HP (Hewlett-Packard) HP Smart Array E200 manual
- Consulta online o descarga el manual de instrucciones
- 39 páginas
- 0.96 mb
Ir a la página of
manuales de instrucciones parecidos
-
Network Card
HP (Hewlett-Packard) 5971-0821
120 páginas 0.99 mb -
Network Card
HP (Hewlett-Packard) HEWLETT-PACKARD
30 páginas 0.37 mb -
Network Card
HP (Hewlett-Packard) 3C590
34 páginas 0.08 mb -
Network Card
HP (Hewlett-Packard) A5799A
166 páginas 1.51 mb -
Network Card
HP (Hewlett-Packard) En3700
264 páginas 2.33 mb -
Network Card
HP (Hewlett-Packard) HP Smart Array 64MB
39 páginas 0.96 mb -
Network Card
HP (Hewlett-Packard) Console Management Controller
108 páginas 3.82 mb -
Network Card
HP (Hewlett-Packard) BL30p
48 páginas 0.75 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones HP (Hewlett-Packard) HP Smart Array E200. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica HP (Hewlett-Packard) HP Smart Array E200 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual HP (Hewlett-Packard) HP Smart Array E200 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales HP (Hewlett-Packard) HP Smart Array E200, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones HP (Hewlett-Packard) HP Smart Array E200 debe contener:
- información acerca de las especificaciones técnicas del dispositivo HP (Hewlett-Packard) HP Smart Array E200
- nombre de fabricante y año de fabricación del dispositivo HP (Hewlett-Packard) HP Smart Array E200
- condiciones de uso, configuración y mantenimiento del dispositivo HP (Hewlett-Packard) HP Smart Array E200
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de HP (Hewlett-Packard) HP Smart Array E200 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de HP (Hewlett-Packard) HP Smart Array E200 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico HP (Hewlett-Packard) en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de HP (Hewlett-Packard) HP Smart Array E200, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo HP (Hewlett-Packard) HP Smart Array E200, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual HP (Hewlett-Packard) HP Smart Array E200. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
Front View: Rear View: 1. Eight sockets for PC2-5300 Fully Buffered DIMMs (DDR2-667) 1. Torx service tool 2. Hot-plug fans, full redundancy 2. Optional pass through cable door 3. Systems Insight Display 3. Two Embedded NC373i Multifunction Gigabit Server Adapters with TCP/IP Offload Engine 4. Quick release lever for rapid server access 5. Support f[...]
-
Página 2
At A Glance The HP ProLiant DL380, the world's best selling server, delivers on its history of design excellence with enterprise-class uptime and manageability, proven 2-way Intel® Xeon® performance, and 2U density for a variety of rack deployments and applications. Processors: Quad-Core and Dual-Core Intel® Xeon® processors for blazing pe[...]
-
Página 3
NOTE: For a brief, printer friendly data sheet that describes this product and informs you of the essential capabilities and specifications, please visit: http://h71028.www7.hp.com/ERC/downloads/5983-0605EN.pdf . NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Fa[...]
-
Página 4
Memory Type PC2-5300 Fully Buffered DIMMs (DDR2-667) with 4:1 and 2:1 interleaving available (interleaving requires identical DIMMs) Standard (Entry Models) 1 GB (2 x 512 MB) Standard (Base Models) 2 GB (2 x 1 GB) Standard (Performance Models) 4 GB (4 x 1 GB) Maximum 32 GB (8 x 4 GB) NOTE: Memory DIMMs in systems with the Front Side Bus (FSB) runni[...]
-
Página 5
Storage Controller One of the following depending on Model Performance Models: HP Smart Array P400/512MB BBWC Controller (RAID 0/1/1+0/5/6) Base Models: HP Smart Array P400/256MB Controller (RAID 0/1/1+0/5) Available upgrades : 512MB battery-backed write cache (BBWC) or standalone battery for RAID 0/1/1+0/5/6 Entry Models: HP Smart Array E200/64MB [...]
-
Página 6
Interfaces Serial 1 Pointing Device (Mouse) 1 Graphics 1 Keyboard 1 VGA 2 (1 front, 1 back) Network RJ-45 2 iLO 2 remote management port 1 USB 2.0 Ports 5 total: 2 front, 2 back, 1 internal NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb- support.html . Gr[...]
-
Página 7
Server Management Stand Alone Software Product - ProLiant Essentials HP Systems Insight Manager HP Systems Insight Manager (HP SIM) provides a unified, secure and extensible standards-based environment to centrally manage servers, storage and other infrastructure devices, (both HP and non-HP) across multiple operating system platforms. ProLiant Ess[...]
-
Página 8
Core Infrastructure Management SmartStart SmartStart is a tool that simplifies server setup, providing a rapid way to deploy reliable and consistent server configurations. For more information, please visit the SmartStart Web site at: http://www.hp.com/servers/smartstart . SmartStart version supported (minimum): SmartStart 7.51 Insight Management A[...]
-
Página 9
System Fans Fully redundant hot plug fans ship standard (N+1). OS Support Microsoft Windows Server 2000 Microsoft Windows Server 2003 Microsoft Windows Small Business Server 2003, R2 Microsoft Windows Server 2008 Novell NetWare Red Hat Enterprise Linux SUSE Linux Enterprise Server SCO UnixWare, OpenServer VMware Virtualization Software Solaris 10 3[...]
-
Página 10
Telco Rack Support DL380 G5 Telco Rack Kit: Support for all 2-post Telco racks requires the use of the standard rack kit and an additional option kit from Rack Solutions: http://www.racksolutions.com/hp/ . Factory Express Portfolio for Servers and Storage HP Factory Express offers configuration, customization, integration and deployment services fo[...]
-
Página 11
NOTE: High Performance Computing (HPC) interconnect technologies are available for the DL380 under the Cluster Platform product portfolio. These high-speed interconnects are fully supported by HP when they are part of these configure to order clusters. Solutions can be defined with a lot of flexibility with the help of configuration tools. Please v[...]
-
Página 12
NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. HP DL380 G5 Performance Models Quad-Core Models HP DL380G5 X5460 4G 458561-xx1 HP DL380G5 X5450 4G 458562-xx1 HP DL380G5 E5345 4G 433524-xx1 Dual-Core Models HP DL380G5 5160 [...]
-
Página 13
Form Factor Rack (2U), Height 3.38-inch/8.59cm; Depth: 26 inches (66 cm) Availability Hot Plug Fully Redundant Fans Standard HP DL380 G5 Entry Models Quad-Core Models DL380G5 E5405 1G 458568-xx1 HP DL380G5 E5310 1G 433527-xx1 Dual-Core Models HP DL380G5 5120 1G 417454-xx1 HP DL380G5 5110 1G 417453-xx1 Processor(s) One of the following depending on [...]
-
Página 14
NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for information on CTO product offerings and requirements. NOTE: HP does not allow factory integration of options [...]
-
Página 15
Quad-Core Intel® Xeon® Processor X5355 (2.66 GHz , 120 Watts, 1333 FSB) DL380 G5 FIO Kit 437939-L21 Quad-Core Intel® Xeon® Processor E5345 (2.33 GHz, 80 Watts, 1333 FSB) DL380 G5 FIO Kit 437940-L21 Quad-Core Intel® Xeon® Processor E5335 (2.00 GHz, 80 Watts, 1333 FSB) DL380 G5 FIO Kit 437941-L21 Quad-Core Intel® Xeon® Processor E5320 (1.86 G[...]
-
Página 16
NOTE: Some options may not be integrated at the factory. Contact your local sales representative for additional information. HP ProLiant DL380 G5 Unique Options Mixed Riser Cage Option Kit (PCI-E/PCI-X) 410570-B21 HP Insight Control Management Suites NOTE: Electronic licensing options are available for Insight Control suites software products. Plea[...]
-
Página 17
Customer will receive a printed license entitlement certificate and documentation via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. HP Server Migration Pack - Universal Edition, [...]
-
Página 18
ProLiant Software Maintenance Subscription ProLiant Software Maintenance Single Release 356573-B21 NOTE: Please see the SmartStart QuickSpecs for additional information regarding the subscription purchase: http://h18000.www1.hp.com/products/quickspecs/division/11073.html (Worldwide) Processors Quad-Core Inte®l Xeon® Processor X5460 (3.16 GHz, 120[...]
-
Página 19
Hard Drives Hot Plug SFF SAS 2.5" Drives HP 146GB 3G SAS 10K SFF DP HDD 418367-B21 HP 146GB 3G SAS 10K SFF SP HDD 431958-B21 HP 72GB 3G SAS 15K SFF DP HDD 418371-B21 HP 72GB 3G SAS 15K SFF SP HDD 431935-B21 HP 72GB 3G SAS 10K SFF DP HDD 384842-B21 HP 72GB 3G SAS 10K SFF SP HDD 375861-B21 HP 36GB 3G SAS 15K SFF DP HDD 418369-B21 HP 36GB 3G SAS [...]
-
Página 20
http://h18000.www1.hp.com/products/quickspecs/12400_div/12400_div. html (Smart Array P400 Controller) http://h18000.www1.hp.com/products/quickspecs/12247_div/12247_div. html (Smart Array P600 Controller) http://h18000.www1.hp.com/products/quickspecs/12616_div/12616_div. html (Smart Array P800 Controller) SAS HBA HP SC44Ge Host Bus Adapter 416096-B2[...]
-
Página 21
HPC Specific Options HP IB 4X DDR PCI-e Dual Port HCA 409376-B21 HP IB 4X DDR PCI-e single PORT HCA 431039-B21 HP IB 4X SDR PCI-e single PORT HCA 431038-B21 HP IB 4X DDR Conn-X PCI-e Dual Port HCA 448397-B21 Redundant Options Redundant Power Supply 350/370/380 G5 AU Kit 399771-011 Redundant Power Supply 350/370/380 G5 EU Kit 399771-021 Redundant Po[...]
-
Página 22
(Worldwide) http://h18006.www1.hp.com/products/quickspecs/12128_div/12128_div.html (Worldwide) For an up-to-date listing of the latest O/S and software support details for HP Ultrium tape drives, please visit: http://www.hp.com/go/connect . Rack-Mount Tape Drive Enclosures HP StorageWorks 1U SCSI Rack-Mount kit NOTE: The 1U Rack-Mount Kit can suppo[...]
-
Página 23
Tape Autoloaders HP StorageWorks DAT Autoloader HP StorageWorks DAT 72x10 tape autoloader AE313B HP StorageWorks 1/8 Tape Autoloader HP StorageWorks 1/8 G2 LTO-4 Ultrium 1760 SAS Tape Autoloader AK377A HP StorageWorks 1/8 LTO-3 Ultrium 920 G2 Tape Autoloader AH165A HP StorageWorks 1/8 G2 LTO-3 Ultrium 920 SAS Autoloader AH558A HP StorageWorks 1/8 L[...]
-
Página 24
NOTE: Please reference the MSL2024, MSL4048, MSL8096 and MSL6000 Tape Library QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at: http://www.hp.com/go/ebs . Cluster Options ProLiant Cluster Starter Kit 364023-B22 NOTE: For additional informat[...]
-
Página 25
HP StorageWorks Modular Smart Array 30 HP StorageWorks Modular Smart Array 30 SB NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies 302969-B21 HP StorageWorks Modular Smart Array 30 DB NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies 302970-B21 NOTE: Please see the Modular Smart Array 30[...]
-
Página 26
Uninterruptible Power Systems - Rack HP R1.5 VA 1U UPS INTL AF418A HP R1.5 VA 1U UPS JPN AF421A HP R1.5 VA 1U UPS NA AF419A HP R/T2200 2-U ERM AF412A HP Monitored Power Distribution Unit (PDU) HP Monitored Power Distribution Unit: Full Rack Version 17.3 kVA Monitored PDU Model S2324 AF503A 8.6 kVA Monitored PDU Model S1324 AF504A 16.6 kVA Monitored[...]
-
Página 27
HP Rack 10000 Series (Graphite Metallic) HP S10614 (14U) Rack Cabinet - Shock Pallet 292302-B22 NOTE: xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment installed. Not all Compaq equipment is qualified to be s[...]
-
Página 28
HP KVM Switch Options 2x1x16 IP Console Switch with Virtual Media AF601A 4x1x16 IP Console Switch with Virtual Media AF602A 2x16 Server Console Switch with Virtual Media AF600A PS/2 Virtual Media Interface Adapter, 1 pack NOTE: Requires PS/2 and one USB port on server. AF604A Server Console Switch (KVM), 0 x 1 x 8 port 336044-B21 Server Console Swi[...]
-
Página 29
Onsite HW support 24x7, 4hr response and Red Hat ES Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic U8334E NOTE: For more information, customer/resellers can contact: http://www.hp.com/services/carepack DA - 12477 Worldwide QuickSpecs — Version 36 — 2/29/2008 Page 29[...]
-
Página 30
NOTE: Memory configurations listed do not apply to "Factory Integrated Models". Standard Memory 2 GB PC2-5300 Fully Buffered DIMMs (DDR2-667) (2 x 1 GB) Upgrading Memory and Memory Interleaving When upgrading memory, DIMMs 1A and 2A must match. DIMMs 3B and 4B, DIMMs 5C and 6C, and DIMMs 7D and 8D must match and must be installed as a pai[...]
-
Página 31
Online spare memory configuration Online spare FBDIMM configuration requirements (in addition to general configuration requirements): When only bank A is being used, it must be fully populated with dual-rank FBDIMMs. If banks A and C are being used, they must be fully populated. If installed, bank A and bank C must contain FBDIMMs with identical pa[...]
-
Página 32
1-8 Eight SFF SAS hot plug hard drive bays Drive Support Quantity Supported Position Supported Controller Removable Media 1.44-MB Diskette Drive Only 1 available removable media bay Slimline bay Integrated diskette NOTE: Optional Slimline CD-RW/DVD- ROM Combo Option Kit NOTE: Included in performance models. Only 1 available removable media bay Slim[...]
-
Página 33
External Storage Quantity Supported Position Supported Host Controller or Adapter Modular Smart Array 20 Family 1 per SCSI VHDCI connector External Smart Array 6402/128 Controller Smart Array 6404/256 Controller NOTE: Optional mixed PCI-X/E cage required. Modular Smart Array 30 Family Up to 4 External Smart Array E500/256MB Controller Up to 2 HP Sm[...]
-
Página 34
LTO-1 Ultrium 232 LTO-2 Ultrium 448 LTO-2 Ultrium 460 LTO-3 Ultrium 960 LTO-3 Ultrium 920 LTO-4 Ultrium 1840 DAT 40 DAT 72 DAT 160 DLT VS160 SDLT 600 1U Rack-Mount Kit 3U Rack-Mount Kit HP StorageWorks USB Tape Drives, External DAT 40 USB DAT 72 USB DAT 160 USB 1U Rack-Mount Kit External USB 2.0 Port N/A HP StorageWorks SAS Tape Drives, External DA[...]
-
Página 35
MSL6000 HP StorageWorks D2D Backup Systems D2D110 D2D120 D2D130 External Embedded Network Controller N/A DA - 12477 Worldwide QuickSpecs — Version 36 — 2/29/2008 Page 35[...]
-
Página 36
Power Supply Specification - AC Part number 380622-001 Spare Kit 403781-001 Operational Input Voltage Range (Vrms) 90 to 264 Frequency Range (Nominal) (Hz) 47 to 63 (50/60) Nominal Input Voltage (Vrms) 100 120 208 220 230 240 Max Rated Output Wattage Rating 800 850 1000 1000 1000 1000 Nominal Input Current (A rms) 10.0 8.8 5.85 5.5 5.2 4.97 Max Rat[...]
-
Página 37
System Unit Dimensions (H x W x D) (with bezel) 3.38 x 17.54 x 26.01 in (8.59 x 44.54 x 66.07 cm) Weight (approximate) Maximum (all hard drives, power supply, and processor installed) 60 lb (27.22 kg) Minimum (one hard drive, power supply, and processor installed) 47.18 lb (20.41 kg) Input Requirements (per power supply) Rated Line Voltage 100 - 13[...]
-
Página 38
Acoustic Noise Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). Idle LWAd 6[...]
-
Página 39
Two Embedded NC373i Multifunction Server Adapters Network Interface 10Base-T/100Base-TX/1000Base-TX Compatibility IEEE 802.3 10Base-T IEEE 802.3ab 1000Base-T IEEE 802.3u 100Base-TX Data Transfer Method PCI Express, four lanes (x4) Network Transfer Rate 10Base-T (Half-Duplex) 10 Mb/s 10Base-T (Full-Duplex) 20 Mb/s 100Base-TX (Half- Duplex) 100 Mb/s [...]