Bradford-White Corp Powered Direct Vent Series manual
- Consulta online o descarga el manual de instrucciones
- 43 páginas
- 0.32 mb
Ir a la página of
manuales de instrucciones parecidos
-
Water Heater
Bradford-White Corp ACCESSORY MODULE Including Protection, Performance, and Inlet Shut-off Valve Packages
76 páginas 3.28 mb -
Water Heater
Bradford-White Corp PDV100T360
52 páginas 3.21 mb -
Water Heater
Bradford-White Corp U4TW50T*FRN
52 páginas 4.09 mb -
Water Heater
Bradford-White Corp TW450565
36 páginas 2.56 mb -
Water Heater
Bradford-White Corp X)
40 páginas 1.66 mb -
Water Heater
Bradford-White Corp SDW265T
16 páginas 0.98 mb -
Water Heater
Bradford-White Corp 9kW
28 páginas 0.26 mb -
Water Heater
Bradford-White Corp EF100T300(E)*(N
92 páginas 7.65 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Bradford-White Corp Powered Direct Vent Series. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Bradford-White Corp Powered Direct Vent Series o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Bradford-White Corp Powered Direct Vent Series se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Bradford-White Corp Powered Direct Vent Series, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Bradford-White Corp Powered Direct Vent Series debe contener:
- información acerca de las especificaciones técnicas del dispositivo Bradford-White Corp Powered Direct Vent Series
- nombre de fabricante y año de fabricación del dispositivo Bradford-White Corp Powered Direct Vent Series
- condiciones de uso, configuración y mantenimiento del dispositivo Bradford-White Corp Powered Direct Vent Series
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Bradford-White Corp Powered Direct Vent Series no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Bradford-White Corp Powered Direct Vent Series y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Bradford-White Corp en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Bradford-White Corp Powered Direct Vent Series, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Bradford-White Corp Powered Direct Vent Series, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Bradford-White Corp Powered Direct Vent Series. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
238 - 42047 - 00F REV 10/04 POWERED DIRECT VENT SERIES GAS - FIRED WATER HEATER A Spanish language version of these instructions is available by contacting the company listed on the rating plate. La version espanola de estas instrucciones se puede obtener al escribile a la fabrica cuyo nombre aparece en la placa de especificaciones. WHAT TO DO IF Y[...]
-
Página 2
2 CONGRATULATIONS! You have just purchased one of the finest water heaters on the market today! This installation, operation and instruction manual will explain in detail the installation and maintenance of your new Powered Direct Vent Series Gas - Fired Residential Water Heater. We at Bradford White strongl y recommend that you contact a plumbing [...]
-
Página 3
3 TABLE OF CONTENTS page GENERAL INFORMATION ............................................................ 4 INSTALLATION. ............................................................................. 5 Locating The Water Heater .................................................... 5 Minimum Clearances ................................................[...]
-
Página 4
4 GENERAL INFORMATION This gas - fired water heater’s design is certified by CSA International under the American National Standard Z21.10.1 - ( as indicated on the rating plate) and CSA 4.1 - M - (as indicated on the rating plate). This water heater must be installed in accordance with local codes or, in the absence of local codes, the National [...]
-
Página 5
5 General Information continued - A sacrificial anode is used to extend tank life. The removal of this anode, for any reason, will nullify the wa rranty. In areas where water is unusually active, an odor may occur at the hot water faucet due to a reaction between the sacrificial anode and the impurities in the water. If this should happen, an alter[...]
-
Página 6
6 Installation (Locating The Water Heater) continued - Water heater corrosion and component failure can be caused by the heating and breakdown of airborne chemical vapors. Examples of some typical compounds that are potentially corrosive are: spray can propellants, cleaning solvents, refrigerator and air conditioning refrigerants, swimming pool che[...]
-
Página 7
7 Installation (Locating The Water Heater) continued - The water heater must be located close enough to the outside wall to keep the venting distance within the maximum distance described in the installation instructions. Read the venting section in this installation instruction manual bef ore locating the water heater. This water heater must be lo[...]
-
Página 8
8 Installation (Minimum Clearances) continued - M inimum Clearances This installation must allow access to the front of the water heater and adequate clearance must be provided for servicing and operating this water heater. The water heater may be installed on either a combustible or non - combustible floor. If the water heater is to be installed d[...]
-
Página 9
9 Venting continued - (F) The vent sy stem must be inspected at least once a year to ensure against leakage of exhaust products. Exceptions For Installations in Canada: (A) The vent terminals must be located at least 1 foot (.31 m) from any window or door, which can be opened in any building, any non - mechanical air supply inlet to any building, o[...]
-
Página 10
10 Venting continued - Venting Installation Instructions For Supplied Intake Venting: 1. Refer to Figure 1, “Vent Assembly Illustration” to install intake venting as described below. 2. Insert one end of the Vertical Pipe into Metal Boot on the lower ba ckside of the water heater. 3. Slide the Support Bracket over the Vertical Pipe, but do not [...]
-
Página 11
11 Venting continued - Figure 1 Vent Assembly Illustration INTERNET VERSION FOR REFERENCE ONLY[...]
-
Página 12
12 Venting continued - Venting System Condensation Condensate formation does not occur in all installations of power vented heaters, but should be protected against on installations where condensation can form in the venting sys tem. Formation of condensation in the venting system of Power Vented water heaters is dependent upon installation conditi[...]
-
Página 13
13 Venting continued - 3. In order to prevent condensate from draining back into the blower (vertical or horizontal runs), a drain tee and condensate trap can be installed in the horizon tal vent as close as practical to the blower vent connection (see Figure 2). The condensate disposal tube should be installed to drain any accumulated condensate a[...]
-
Página 14
14 Venting continued - This water heater is a power direct vented appliance and is designed to intake and exhaust its products of combustion through 3” (7.6 cm) or 4” (10.2 cm) diameter Schedule 40 PVC pipe to the outdoors. This water heater may intake and exhaust either through the wall or vertically through the roof. Use a 3” (7.6 cm) to 4?[...]
-
Página 15
15 Venting continued - EXAMPLE: The exhaust has two 90° elbows and the intake has four 90° elbows. The total feet of straight pipe on the exhaust is 15 ft. (4. 6 m) and the total feet of straight pipe on the intake is 20 ft (6.1 m). Figure 3 six 90° elbows x 5 ft. each = 30 ft Total straight pipe = 11 ft+3 ft+1 ft+3 ft+9 ft+6 ft+2 ft= 35 ft Tota[...]
-
Página 16
16 Venting continued - TABLE 2 - VENT CONNECTOR LENGTHS FOR 3” (7.6 cm) DIAMETER PVC Total # of 90° elbows (Intake + Exhaust) Maximum # of feet of straight pipe (Intake + Exhaust) 2 70 (21.3 m) 3 65 (19.8 m) 4 60 (18.3 m) 5 55 (16.8 m) 6 50 (15.2 m) 7 45 (13.7 m) 8 40 (12.2 m) TABLE 3 - VENT CONNECTOR LENGTHS FOR 4” (10.1 cm) DIAMETER PVC Tota[...]
-
Página 17
17 Venting continued - NOTE : ABS or CPVC pipes may be substituted for PVC pipe. Do not mix ABS and PVC pipe in the same installation. THROUGH THE WALL VENTING: Cut a 3 1/2 in. (8.9 cm) diameter hole in the wall at the point where the vent connector is going to pass through the wall. Use the proper cement to secure the 90° vent terminal provided w[...]
-
Página 18
18 Venting continued - THROUGH THE WALL VENTING WITH LOW GROUND CLEARANCE: When venting cannot exit through the wall at a height greater than or equal to 12” (30.5 cm) above the ground or anticipated snow level, the installation must be modified as shown below (see Figure 6). Refer to Table 4 for maximum venting lengths using 3” (7.6 cm) PVC or[...]
-
Página 19
19 Venting continued - TABLE 4 3” (7.6 cm) PVC VENT CONNECTOR LENGTHS FROM INSIDE WALL FOR LOW GROUND CLEARANCE INSTALLATIONS Terminating # of Elbows (intake + exhaust) Maximum # of Feet o f Straight Pipe (intake + exhaust) (2) 90 ° Elbows with (1) 90 ° Elbow 2 50 ft (15.2 m) (2) 90 ° Elbows with (1) 90 ° Elbow 3 45 ft (13.7 m) (2) 90 ° Elbo[...]
-
Página 20
20 (2) 90 ° Elbows with (1) 90 ° Elbow 8 90 ft (27.5 m) INTERNET VERSION FOR REFERENCE ONLY[...]
-
Página 21
21 Venting continued - When venting through the wall, the exhaust terminal must exit the structure at a minimum of 16” (40.6 cm) from either side, or any location above the intake terminal. The exhaust terminal must not be located below the intake terminal for any reason (See Figure 7). Figure 7 THROUGH THE ROOF VENTING: (VERTICAL VENTING) Cut th[...]
-
Página 22
22 Figure 8 INTERNET VERSION FOR REFERENCE ONLY[...]
-
Página 23
23 Venting continued - HIGH ALTITUDE INSTALLATIONS FOR ELEVATIONS OVER 2,000 FEET (914.5 m) ABOVE SE A LEVEL T he capacity of the induced draft blower declines with increasing altitude due to a reduction in the air density. In order to assure safe and reliable performance of the water heater, the following guidelines must be followed. Refer to the [...]
-
Página 24
24 Water Connections Note: BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE MAIN WATER SUPPLY VALVE. After shutting off the main water supply, open a faucet to relieve the water line pressure to prevent any water from leak ing out of the pipes while making the water connections to the water heater. After the pressure has been relieved, close the [...]
-
Página 25
25 Water Connections continued - WARNING For protection against excessive temperatures and pressure, install temperature and pressure protective equipment required by local codes, but not less than a combination temperature and pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of produc[...]
-
Página 26
26 Water Connections continued - This water heater can deliver scalding temperature water at any faucet in the system. Be careful whenever using hot water to avoid scalding injury. Cer tain appliances such as dishwashers and automatic clothes washers may require increased temperature water. By setting the thermostat on this water heater to obtain t[...]
-
Página 27
27 Gas Connections The gas supply lines must meet all requirements of the National Fuel Gas Code ANSI Z223.1 - (Late st Edition) and/or in Canada CAN/CGA B149 Installation Codes - (Latest Editions). The minimum permissible gas supply pressure for the purpose of input adjustment is 1.5” water column (.37 kPa) above the operating manifold pressure [...]
-
Página 28
28 Electrical Connections All electrical wiring and connections must be in accorda nce with the National Electric Code ANSI/NFPA No. 70 (latest edition), or the Canadian Electrical Code C22.1 (latest edition) and any local codes, which may apply. The water heater must be electrically grounded. If a flexible line cord and plug is permitt ed by local[...]
-
Página 29
29 Electrical Connections (Figure 9) continued - Figure 9 INTERNET VERSION FOR REFERENCE ONLY[...]
-
Página 30
30 GENERAL OPERATION TO FILL THE WATER HEATER 1. Close the water heater drain valve using a standard screwdriver. 2. Open the cold water supply shut - off valve. 3. Open several hot water faucets to allow air to escape from t he system. 4. When a steady stream of water flows from the faucets, the water heater is filled. Close the faucets and check [...]
-
Página 31
31 General Operation (Lighting and Shutdown Instructions) continued - Lighting and Shutdown Instructions INTERNET VERSION FOR REFERENCE ONLY[...]
-
Página 32
32 Thermostat Adjustment The thermostat dial is adjusted to approximately 120°F when shipped from the factory. When adjusting the thermostat, it should be remembered that lower temperature settings are more energy efficient. The thermostat cover, to the right of the gas valve, must be removed when the thermostat is adjusted. To adjust the thermost[...]
-
Página 33
33 Burner Flame Check Cast Iron Burner: At the time of installation and at periodic intervals (not more than 6 months), a visual check of the main burner and pilot flames should be made to determine if they are burning properly. For ideal operation, the gas and air must be properly proportioned. The proper air - gas mixture is obtained by adjusting[...]
-
Página 34
34 MAINTENANCE A qualified service technician should perform the following maintenance at the minimum periodic intervals suggested below. In some installations, the maintenance interval may be more frequent depending on the amount of use and the operating conditions of the water heater. Regular inspection and maintenance of the water heater and ven[...]
-
Página 35
35 Maintenance continued - 5. Annually remove the inner door and main burner assembly to clean orifices and related parts of an y dirt or other foreign material. Inspect the burner ports for obstructions or debris and clean with a wire brush as needed. Wire brush and/or vacuum clean the combustion chamber as needed to remove scale deposits and debr[...]
-
Página 36
36 Maintenance (continued) - Contact your supplier or plumbing professional for replacement parts or contact the company at the address given on the rating plate of the water heater. Provide the part name, model and serial numbers of the water heater when ordering parts. READ THE WARRANTY FOR A FULL EXPLANATION OF THE LENGTH OF TIME THAT PARTS AND [...]
-
Página 37
37 PARTS LIST DRAWING PART NAME AND DESCRIPTION 1. Blower Assembly 12. Anode – Nipple 2. Rubber Intake Elbow 13. Thermostat (Behind Cover) 3. Intake Tee (Supplied) 14. Thermostat Cover 4. Vert ical Pipe (Supplied) 15. T & P Relief Valve Opening 5. Metal Intake Boot 16. Gas Feedline 6. Flue Baffle 17. Air Shutter (Cast Iron Only) 7. Fiberglass[...]
-
Página 38
38 11. Diptube – Nipple INTERNET VERSION FOR REFERENCE ONLY[...]
-
Página 39
39 BLOWER PARTS DRAWING PART NAME AND DESCRIPTION 1. Exhaust Pressure Switch 2. ECO Switch 3. Intake Collar 4. Exhaust Connection 5. Junction Box 6. Transformer (Behind Junction Box Cover) 7. Six Pin Blower Connector 8. Intake Pressure Switch (Not Shown) INTERNET VERSION FOR REFERENCE ONLY[...]
-
Página 40
40 THE FOLLOWING INSTRUCTIONS ARE FOR INSTALLATION OF: GAS WATER HEATERS SUITABLE FOR WATER (POTABLE) HEATING AND SPACE HEATI NG 1. All piping components connected to this water heater for space - heating applications must be suitable for use with potable water. In Massachusetts, space heating piping length must not exceed 50 feet. 2. Toxic chemica[...]
-
Página 41
41 VENT PIPE PREPARATION AND JOINING Most failures in PVC, CPVC or ABS systems result from improper preparation and joining of pipe and fittings. The guidelines below must be followed when installin g the venting system. If you have any question about the application or installation of the PVC, CPVC or ABS venting system, contact the manufacturer, [...]
-
Página 42
42 Vent Pipe Preparation and joining (continued) - d) Cementing must be done quickly to avoid over - drying before joining. i) Apply one coat to the outside end of the pipe at a width slightl y greater than the depth of the socket. ii) Apply a coat around the inside of the fitting socket. iii) Apply a second coat around the end of the pipe. 4) Join[...]
-