Delta OIL-FREE AIR COMPRESSOR CP503 manual
- Consulta online o descarga el manual de instrucciones
- 20 páginas
- 2.04 mb
Ir a la página of
manuales de instrucciones parecidos
-
Air Compressor
Delta CP201
56 páginas 1.16 mb -
Air Compressor
Delta OIL-FREE AIR COMPRESSOR CP503
20 páginas 2.04 mb -
Air Compressor
Delta 66-202-1
72 páginas 2.17 mb -
Air Compressor
Delta A08590
60 páginas 1.82 mb -
Air Compressor
Delta OILLUBE AIR COMPRESSOR D25235 029-2
31 páginas 1.8 mb -
Air Compressor
Delta D27449
72 páginas 1.45 mb -
Air Compressor
Delta DLKC6580V2
30 páginas 1.71 mb -
Air Compressor
Delta D25886
72 páginas 3.26 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Delta OIL-FREE AIR COMPRESSOR CP503. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Delta OIL-FREE AIR COMPRESSOR CP503 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Delta OIL-FREE AIR COMPRESSOR CP503 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Delta OIL-FREE AIR COMPRESSOR CP503, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Delta OIL-FREE AIR COMPRESSOR CP503 debe contener:
- información acerca de las especificaciones técnicas del dispositivo Delta OIL-FREE AIR COMPRESSOR CP503
- nombre de fabricante y año de fabricación del dispositivo Delta OIL-FREE AIR COMPRESSOR CP503
- condiciones de uso, configuración y mantenimiento del dispositivo Delta OIL-FREE AIR COMPRESSOR CP503
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Delta OIL-FREE AIR COMPRESSOR CP503 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Delta OIL-FREE AIR COMPRESSOR CP503 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Delta en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Delta OIL-FREE AIR COMPRESSOR CP503, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Delta OIL-FREE AIR COMPRESSOR CP503, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Delta OIL-FREE AIR COMPRESSOR CP503. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
INSTRUCTION MANUAL P ART NO. A08200 Rev . 0 Copyright © 2004 Delta Machinery T o learn more about DEL T A MACHINER Y visit our website at: www .deltamachinery .com. For Parts, Service, W arranty or other Assistance, please call 1-866-422-4286. Oil-Fr ee Air Compr essor (Model CP503) ESP AÑOL: PÁGINA 21 FRANÇAIS: P AGE 41[...]
-
Página 2
2- ENG A08200 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, may result in minor [...]
-
Página 3
3- ENG A08200 IMPOR T ANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all war nings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire How T o Prevent It What Could Happen It is nor[...]
-
Página 4
4- ENG A08200 WARNING: Risk of Bursting Air T ank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury . How T o Prevent It What Could Happen WARNING: Risk from Flying Objects The compressed air stream can cause soft tissue damage to exposed skin an[...]
-
Página 5
5- ENG A08200 WARNING: Risk to Breathing WARNING: Risk of Electrical Shock HAZARD HAZARD Y our air compressor is powered by electricity . Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution. Electrical Gr[...]
-
Página 6
6- ENG A08200 WARNING: Risk of Bur ns T ouching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation. Do not reach around protective shrouds or attempt maintenance[...]
-
Página 7
7- ENG A08200 Revie w and unders tand all instructio ns and warnings in this manu al. Becom e famil iar with the oper ation and contr ols of the air comp ress or . Keep operat ing area clear of all persons, pets, and obstacl es. Keep childr en away fr om the air compr essor at all times . Do not operate the produ ct when fatig ued or under the infl[...]
-
Página 8
8- ENG A08200 Model No. CP503 Running Horsepower 1.5 Bore 1-7/8" Stroke 1-1/4" V olta ge/Hert z/ Phase 120/60/1 Minimum Branch Circuit Requirement 15 amps *Fuse T ype Time Delay Air T ank Capacity 12 gallons Approximate Cut-in Pressur e 100 Approximate Cut-out Pressur e 135 SCFM @ 40 PSIG 4.9 SCFM @ 90 PSIG 3.5 GLOSSAR Y DUTY CYCLE Access[...]
-
Página 9
INST ALLA TION Location of the Air Compressor Locate the air compr essor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfer e with the flow of air . The air compressor pump and shroud are designed to allow for proper cooling. The ventilation op[...]
-
Página 10
10- ENG A08200 GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by pr oviding an escape wire for the electric current. This air compressor must be properly grounded. The portable air compr essor is equipped with a cord having a grounding wire with an appr opriate grounding plug (s[...]
-
Página 11
11- ENG A08200 V oltage and Circuit Protection Refer to the Parts Manual for the voltage and minimum branch circuit requir ements. Certain air compressors can be operated on a 15 amp circuit if the following conditions are met. 1. V oltage supply through branch circuit is 15 amps. 2. Circuit is not used to supply any other electrical needs (lights,[...]
-
Página 12
12- ENG A08200 OPERA TION Know Y our Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERA TING YOUR UNIT . Compare the illustrations with your unit to familiarize yourself with the location of various contr ols and adjustments. Save this manual for future refer ence. Description of Operation Become familiar with these contr ols b[...]
-
Página 13
13- ENG A08200 Before Starting Br eak-in Procedur e Serious damage (for units with a tank) may result if the following break-in instructions are not closely followed. This procedur e is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced. 1. Make sure the On/Auto/Off lever [...]
-
Página 14
14- ENG A08200 MAINTENANCE Customer Responsibilities Daily or after each use Before each use Check Safety V alve ● D r ai n T a nk ● T o Check Safety V alve If the safety valve does not work properly , over - pressurization may occur , causing air tank rupture or an explosion. Before starting compressor , pull the ring on the safety valve to ma[...]
-
Página 15
15- ENG A08200 T o Replace or Clean Check V alve 1. Release all air pr essure from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. 3. Loosen the nut on the outlet tube and move the outlet tube to the side. 4. Unscrew the check valve (tur n counterclockwise) using a socket wrench. 5. Make sure the valve disc m[...]
-
Página 16
16- ENG A08200 T o Replace Regulator 1. Release all air pr essure from air tank. See "T o Drain T ank" in the Maintenance section. 2. Unplug outfit. 3. Using an adjustable wr ench remove the gauges and hose from the regulator . 4. Remove the regulator . 5. Apply pipe sealant tape to the nipple on the standpipe. 6. Assemble the regulator a[...]
-
Página 17
17- ENG A08200 Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur . Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressur e. PROBLEM CAUSE CORRECTION Pressur e switch does not shut off motor when compress[...]
-
Página 18
18- ENG A08200 Regulator will not shut off air outlet. Damaged regulator . Replace. PROBLEM CAUSE CORRECTION It is normal for "some" pressur e dr op to occur . If there is an excessive amount of pressur e drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph [...]
-
Página 19
19- ENG A08200 PROBLEM CAUSE CORRECTION Motor will not run. Check fuse box for blown fuse and replace as necessary . Reset circuit breaker . Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch cir cuit. Check for proper fuse. Y ou should use a time delay fuse. Check for low voltage problem. Check t[...]
-
Página 20
20- ENG A08200 A08200 LIMITED W ARRANTY DEL T A MACHINERY warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressur e washers, and generators, which have the following warranty per[...]