HP (Hewlett-Packard) T2200 manual
- Consulta online o descarga el manual de instrucciones
- 61 páginas
- 1.67 mb
Ir a la página of
manuales de instrucciones parecidos
-
Power Supply
HP (Hewlett-Packard) 380976
20 páginas 0.66 mb -
Power Supply
HP (Hewlett-Packard) 665xA
47 páginas 2.08 mb -
Power Supply
HP (Hewlett-Packard) 6472C
29 páginas 1.69 mb -
Power Supply
HP (Hewlett-Packard) MA7200 Plus
12 páginas 0.75 mb -
Power Supply
HP (Hewlett-Packard) 66332A
75 páginas 0.47 mb -
Power Supply
HP (Hewlett-Packard) 217823-002
52 páginas 0.76 mb -
Power Supply
HP (Hewlett-Packard) 5998-1958
6 páginas 0.15 mb -
Power Supply
HP (Hewlett-Packard) HP T750J
38 páginas 0.35 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones HP (Hewlett-Packard) T2200. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica HP (Hewlett-Packard) T2200 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual HP (Hewlett-Packard) T2200 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales HP (Hewlett-Packard) T2200, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones HP (Hewlett-Packard) T2200 debe contener:
- información acerca de las especificaciones técnicas del dispositivo HP (Hewlett-Packard) T2200
- nombre de fabricante y año de fabricación del dispositivo HP (Hewlett-Packard) T2200
- condiciones de uso, configuración y mantenimiento del dispositivo HP (Hewlett-Packard) T2200
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de HP (Hewlett-Packard) T2200 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de HP (Hewlett-Packard) T2200 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico HP (Hewlett-Packard) en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de HP (Hewlett-Packard) T2200, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo HP (Hewlett-Packard) T2200, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual HP (Hewlett-Packard) T2200. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
HP R/T2 200 UP S User G uid e October 2006 (Third Edition) Part Number 404314-003[...]
-
Página 2
© Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to chan ge without no tice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such produc ts and services. Noth ing herein should be construed as constituting an additional w arranty. H[...]
-
Página 3
Contents 3 Con te nt s Component iden tifica tion ............................................................................................................... 6 UPS fron t panel ................................................................................................................ ......................... 6 UPS front panel controls and[...]
-
Página 4
Contents 4 UPS operates on battery only ................................................................................................... ................. 43 UPS frequently switches between utility and ba ttery power ...................................................................... ...... 43 UPS does not provide th e expected backup time ..[...]
-
Página 5
Contents 5 Preventing electros tatic discharge ............................................................................................. ................. 57 Grounding methods to preven t electrostati c discha rge ........................................................................... ....... 57 Acronyms and abbreviati ons .................[...]
-
Página 6
Component identification 6 C om ponent i den tif icati on In this section UPS fron t panel ................................................................................................................ ........................ 6 UPS front panel controls and LED in dicators ..........................................................................[...]
-
Página 7
Component identification 7 UP S fr ont panel co ntr ols and LED indi cato r s Item Description Function 1 Power On/Standby button Turns the UPS power on and off, an d places the UPS in Standby mode. 1 2 Power LED Green—The UPS is on and supplying connected equipment with AC power. Flashing green—The UPS is operating from its internal batteries [...]
-
Página 8
Component identification 8 Item Description Function 6 Battery Warning LED Red—During a self-test, the UPS found that the batteries must be recharged. Charge the batteries and repeat the self-test (" Initiating a self- test " on page 35 ). 7 Mute/Test button Silences UPS alarms and initiates a self-test (" Initiating a self-test &q[...]
-
Página 9
Component identification 9 Item Description 13 ERM connector For information about controlling load segments re motely, see "Po wer management software (on page 37 )." UP S R/T2 200 INTL r ear panel Item Description 1 Load segment 1 (one IEC-320-C 13 output receptacle for surge and battery backup protection) 2 Load segment 2 (one IEC-320-[...]
-
Página 10
Component identification 10 REPO port The UPS includes an RJ-11 type EPO port. The EPO fu nction can be used to power down the UPS output receptacles in an emergency. This fe ature is enabled by utilizing a normally open (N.O.) switch (option 1) or a normally closed (N.C.) switch (option 2). The EPO port is referred to as a REPO port when used in c[...]
-
Página 11
Component identification 11 To restore power to the load devi ces after the REPO feature is activated, press the Power On/Standby button after the AC source is reconnected to the UPS. IMPORTANT: Pressing and holding the Power On/Standby bu tton without utility present normally initiates a battery start and the UPS assumes the load. However, if the [...]
-
Página 12
Installation 12 Inst allati o n In this section Precautions .................................................................................................................... ........................ 12 Preparing to inst all the ha rdware .............................................................................................. ..............[...]
-
Página 13
Installation 13 Selecting a site WARNING: To prevent fire or electri c sh ock, install the unit in a temperature- and humidity-controlled indoor environmen t, free of conductive contaminants. When selecting a site, consider the f ollowing factors: • Elevated operating ambient temperature—If the equip m ent is installed in a closed or multi-unit[...]
-
Página 14
Installation 14 1. Remove the UPS front bezel. 2. Attach the logo badge above the LED/Control panel.[...]
-
Página 15
Installation 15 3. From inside the bezel, gently push out th e LED/Control panel and rotate 90 degrees. 4. Replace the front bezel.[...]
-
Página 16
Installation 16 5. Stand the unit on its side with the LED/Control panel at the top. Extend the tower stand to fit any configuration from 1U to 9U.[...]
-
Página 17
Installation 17[...]
-
Página 18
Installation 18 6. Adjust the fine adjustment screws to ensure the tower stands fit securely around the UPS and/or ERM. Inst alling the UP S in a r ac k Before installing the unit, review and adhere to all warnings provided in "Precautions (on page 12 )." WARNING: To reduce the risk of personal injury or damage to the equipment, be sure t[...]
-
Página 19
Installation 19 1. Attach the 2U side-mounting brackets to t he unit. 2. Loosen the wing nuts, and extend the brackets to the desired length.[...]
-
Página 20
Installation 20 3. Insert screws through the rack into the mounting ra il and the front of each mounting bracket. Do not completely tighten the screws. 4. Insert screws through the rack into the mounting ra il and the rear of each mounting bracket. Do not completely tighten the screws. 5. Wait until the unit is installed and the bracke ts are adjus[...]
-
Página 21
Installation 21 Connecting the batteries WARNING: The unit contains sealed lead-aci d ba ttery modules. To prevent fire or chemical burns: • Do not attempt to recharge batteri es after removal fr om the unit. • Do not disassemble, crush, or puncture the batteries. • Do not short the external contacts of the batteries. • Do not immerse the b[...]
-
Página 22
Installation 22 2. Connect the battery lead to the battery terminal. NOTE: A small amount of arcing may occur when conne cting the batteries. This is normal and does not damage the unit or present any safety concern. 3. Replace the UPS front bezel . 4. Attach the RETMA rail covers. NOTE: The HP logo and product name are printed on th e RETMA rail c[...]
-
Página 23
Installation 23 CAUTION: Do not set the Battery Charge Level switch to the down position without an ERM connected. There is a risk of damaging the intern al battery system of the UPS. NOTE: DIP switch 4 is inactive and does not af fect UPS operation regardless of the position. NOTE: An asterisk (*) indicates the default setting. Output voltage Inpu[...]
-
Página 24
Installation 24 IMPORTANT: If using HPPM, connect the Management Serv er to an unswitched output receptacle (" UPS R/T2200 INTL rear panel " on page 9 , " UPS R/T2200 NA/JPN/TWN rear panel " on page 8 ), and then set the Management Server as the last device to shut down, ensuring that all connected load devices are shutdown grac[...]
-
Página 25
Installation 25 Connecting the USB communications port CAUTION: Using a USB to serial converter cable will damage the UPS. Connecting the REPO port WARNING: To meet the requirements state d in NE C (NFPA 70) Articles 645-10 and 645- 11, a UPS installed in a computer equipment room must be connected to a REPO circuit. IMPORTANT: The remote switch mu[...]
-
Página 26
Installation 26 NOTE: Wire the connector block using stranded, nons hielded wire (AWG #22 - #18, or equivalent). Connecting the ground bonding cable The ground bonding screw is provided as an atta chment point for conductors. Use a ground bonding cable if the rack contains any conductors for th e purpose of functional grounding or bonding of ungrou[...]
-
Página 27
Installation 27 • Connect the device power cords to the output receptacles on the rear panel of the UPS (NA/JPN/TWN model). -or- • Connect devices to the output receptacles on th e rear panel of the UPS using the jumper cords included with the UPS (INTL model). Charging the UPS batteries Allow the batteries to charge befo re putting the UPS int[...]
-
Página 28
Installation 28 1. Attach the logo badge above the LED/Control panel.[...]
-
Página 29
Installation 29 2. Stand the unit on its side with the LED/Control panel at the top. Extend the tower stand to fit any configuration from 1U to 9U.[...]
-
Página 30
Installation 30[...]
-
Página 31
Installation 31 3. Adjust the fine adjustment screws to ensure the tower stands fit securely around the UPS and/or ERM. Inst alling the ERM in a r ack Before installing the unit, review and adhere to all warnings provided in "Precautions (on page 12 )." WARNING: To reduce the risk of personal injury or damage to the equipment, be sure tha[...]
-
Página 32
Installation 32 1. Attach the 2U side-mounting brackets to t he unit. 2. Loosen the wing nuts, and extend the brackets to the desired length.[...]
-
Página 33
Installation 33 3. Insert screws through the rack into the mounting ra il and the front of each mounting bracket. Do not tighten. 4. Insert screws through the rack into the mounting ra il and the rear of each mounting bracket. Do not tighten. 5. Tighten the wing nuts. 6. Wait until the unit is installed and the bracke ts are adjusted before tighten[...]
-
Página 34
Installation 34 This symbol indicates the presence of el ec tric shock hazards. The area contains no user or field serviceable parts. Do not open for any reason. WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure. Plug the ERM cable into the socket at the rear of the UPS. Attaching the RETMA rail covers NO[...]
-
Página 35
UPS operations 35 UP S oper atio ns In this section Initiating a self-test ......................................................................................................... ......................... 35 Silencing an au dible al arm ..................................................................................................... .........[...]
-
Página 36
UPS operations 36 UPS provides sine wave power from the battery reserves for as long as the distorti on is present. In areas with poor utility power or where the UPS in put power comes from a backup generator, continuous waveform distortion causes the UPS to switch to batte ry power. To minimize batte ry use, experiment with different settings for [...]
-
Página 37
Power management 37 P o w er management In this section Power manageme nt software ...................................................................................................... ............. 37 P o w er manage men t s o ftw ar e HP Power Manager softwar e ensures maximum power reliability of comput er systems through comprehensive contr ol[...]
-
Página 38
Maintenance 38 Maintenance In this section Updating the UP S firm ware ...................................................................................................... ............... 38 Replacing th e batte ries ........................................................................................................ .................... 38 Cl[...]
-
Página 39
Maintenance 39 Battery care and storage guidelines CAUTION: Because of the short shelf life of the batteri es, avoid storing a battery spare as a backup. Do not maintain an inventory of spare batteries on site un less a procedure to keep thes e batteries charged while in storage is implemented. To maintain the batteries: • Minimize the amount of [...]
-
Página 40
Maintenance 40 3. Disconnect the battery leads. 4. Remove the battery bracket. 5. Remove the UPS battery modules.[...]
-
Página 41
Maintenance 41 IMPORTANT: Do not pull the battery leads when removing or installing the batteries. To replace the component, reverse the r emoval procedure. IMPORTANT: Charge the batteries for at least 24 hours before supplying backup power to devices. The batteries charge to: • 90% of their capacity within 4 hours • 100% of their capacity with[...]
-
Página 42
Troubleshooting 42 T r oubleshooting In this section UPS does no t start ............................................................................................................. ..................... 42 UPS does not communicate with the host compu ter ................................................................................ ..... 42 UPS[...]
-
Página 43
Troubleshooting 43 2. Check the troubleshooting i nformation in this do cument to determine the cause of the alarm. C ir c uit br eak er tr ips Action: Remove some of the load, and then press the circuit breaker to reset the load. UP S oper ates o n batter y o nl y Action: 1. Save your work. 2. Power down the load devices connected to the UPS outpu[...]
-
Página 44
Troubleshooting 44 If the Battery Charge LED is also red: a. Save your work, and power down the UPS (" Powering down the UPS " on page 36 ). b. After the blackout or brownout is over, power up the UPS (" Powering up the UPS " on page 27 ). c. Allow the UPS batteries to charge for 24 hours. If the Battery Charge LED is also yello[...]
-
Página 45
Specifications 45 Sp e c i fica t io ns In this section UPS physical sp ecifications.................................................................................................... .................. 45 ERM physical sp ecifications .................................................................................................... .............[...]
-
Página 46
Specifications 46 UP S output spec if i cati ons UPS model Output receptacles Maximum current R/T2200 NA/JPN/TWN 4 x NEMA 5-15R, 4 x NEMA 5- 15/20R 18.3 A R/T2200 INTL 8 x IEC-320-C13 9.5 A Power protection specifications UPS model VA Nominal power rating (W) Nominal voltage setting R/T2200 NA/JPN/TWN 2200 1600 100, 110, 120 R/T2200 INTL 2200 1600 [...]
-
Página 47
Specifications 47 Battery spec if i cati o ns Feature Specification Type 12 V, 9 AH, sealed, maintenance- free, rechar geable, lead-acid battery Voltage The battery modules have a battery string voltage of 48 V. Charging Complete charge takes no more than 24 hours. After approximately 4 hours, the batteries reach 90% charge at default nominal utili[...]
-
Página 48
Spares 48 S par e s In this section Ordering spar es ................................................................................................................ ..................... 48 Spare parts list ............................................................................................................... ........................ 48 Ha[...]
-
Página 49
Technical support 49 T ec hni cal su ppo r t In this section Before you contact HP.......................................................................................................... ................... 49 HP contact in formation ......................................................................................................... ........[...]
-
Página 50
Warranty information 50 W a rran t y i n fo rm at io n In this section Limited wa rranty ............................................................................................................... ..................... 50 $250,000 Computer Load Pr otection Gu arantee ..............................................................................[...]
-
Página 51
Warranty information 51 • Notification from power management software[...]
-
Página 52
Regulatory compliance notices 52 R e gulatory com pli ance noti ces In this section Regulatory compliance id entification nu mbers ................................................................................... ........ 52 Federal Communications Commissio n notic e ................................................................................[...]
-
Página 53
Regulatory compliance notices 53 Class A equipment This equipment has been tested and found to comply wi th the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are design ed to provide rea sonable protection against harmful interference when the equipment is operated in a commercial environment. This equipmen[...]
-
Página 54
Regulatory compliance notices 54 Modif i cati ons The FCC requires the user t o be notified that any ch anges or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user’s authority to operate the equipment. Cabl es Connections to this device must be made with shielded cables with metallic RFI[...]
-
Página 55
Regulatory compliance notices 55 Dispo s al of w as te eq uipme nt b y use r s in pr i v ate hou seho lds in the E ur opean U ni on This symbol on the product or on its packagi ng indicates that this product must not be disposed of with your other household waste. Inst ead, it is your respon sibility to dispose of your waste equipment by handing it[...]
-
Página 56
Regulatory compliance notices 56 K or ean no ti ce Class A equipment Class B equipment Bat ter y r eplacement not i ce WARNING: Power products contain sealed lead- acid battery modules. A risk of fire and burns exists if the battery is not properly handled. To reduce the risk of personal injury: • Do not attempt to recharge the battery. • Do no[...]
-
Página 57
Electrostatic discharge 57 Elec tr o stati c disc har ge In this section Preventing electros tatic discharge ............................................................................................. ................ 57 Grounding methods to preven t electrostati c discharge ........................................................................[...]
-
Página 58
Acronyms and abbreviations 58 A c r on y ms and a bbr e v i ations EPO emergency power off ERM extended runtime module HPPM Hewlett-Packard Power Manager IEC International Electrotechnical Commission LED light-emitting diode NEC National Electrical Code NEMA National Electrical Manufac turers Associa tion PFC power factor corr ected REPO remote eme[...]
-
Página 59
Index 59 A alarm conditions 35 alarms, silencing 35 authorized reseller 49 B backup time, insufficient 43 batteries, care and storage 39 batteries, charging 27, 34 batteries, cleaning spills 41 batteries, connecting 21 batteries, replacing 38, 39 batteries, runtime 47 batteries, specifications 47 battery cables, connecting 21 Battery Charge LED, lo[...]
-
Página 60
Index 60 installing the UPS 13 insufficient backup time 43 International model 9 J Japanese notice 55 K Korean notices 56 L LED, power button 7 LEDs 6, 7 LEDs, troubleshooting 42 limited warranty 50 load protection guarantee 50 load segments, location 8, 9 low-voltage UPS 8 M maintenance 38 models, high-voltage UPS 9 models, low-voltage UPS 8 modif[...]
-
Página 61
Index 61 U Uninterruptible Power System, high-voltage models 9 Uninterruptible Power System , low-voltage models 8 UPS does not start 42 UPS operations 35 UPS, installing 12, 13 USB connectors 25 V Voltage Correction LED, location 7 Voltage Correction LED, troubleshooting 44 voltage specifications 46 voltage, configuring 22 W warranties 50 weight, [...]