kW Wiring Diagram, 240 V , Single-Phase 10-01-433 24 – 36 kW Wiring Diagram, 208 and 240 V , Three-Phase[...]
-
Página 23
WIRING DIAGRAMS Form No. EBOOSTERBWM-1009 21 10-01-435 24 – 36 kW Wiring Diagram, 480 V , Three-Phase 10-01-436 36 kW Wiring Diagram, 240 V , Single-Phase[...]
-
Página 24
WIRING DIAGRAMS Form No. EBOOSTERBWM-1009 22 10-01-434 45 – 57 kW Wiring Diagram, 480 V , Three-Phase 10-01-437 36 – 57 kW Wiring Diagram, 208 and 240 V , Three-Phase[...]
-
Página 25
LIMITED COMMERCIAL W A TER HEA TER W ARRANTY Form No. EBOOSTERBWM-1009 23 WHA T DOES THIS LIMITED W ARRANTY COVER? This l imit ed war rant y cov ers bo th the t ank and comp onen t pa rt s for leakage or other m alfunction caused by d efects in ma terials and/or workmanship. It extends to the first buyer and to any subsequent owner(s) as long as th[...]
-
Página 26
LIMITED COMMERCIAL W A TER HEA TER W ARRANTY (CONTINUED) Form No. EBOOSTERBWM-1009 24 WHA T SHOULD YOU DO T O KEEP THE W ARRANTY IN EFFECT? T o facilitate warranty assist ance, you should: 1. Follow all instructions enclosed with the product. 2. Retain all bills of sale or receipts for proof of inst allation, etc. 3. Contact your installer , dealer[...]
-
Página 27
NOTES Form No. EBOOSTERBWM-1009 25[...]
-