First Alert First Alert Professional Security System manual
- Consulta online o descarga el manual de instrucciones
- 44 páginas
- 0.22 mb
Ir a la página of
manuales de instrucciones parecidos
-
Home Security System
First Alert FA1600C
80 páginas 0.42 mb -
Home Security System
First Alert FA168C
16 páginas 0.32 mb -
Home Security System
First Alert First Alert Professional Security System
44 páginas 0.22 mb -
Home Security System
First Alert 2074EF
8 páginas 4.59 mb -
Home Security System
First Alert FA148CP-CN
56 páginas 0.57 mb -
Home Security System
First Alert FA1600C/CA/CB
80 páginas 0.48 mb -
Home Security System
First Alert FA1220CV
60 páginas 0.26 mb -
Home Security System
First Alert FA210RF
1 páginas 0.03 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones First Alert First Alert Professional Security System. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica First Alert First Alert Professional Security System o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual First Alert First Alert Professional Security System se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales First Alert First Alert Professional Security System, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones First Alert First Alert Professional Security System debe contener:
- información acerca de las especificaciones técnicas del dispositivo First Alert First Alert Professional Security System
- nombre de fabricante y año de fabricación del dispositivo First Alert First Alert Professional Security System
- condiciones de uso, configuración y mantenimiento del dispositivo First Alert First Alert Professional Security System
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de First Alert First Alert Professional Security System no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de First Alert First Alert Professional Security System y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico First Alert en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de First Alert First Alert Professional Security System, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo First Alert First Alert Professional Security System, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual First Alert First Alert Professional Security System. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
USER'S MANUAL FA142C Security System N7229–1V2 Rev B 4/99 Previous Menu[...]
-
Página 2
–2– TABLE OF CONTENTS SYSTEM OVERVIEW ...................................................................................... 3 General.......................................................................................................... 3 Keypads................................................................................................[...]
-
Página 3
–3– SYSTEM OVERVIEW General Congratulations on your ownership of a First Alert Professional Security System. You've made a wise decision in choosing it, for it represents the latest in security protection technology today, including microcomputer technology to monitor all system status. Basically, this system offers you three forms of prot[...]
-
Página 4
–4– SYSTEM OVERVIEW Fire Protection The fire protection portion of your security system (if used) is always on and will sound an alarm if a fire condition is detected. Refer to the FIRE ALARM SYSTEM section for important information concerning fire protection, smoke detectors and planning emer- gency exit routes from your house. Alarms When an [...]
-
Página 5
–5– ABOUT THE KEYPADS General Your keypad(s) (see page 7) allow you to control all system functions. The keypads feature a telephone style (digital) keypad and a Liquid Crystal Display (LCD) which shows the nature and location of all occurrences. The keypads feature a built-in sounder which emits alarm sounds during alarm conditions and produce[...]
-
Página 6
–6– ABOUT THE KEYPADS Fixed-Word Keypad Displays AWAY All burglary zones, interior & perimeter, are armed. STAY Perimeter burglary zones, such as windows and doors are armed. INSTANT Perimeter burglary zones armed and entry delay is turned off. BYPASS One or more burglary protection zones have been bypassed. NOT READY Appears when burglary [...]
-
Página 7
–7– ABOUT THE KEYPADS KEYPADS WITH FLIP-DOWN KEY COVERS ARE SHOWN WITH COVER REMOVED ARMED READY Professional OFF AWAY STAY MAXIMUM TEST BYPASS INSTANT CODE CHIME READY 1 A B C D 2 3 4 5 6 7 8 9 * 0# First Alert First Alert ® READY Professional OFF AW A Y STA Y MAXIMUM TEST BYP ASS INST ANT CODE CHIME READY P ANIC 1 2 3 4 5 6 7 8 9 * 0 # ARMED[...]
-
Página 8
–8– FUNCTIONS OF THE KEYPAD SEE TYPICAL ALPHA KEYPAD ON NEXT PAGE 1. DISPLAY WINDOW. Alpha Keypad: A 2-line, 32- character Liquid Crystal Display (LCD). Displays protection zone identification, system status, and messages (see page 9). Fixed-Word Keypad: Displays protection zone ID and system status messages using pre-designated words (see page[...]
-
Página 9
– 9 – † Note: Keys 1 through 9 each perform their associated companion functions (OFF, AWAY, STAY, etc.) when preceded by an entry of the security code (as described later). IMPORTANT! : When entering codes and commands, se- quential key depressions must be made within 2 seconds of one another. If 2 seconds elapses without a key depression, t[...]
-
Página 10
–10– SECURITY CODES General At the time of installation, your installer programmed a personal four-digit Master code, known only to you and yours. This code is used to perform most system functions, including arming and disarming of the system. As an additional safety feature, up to 4 temporary User Codes can be assigned for use by those not ha[...]
-
Página 11
–11– SECURITY CODES (Continued) Duress Code (Continued) If a DURESS code is assigned, check here: - The Duress code may be any 4-digit code assigned to User Number 8. To program a Duress code: Enter your Master Code + 8 + 8 + [desired 4-digit duress code]. The keypad will beep once. Note: The Duress code must differ from the Master Code or any [...]
-
Página 12
–12– ENTRY/EXIT DELAYS General Information Your system has preset time delays, known as exit delay and entry delay. When you arm your system, exit delay gives you time to leave through the entry/exit door without setting off an alarm. Entry delay gives you time to disarm the system when you reenter through the entry/exit door. The system must b[...]
-
Página 13
–13– CHECKING FOR OPEN ZONES Using the ✱ READY Key Before arming your system, all protected doors, windows and other protection zones must be closed or bypassed (see BYPASSING PROTECTION ZONES section), otherwise the keypad will display a "Not Ready" message, and your keypad’s READY indicator light will not be lit. The READY ( ✱[...]
-
Página 14
–14– BYPASSING PROTECTION ZONES Using the 6 BYPASS Key LIMITATION The system will not allow fire zones to be bypassed. All bypasses are removed when an OFF sequence (security code plus OFF) is performed. This key is used when you want to arm your system with one or more zones intentionally unprotected. The system must be disarmed first. 1 . Ent[...]
-
Página 15
–15– BYPASSING PROTECTION ZONES (Continued) Quick Bypass Ask your installer if "Quick Bypass" is active for your system, and determine which box(es) you should check here. → If your system supports "Quick Bypass", it allows you to easily bypass zones as checked below, without having to enter zone numbers individually. This[...]
-
Página 16
–16– ARMING PERIMETER ONLY WITH ENTRY DELAY ON Using the 3 STAY Key BEFORE ARMING, make sure all doors and windows are closed. Refer to CHECKING FOR OPEN ZONES on page 13. Use this key when staying inside, but expect someone to use an entry/exit door later. 1 . Enter your security code and press the STAY key. 2 . The keypad beeps three times an[...]
-
Página 17
–17– ARMING PERIMETER ONLY WITH ENTRY DELAY OFF Using the 7 INSTANT Key BEFORE ARMING, make sure all doors and windows are closed. Refer to CHECKING FOR OPEN ZONES on page 13. THE INSTANT MODE ARMS THE PERIMETER (INCLUDING THE ENTRY/ EXIT DOOR), WITH NO ENTRY DELAY. PERSONS WITHIN THE PREMISES CAN MOVE ABOUT FREELY Use this key when staying ins[...]
-
Página 18
–18– ARMING ALL PROTECTION WITH ENTRY DELAY ON Using the 2 AWAY Key BEFORE ARMING, make sure all doors and windows are closed. Refer to CHECKING FOR OPEN ZONES on page 13. Use this key when no one will be staying inside. 1 . Enter your security code and press the AWAY key. 2 . The keypad beeps twice and displays the armed message. The red ARMED[...]
-
Página 19
–19– ARMING ALL PROTECTION WITH ENTRY DELAY OFF Using the 4 MAXIMUM Key BEFORE ARMING, close all doors and windows (see CHECKING FOR OPEN ZONES on page 13) U se this key when the premises will be vacant for extended periods of time such as vacations, etc., or when retiring for the night and no one will be moving through protected interior areas[...]
-
Página 20
–20– DISARMING THE SYSTEM AND SILENCING ALARMS Using the 1 OFF Key IMPORTANT: If you return and the main burglary sounder is on, DO NOT ENTER, but CONTACT THE POLICE from a nearby safe location. If you return after an alarm has occurred and the main sounder has shut itself off, the keypad will beep rapidly upon your entering, indicating that an[...]
-
Página 21
–21– EXIT ALARMS Exit Alarm Warning Displays and Sounds Ask your installer if "Exit Alarm Warning" is active for your system, and if so, check here: Your system may support and have been programmed for this feature. When arming, if an exit or interior zone contains a fault during closing at the time the exit delay ends , the alarm sou[...]
-
Página 22
–22– PANIC KEYS (FOR MANUALLY ACTIVATING SILENT AND/OR AUDIBLE ALARMS) Using Panic Keys Your system may have been programmed to use special keys or combinations of keys to manually activate emergency (panic) functions. The functions that might be programmed are: Silent Emergency, Audible Emergency, Personal Emergency, and Fire. A silent emergen[...]
-
Página 23
–23– PANIC KEYS CHECK IF PANIC P R O G R A M M E D ZONE ACTIVE KEY(S) F U N C T I O N NUMBER [A] ____SILENT, ____AUDIBLE, ____PERSONAL, ____FIRE 9 5 [B] ____SILENT, ____AUDIBLE, ____PERSONAL, ____FIRE 0 7 SEE YOUR INSTALLER [C] ____SILENT, ____AUDIBLE, ____PERSONAL, ____FIRE 9 6 AND NOTE HERE OR THE KEY(S) & FUNCTION(S) [1] & [ ✴ ] __[...]
-
Página 24
–24– TESTING THE SYSTEM TO BE CONDUCTED WEEKLY Using the 5 TEST Key NO ALARM REPORTS WILL BE SENT TO THE CENTRAL MONITORING STATION while the system is in Test mode. The TEST key puts your system into Test mode, which allows each protection point to be checked for proper operation. 1 . Disarm the system and close all protected windows, doors, e[...]
-
Página 25
–25– TESTING THE SYSTEM (Continued) 7 . After all protection points have been checked and restored, there should be no zone identification numbers displayed. If a problem is experienced with any protection point (no confirming sounds, no display), CALL FOR SERVICE IMMEDIATELY. 8 . Turn off the Test mode by entering the security code and pressin[...]
-
Página 26
–26– TROUBLE CONDITIONS "Check" and "Battery" Displays * Not all systems use wireless sensors. T he word CHECK on the keypad's display, accompanied by a "beeping" at the keypad, indicates a trouble condition in the system. To silence the beeping for these conditions, press any key. 1. A display of "CHECK&[...]
-
Página 27
– 27 – TROUBLE CONDITIONS Words or letters in parentheses ( ) are those that are displayed on Fixed-word keypads. [ Other Trouble Displays * Any “beeping” that accompanies a trouble display can be stopped by entering an OFF sequence (code + OFF) ** Not all systems use wireless transmitters. 1. COMM. FAILURE Indicates that a failure has occu[...]
-
Página 28
– 28 – TROUBLE CONDITIONS Other Trouble Displays (Continued) 5. AC LOSS is displayed The system is operating on battery power only due to a (or NO AC ) power failure. If only some lights are out on the premises, check circuit breakers and fuses and reset or replace as necessary. CALL FOR SERVICE if AC power cannot be restored to the system. 6. [...]
-
Página 29
–29– FIRE ALARM SYSTEM (IF INSTALLED) General Your fire alarm system (if installed) is on 24 hours a day, for continuous protection. In the event of an emergency, the strategically located smoke and heat detectors will au- tomatically send signals to your system, triggering a loud, interrupted pulsed sound* from the Keypad(s). This sound will a[...]
-
Página 30
–30– FIRE ALARM SYSTEM (Continued) Manually Initiating a Fire Alarm 1 . Should you become aware of a fire emergency before your detectors sense the problem, go to your nearest Keypad and manually initiate an alarm by pressing the appropriate panic key(s), assigned for FIRE emergency (if programmed by the installer). Check below, and on page 23.[...]
-
Página 31
–31– NATIONAL FIRE PROTECTION ASSOCIATION RECOMMENDATIONS ON SMOKE DETECTORS DINING KITCHEN BEDROOM BEDROOM BEDROOM BEDROOM LIVING ROOM ✪ ✪ ✪ ✪ ✪ ▲ ▲ BEDROOM BDRM BDRM DINING LIVING ROOM TV ROOM KITCHEN ■ ■ ■ ✪ ✪ ✪ ✪✪ ✪ ▲ ✪ ✪ ✪ BEDROOM BEDROOM TO BR ■ ■ ■ ■ ■ LVNG RM BASEMENT KTCHN ▲ ▲ . CLO[...]
-
Página 32
–32– EMERGENCY EVACUATION Steps to Safety • FRONT • BACK • BEDROOM BA TH BEDROOM KITCHEN BACK DOOR 1 FLOOR ST BEDROOM BEDROOM 2 FLOOR ND BA TH BEDROOM PORCH CLOSET Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the National Fire Protection Association: 1 . Plan on your detect[...]
-
Página 33
–33– QUICK GUIDE TO ALARM SYSTEM FUNCTIONS FUNCTION PROCEDURE COMMENTS Check Zones Press READY key. To view faulted zones when system not ready. Arm System Enter code. Press arming key desired: (AWAY, STAY, INSTANT, MAXIMUM) Arms system in mode selected. Quick Arm (if programmed) Press #. Press arming key desired: (AWAY, STAY, INSTANT, MAXIMUM)[...]
-
Página 34
–34– SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS (ALPHA DISPLAY KEYPADS) SOUND CAUSE DISPLAY LOUD, INTERRUPTED* Keypad & External FIRE ALARM FIRE is displayed; descriptor of zone in alarm is displayed. LOUD, CONTINUOUS* Keypad & External BURGLARY/AUDIBLE EMERGENCY ALARM ALARM is displayed; descriptor of zone in alarm is also displayed.. Als[...]
-
Página 35
–35– SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS (FIXED-WORD DISPLAY KEYPADS) SOUND CAUSE DISPLAY LOUD, INTERRUPTED* Keypad & External FIRE ALARM FIRE and ALARM are displayed; protection zone in alarm is displayed. LOUD, CONTINUOUS* Keypad & External BURGLARY/AUDIBLE EMERGENCY ALARM ALARM is displayed; protection zone in alarm is also displ[...]
-
Página 36
–36– PROTECTION ZONES LIST One or more sensing devices will have been assigned by the installer of your alarm system to each of the various protection zones in your system (although not every zone number can be used). For example, the sensing device on your Entry/Exit door may have been assigned to zone 06, sensing devices on windows in the mas[...]
-
Página 37
–37– OWNER'S INSURANCE PREMIUM CREDIT REQUEST This form should be completed and forwarded to your homeowner's insurance carrier for possible premium credit. A . GENERAL INFORMATION: Insured's Name and Address: ____________________________________________________________________________ ____________________________________________[...]
-
Página 38
–38– OWNER'S INSURANCE PREMIUM CREDIT REQUEST (cont.) E . SMOKE DETECTOR LOCATIONS: Furnace Room Kitchen Bedrooms Attic Basement Living Room Dining Room Hall F . BURGLARY DETECTING DEVICE LOCATIONS: Front Door Basement Door Rear Door All Exterior Doors 1st Floor Windows All windows Interior Locations All Accessible Openings, Including Skyl[...]
-
Página 39
–39– CANADIAN DEPARTMENT OF COMMUNICATIONS (DOC) STATEMENT NOTICE The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to th[...]
-
Página 40
–40– UL NOTICE: This is a "Grade A" Residential System. FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statem ent for your information: This equipment generates and uses radio frequency energy and if not [...]
-
Página 41
–41– FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 STATEMENT This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains, among oth er information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the [...]
-
Página 42
–42– WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or ot her emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons. For example: • Intruders ma[...]
-
Página 43
–43– (continued) WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM • Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the other side of closed or partly open doors. If warning devices sound on a different level of the residence from the bedrooms, then they are less likely to wake[...]
-
Página 44
àN7229-1V2"ä N7229–1V2 Rev B 4/99 ONE YEAR LIMITED WARRANTY Pittway Corporation, and its divisions, subsidiaries and affiliates ("Seller"), 165 Eileen Way, Syosset, New York 11791, warran ts its First Alert Professional security equipment (the "product") to be free from defects in materials and workmanship for one year [...]