Guardian Technologies 004582-2 manual
- Consulta online o descarga el manual de instrucciones
- 36 páginas
- 2.75 mb
Ir a la página of
manuales de instrucciones parecidos
-
Portable Generator
Guardian Technologies 5631
1 páginas 0.78 mb -
Portable Generator
Guardian Technologies 5617
1 páginas 0.85 mb -
Portable Generator
Guardian Technologies 5657
1 páginas 0.65 mb -
Portable Generator
Guardian Technologies 04164-3
56 páginas 2.97 mb -
Portable Generator
Guardian Technologies 004708-0
52 páginas 1.73 mb -
Portable Generator
Guardian Technologies 05649
4 páginas 0.56 mb -
Portable Generator
Guardian Technologies 005243
72 páginas 7.34 mb -
Portable Generator
Guardian Technologies 5308
90 páginas 14.83 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Guardian Technologies 004582-2. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Guardian Technologies 004582-2 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Guardian Technologies 004582-2 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Guardian Technologies 004582-2, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Guardian Technologies 004582-2 debe contener:
- información acerca de las especificaciones técnicas del dispositivo Guardian Technologies 004582-2
- nombre de fabricante y año de fabricación del dispositivo Guardian Technologies 004582-2
- condiciones de uso, configuración y mantenimiento del dispositivo Guardian Technologies 004582-2
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Guardian Technologies 004582-2 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Guardian Technologies 004582-2 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Guardian Technologies en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Guardian Technologies 004582-2, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Guardian Technologies 004582-2, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Guardian Technologies 004582-2. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
Owner’ s Man ual • SAFETY • ASSEMBL Y • OPERA TION • TR OUBLESHOO TING • ELECTRICAL D A T A • P AR TS • W ARRANTY 1-800-333-1322 UL TRA SOURCE P or table Generator COMMERCIAL • INDUSTRIAL • RESIDENTIAL MODEL: 004582-2 15,000 W att P or table Generator A UTHORIZED DEALER SUPPORT :[...]
-
Página 2
T able of Contents Commercial-Industrial-Residential P or table Generator System Safety Rules .................................................................. 1 Section 1 – General Information ................................. 4 1.1 Unpacking ............................................................................. 4 1.1.1 Accessory Box ...[...]
-
Página 3
INTRODUCTION Thank you f or purchasing this model by Generac P ower Systems , Inc. This model is a compact, high performance, air-cooled, engine driven generator designed to supply electrical power to operate electrical loads where no utility power is a vailab le or in place of utility due to a power outage . READ THIS MANU AL THOROUGHL Y If any po[...]
-
Página 4
2 Nev er star t or stop the unit with electrical loads connected to receptacles AND with connected devices turned ON. Star t the engine and let it stabilize bef ore connecting electrical loads. Disconnect all electrical loads before shutting down the generator . Do not inser t objects through unit's cooling slots. Never operate generator: indo[...]
-
Página 5
ELECTRICAL HAZARDS All generators cov ered by this manual produce dangerous electrical voltages and can cause f atal electr ical shoc k. Utility power delivers extremely high and dangerous v oltages as does the generator when it is in operation. Av oid contact with bare wires, ter minals , connections, etc., while the unit is running. Ensur[...]
-
Página 6
1.1 UNP A CKING Set the palleted car ton on a rigid flat surface . Remov e staples along bottom of car ton that f asten car ton to pallet. Open car ton from top . Remov e all packaging material. Remov e separate accessory box. Lift car ton off the generator . Remov e generator from shipping pallet by remo ving bolts through the shipping brack ets ([...]
-
Página 7
5 1.2.3 B A TTER Y CONNECTION The battery shipped with the generator has been provided fully charged. Caution must be taken when connecting the battery . NO TE: A battery may lose some of it’ s charge when not in use for prolonged periods of time. Cut the tie wrap cable holding the RED and BLA CK batter y cables to the stator . Connect the RED ba[...]
-
Página 8
6 Section 2 – Operation Commercial-Industrial-Residential P or table Generator System 2.1 KNO W THE GENERA T OR Read the Owner’ s Manual and Safety Rules before operating this generator . Compare the generator to Figures 4 through 6 to become f amiliarized with the locations of various controls and adjustments. Save this manual f or future refe[...]
-
Página 9
2.2 CORD SETS AND CONNECTION PLUGS 2.2.1 120 V A C, 20 AMP , DUPLEX RECEPT A CLE This is a 120 V olt outlet protected against overload by a 20 Amp push-to-reset circuit breaker (Figure 7). Use each sock et to power 120 V olt AC , single phase, 60 Hz electrical loads requiring up to a combined 2400 watts (2.4 kW) or 20 Amps of current. Use only high[...]
-
Página 10
Use this receptacle to operate 120 V olt AC , 60 Hz, single phase loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps . The outlet is protected by a 30 Amp push-to-reset circuit break er . 2.2.4 120/240 V A C, 30 AMP RECEPT A CLE Use a NEMA L14-30 plug with this receptacle. Connect a suitable 4- wire grounded cord set to the plug and to t[...]
-
Página 11
Proper gr ounding of the generator will help prevent electrical shock in the e vent of a ground f ault condition in the generator or in connected electrical devices. Proper grounding also helps dissipate static electricity , which often builds up in ungrounded de vices. 2.3.2 CONNECTING ELECTRICAL LO ADS DO NO T connect 240 V olt loads to 120 V olt[...]
-
Página 12
2.6 BEFORE ST AR TING THE GENERA T OR Prior to operating the generator , engine oil and gasoline will need to be added, as follo ws: 2.6.1 ADDING ENGINE OIL NO TE: When adding oil to the engine crankcase in the future, use only high quality detergent oil rated with API service classification SG, SH or SL SAE 30 weight. Use no special additives. 5W-[...]
-
Página 13
2.7 T O ST ART THE ENGINE Never start or stop engine with electrical devices plug ged into the receptacles AND devices turned on. Unplug all electrical loads from the unit's receptacles before star ting the engine. Make sure the unit is in a le vel position. Open the fuel shut-off valv e (Figure 15). Figure 15 - Fuel Shut-off V alve Locate[...]
-
Página 14
2.9 A UT OMA TIC IDLE CONTR OL This feature is designed to g reatly improv e fuel economy . When this switch is turned “ On , ” the engine will only run at its normal fast gov er ned engine speed when electrical load is connected. When the load is remov ed, the engine will run at a reduced speed of 2100 RPM. With the s witch “ Off , ” the e[...]
-
Página 15
13 Section 3 — Maintenance Commercial-Industrial-Residential P or table Generator System 3.2.1 GENERA T OR SPECIFICA TIONS MODEL GPS 15,000 Model # 004582-2 Rated Max. Po wer 15.0 kW Surge Po wer 22.5 kW Rated AC V oltage 120/240 Rated Max A C Load Current @ 240V 62.5 Amps Current @ 120V 125.0 Amps Rated F requency 60 Hz @ 3600 RPM Phase Single P[...]
-
Página 16
14 Section 3 — Maintenance Commercial-Industrial-Residential P or table Generator System 3.3 GENERAL RECOMMEND A TIONS The warranty of the gener ator does not cover items that ha ve been subjected to operator abuse or negligence . T o receive full v alue from the warranty , the operator must maintain the gener ator as instructed in this manual. S[...]
-
Página 17
15 Section 3 — Maintenance Commercial-Industrial-Residential P or table Generator System 3.3.6 REPLA CING THE SP ARK PLUG Use Champion RC14YC spark plug or equivalent. The correct air gap is 1.01 mm (0.040 in.) (Figure 18). Replace the plug once each year . This will help the engine star t easier and run better . 1. Stop the engine and pull the s[...]
-
Página 18
3.6 ADJUSTING V AL VE CLEARANCE After the first 50 hours of operation, check the v alve clearance in the engine and adjust if necessary . Important: If feeling uncomf or table about doing this procedure or the proper tools are not av ailable, please tak e the generator to the nearest service center to have the v alve clearance adjusted. This is a v[...]
-
Página 19
Section 3 — Maintenance Commercial-Industrial-Residential P or table Generator System 17 3.8 LONG TERM ST ORA GE It is impor tant to pre vent gum deposits from f or ming in essential fuel system par ts such as the carb uretor , fuel hose or tank during storage. Also , experience indicates that alcohol-blended fuels (called gasohol, ethanol or met[...]
-
Página 20
Section 4 — T roubleshooting Commercial-Industrial-Residential P or table Generator System 4.1 TROUBLESHOO TING GUIDE PROBLEM CA USE CORRECTION Engine is running, but no A C output is av ailable. 1. Circuit breaker is open. 2. Poor connection or def ective cord set. 3. Connected device is bad. 4. Fault in gener ator . 1. Reset circuit breaker . 2[...]
-
Página 21
19 19 Section 5 — Electrical Data Electrical Schematic – Drawing No. 0G0733[...]
-
Página 22
20 Section 5 — Electrical Data Wiring Diagram – Drawing No. 0G0731[...]
-
Página 23
21 Section 5 — Electrical Data Wiring Diagram – Drawing No. 0G0731[...]
-
Página 24
22 Section 6 — Exploded Views and Parts Lists Handle, Frame & Wheel Kit – Drawing No. 0E0695-B[...]
-
Página 25
23 Section 6 — Exploded Views and Parts Lists Handle, Frame & Wheel Kit – Drawing No. 0E0695-B ITEM P AR T NO . QTY . DESCRIPTION 1 057058 4 SCREW HHC M6-1.0 X 55 2 0D5315 4 R UBBER T ANK MOUNT 3 0D4570 1 CAP , FUEL WITH GAUGE & VENT 4 0D22850SR V 1 KIT , FUEL T ANK 5 045771 4 NUT HEX M8-1.25 6 022129 10 W ASHER LOCK M8-5/16 7 022145 14[...]
-
Página 26
24 Section 6 — Exploded Views and Parts Lists Control P anel – Drawing No. 0G0727-B[...]
-
Página 27
25 Section 6 — Exploded Views and Parts Lists Control P anel – Drawing No. 0G0727-B ITEM P AR T NO . QTY . DESCRIPTION 1 087968 1 SWITCH, ROCKER -/0 2 090418 1 OUTLET , 12VDC SNAP 3 0D6640 1 CO VER, GOVERNOR CONTR OL 4 090987 6 SCREW PPHM M3-0.5 X 12 5 0D8740 1 P ANEL, SHEET MET AL (15 KW) 0G0309 1 P ANEL, SHEET MET AL (17.5 KW) 6 068868 2 OUTL[...]
-
Página 28
26 Section 6 — Exploded Views and Parts Lists Generator – Drawing No. 0G0742-A[...]
-
Página 29
27 Section 6 — Exploded Views and Parts Lists Generator – Drawing No. 0G0742-A ITEM P AR T NO . QTY . DESCRIPTION 1 0C6934 1 AD APTOR, ENGINE 2 0G1177 1 ST A T OR 15KW 0D2136 ST A TOR 17.5KW 3 0G11760SRV 1 ASSEMBL Y , ROT OR WITH F AN 15KW 0D21350SR V ASSEMBL Y , ROT OR WITH F AN 17.5KW 4 0C6043B 1 CARRIER, REAR BEARING 5 0D2492 1 EXHA UST MANI[...]
-
Página 30
28 Section 6 — Exploded Views and Parts Lists GT -760/990 Engine – Drawing No. 0E8589-W - Part 1[...]
-
Página 31
27 29 Section 6 — Exploded Views and Parts Lists GT -760/990 Engine – Drawing No. 0E8589-W - Part 1 ITEM P AR T NO . QTY . DESCRIPTION 1 0C5729 1 ASSEMBL Y , CRANKCASE HOUSING WITH SLEEVE 2 0E9843 1 SEAL, 38 I.D . CRANKSHAFT 3 090388 3 SCREW , T APTITE M6-1.0 X 12 BP 4 0C5372 1 ASSEMBL Y , BREA THER 5 0C3005 1 GASKET , BREA THER CO VER 6 0E3372[...]
-
Página 32
30 Section 6 — Exploded Views and Parts Lists GT -760/990 Engine – Drawing No. 0E8589-W - Part 2[...]
-
Página 33
31 Section 6 — Exploded Views and Parts Lists GT -760/990 Engine – Drawing No. 0E8589-W - Part 2 ITEM P AR T NO . QTY . DESCRIPTION 66 0D6592 1 WINGNUT , AIRBOX 67 0D4511 1 PRECLEANER, AIR 68 0D9723 1 ELEMENT , AIR CLEANER 69 0E5302 1 STUD M6-1.0 X 73 70 0D4183 1 AD APTOR, SPIT BA CK 71 0D6327 1 GASKET , SPITBACK 72 0D2774B 1 BASE, AIRBOX 73 0D[...]
-
Página 34
32 CALIFORNIA EMISSION CONTROL W ARRANTY ST A TEMENT Y OUR W ARRANTY RIGHTS AND OBLIGA TIONS The Calif or nia Air Resources Board (CARB) and Generac P ower Systems, Inc. (Generac) are pleased to e xplain the Emission Control System warr anty on your ne w engine. In California, new off-road Large Spark-Ignition (LSI) engines must be designed, b uilt[...]
-
Página 35
33 EMISSION CONTROL SYSTEM W ARRANTY Emission Control System W arranty (ECS warr anty) for 2001 and later model y ear LSI engines: (a) Applicability: This warranty shall apply to 2001 and later model y ear engines. The ECS W arranty period shall begin on the date the new engine or equipment is purchased by/deliv ered to its or iginal, end-use purch[...]
-
Página 36
Section 7 – Warranty Commercial-Industrial-Residential P or table Generator System P ar t No . 0G1086 Rev . C Printed in U.S .A. 03/27/07 GENERA C PO WER SYSTEMS “TWO YEAR” LIMITED W ARRANTY FOR GU ARDIAN ® “15,000 W A TT POR T ABLE GENERA T OR” For a period of two y ears from the date of original sale, Generac P ower Systems, Inc. (Gene[...]