Ei Electronics Carbon Monoxide Alarm Ei220EN manual
- Consulta online o descarga el manual de instrucciones
- 32 páginas
- 0.27 mb
Ir a la página of
manuales de instrucciones parecidos
-
Smoke Alarm
Ei Electronics Ei151TL
1 páginas 0.13 mb -
Smoke Alarm
Ei Electronics Ei146
2 páginas 0.1 mb -
Smoke Alarm
Ei Electronics Ei186
2 páginas 0.19 mb -
Smoke Alarm
Ei Electronics Ei261DENRC
34 páginas 0.29 mb -
Smoke Alarm
Ei Electronics Ei261ENRC
34 páginas 0.29 mb -
Smoke Alarm
Ei Electronics Ei220EN
32 páginas 0.26 mb -
Smoke Alarm
Ei Electronics EI 127
2 páginas 0.08 mb -
Smoke Alarm
Ei Electronics RadioLINK Ei 407
2 páginas 0.06 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Ei Electronics Carbon Monoxide Alarm Ei220EN. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Ei Electronics Carbon Monoxide Alarm Ei220EN o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Ei Electronics Carbon Monoxide Alarm Ei220EN se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Ei Electronics Carbon Monoxide Alarm Ei220EN, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Ei Electronics Carbon Monoxide Alarm Ei220EN debe contener:
- información acerca de las especificaciones técnicas del dispositivo Ei Electronics Carbon Monoxide Alarm Ei220EN
- nombre de fabricante y año de fabricación del dispositivo Ei Electronics Carbon Monoxide Alarm Ei220EN
- condiciones de uso, configuración y mantenimiento del dispositivo Ei Electronics Carbon Monoxide Alarm Ei220EN
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Ei Electronics Carbon Monoxide Alarm Ei220EN no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Ei Electronics Carbon Monoxide Alarm Ei220EN y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Ei Electronics en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Ei Electronics Carbon Monoxide Alarm Ei220EN, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Ei Electronics Carbon Monoxide Alarm Ei220EN, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Ei Electronics Carbon Monoxide Alarm Ei220EN. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
BS EN 50291: 2001 MAINS MAINS POWERED POWERED Model Ei 225EN Model Ei 220EN - HARD WIRED T O MAINS - WITH PO WER CORD MAINS PO WERED CARBON MONO XIDE ALARM Read and retain carefully f or as long as the product is being used. It contains vital inf or mation on the operation and installation. The leaflet should be regarded as par t of the product. If[...]
-
Página 2
3 4 5 11 15 19 20 22 24 26 28 28 30 1 2 3 4 5 6 7 8 9 10 11 12 13 READ THIS FIRST WHA T T O DO WHEN THE CO ALARM SOUNDS CARBON MONO XIDE - THE SILENT KILLER! WHERE T O PLA CE CARBON MONO XIDE ALARMS INST ALLING Y OUR CARBON MONO XIDE ALARMS TESTING Y OUR CARBON MONO XIDE ALARMS MAINT AINING CARBON MONO XIDE ALARMS LIMIT A TIONS OF CARBON MONO XIDE [...]
-
Página 3
1. READ THIS FIRST W ARNING: The Ei225EN Alar m should be permanently wired to the mains by a qualified electrician in accordance with IEE wir ing regulations (BS7671). The Ei220EN is just plugged in to the mains. Install the Carbon Mono xide Alar m (CO Alar m) in e v er y room that contains a fuel burning appliance, par ticularly rooms where peopl[...]
-
Página 4
When the CO Alar m detects abnormal lev els of CO (abov e 50ppm CO) the red light star ts to flash and the horn will sound within 90 minutes. At higher le vels of CO the alar m will turn on sooner (see table B - page 9). The CO Alar m will automatically reset once the CO has cleared. Pressing the test/hush button resets the CO Alarm immediately (be[...]
-
Página 5
(5) Ring your gas or other fuel supplier on their emergency n umber . K eep the number in a prominent place . (6) Do not re-enter the proper ty until the alarm has stopped. (If the alar m has been silenced by pressing the test/hush b utton, wait at least 5 minutes so the alarm can check that the CO has cleared). (7) Do not use the fuel appliances a[...]
-
Página 6
(CO) poisoning. CO is an invisible , odour less , tasteless and extremely to xic gas. It is produced by appliances and v ehicles burning fuels, such as coal, oil, natural/bottled gas, paraffin, w ood, petrol, diesel, charcoal etc. CO is absorbed by red b lood cells in the lungs in pref erence to oxygen - this results in rapid damage to the heart an[...]
-
Página 7
7 Mild Exposure : Slight headache, nausea, v omiting, fatigue (often described as “flu-like” symptoms). Medium Exposure : Se vere throbbing headache , drowsiness, confusion, f ast hear t rate . Extreme Exposure : Unconsciousness, con vulsions, cardiorespiratory failure, death. A high le vel of CO f or a shor t period (e.g. 350 ppm CO f or 30 mi[...]
-
Página 8
T able A: Effects of Carbon Mono xide P oisoning 35 The maximum allow able concentration f or continuous exposure in any 8 hour period according to OSHA *. 150 Slight headache after 1.5 hours. 200 Slight headache, f atigue, dizziness, nausea after 2-3 hours. 400 F rontal headaches within 1-2 hours, life threatening after 3 hours , also maximum par [...]
-
Página 9
T able B shows ho w the CO Alar m reacts to diff erent lev els of CO gas and exposure time . At higher le vels of CO the alarm tur ns on sooner . The rate of flashing of the red light indicates the le vel of CO . T able B: CO Alarm Response * unless it has been in alarm (see CO Alarm Memory below) If y our CO Alarm sounds follow the instructions on[...]
-
Página 10
(Without this f eature the CO lev el would need to be at 50ppm CO f or 90 minutes for an indication to be giv en). Note the Pre-Alar m signal ma y be tr iggered b y CO coming f or example , from cooking with gas, from car engines or from nearby barbecues . This is usually not a concer n unless the Pre-Alarm signal persists until the alar m sounds a[...]
-
Página 11
4. WHERE T O PLA CE CO ALARMS 3.1 Ideally a Carbon Mono xide Alar m should be installed in: - Ev er y room containing a fuel burning appliance, and - Remote rooms where occupants spend a considerab le amount of time - Ev er y bedroom. How ev er if the number of Carbon Mono xide Alar ms is limited the f ollowing points should be considered when deci[...]
-
Página 12
(2) Outside the building. (3) In an enclosed space (e.g. in or below a cupboard). (4) In a damp or humid area. (5) Directly abov e a sink or cooker . (6) Ne xt to a door , window , air vent or an ywhere that it would be affected b y draughts. (7) Ne xt to an extractor f an. (8) Where it would be obstructed, e.g. by cur tains or furniture. (9) In an[...]
-
Página 13
13 • The CO alarm should be a hor izontal distance of betw een 1m and 3m from the potential CO source. • If there is a par tition in the room, the CO alarm should be located on the same side of the par tition as the potential source. • In rooms with sloped ceilings, the CO alarm should be located at the high side of the room (see fig 3). 300m[...]
-
Página 14
3.31 If locating the CO alarm in a bedroom or in r ooms remote from a fuel burning appliance (see figure 4) • Mount the CO alar m relativ ely close to the breathing zone of the occupants . Whate ver position is chosen mak e sure it is possible to view the three light indicators , when in the vicinity of the alar m. 14 CO Alarm about 1 to 2m Figur[...]
-
Página 15
5. INST ALLING Y OUR CARBON MONO XIDE ALARMS The Alar m is designed to be permanently mounted. The unit can be screw ed directly to the wall or ceiling and connected to the mains . It requires a current of 60mA. The Alar m m ust not be exposed to dripping or splashing. There are impor tant markings on the underside of the alar m. IMPORT ANT PRECA U[...]
-
Página 16
INST ALLA TION PROCEDURE Ei225EN (Only) W arning: The CO alar m should be installed b y a qualified electr ican in accordance with the IEE wiring regulations (BS 7671). F ailure to install this alar m correctly ma y expose the user to shock or fire hazards . Procedure: 1. Select a location complying with the abov e advice. 2. Disconnect the A C mai[...]
-
Página 17
6. The Brown wire (terminal 3) must be connected to the house wiring coloured brown or to a house terminal mar k ed “L ”. The Blue wire (ter minal 4) must be connected to the house wiring coloured blue or to a house terminal mar k ed “N”. The alar m does not need to be earthed, howe ver f or conv enience a spare ter minal (no . 5) is provid[...]
-
Página 18
Ei220EN (Only) 1. Slide the cov er off as shown in Figure 7 to e xpose the mounting screw holes . 2. Cut a notch in the back side wall (on the centre of either side or at the bottom, f or the pow er cord) to allow the unit to lie flush against the ceiling/wall. 3. Mark the two screw locations . Dr ill suitab le holes (6mm dr ill) then inser t the p[...]
-
Página 19
6. TESTING Y OUR CO ALARM (1) Regularly check that the green mains po wer light is on. The unit cannot detect CO if the mains pow er is not on. (If it is off check circuit break ers, fuses, wiring etc). (2) T est the unit weekly by pressing the test/hush b utton. Hold the test button (f or up to 10 seconds) until the hor n sounds f or ov er 5 secon[...]
-
Página 20
inject the CO gas into the gas entr y holes , see Figure 1. When it senses the CO it flashes the red light (as per T able B) to confirm that is detecting CO gas. How to distinguish between CO Alarm and Smoke Alarm W arnings The CO Alar m has a distinctiv e on-off sound of 3 pulses, f ollowed b y a pause as compared with a typical Smoke Alarm which [...]
-
Página 21
Remov e the CO Alar m when decorating. Do not allow water or dust to contaminate the alar m. W arning : Do not open or tamper with the CO Alar m. There are no user ser viceable par ts. This can damage the unit and may e xpose the user to shock or fire hazards . END OF LIFE When the unit has completed up to 6 years of oper ation the amber light will[...]
-
Página 22
3. Unscre w the ter minal cov er screw . 4. Disconnect the wires from the terminal block and mak e saf e, par ticularly if the circuit is going to be tur ned on again after the CO Alarm is remov ed. 5. Unscre w from the wall. Ei220EN only 1. Unplug the unit. 2. Slide cov er up as shown in figure 7. 3. Unscre w from the wall. 8. LIMIT A TIONS OF CO [...]
-
Página 23
(3) The CO Alarm may not be heard. The sound output is loud but it ma y not be heard behind a closed door or if it is too f ar awa y . The Alar m ma y not wak e up somebody who has taken alcohol or drugs. The alarm sound may be mask ed by other sounds such as T .V ., stereo , traffic noise etc. Fitting CO Alar ms on either side of closed doors will[...]
-
Página 24
THE A CUTE EFFECTS OF CARBON MONO XIDE EXPOSURE. IT WILL NO T FULL Y SAFEGU ARD INDIVIDU ALS WITH SPECIFIC MEDICAL CONDITIONS. IF IN DOUBT CONSUL T A MEDICAL PRA CTITIONER. 9. HO W T O PRO TECT Y OUR F AMIL Y F ollow these guidelines to reduce the risk of Carbon Monoxide poisoning. (1) Know and look out f or tell-tale signs that Carbon Mono xide ma[...]
-
Página 25
air comes from and ensure v ents/air br ic ks etc. remain unobstr ucted (par ticularly after building w or k). (4) The appliances must also “breathe out” the waste gases (including the CO) – usually through a flue or chimney . Ensure chimneys and flues are not b locked or leaking, and get them check ed ev er y y ear . Check f or excessiv e r [...]
-
Página 26
10. TECHNICAL SPECIFICA TION Operating V oltage : 230± 10% V AC , 50Hz P ow er : 1 W att, (60 mA) P ow er on Indicator : Green Light on Sensor : Electrochemical Sensor CO Sensitivity : Meets BS EN 50291: 2001. Unit operates as per T able B (page 9). Electrical Safety : Complies with rele vant sections of EN 60335-1: 1994 Electromagnetic : Complies[...]
-
Página 27
Initialisation Time : 70 seconds. On power up red and amber lights flash momentarily to show they are oper ational. Operating T emperature : -10°C to 40°C Humidity Range : 15% to 95% R.H. (non-condensing) A udible Alarm : 85dB(A) at 3m minimum Self Diagnostics : H o rn beep and amber fault light flashes e very 40 seconds if a sensor f ault is fou[...]
-
Página 28
Dimensions : 135 x 105 x 71 mm. W eight : 195g - Ei225EN 290g - Ei220EN 11. GETTING THE CO ALARM SER VICED If your CO Alarm f ails to wor k after y ou hav e carefully read all the instr uctions , checked the unit has been installed correctly , and is receiving AC po wer , - see “How to disconnect and remov e the Alar m” in section 7, page 20. R[...]
-
Página 29
This guarantee e xcludes incidental and consequential damage. If this Carbon Mono xide Alar m should become def ective within the guarantee period, it must be retur ned to where it w as purchased or alter nativ ely to Ei Electronics., carefully packaged, with the prob lem clearly stated. (see section 11 “Getting the CO Alarm Ser viced”) along w[...]
-
Página 30
13. TROUBLESHOO TING 1. ALARM DOES NO T WORK WITH THE TEST BUTT ON: (1) Check that the g reen mains power light is on. If it is off check the wiring, fuse, circuit breakers etc. (2) Hold the test button do wn for at least 5 seconds . 2. ALARM BEEPS AND AMBER LIGHT FLASHES EVER Y 40 SECONDS: If the alar m beeps and the amber f ault light flashes e v[...]
-
Página 31
(2) Ensure there are no fumes in the area (e.g. paint, thinners, alcohol, hair spra y , chemical cleaners aerosol spra ys etc). (3) Ensure there is no outdoor source of CO in the vicinity (e.g. a car with engine running, heavy traffic , heavy air pollution, barbecue fumes etc). (4) Press the test/hush button to silence the alarm. If the unit contin[...]
-
Página 32
PRODUCT DISPOSAL Ei Electronics Shannon, Co . Clare, Ireland. T el: (061) 471277 F ax: (061) 471053 E-mail. helpdesk@eiltd.ie www .eielectronics.com Aico Ltd. Mile End Business P ark, Maesbur y Rd, Os westr y , Shropshire, SY10 8NN, U .K. T el: 0870 7584000 F ax: 0870 7584010 E-mail: suppor t@aico .co .uk www .aico.co .uk © Ei Electronics 2005 P/N[...]