Emerson Process Management 3051 manual
- Consulta online o descarga el manual de instrucciones
- 28 páginas
- 3.85 mb
Ir a la página of
manuales de instrucciones parecidos
-
Pacemaker
Emerson Process Management 2400S
208 páginas 2.33 mb -
Pacemaker
Emerson Process Management 00809-0200-4088
8 páginas 0.45 mb -
Pacemaker
Emerson Process Management Rev AA
8 páginas 0.45 mb -
Pacemaker
Emerson Process Management Model 2700
204 páginas 4.69 mb -
Pacemaker
Emerson Process Management MSP900SH
16 páginas 0.47 mb -
Pacemaker
Emerson Process Management 3051CF
28 páginas 3.85 mb -
Pacemaker
Emerson Process Management Rosemount 8732em
4 páginas 1.1 mb -
Pacemaker
Emerson Process Management 3051
28 páginas 3.85 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Emerson Process Management 3051. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Emerson Process Management 3051 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Emerson Process Management 3051 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Emerson Process Management 3051, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Emerson Process Management 3051 debe contener:
- información acerca de las especificaciones técnicas del dispositivo Emerson Process Management 3051
- nombre de fabricante y año de fabricación del dispositivo Emerson Process Management 3051
- condiciones de uso, configuración y mantenimiento del dispositivo Emerson Process Management 3051
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Emerson Process Management 3051 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Emerson Process Management 3051 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Emerson Process Management en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Emerson Process Management 3051, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Emerson Process Management 3051, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Emerson Process Management 3051. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
Quick Start Guide 00825-0100-4007, Rev CB February 2015 Note Bef ore installin g the transmitt er , con firm the c orrect Devic e Drive r is loaded on the host systems. See page 3 for Syst em R eadine ss. R osemount 3051 Pressure T ransmitt er and R osemount 3051CF Series Flowmet ers with 4-20 mA HART ® Re vision 5 and 7 prot ocol[...]
-
Página 2
February 2015 2 Quick Start Guide NO TICE This guide provi des basic guide lines f or Rose mount 305 1 T ransmitters. It doe s not provide instructions for con figuration, diagnostics, m ainte nance , service , troublesh ooting, Explo sion-proof , Flameproof , or intrinsically sa fe (I.S.) inst alla tions. Ref er to the R osemount 3051 HA RT 7 Re f[...]
-
Página 3
Quick Start Guide 3 February 2015 System re adiness Confirm HART R evision capability If using HART based control or asset management systems, please confirm the HART capability of those systems prior to transmitte r instal lation. Not all systems are capa ble of communicating with HART Revision 7 pro tocol. This transmitter can be configured f[...]
-
Página 4
February 2015 4 Quick Start Guide T ransmitt er installation St ep 1: Mount the transmitter Liquid applications Coplanar In-line 1. Plac e taps t o the side o f the line . 2. Mount besid e or below th e taps. 3. Mount the transmitter so that the drain/vent valves are oriented up ward. Ga s applications 1. Plac e taps in the top or side of the line.[...]
-
Página 5
Quick Start Guide 5 February 2015 Figure 1. Panel and P ipe Mounting Panel m ount (1) 1. 1. 5 / 16 ⫻ 1 1 / 2 Panel Bolts are cu stomer supp lied. Pipe mount Coplanar fl ange T raditional f lange Rosemount 3051T[...]
-
Página 6
February 2015 6 Quick Start Guide Bolting consider ations If the transmi tter installation re quires assembly of th e process flanges, ma nifolds, or flange adapt ers, follow the assembly guide lines to ensure a tight seal for optimal performa nce characteris tics of the transmit ters. Use only bolts su pplied with the transm itter or sold by Emers[...]
-
Página 7
Quick Start Guide 7 February 2015 In-line gage transmitt er orientation The low side pressure port (atmospher ic refere nce) on the in-line gage transmitter is located in the neck of t he transmitter, behind the housing. The vent path is 360° arou nd the transmitter bet ween the housi ng and sensor. (See Figur e 3 .) Keep the vent pa th free of an[...]
-
Página 8
February 2015 8 Quick Start Guide St ep 2: Consider housing rotation To improve field ac cess to wiring or to better view the optional L CD display: 1. Loosen the housing rotati on set scre w using a 5/64-in. hex wre nch. 2. T ur n the housing lef t or right maximum up to 18 0° from its o riginal position (1) . Please note that over rot ati ng c a[...]
-
Página 9
Quick Start Guide 9 February 2015 Figure 5. T ransmitter Electronics Board A. A l ar m B. Security St ep 4: Connec t the wiring and power up Figure 6. T ransmitter Wiring Diagrams (4–20 mA) A. 24 Vdc supply B. R L ≥ 250 C. Current Meter (Optional) Shielded twiste d pair cable should be used for best resu lts. Use 24 AWG or larger wire that does[...]
-
Página 10
February 2015 10 Quick Start Guide 3. Ground hou sing t o fulfill local grounding regu lation s. 4. Ensure prope r grounding . It is important that the instrume nt cable shield : a. Be trimmed close and insulated from touching the transmitter hou sing b. Be c onnec ted to the next shield if cable is routed through a junction box c. Be connec ted to[...]
-
Página 11
Quick Start Guide 11 February 2015 St ep 5: V erif y configur ation Verify the config uration using any HA RT capable c onfiguration tool or Local Operator Interface ( LOI) - option code M4. Confi guration instructions for a Field Communicator and LOI are incl uded in this step. See Rosemount 3051 reference manual (008 09-0100-4007) for con figurat[...]
-
Página 12
February 2015 12 Quick Start Guide V erif ying co nfigura tion with Local Ope rat or Int erface (L OI) The optional LO I can be used for commission ing the device. The LOI is a two button design with internal and external bu ttons. The internal buttons a re located on the display o f the transmitter, while the extern al buttons are loca ted underne[...]
-
Página 13
Quick Start Guide 13 February 2015 Note See Figure 10 on page 15 to confirm E xternal Bu tton F unctionality . Figure 9. LOI Menu Swit ch HAR T revision mode If the HART configurat ion tool is not capa ble of communic ating with HART Revision 7, the 305 1 will load a generic men u with limited cap ability. The following procedures will switch the H[...]
-
Página 14
February 2015 14 Quick Start Guide St ep 6: T rim the transmitter Devices are calibra ted by the factory. Once in stalled, it is recommended to perform a zero trim on g age and differentia l pressure transmitters to el iminate error due to mounting position or static pressure effe cts. A zero trim can be performed using e ither a Field Commu nicato[...]
-
Página 15
Quick Start Guide 15 February 2015 T rimming with configuration buttons A zero trim is to be perform ed using one of the three possib le sets of external configuration butto ns located under the top tag. To access the con figuration butt ons, loosen the screw a nd slide the ta g on the top of the transmitter. Confirm the fun ctionality using Figure[...]
-
Página 16
February 2015 16 Quick Start Guide Safet y instrum ented systems installation For Safety Certified in stallations, re fer to product manua l (00809-0100- 4007) for installation procedure a nd system requirements.[...]
-
Página 17
Quick Start Guide 17 February 2015 Produc t Cer tific ations European Direc tive Information A copy of the EC Declarat ion of Conformity can be fou nd at the end of the Quick Start Guide. The most recent revision of the EC Declar ation of Conformity can be found at www.rosemount.com. O rd in ary Lo ca ti on Ce rti fi c ation from FM Approvals As st[...]
-
Página 18
February 2015 18 Quick Start Guide Europe E8 A TE X Flameproof and Du st Certificate: KEMA00A TE X2013X; Baseefa11A TE X0275X Standar ds: EN60079-0:2012, E N60079-1:2007, EN6007 9-26:2007, EN60079-31:2009 Marking s: II 1/2 G Ex d IIC T6/T5 Ga /Gb, T6(- 50 °C ≤ T a ≤ +65 °C), T5(-50 °C ≤ T a ≤ +80 °C); II 1 D Ex ta IIIC T95 °C T 500 105[...]
-
Página 19
Quick Start Guide 19 February 2015 N1 AT E X Ty p e n a n d D u s t Certificate: BAS00A TE X3105X; Baseefa11A TE X0275X Standards : EN60079-0:2012, EN60079 -15:2010, EN60079-31:20 09 Markings : II 3 G Ex nA IIC T5 Gc (–40 °C ≤ T a ≤ +70 °C); II 1 D Ex ta IIIC T95 °C T 500 105 °C Da (-20 °C ≤ T a ≤ +85 °C) Special Condition s for Saf[...]
-
Página 20
February 2015 20 Quick Start Guide Special Condition s for Safe Use (X ): 1. If the apparatus is fitted with op tional 90 V transient suppressor , it is not capable of withstanding the 500 V insulation te st required by IEC60079-11. This must be take n into acc ount when installin g the apparatus. 2. The enclosure m ay be made of aluminum alloy and[...]
-
Página 21
Quick Start Guide 21 February 2015 2. In case of re pair , contact the manufac turer for inf ormation on the dimensions o f the flameproof joints. 3. The capacitance of the wrap around label, be ing 1.6 nF , exceeds the limit in T able 9 of ABNT NBR IE C 60079-0. The user sh all dete rmine suitabilit y for the specific application. I2 INMETRO Intri[...]
-
Página 22
February 2015 22 Quick Start Guide Japan E4 Japan Flameproo f Certificate: T C20577, T C20578, T C20583, TC20584 Marking s: Ex d IIC T5 T echnical Re gulations C ustoms Union (EAC) EM EAC Flameproof Certificate: R U C-US.Gb05.B.00400 Markings : Ga/Gb Ex d I IC T5/T6 X, T5(-60 °C ≤ T a ≤ +80 °C), T6(-60 °C ≤ T a ≤ +65 °C ) Special Condit[...]
-
Página 23
Quick Start Guide 23 February 2015 Special Condition s for Safe Use (X): 1. When the thread ad apte r is used with an enc losure in t ype of protection increased saf et y “e” the e ntry thread shall be suitably s ealed in orde r to main tain the ingress protection rating (IP) of the enclosure . 2. The blanking plug shall not be u sed with an ad[...]
-
Página 24
February 2015 24 Quick Start Guide Figure 11. Rosemount 3051 EC Declaration of Conformity[...]
-
Página 25
Quick Start Guide 25 February 2015[...]
-
Página 26
February 2015 26 Quick Start Guide[...]
-
Página 27
Quick Start Guide 27 February 2015[...]
-
Página 28
Rosemount W orld Headquarters Emerson Process Management 6021 Innovation Blvd Shakopee, MN 553 79, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RFQ.RMD-RCC@EmersonProcess.com North America Regional Offic e Emerson Process Management 8200 Market Blvd. Chanhassen, MN 553 17, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RMT-NA.RCCR[...]