Generac Power Systems 04390-1 manual
- Consulta online o descarga el manual de instrucciones
- 60 páginas
- 4.69 mb
Ir a la página of
manuales de instrucciones parecidos
-
Portable Generator
Generac Power Systems Transfer Switches and Accessories
15 páginas 1.7 mb -
Portable Generator
Generac Power Systems 0043736, 0046265
64 páginas 4.68 mb -
Portable Generator
Generac Power Systems 005259-1
68 páginas 5.23 mb -
Portable Generator
Generac Power Systems 005818-0
4 páginas 0.45 mb -
Portable Generator
Generac Power Systems Whisper Test 5261
4 páginas 0.3 mb -
Portable Generator
Generac Power Systems SG020
4 páginas 0.23 mb -
Portable Generator
Generac Power Systems 00862-1
52 páginas 2.78 mb -
Portable Generator
Generac Power Systems Air-cooled Industrial Mobile Generator 09843-2
32 páginas 5.65 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Generac Power Systems 04390-1. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Generac Power Systems 04390-1 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Generac Power Systems 04390-1 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Generac Power Systems 04390-1, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Generac Power Systems 04390-1 debe contener:
- información acerca de las especificaciones técnicas del dispositivo Generac Power Systems 04390-1
- nombre de fabricante y año de fabricación del dispositivo Generac Power Systems 04390-1
- condiciones de uso, configuración y mantenimiento del dispositivo Generac Power Systems 04390-1
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Generac Power Systems 04390-1 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Generac Power Systems 04390-1 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Generac Power Systems en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Generac Power Systems 04390-1, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Generac Power Systems 04390-1, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Generac Power Systems 04390-1. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
GENERA C POWER SYSTEMS, INC. R R Installation and Owner’ s Man ual Air -cooled, Prepac kaged A utomatic Standb y Generator s Models: 04389-1 (6 kW NG, 7 kW LP) 04456-1 (12 kW NG, 12 kW LP) 04390-1 (13 kW NG, 15 kW LP) DEADL Y EXHAUST FUMES. OUTDOOR INST ALLA TION ONL Y!! D ANGER Not intended f or use as Primary P o wer in place of utility or in l[...]
-
Página 2
Generac ® Pow er Systems, Inc. I NTRODUCTION Thank you for purchasing this model of the Guardian product line by Generac P ower Systems Inc. This model is a compact, high performance, air - cooled, engine - driven generator designed to automatically supply electrical power to operate critical loads dur- ing a utility power failure. This unit is fa[...]
-
Página 3
T able of Cont ents Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Generac ® Pow er Systems, Inc. 1 Introduction ........................Inside F ront Cover Read This Manual Thoroughly ........................IFC Contents ..........................................................IFC Operation and Maintenance ............................IF[...]
-
Página 4
2 Generac ® Pow er Systems, Inc. Study these SAFETY RULES carefully before installing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , efficiently and reliably only if it is properly installed, operated and maintained. Many accidents are caused by failing to fo[...]
-
Página 5
Generac ® Pow er Systems, Inc. 3 ELE CTR ICAL HA Z AR DS • All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages to the transfer switch as does the standby generator when it is in opera- tion. A void contact with bare wires, t[...]
-
Página 6
Only qualified electricians or contractors should attempt such installations, which must comply strictly with applicable codes, standards and regulations. 1.1 U N P ACKING/I NSP ECTION After unpacking, carefully inspect the contents for damage. • This standby generator set has been factory sup- plied with a weather protective enclosure that is in[...]
-
Página 7
Section 1 — General Information Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Generac ® Pow er Systems, Inc. 5 1.4 Y OU R GEN ER A T OR Control P anel Battery Compartment Fuel Regulator Air Filter Exhaust Enclosure Oil Filter Data Decal Control Panel Air Filter Exhaust Enclosure Battery Compartment Fuel Regulator Oil Filter Oil Dipstic[...]
-
Página 8
6 Generac ® Pow er Systems, Inc. Section 1 — General Information Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1.5 SP E CI F ICA TIONS 1.5.1 GEN ERA T OR Model 04389-1 Model 04456-1 Model 04390-1 Rated Max. Continuous P ower Capacity (W atts*) 6,000 NG/7,000 LP 12,000 NG/12,000 LP 13,000 NG/15,000 LP† Rated V oltage 120/240 120/240 1[...]
-
Página 9
Generac ® Pow er Systems, Inc. 7 1 . 6 FUE L RE QUIRE MEN T S AN D R E C OM M EN D A TIONS W ith LP gas, use only the vapor withdrawal system. This type of system uses the vapors formed above the liquid fuel in the storage tank. The engine has been fitted with a fuel carburetion system that meets the specifications of the 1997 California Air Resou[...]
-
Página 10
3. Remove the small hose clamp and hose from the fuel regulator . It may be necessary to pry the hose off of the brass fitting using a screw driver to gen- tly lift up the hose edge. 4. Remove the brass hose fitting screwed into the fuel regulator . 5. Locate and identify the brass idle jet. This will be located in the fuel regulator casting facing[...]
-
Página 11
Generac ® Pow er Systems, Inc. 9 1.1 0 B A TTER Y INST ALLA TION Fill the battery with the proper electrolyte fluid if nec- essary and have the battery fully charged before installing it. Before installing and connecting the battery , complete the following steps: 1. Set the generator's Auto/Off/Manual switch to OFF . 2. T urn off utility pow[...]
-
Página 12
10 Generac ® Pow er Systems, Inc. • Where electr olyte contacts the eyes, flush thoroughly and immediately with water and seek medical attention; and • Spilled electrolyte is to be washed down with an acid neutralizing agent. A common practice is to use a solution of 1 pound (500 grams) bicarbonate of soda to 1 gallon (4 liters) of water . The[...]
-
Página 13
Generac ® Pow er Systems, Inc. 11 10. Connect an accurate A C voltmeter and a frequen- cy meter across transfer switch terminal lugs E1 and E2. V oltage should be 242-252 volts; fre- quency should read about 61-63 Hertz. 11. Connect the A C voltmeter test leads across termi- nal lug E1 and neutral; then across E2 and neu- tral. In both cases, volt[...]
-
Página 14
12 Generac ® Pow er Systems, Inc. 2.6 ADJ US TI NG TH E R E GU L A T OR (NA TUR AL GAS ONL Y) Although the generator has been factory set to pro- vide maximum power , it may be necessary in some areas to adjust this setting . Because natural gas has different BTU or power content across the country the engine may not perform as designed. If experi[...]
-
Página 15
Generac ® Pow er Systems, Inc. 13 Section 2 — Post Installation Start-up and Adjustments Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 5. T urn the speed adjust nut to obtain a frequency reading of 63 Hz. 6. When frequency is correct at no load, check the AC voltage reading . If voltage is incorrect, the volt- age regulator may require[...]
-
Página 16
14 Generac ® Pow er Systems, Inc. Section 3 — Operation Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 3.1 B R EAK-I N P ROCEDU R E Once the unit has been installed and all electrical checks have been made, it is strongly recommended that the following “Break -in Procedure” be completed to ensure correct generator operation in the f[...]
-
Página 17
Generac ® Pow er Systems, Inc. 15 3.4 SE QU ENCE OF AUT OMA TIC OP ER A TION The generator’s control panel houses a control logic circuit board. This board constantly monitors utility power source voltage. Should that voltage drop below a preset level, circuit board action will signal the engine to crank and start. After the engine starts, the c[...]
-
Página 18
16 Generac ® Pow er Systems, Inc. 3.5.2 TR ANSFER BA CK T O UTI LITY POWER SOURCE When utility power has been restored, transfer back to that source and shut down the generator . This can be accomplished as follows: 1. Set the generator’s main circuit breaker to its OFF (or open) position. 2. Let the engine run for a minute or two at no -load to[...]
-
Página 19
Generac ® Pow er Systems, Inc. 17 NOTE: If the fault is not repaired, the overcrank feature will continue to activate. 3.7 .3.1 Approximat e Crank Cycle T imes • 15 seconds ON • 7 seconds OFF • 7 seconds ON • 7 seconds OFF • Repeat for 45 seconds Approximately 90 seconds total 3.7 .4 OVERSPEED This feature protects the generator from dam[...]
-
Página 20
18 Generac ® Pow er Systems, Inc. 4.3 CHANGI NG TH E ENGI N E OI L 4.3.1 ENGI NE OI L R EC OMM EN D A TIONS Use oil of American P etroleum Institute (API) Service Class SG, SH or SJ . Use all season SAE 5W -30 Synthetic oil. Organic break -in oil is required before using synthetic oil. NOTE: The unit is supplied with “break-in ” oil. See the ?[...]
-
Página 21
Generac ® Pow er Systems, Inc. 19 Figure 4.7 — 12 kW and 15 kW Engine Air Cleaner 4.6 SP AR K P L UG(S) Reset the spark plug(s) gap or replace the spark plug(s) as necessary . See Section 4.13 for mainte- nance requirements. 1. Clean the area around the base of the spark plug(s) to keep dirt and debris out of the engine. Clean by scraping or was[...]
-
Página 22
20 Generac ® Pow er Systems, Inc. Lead-acid batteries present a risk of fir e because they generate hydrogen gas. The following procedur es are to be followed: • DO NOT SMOKE when near the battery; • DO NOT cause flame or spark in battery area; and • Discharge static electricity from your body befor e touching the battery by first touching a[...]
-
Página 23
Generac ® Pow er Systems, Inc. 21 The exhaust from this pr oduct gets extremely hot and remains hot after shutdown. High grass, weeds, brush, leaves, etc. must remain clear of the exhaust. Such materials may ignite and burn from the heat of the exhaust system. The maximum ambient temperature for the generator is 40° C (104° F). 4.1 0 A TTENTION [...]
-
Página 24
22 Generac ® Pow er Systems, Inc. Section 4 — Maintenance Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 4.1 3 SERVICE S CH EDU LE A TTENTION: It is recommended that all service work be performed by your nearest Generac/Guar dian Authorized Dealer . SYSTEM/COMPONENT PROCEDURE FREQUENCY X = Action Inspect Change Clean W = W eekly R = Rep[...]
-
Página 25
Generac ® Pow er Systems, Inc. 23 Section 5 — T roubleshooting Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 5.1 TROU B LE SHOO TI NG GUI DE P ROB LEM CAUSE C OR R E CTION The engine will not crank. 1. F use blown. 1. Replace 15A fuse in generator control panel. 2. Loose, corroded or defective 2. Tighten, clean or replace battery cable[...]
-
Página 26
24 Generac ® Pow er Systems, Inc. Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 1 2 & 15 kW – Drawing No. 0D85 00-B TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA ( DUAL SEC. ) 0 CUS T O MER SU PPLIE D BLA CK BATTERY 12V L OP HT O 0 S P 2 S P 1 IM2 86 85 IM1 D D DIA G RAM KE Y D S [...]
-
Página 27
Generac ® Pow er Systems, Inc. 25 Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 1 2 & 15 kW – Drawing No. 0D85 00-B C L OS E S T T O BEARIN G G R D 0 4 S TAT OR 1 94 224 224 22 5 1 5 224 17 4 22 5 224B 22 5 0 0 OU TP U T T O TRAN S FE R 22 22 MAN U A L F2 0 1 5A 66A 2 39 1 3 1 5 1 3 [...]
-
Página 28
26 Generac ® Pow er Systems, Inc. Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 1 2 & 1 5 kW – Drawing No. 0D85 0 1 -B IM1 - IGNITION MODULE , CYLINDER # 1 IM2 - IGNITION MODULE , CYLINDER # 2 L O P - L O W O IL PRE SSU RE S WIT CH SP1 , SP2 - SPARK PLUG S S W1 - A U T O / O FF[...]
-
Página 29
Generac ® Pow er Systems, Inc. 27 Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 1 2 & 1 5 kW – Drawing No. 0D85 0 1 -B 2 39 IM2 1 5 1 8 S P 2 24 0V IM1 0 1 94 17 1 5 2 3 1 5 2 39 S W 1 1 94 1 5A 22 11 2 3 11 22 11 S P 1 44 WINDIN G 12 0V 12 0V 33 NEUTRAL N2 N1 2 3 CUS T O ME R [...]
-
Página 30
28 Generac ® Pow er Systems, Inc. Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 7 kW – Drawing No. 0D90 13-C TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA ( DUAL SEC. ) CB2 - CIRCUIT BREAKER , ALTERNATOR EXCITATIO N BLA CK CUS T O MER SU PPLIE D BATTERY 12V L OP HT O SP 86 85 IM D D S[...]
-
Página 31
Generac ® Pow er Systems, Inc. 29 Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 7 kW – Drawing No. 0D90 13-C 0 4 C L OS E S T T O BEARI N G R D S TAT OR OU TP U T T O TRAN S FE R 24 0 V G ENERAT OR S WIT C H CO NTA C T OR 8 2 0 66A 1 94 1 5 0 66A 1 5A 2 39 2 3 1 5 1 5A F2 1 3A 1 3 0 1 3 [...]
-
Página 32
30 Generac ® Pow er Systems, Inc. Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 7 kW – Drawing No. 0D90 1 4-B IM - I G NITI O N M O D U L E L O P - L O W O IL PRE SSU RE S WIT CH S P - S PARK PL UG S W1 - A U T O / O FF / MAN U AL S WIT CH S W2 - S ET EXER C I S E S WIT CH S M - S [...]
-
Página 33
Generac ® Pow er Systems, Inc. 31 Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 7 kW – Drawing No. 0D90 1 4-B 224A 2 39 1 5A 0 1 5 1 8 IM 0 1 94 1 3 17 17 1 5 2 3 1 5 2 39 S W 1 1 5A 11 22 SP 0 17 0 SC F S 56 14 BATTERY CUS T O ME R SU PPLIE D SM 12 V SC N2 N1 1 3 TX 56 V A 1VA C 2[...]
-
Página 34
32 Generac ® Pow er Systems, Inc. 68 1 35 PRE PA C KA G ED U NIT S O NL Y 52 4 9 1 8 2 0 2 4 9 4 3 46 4 3 37 2 5 33 35 34 2 6 4 7 9 77 74 35 4 9 82 80 8 51 46 80 7 2 87 86 5 76 4 8 39 92 94 91 63 2 1 1 5 51 71 69 42 1 0 35 11 4 9 51 31 9 4 9 50 72 44 7 3 52 41 5 57 27 91 56 1 44 60 19 4 0 1 2 71 6 22 65 68 6 16 69 14 54 88 55 7 5 4 9 30 17 3 93 25[...]
-
Página 35
Generac ® Pow er Systems, Inc. 33 ITEM P ART NO .QTY . DESCRIPTION 1 0C6140 1 ASSEMBL Y , ENCLOSURE BASE (12KW/15KW) 0D1901 1 ASSEMBL Y , ENCLOSURE BASE (7KW) 2 0C6735 2 SUPPOR T , ROOF FOLDING 3 0C7061 1 ENCLOSURE, FRONT 4 0C7062 1 ENCLOSURE, EXHA UST SIDE (12KW / 15KW) 0C7062A 1 ENCLOSURE, EXHA UST SIDE (7KW) 5 0C7063 1 ENCLOSURE, SIDE & BA [...]
-
Página 36
34 Generac ® Pow er Systems, Inc. 46 22 37 7 38 83 2 8, 9 27 44 47 0 13 19 14 15 35 15 17 49 14 15 5 3 4 16 23 36 39 38 45 48 2 28 29 17 16 4 6 7 23 27 42 12 45 44 20 40 11 1 43 35 14 30 3 41 24 45 47 3 1 47 45 31 3 13 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Control Panel – Drawing No[...]
-
Página 37
Generac ® Pow er Systems, Inc. 35 ITEM P ART NO . QTY . DESCRIPTION 1 0A9947E 1 CIRCUIT BREAKER 30 X 2 240V SQD QOU230 (7KW) 0A9947G 1 CIRCUIT BREAKER 40 X 2 240V SQD QOU240 (8.5KW) 0A9947F 1 CIRCUIT BREAKER 50 X 2 240V SQD QOU250 (12KW) 0A9947C 1 CIRCUIT BREAKER 60 X 2 240V SQD QOU260 (13KW) 0A9947D 1 CIRCUIT BREAKER 70 X 2 240V SQD QOU260 (15KW)[...]
-
Página 38
36 Generac ® Pow er Systems, Inc. 30 1 2 9 16 27 9 22 22 21 1 6 2 3 24 1 0 31 7 9 17 1 8 11 5 3 2 39 4 0 36 1 9 2 5 1 5 2 6 38 33 32 34 34 35 12 37 14 8 1 3 3B 3A Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 7 kW GT S Load Center Assembly – Drawing No. 0D3 99 7 -E[...]
-
Página 39
Generac ® Pow er Systems, Inc. 37 ITEM P AR T NO . QTY . DESCRIPTION 1 0D4801 1 BO X GTS LOAD CENTER 2 0D4800 1 CO VER, 8 POSITION GTS LO AD CENTER 3 0C2237 1 TRANSFER SWITCH HOME ST ANDBY 100A2P250V 3A 077220 1 COIL UTILITY 3B 077220A 1 COIL ST ANDBY 3C 082574 1 INSULA T OR-SIDEW ALL (NO T SHO WN) 3D 084464 1 LIMIT SWITCH OPERA TION (NO T SHOWN) [...]
-
Página 40
38 Generac ® Pow er Systems, Inc. 30 1 16 27 9 22 22 21 16 2 3 24 1 0 31 7 9 17 1 8 6 11 5 3 2 39 4 0 36 1 9 2 5 1 5 2 6 38 41 33 32 34 34 35 42 37 12 14 8 1 3 3 B 3A Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1 2 kW and 1 5 kW G TS Load Cent er Assembly – Drawing No. 0D3996-D[...]
-
Página 41
Generac ® Pow er Systems, Inc. 39 ITEM P AR T NO . QTY . DESCRIPTION 1 0D3086 1 BO X GTS LOAD CENTER 2 0D3092 1 CO VER, 12 POSITION GTS LO AD CENTER 3 0C2237 1 TRANSFER SWITCH HOME ST ANDBY 100A2P250V 3A 077220 1 COIL UTILITY 3B 077220A 1 COIL ST ANDBY 3C 082574 1 INSULA T OR-SIDEW ALL (NO T SHO WN) 3D 084464 1 LIMIT SWITCH OPERA TION (NO T SHOWN)[...]
-
Página 42
40 Generac ® Pow er Systems, Inc. 17 15 18 2 2 14 13 12 9 7 8 31 24 3 27 28 3 2 19 23 6 5 65 6 4 63 6 2 6 1 60 59 58 5 2 5 1 50 49 48 47 46 45 44 43 5 7 1 42 38 3 7 36 35 3 4 33 3 40 2 3 26 10 4 3 4 25 11 30 20 66 2, 5 , 19 , 20 , 39 , 40 , 47 , 64 , 93 , 140 8, 11 , 12 , 13 6 7 4, 5 , 6 68 1 6A , 16B , 17 , 18 69 7, 47 , 48 , 49 , 50 , 51 , 52 , [...]
-
Página 43
Generac ® Pow er Systems, Inc. 41 ITEM P ART NO . QTY . DESCRIPTION 1 0C5729 1 ASSEMBL Y , CRANKCASE HOUSING WITH SLEEVE 2 0C3008 1 SEAL, 38 I.D . CRANKSHAFT 3 090388 8 SCREW , T APTITE M6-1.0 X 12 YC 4 0C5372 1 ASSEMBL Y , BREA THER 5 0C3005 1 GASKET , BREA THER CO VER 6 0E1684 3 SEP ARA TOR, OIL BREA THER 7 0D8067A 1 ASSEMBL Y , HEAD #1 G&S [...]
-
Página 44
42 Generac ® Pow er Systems, Inc. 112 112 111 1 07 1 06 1 05 1 04 1 03 1 02 1 09 99 92 95 96 91 89 90 89 88 86 85 83 84 82 81 1 30 99 11 8 12 6 94 7 9 7 8 7 6 77 7 5 74 122 12 5 12 3 12 5 11 9 12 0 1 37 1 36 1 34 1 33 1 32 127 2 9 1 35 11 3 1 01 11 0 121 112 12 8 124 24 80 87 98 97 1 38 1 39 1 1 116 141 Section 7 — Exploded Views and P arts List[...]
-
Página 45
Generac ® Pow er Systems, Inc. 43 ITEM P ART NO . QTY . DESCRIPTION 74 0C5136A 2 KNOB, AIR CLEANER 75 0C3024 1 CO VER, AIRBO X NG/LP 76 0C3040 1 PRE-CLEANER, 77 0C8127 1 ELEMENT , AIR CLEANER 78 0D8564A 1 ASSEMBL Y , MIXER/AIRBO X 990 0D8564B 1 ASSEMBL Y , MIXER/AIRBO X 760 79 0D2595 4 SCREW SHOULDER (8MM) M6-1.0 X 18 80 0D4417 4 W ASHER,R UBBER 1[...]
-
Página 46
44 Generac ® Pow er Systems, Inc. 3 7 6 51 7 8 21 53 9 3 2 1 4 5 23 11 3 1 3 1 12 5 22 14 20 38 15 3 0 24 26 32 10 19 16 28 27 17 10 1 28 3 1 3 2 17 3 2 3 1 33 28 13 39 18 4 0 28 3 4 35 3 4 44 48 30 45 46 3 4 36 47 5 2 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 7 kW Generator – Drawing N[...]
-
Página 47
Generac ® Pow er Systems, Inc. 45 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 7 kW Generator – Drawing No. 0D35 04-C ITEM P AR T NO . QTY . DESCRIPTION 1 0C6934 1 AD APT OR, ENGINE 2 0C9935H 1 ST A TOR 3 0C9934H 1 RO TOR 4 0C6043A 1 CARRIER, REAR BEARING 5 0C8096 1 F AN, 8" CUR VED B[...]
-
Página 48
46 Generac ® Pow er Systems, Inc. 29 3 4 11 2 5 24 43 21 7 13 33 12 38 17 3 2 3 1 28 3 1 20 19 10 17 15 3 2 16 22 39 8 6 37 14 3 2 40 32 24 25 10 30 19 26 28 27 28 3 2 3 1 41 10 18 36 35 29 41 42 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1 2 kW and 1 5 kW Generator – Drawing No. 0D3 4 1[...]
-
Página 49
Generac ® Pow er Systems, Inc. 47 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1 2 kW and 1 5 kW Generator – Drawing No. 0D3 4 1 7-D ITEM P AR T NO . QTY . DESCRIPTION 1 0C6934 1 AD APT OR, ENGINE 2 0C7930 1 ST A TOR 12KW 0D2359 ST A T OR 15KW 3 0C7944 1 RO TOR 12KW 0D2356 R O T OR 15KW 4 [...]
-
Página 50
48 Generac ® Pow er Systems, Inc. 11 47 33 3 4 36 35 37 27 45 43 39 18 19 20 23 3 2 44 48 24 46 11 22 29 28 3 1 30 17 5 2 1 14 13 26 38 25 25 40 41 21 15 16 6 1 2 4 42 10 5 7 3 8 9 49 5 1 50 5 4 53 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GN4 1 0 Engine – Drawing No. 0D35 39-D P art 1[...]
-
Página 51
Generac ® Pow er Systems, Inc. 49 ITEM P AR T NO . QTY . DESCRIPTION 1 071978 1 ASSEMBL Y , CONNECTING ROD 2 071980 1 PIN, PIST ON D20 3 021533 1 SET , PIST ON RING 90MM 4 0C5848 1 PIST ON, HC 5 071983 2 RET AINER, PIST ON PIN 20 6 0D4287 1 ASSEMBL Y , CRANKSHAFT GH410 SMALL T APER 7 0A7628 1 ARM, GO VERNOR RC45 8 078658 1 PIN, "R" GO VE[...]
-
Página 52
50 Generac ® Pow er Systems, Inc. 19 21 6 2 20 28 24 3 40 40 41 44 2 4 6 6 5 12 7 8 9 10 13 14 1 16 18 11 6 37 36 35 27 17 18 3 4 33 3 4 18 29 30 3 1 38 6 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GN4 1 0 Engine – Drawing No. 0D35 39-D P art 2[...]
-
Página 53
Generac ® Pow er Systems, Inc. 51 ITEM P AR T NO . QTY . DESCRIPTION 1 0C1069 5 SCREW , T APTITE M6-1.0X8 YELLO W CHROME 2 0D2922 1 HOUSING, BLO WER 3 0C8435 1 TUBE, DIPSTICK 4 0C9997 1 GU ARD , F AN 5 088434 1 WRAPPER, BO TT OM 6 045756 11 SCREW , T APTITE M6-1X10 YELLO W CHROME 7 088433B 1 WRAPPER, T OP 8 0D9004A 1 ASSY , ST AR TER 9 059985 2 SC[...]
-
Página 54
ITEM P ART NO . QTY . DESCRIPTION 1 0D5694 1 CASTING, TWIN REGULA T OR HOUSING 2 0C5765 1 SOLENOID , TWIN REGULA T OR 3 0C4647 1 GASKET , SOLENOID 4 0C4680 1 PLUNGER, LP REGULA T OR ASSEMBL Y 5 0C6070 1 SPRING-SOLENOID , PLUNGER 6 022985 4 W ASHER, FLA T #6 7 022264 4 W ASHER, LOCK M4 8 075475 4 SCREW PPHM M4-0.7 X 10 9 0C5760A 1 JET , GN 410 ENGIN[...]
-
Página 55
Generac ® Pow er Systems, Inc. 53 Section 8 — Mounting Dimensions Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Drawing No. 0D3 7 3 9-B T M6PEM-T M6P M6PEM PE REAR VIEW L EFT S IDE VIEW TRANSFER SWITCH R I G HT S IDE VIEW F R O NT VIEW AIR NTAKE ( IF SUPPLIED ) " D O N O T LIFT BY THE R OO F" L IFTIN G H O LE S 4- CO RNER S ?[...]
-
Página 56
54 Generac ® Pow er Systems, Inc. Section 9 — Notes Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators[...]
-
Página 57
Generac ® Pow er Systems, Inc. 55 Section 9 — Notes Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators[...]
-
Página 58
56 Generac ® Pow er Systems, Inc. CALI FOR N IA EM ISSION C ONTROL W AR R ANT Y S T A TEM ENT Y OUR W AR RANT Y R IGHTS AND OB LIGA TIONS The California Air Resources Board (CARB) and Generac P ower Systems, Inc. (Generac) are pleased to explain the Emission Control System W arranty on your new engine. * In California, new utility , and lawn and g[...]
-
Página 59
Generac ® Pow er Systems, Inc. 57 EM IS SION CONTROL S Y S TEM W AR R ANT Y Emission Control System W arranty (ECS W arranty) for 1995 and later model year engines: (a) Applicability: This warranty shall apply to 1995 and later model year engines. The ECS W arranty Period shall begin on the date the new engine or equipment is purchased by/delivere[...]
-
Página 60
Part No. 0D8846 Re vision H (08/07/03) Printed in U.S.A. Section 1 0 – W arranty Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GEN ERAC PO WER SY STEMS S T AN D AR D "T WO YEAR" LIM ITED W ARR ANT Y FOR GU AR DIAN “EM ERGENCY AUT OMA TIC S T AN DBY GENER A T ORS” F or a period of two years from the date of original sale, G[...]