DKS Enterprises 9100 manual
- Consulta online o descarga el manual de instrucciones
- 53 páginas
- 0.84 mb
Ir a la página of
manuales de instrucciones parecidos
-
Telephone
DKS Enterprises 1817
67 páginas 1.06 mb -
Door
DKS Enterprises 9220
57 páginas 0.65 mb -
Telephone
DKS Enterprises 1815
67 páginas 1.06 mb -
Intercom System
DKS Enterprises 1812 PLUS
53 páginas 0.41 mb -
Telephone
DKS Enterprises 1802
55 páginas 0.28 mb -
Garage Door Opener
DKS Enterprises 9310
55 páginas 0.61 mb -
Telephone
DKS Enterprises 1808
55 páginas 0.28 mb -
Safety Gate
DKS Enterprises 6100
42 páginas 5.92 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones DKS Enterprises 9100. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica DKS Enterprises 9100 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual DKS Enterprises 9100 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales DKS Enterprises 9100, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones DKS Enterprises 9100 debe contener:
- información acerca de las especificaciones técnicas del dispositivo DKS Enterprises 9100
- nombre de fabricante y año de fabricación del dispositivo DKS Enterprises 9100
- condiciones de uso, configuración y mantenimiento del dispositivo DKS Enterprises 9100
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de DKS Enterprises 9100 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de DKS Enterprises 9100 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico DKS Enterprises en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de DKS Enterprises 9100, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo DKS Enterprises 9100, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual DKS Enterprises 9100. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
Model 9100 Vehicular Slide Gate Operator Owner’s Manual DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 9100-065 REV B, 1/01 Copyright 2000 DoorKing, Inc. All rights reserved.[...]
-
Página 2
ii[...]
-
Página 3
iii Use this manual with the following model only . Model 9100-080 with circuit board 4 602-010. DoorKing, Inc. reserves t he right to make chang es in the products described in thi s manual without notice and without obligation of DoorKing, In c. to notify any persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no rep rese[...]
-
Página 4
IMPORTANT NOTICES Vehicular gate sy stems provide convenien ce to thei r users and limit vehicular traffic o nto your property. These systems can p roduce high levels of f o rce; therefore it is important that you are a ware of possible hazards associated with your gate o perating system. These hazards may include pin ch points, entrapment, absence[...]
-
Página 5
IMPORTANT SAFETY INSTRUCTIONS WARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or pl ay with gate controls. Keep the remote control away from children. 3. Always keep people an d objects away from g ate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Test the operator monthly. [...]
-
Página 6
RESTRICTIONS AND WARNINGS Install The Gate Operator Only If: • The operator is appropriate for the usage Cla ss of the appli cation and the gate is within the weight and length limitations specified for the operat or. • All openings of a horizonta l slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.2 m) ab[...]
-
Página 7
ENTRAPMENT PROTECTION This vehicular gate operator is equipped with a n in herent (Type A) entrapment sensing system. This system will sense an obstructi on in both the opening and closing gate cycle s, and will cause the gate to reverse direction should an obst ruction be encoun tered. If the system detects a secon d obstruction before reaching th[...]
-
Página 8
GLOSSARY GATE – A moving barrier su ch as a swinging, slidin g, raising, lowering, or th e like, barrier, that is a stand-alone passag e barrier or is that p ortion of a wa ll or fe nce system that cont rols entrance and/or egress by persons or vehicl es and completes the peri meter of a defined area. RESIDENTIAL VEHICULAR GATE OPERATOR-CLASS I -[...]
-
Página 9
TABLE OF CONTENTS Section 1 – Installation 1.1 Specifications ............................................................................................................. ..............................1 1.2 Mounting Positions 1.2.1 Front Position Pad Mount ..........................................................................................[...]
-
Página 10
Section 4 – Operating Instructions 4.1 Power and Reset Switches .......................................................................................................................31 4.2 Shutdown Conditions 4.2.1 Soft Shutdown ............................................................................................................ .........[...]
-
Página 11
SECTION 1 - INST ALLA TION Prior to beginning the installation of the slide gate operator, we suggest that you become familiar wit h the instructions, illustration s, and wiring guide-lines in this manu al. This will help insure that your installation is performed in an efficient and professio nal manner. The proper installation of the vehicular sl[...]
-
Página 12
1.2 MOUNTING POSITIONS The Model 9100 ope rator is designed so that it can be installed in a ny of the mounting positions shown below. On ce the mounting position ha s been determined, the chain i dlers must be adjusted t o accommodate the mounting po sition c hosen before the operator is mounted to the pad or p ost. The idlers are factory set for [...]
-
Página 13
1.2.3 REAR POSITION PAD OR POST MOUNT • Set one chain idler at t he top position and one chain idler at the center position on the same side of the operator. • Remove the top and bottom chain knockouts from the side of the operator. • Chain enters and exits the operator from the same side. Chain is attached to one end of the gate. • This mo[...]
-
Página 14
1.3 MOUNTING OP TIONS Pad mounting can be use d when the operator will b e installed using either the front or rear mounting position. If the operator is to be center mounted, the post mountin g method must be used. 1.3.1 PAD MOUNTED OPERATORS Gate Minimum 1" clearance between gate and back of operator. 24 18 Conduits can be located in shaded [...]
-
Página 15
1.3.2 POST MOUNTED OPERATORS Post mounting can be used when th e operator will be installed in any of the three mo unting positions, and must be used if the operator is to be center mount ed. 1. Post mounting the operator req uires the use of an operator base plate (P/N 2600-418) and t wo (2) 4 X 4 steel post (not supplied) weld ed to the base plat[...]
-
Página 16
1.4 OPERATOR INSTALLATION Prior to mounting the gate operator, be sure that th e chain kno ckouts and chain idlers are set for the mounting position (front, center or rear) and the mounting option chos en (p ad or post). Refer back to SECTION 1.2. 1.4.1 PAD MOUNTED OPERATORS • Position the operator on t he pad so that there is a minimum clearance[...]
-
Página 17
1.5 CHAIN INSTALLATION 1.5.1 FRONT – PAD MOUNT 1. Secure the chain brackets to each end of the gate so that the brackets are level with the top chain knockouts in the operato r housing. Brackets sho uld be attached to the inside of the frame so th at the chain bolts, when attached, do not protrude beyo nd the frame of the gate (figure 10). 2. Rou[...]
-
Página 18
1.5.2 FRONT – POST MOUNT 1. Secure the chain brackets to each end of the gate so that the brackets are level with the bottom chai n idlers in the operator housing. Brackets should b e attached to the inside of the frame so that the chai n bolts, when attached, do not protrude beyond the frame of the gate. 2. Route the chain through the gate opera[...]
-
Página 19
1.5.3 REAR – PAD OR POST MOUNT 1. Install an endless idler assembly (p/n 2600-818) at the gate op ening between the gate and fence (figure 16, 18 ). Note that the chain is routed between th e fence and the gate in this type of installation. IMPORTANT!! Be sure that the idler assembly is se curely attached to the gatepost, pilaster, etc . 2. Secur[...]
-
Página 20
1.5.4 CENTER – POST MOUNT 1. Install an endless idler assembly (p/n 2600-818) at each end of the gate opening (figure 21). Note that the gate travels between the fence and the chain in this type of installation. IMPORTANT!! Be sure that the idler post/moun t assembly is secure. 2. Secure the chain br ackets to the gate as shown in figure 19. Th e[...]
-
Página 21
1.6 WARNING SIGN INSTALLATION This DoorKing slide gate operator is shipped with two warning signs. The purpose of the wa rning signs is to alert unifo rmed persons, an d to remind persons familiar with the system, that a potential hazard may exist so that appropriate action can be ta ken to avoid the hazard or to redu ce exposure to the hazard. WAR[...]
-
Página 22
12[...]
-
Página 23
SECTION 2 – WIRING Before attempting to connect any wiring to the oper ator, be sure that the circuit breaker in the electrical panel is i n the OFF position. Permanent wi ring must be installed to th e operator as required by local electrical co des. It is recommended that such wo rk be performed by a licen sed electrical contractor. Since build[...]
-
Página 24
2.1 HIGH VOLTAGE CONNECTIONS Use Table 1 to determine high voltage wire size re quirements. T he distance shown in the chart i s measured in feet from the operator to the power so urce. If power wiring is grea ter than the maximum distance shown, it is re commended that a se rvice feeder be installed. When l arge gauge wire is used, a separate junc[...]
-
Página 25
2.2 CONTROL WIRING Controls must be far en ough from the gate so that th e user is prevented from co ming in contact with the gate w hile operating the controls. Outdo or or easily accessible controls should have a security feature to prev ent unauthori zed use. • Connect optional control devices to the operator terminal stri p as shown in figure[...]
-
Página 26
2.3 SECONDARY ENTRAPMENT PR OTECT ION DEVICE WIRING Secondary entrapment protection devi ces must be in stalled to insure a safe o perating environment and to reduce the risk of entrapment. This operato r has inputs f or non-contact sensors a nd contact sensors for both opening and closing g ate cycles. Secondary e ntrapment protection may be provi[...]
-
Página 27
2.3.2 CONTACT SENSORS • Disconnect power to the gate operator before installing the contact sensors. • Connect the contact se nsors as shown below to the auxiliary terminal strip located on the 4602 control board. • Contact sensors must be locate d at the l eading edge, trailing edge, and post mounted both inside and outside of the v ehicular[...]
-
Página 28
2.4 LOOP DETE CTOR WIRING Loops and loop detectors must be installed with th is gate operator to prevent the gate from accidentally closing on vehicles t hat may be in the path of the gate. • Loop detector wiring is shown for DoorKing model 9406 Plug-In loop dete ctor only. If other loop detectors are used, refer to the in stallation instructions[...]
-
Página 29
2.5 GATE TRACKER™ CONNECTIONS This gate operator is equi pped with outputs from the circuit board that will repo rt operator status to a companion DoorKin g Access Control Sy stem (M odel 1803P C, 1815, 1817 or 1818) whe n equipped with an optional Tracker expansi on board. This r eport incl udes items such as gate operator cycl e count, any shor[...]
-
Página 30
2.6 AUXILIARY DEVICES 2.6.1 ALARM RESET SWITCH The gate operator is equi pped with a reset switch th at will silence the entrapment ala rm and return the operator to normal operation after a hard s hutdown occurs. An aux iliary reset button may be added provided that the following conditi on is met. • The alarm-reset button must be locat ed in th[...]
-
Página 31
2.7 MASTER / SLAVE WIRING 2.7.1 OPERATOR INTERFACE The interface wiring between the two operato rs requir es four (4) 18 AWG wires for control plus two (2) additional 18 AWG wires for secondary entrapment protection device connection. Each operator must be connected to it' s own power source as de scribed in section 2.2. Th e loop functions ar[...]
-
Página 32
2.7.2 SECONDARY ENTRAPMENT PROTECTION DEVICE WIRING Secondary entrapment p rotection for slide gate o per ators connected in a m aster / slave configuratio n will require three sets of photo-beams to insure protection. • One photo-beam is directed across th e roadway and connected to the CLOSE photo-b eam input on the auxiliary terminal strip of [...]
-
Página 33
2.8 TERMINAL IDENTIFI CATION AND DESCRIPTION 2.8.1 MAIN TERMINAL 1. RADIO RECEIVER LOW VOLTAGE COMMON 2. RADIO RECEIVER FULL OPEN INPUT 3. RADIO RECEIVER 24 VAC POWER – 250-ma MAX 4. FULL OPEN / CLOSE INPUT When gate is closed, input w ill open gate to full position. When gate is open and auto clo se timer is turned on, input will re-set and hold[...]
-
Página 34
2.8.2 AUXILIARY TERMINAL The auxiliary terminal is located on the 4602 circuit b oard just to the right of main terminal s 8 and 9. Auxiliary terminals are numbered 1 through 5 with the first terminal at the top. 1. OPEN PHOTO-BEAM This input is only active when the gate is in the opening cycle. An open photo-beam input during the opening cycle wil[...]
-
Página 35
SECTION 3 - ADJUSTMENTS The switch settings and adjustments in this chapte r should be made after your installation and wiri ng to the operator(s) is comp lete. Whenever any of the programming switche s on the circuit board are changed, power must be shut-off, and then turned back on for the new setting to take effect. 3.1 CIRCUIT BOARD ADJUSTMENTS[...]
-
Página 36
3.2 SWITCH SETTINGS The two DIP-switches located on th e circuit board are used to p rogram the operator to operate i n various modes and to turn on or off various op erating features. When ever a switch setting is changed, power to the o perator must be turn ed OFF and then turned back o n for the new setting to take affect. Check and review ALL s[...]
-
Página 37
3.2.1 SW 1 (LEFT SWITCH) DESCRIPTION AND FUNCTION Sw it ch 1 : Set so that the operator cycles open u pon initial power up and open command. If the operator cycles close, turn power o ff and change the setting on this switch. Sw it ch 2 : Turns the auto close timer on or off. Set from 1 to 23 seconds. Sw it ch 3 : This switch should b e left in the[...]
-
Página 38
3.3 AUTOMATIC LIMIT ADJUSTMENT This gate operator does n ot use any mechanical limit switches or run timers to adjust the open and close positions of th e gate. The gate op en and clos e po sitions are determined by the physical stops (or chain stops) of the gate. The gate operator w ill automatically measure the gate and will set its "limits&[...]
-
Página 39
3.4 INHERENT REVE RSE ADJUSTMENT This vehicular gate operator is equipped with a n in herent (Type A) entrapment sensing system. This system will sense an obstru ction in either the opening or clos ing gate cycles and will cause the gate to reverse direction should an obst ruction be encounte red. For this sy stem to function correctly, the gate mu[...]
-
Página 40
3.4.2 CLUTCH ADJUSTMENT In addition to the reverse sensitivity adjustment, this operator is equipped with a mech anical slip clutch to further re duce the possibility of injury should an entrapment occur. Do not over tighten the clutch in this gate operator to compensate for a damag ed or poorly constructed g ate, or to compensate for a gate that i[...]
-
Página 41
SECTION 4 – OPERA TING INSTRUCTIONS WARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIO NS. 2. Never let children ope rate or play with gate controls. Keep the remote cont rol away from children. 3. Always keep people and o bjects away from gate. NO ONE SHO ULD CROSS THE PATH OF THE MOVING GATE 4. Test the operator [...]
-
Página 42
4.2 SHUTDOWN CONDITIONS Under various entrapme nt conditions the operator will assume eith er a soft or hard shutdown (alarm) condition. To determine what type of reset acti on is required, y ou will nee d to understand how the different entrapment conditions affect the gate ope rator. 4.2.1 SOFT SHUTDOWN This occurs in various situations where the[...]
-
Página 43
4.2.3 HARD SHUTDOWN A hard shutdown condition occu rs when the inhe rent entrapme nt protection system has sensed two consecutive obstructions before the gate rea ches the full open or full closed position. • Example: The gate is closing and the inhe rent entrapment protection system senses an obstruction and causes th e gate to reverse direction[...]
-
Página 44
4.3 MANUAL / EMERGE NCY GATE OPERATION This operator is equi pped with a manual releas e system that will allow th e gate to be pushed open in the event of a power outage or equipment failure. There are two manual release system s that are available on this gat e ope rator. The standard type release is the FAIL-SAFE system (req uired by many city c[...]
-
Página 45
4.3.3 FAIL-SECURE MANUAL OPERATION The FAIL-SECURE option locks the gate whe n prim ary (AC) power is removed and requires a keyed release to place the gate in manual operation. Th e FAIL-SECURE option is typically used in CLASS III and CLASS IV applications. • Be sure that primary (AC) and backup (DC) powe r is removed o r shut-off prior to plac[...]
-
Página 46
36[...]
-
Página 47
SECTION 5 – MAINTENANCE AND TROUBLESHOOTING Inspection and service of this gate op erator by a qualified technici an should be performed a nytime a malfunction is observed or suspected. High cycl e usa ge may require more frequent service checks. 5.1 MAINTENANCE When servicing the gate operator, alwa ys check any secondary (external ) reversing d[...]
-
Página 48
5.2 TROUBLESHOOTING Have a good VOM meter to che ck voltages and continuity. A Meg-Ohm meter cap able of checking up to 500 meg-ohms of re sistance is necessary to properly check the integrity of the gro und loops. When a malfunction occurs, isolate the problem to one of three areas: 1) the operator, 2) the loop system, 3) the key ing device s. Use[...]
-
Página 49
Gate opens a short distance, then stops and reverses. • Check that the clutch is adjusted properly and is not slipping. • Disconnect the gate from the gate operator and check that the ga te slides freely without any binding. • Re-adjust the reverse sensitivity. • Check the COUNTER LEDs on the circuit board. The y should blink as the operato[...]
-
Página 50
MOTOR / BELT ACCESS To gain access to the insi de of the gate operator, loosen the two bolts on each side of the electrical panel at the bottom. The entire panel can then swing up for ea sy access into the operator. CAUTION!! Be sure po w er is OFF before accessing the inside of the oper ator. Be sure that the electrical panel is secured in the up [...]
-
Página 51
5.3 ACCESSORIES The following accessory items can be used with the m odel 9100 slide gate operator. Contact Sensor Contact sensor s for use as a secondary ent rapment protection devi ce. Miller Edge, Inc. ME120, ME 123, MG020, MGR20, MGS20 Photo Cell Non-contact (photo cells) sens ors for use as a secondary entrapm ent protection device. Compliant [...]
-
Página 52
1/2 HP Motor Motor Capacitor Resistor Resistor Red Blue Power Switch White Black Lock Solenoid Green Brown Circuit Board High Voltage Terminals Blue Blue Red Red White Black Black White White Black Convenience Outlets Ground 115 VAC Power White Black Green 115 VAC 1/2 HP Main Terminals 11 12 18 Reset Switch Entrapment Alarm 42[...]
-
Página 53
43 43[...]