Briggs & Stratton 30235 manual
- Consulta online o descarga el manual de instrucciones
- 48 páginas
- 4.28 mb
Ir a la página of
manuales de instrucciones parecidos
-
Portable Generator
Briggs & Stratton 040204, 040210, 040212, 040213, 040229, 040234
56 páginas 3.72 mb -
Portable Generator
Briggs & Stratton 030235-01
48 páginas 4.51 mb -
Portable Generator
Briggs & Stratton 30235
48 páginas 4.28 mb -
Portable Generator
Briggs & Stratton 030208-1
6 páginas 0.69 mb -
Portable Generator
Briggs & Stratton 030320
44 páginas 2.85 mb -
Portable Generator
Briggs & Stratton 01970
37 páginas 1.41 mb -
Portable Generator
Briggs & Stratton Generator
84 páginas 4.72 mb -
Portable Generator
Briggs & Stratton Home Generator System
68 páginas 3.32 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Briggs & Stratton 30235. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Briggs & Stratton 30235 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Briggs & Stratton 30235 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Briggs & Stratton 30235, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Briggs & Stratton 30235 debe contener:
- información acerca de las especificaciones técnicas del dispositivo Briggs & Stratton 30235
- nombre de fabricante y año de fabricación del dispositivo Briggs & Stratton 30235
- condiciones de uso, configuración y mantenimiento del dispositivo Briggs & Stratton 30235
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Briggs & Stratton 30235 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Briggs & Stratton 30235 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Briggs & Stratton en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Briggs & Stratton 30235, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Briggs & Stratton 30235, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Briggs & Stratton 30235. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
SA VE THESE INS TR UCTIONS Model / Modelo 030235 5550 W A TTS 8550 S T AR TING W A TTS Oper ator ’ s Manual Manual del Oper ario Manual No. 200907GS Revision - (08/10/2006) Failure to read and follow the Operator’s Manual and all operating instructions can result in death, bodily injury, and/or property damage. W ARNING Si no se leen y siguen l[...]
-
Página 2
Briggs & Stratton Power Products Group, LLC 900 North Parkway Jefferson, WI 53549 Copyright © 2006 Briggs & Stratton Power Products Group, LLC. All rights reserved. No part of this material may be reproduced or transmitted in any form by any means without the express written permission of Briggs & Stratton Power Products Group, LLC. Ge[...]
-
Página 3
1 T ab le of Contents Safety R ules ..............................................................2 Equipment Description ..........................................................4 Assemb ly ...................................................................4 Unpack Generator .................................................................4 Shipm[...]
-
Página 4
2 BRIGGSandSTRATTON.com SA VE THESE INS TR UCTIONS Safety R ules This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. The safety alert symbol ( ) is used with a signal word ( DANGER , WARNING, CAUTION ), a pictorial and/or a[...]
-
Página 5
3 When adjusting or making repairs to your generator: • Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug. When testing for engine spark: • Use approved spark plug tester. • DO NOT check for spark with spark plug removed. Unintentional sparking can result in fire or electric shock. W ARNI[...]
-
Página 6
4 BRIGGSandSTRATTON.com A ssembly Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended fuel and oil level is verified. If you have any problems with the assembly of your generator, please call the generator helpline at 1-800-743-4115. If calling for assistance, please have the model, re[...]
-
Página 7
5 5. Install e-ring with pliers, squeezing from top of e-ring to bottom of axle. 6. Repeat steps 4 and 5 to secure second wheel. 7. Tip generator so that engine side is down. 8. Line up holes in support leg ( E ) with holes in generator frame. 9. Attach support leg using 2 capscrews (M8 x 16 mm) ( F ) and 2 hex nuts ( G ). Tighten with a 13 mm sock[...]
-
Página 8
6 BRIGGSandSTRATTON.com S ystem Gr ound The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles. The system ground is connected to the AC neutral wire (the neutral is bonded to the generator frame). Special Requirements There may be Federal or State Occupational Safety and [...]
-
Página 9
7 A - 120 Volt AC, 20 Amp, Duplex Receptacles — May be used to supply electrical power for the operation of 120 Volt AC, 20 Amp, single phase, 60 Hz electrical, lighting, appliance, tool, and motor loads. B - 120/240 Volt AC, 30 Amp Locking Receptacle — May be used to supply electrical power for the operation of 120 and/or 240 Volt AC, 30 Amp, [...]
-
Página 10
8 BRIGGSandSTRATTON.com Receptac les 120/240 Volt AC, 30 Amp, Locking Receptacle Use a NEMA L14-30 plug with this receptacle. Connect a 4-wire cord set (A) rated for 250 Volt AC loads at 30 Amps (or greater) (Figure 4). You can use the same 4-wire cord if you plan to run a 120 Volt load. This receptacle powers 120/240 Volt AC, 60 Hz, single phase l[...]
-
Página 11
9 Oper ation Starting the Engine Disconnect all electrical loads from the generator. Use the following start instructions: 1. Make sure unit is on a level surface. IMPORTANT: Failure to start and operate the unit on a level surface will cause the unit not to start or shut down during operation. 2. Turn red fuel valve from “ Off ” position (A) t[...]
-
Página 12
10 BRIGGSandSTRATTON.com Connecting Electrical Loads 1. Let engine stabilize and warm up for a few minutes after starting. 2. Plug in and turn on the desired 120 and / or 240 Volt AC, single phase, 60 Hz electrical loads. NOTE: • DO NOT connect 240 Volt loads to the 120 Volt duplex receptacles. • DO NOT connect 3-phase loads to the generator. ?[...]
-
Página 13
11 Don’t O verload Gener ator Capacity You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps: 1. Select the items you will power at the same time. 2. Total the rated (running) watts of these items. This is the amount of power your gen[...]
-
Página 14
12 BRIGGSandSTRATTON.com General Recommendations Regular maintenance will improve the performance and extend the life of the generator. See any authorized Briggs & Stratton dealer for service. The generator’s warranty does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the op[...]
-
Página 15
13 Generat or Maintenance Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture, or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves, or any other foreign material. NOTE: [...]
-
Página 16
14 BRIGGSandSTRATTON.com SAE 30 : 40 °F and higher (5 °C and higher) is good for all purpose use above 40°F, use below 40°F will cause hard starting. 10W-30 : 0 to 100 °F (-18 to 38 °C) is better for varying temperature conditions. This viscosity improves cold weather starting, but may increase oil consumption above 80ºF (27ºC). Synthetic 5[...]
-
Página 17
15 Service Air Cleaner Your engine will not run properly and may be damaged if you run it with a dirty air cleaner. Replace the air cleaner every 25 hours of operation or once each year, whichever comes first. Replace more often if operating under dirty or dusty conditions. To service the air cleaner, follow these steps: 1. Loosen screws ( A ) and [...]
-
Página 18
16 BRIGGSandSTRATTON.com Clean and inspect the spark arrester as follows: 1. To remove muffler heat shield ( A ) from muffler ( B ), remove four screws that connect guard to muffler bracket (Figure 14). 2. Remove four screws that attach spark arrester screen ( C ). 3. Inspect screen and obtain a replacement if torn, perforated or otherwise damaged.[...]
-
Página 19
17 Stor age The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage. Generator Storage • Clean the generator as outlined in Cleaning in the Maintenance section. • Check t[...]
-
Página 20
18 BRIGGSandSTRATTON.com T r oubleshooting Pr oblem Cause Corr ection Engine is running, but no AC output is available. 1. One of the circuit breakers is open. 2. Fault in generator. 3. Poor connection or defective cord set. 4. Connected device is bad. 1. Reset circuit breaker. 2. Contact authorized service facility. 3. Check and repair. 4. Connect[...]
-
Página 21
19 Specif ications Engine T echnical Infor mation This is a single cylinder, overhead valve(OHV), air cooled engine. It is a low emissions engine. In the State of California, Model Series 200000 engines are certified by the California Air Resources Board to meet emissions standards for 250 hours. Such certification does not grant the purchaser, own[...]
-
Página 22
20 BRIGGSandSTRATTON.com Briggs & Stratton Corporation (B&S), the California Air Resources Board (CARB) and the United States Environmental Protection Agency (U.S. EPA) Emissions Control System Warranty Statement (Owner’s Defect Warranty Rights and Obligations) Califor nia, United Stat es and Canada Emissions Control Def ects W arr anty S[...]
-
Página 23
21 3. No Charge Repair or replacement of any Warranted Part will be performed at no charge to the owner, including diagnostic labor which leads to the determination that a Warranted Part is defective, if the diagnostic work is performed at an Authorized B&S Service Dealer. For emissions warranty service contact your nearest Authorized B&S S[...]
-
Página 24
22 BRIGGSandSTRATTON.com BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC PORTABLE GENERATOR OWNER WARRANTY POLICY LIMITED WARRANTY Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the portable generator that is defective in material or workmanship or both. Transportation charges on product submi[...]
-
Página 25
This page reserved.[...]
-
Página 26
Briggs & Stratton Power Products Group, LLC. 900 North Parkway Jefferson, WI 53549 Copyright © 2006 Briggs & Stratton Power Products Group, LLC. Reservados todos los derechos. Queda prohibida la reproducción o transmisión total o parcial de este material, sea cual sea la forma y el medio empleados para ello, sin el permiso previo y por e[...]
-
Página 27
1 T ab la de Conteni do Reglas de segur idad .................................................2 Descripción del equipo ..........................................................4 Montaje ......................................................................4 Desembalaje del generador ..................................................4 Contenido de[...]
-
Página 28
2 BRIGGSandSTRATTON.com CONSER VE ES T A S INS TR UCCIONES Normas de segur idad Éste es el símbolo de alerta de seguridad. Sirve para advertir al usuario de un posible riesgo para su integridad física. Siga todos los mensajes de seguridad que figuren después de este símbolo para evitar lesiones o incluso la muerte. El símbolo de alerta de seg[...]
-
Página 29
3 • Cuando arranque el motor, tire lentamente del cable hasta sentir una resistencia y, a continuación, tire rápidamente de él para evitar su retroceso. • NUNCA arranque o pare el motor cuando haya aparatos eléctricos conectados y en funcionamiento. El rápido repliegue del cable del arrancador (retroceso) impedirá que el usuario suelte el[...]
-
Página 30
4 BRIGGSandSTRATTON.com Descripción del equipo Lea atentamente este manual y familiarícese con el generador. Conozca sus aplicaciones, limitaciones y riesgos. Este generador funciona en base a un motor de campo eléctrico giratorio y de corriente alterna (CA). Fue diseñado con la finalidad de proveer energía eléctrica para lámparas eléctrica[...]
-
Página 31
5 5. Para ello, apriete con unos alicates desde la parte superior de la anilla en “e” hacia la parte inferior del eje. 6. Repita los pasos 4 y 5 para asegurar la segunda rueda. 7. Dele la vuelta al generador de forma que el lado del motor quede abajo. 8. Haga coincidir los orificios de la pata de apoyo (E) con los del bastidor del generador. 9.[...]
-
Página 32
6 BRIGGSandSTRATTON.com Tierr a del sistema El generador dispone de una conexión a tierra del sistema que conecta los componentes del bastidor a los terminales de tierra de los enchufes hembra de salida de CA. La tierra del sistema está conectada al cable de CA neutro que, a su vez, está conectado al bastidor del generador. Requisitos Especiales[...]
-
Página 33
7 Contr oles y caract erísticas del gener ador Lea este Manual del Operario y reglas de seguridad antes de poner en marcha su generador. Compare las ilustraciones con su generador, para familiarizarse con la ubicación de los diversos controles y ajustes. Guarde este manual para futuras consultas. A - Tomacorriente Dobles de 120 Voltios AC, 20 Amp[...]
-
Página 34
8 BRIGGSandSTRATTON.com T omas eléctricas Dispositiv o de segur idad de 1 20/240 V , 30 A Use un tapón NEMA L14-30 con este receptáculo. Conecte un juego de cable de 4 alambres (A) , clasificado como 250 Voltios AC a 30 Amps (o mayor) (Figura 4). Usted puede usar el mismo cable de 4-alambres si planea trabajar con una carga de 120 Voltios. Este [...]
-
Página 35
9 Oper ando Encienda el motor Desconecte todas las cargas eléctricas del generador. Use las siguientes instrucciones para encender: 1. Asegúrese de que la unidad está en una superficie plana. IMPORTANTE: Si la unidad no se arranca y utiliza en una superficie plana, se pueden producir problemas de arranque y de parada durante el funcionamiento. 2[...]
-
Página 36
10 BRIGGSandSTRATTON.com Conexión de car gas eléctricas 1. Deje que el motor se estabilice y se caliente por dos minutos después del arranque. 2. Enchúfelo y encienda la carga eléctrica deseada (120 y/o 240 V CA, monofásico, 60 Hz.) IMPORTANTE: • NO conectar cargas de 240 V en las tomas eléctricas dobles. • NO conectar cargas trifásicas[...]
-
Página 37
11 No sobrecar gar el generador Capacidad Debe asegurarse de que su generador puede proveer los suficientes vatios de potencia continua (vatiaje nominal) y vatios de salida para los elementos que desee alimentar al mismo tiempo. Siga estos sencillos pasos: 1. Seleccione los elementos que quiere alimentar al mismo tiempo. 2. Sume la potencia nominal[...]
-
Página 38
12 BRIGGSandSTRATTON.com Mantenimient o Plan de mantenimient o Siga los intervalos de horas o de calendario, los que sucedan antes. Si opera en condiciones adversas (señaladas más abajo) es necesario un mantenimiento más frecuente. Plan de Mantenimiento - Anote las Fechas a Medida que Lleve a Cabo las Operaciones de Mantenimiento FECHAS DE MANTE[...]
-
Página 39
13 Mantenimient o del Generador El mantenimiento del generador consiste en conservar la unidad limpia y seca. Opere y almacene la unidad en un ambiente limpio y seco donde no será expuesta al polvo, suciedad, humedad o vapores corrosivos. Las ranuras del aire de enfriamiento del generador no deben estar tapadas con nieve, hojas, o cualquier otro m[...]
-
Página 40
14 BRIGGSandSTRATTON.com SAE 30 : 5 º C (40 º F) y superior es adecuado para todo tipo de usos por encima de 5 ºC (40 ºF). El uso por debajo de 5 ºC (40 ºF) provocará dificultades de arranque. 10W-30 : -18 a 38 º C (0 a 100 º F) es mejor en caso de temperatura variable. La viscosidad mejora el arranque en climas fríos, pero puede aumentar[...]
-
Página 41
15 Servicio del depurador de air e Si se utiliza con un filtro de aire sucio, el motor no funcionará correctamente y puede sufrir daños. Cambie el filtro de aire cada 25 horas de funcionamiento o una vez al año, lo que suceda antes. Haga cambios más frecuentes si trabaja en zonas sucias o donde hay polvo. Para dar servicio al filtro de aire, si[...]
-
Página 42
16 BRIGGSandSTRATTON.com Limpie e inspeccione el apagachispas de la siguiente manera: 1. Para retirar la protección del silenciador (A) de silenciador (B) , retire los cuatro tornillos que conectan la protección a la ménsula del silenciador (Figura 14). 2. Retire los cuatro tornillos que sostienen la pantalla apagachispas (C) . 3. Inspeccione la[...]
-
Página 43
17 Almacenamiento El generador deberá ser encendido al menos una vez cada siete días y deberá dejarlo funcionar al menos durante 30 minutos. Si no puede hacer esto y debe almacenar la unidad por más de 30 días, siga las siguientes instrucciones para preparar su unidad para almacenamiento. Generador 1. Limpie el generador como está descrito en[...]
-
Página 44
18 BRIGGSandSTRATTON.com R esolución de prob lemas Problemo Causa Accion El motor está funcionando pero no existe salida de AC disponsible. 1. El interruptor automático de circuito está abierto. 2. Conexión mal o defectuosa del juego de cables. 3. El dispositivo conectado está dañado. 4. Avería en el generador. 1. Reposicione el interruptor[...]
-
Página 45
19 ESPECIFIC A CIONES Información Técnica Sobre el Motor El motor es de uno cilindros, de válvulas en cabeza (OHV), refrigerado por aire y de baja emisión. En el Estado de California, los motores de la serie 200000 han obtenido la certificación del California Air Resources Board (Consejo de recursos de aire de California) de cumplimiento de la[...]
-
Página 46
20 BRIGGSandSTRATTON.com Briggs & Stratton Corporation (B&S), el California Air Resources Board (CARB, Consejo de recursos de aire de California) y la United States Environmental Protection Agency (U.S. EPA, Agencia estadounidense de protección del medioambiente) Garantía del sistema de control de emisiones (Garantía contra defectos, der[...]
-
Página 47
21 3. Servicio gratuito La reparación o sustitución de toda pieza garantizada se realizará sin cargo alguno para el propietario, incluido el trabajo de diagnóstico que permita determinar que la pieza garantizada es defectuosa, siempre que se realice en un distribuidor autorizado de servicio B&S. En el caso del servicio de garantía de emisi[...]
-
Página 48
22 BRIGGSandSTRATTON.com 198189S, Rev. A, 7/14/2006 Esperamos que disfrute de nuestra garantía y le pedimos disculpas por las molestias causadas. Cualquier distribuidor de servicio autorizado puede llevar a cabo reparaciones en garantía. La mayoría de las reparaciones en garantía se gestionan normalmente, pero algunas veces, la solicitud de ser[...]