Kobe Range Hoods CH9636SQB manual
- Consulta online o descarga el manual de instrucciones
- 35 páginas
- 1.27 mb
Ir a la página of
manuales de instrucciones parecidos
-
Ventilation Hood
Kobe Range Hoods IS2442GSB
24 páginas 0.89 mb -
Ventilation Hood
Kobe Range Hoods CH2742SQB
102 páginas 2.11 mb -
Ventilation Hood
Kobe Range Hoods CH8136SQ
21 páginas 1.27 mb -
Ventilation Hood
Kobe Range Hoods CX1830GS-8
25 páginas 0.86 mb -
Ventilation Hood
Kobe Range Hoods CH0142SQB (42")
36 páginas 0.8 mb -
Ventilation Hood
Kobe Range Hoods CH0042SQB
36 páginas 2.18 mb -
Ventilation Hood
Kobe Range Hoods CH9630SQB
35 páginas 1.27 mb -
Ventilation Hood
Kobe Range Hoods CH-191
27 páginas 2.51 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Kobe Range Hoods CH9636SQB. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Kobe Range Hoods CH9636SQB o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Kobe Range Hoods CH9636SQB se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Kobe Range Hoods CH9636SQB, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Kobe Range Hoods CH9636SQB debe contener:
- información acerca de las especificaciones técnicas del dispositivo Kobe Range Hoods CH9636SQB
- nombre de fabricante y año de fabricación del dispositivo Kobe Range Hoods CH9636SQB
- condiciones de uso, configuración y mantenimiento del dispositivo Kobe Range Hoods CH9636SQB
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Kobe Range Hoods CH9636SQB no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Kobe Range Hoods CH9636SQB y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Kobe Range Hoods en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Kobe Range Hoods CH9636SQB, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Kobe Range Hoods CH9636SQB, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Kobe Range Hoods CH9636SQB. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
K O B E B r a n d R a n g e H o o d Mod el No. CH96 30SQB (30”) CH9636SQB (3 6”) CH9642SQB (4 2”) CH9648SQB (4 8”) CH-196 SERIES – 10” HEIGHT INST ALLA TION INSTRUCTIONS AND OPERA T ION MANUAL[...]
-
Página 2
- READ A N D SA VE T HESE I NST RUCT IONS - CONT ENTS IMPOR T ANT SAFETY INSTRUC TIONS .........................................................................1 COMPONEN TS OF P ACKAGE .......................................................................................3 INST ALL A TION ...........................................................[...]
-
Página 3
1 IMPORT ANT SAFET Y INSTRUCT IONS - PLEASE READ T HIS SE CT ION CA REFUL L Y BE FO RE INST ALLA TION - W ARNIN G: TO REDU CE THE RISK OF FIRE, ELECTRIC SH O CK OR PERS ONA L INJUR Y , OBSERVE T HE FOLLOWI NG: 1) Installation a nd el ect rical wir ing mu st be done b y qualif ied professiona ls and in accordance with all applicable codes and sta nd[...]
-
Página 4
2 W hat to D o In The Event O f a Range T op Grease Fir e • SMOTHER FL AMES wit h a close f itting lid, cooki e sheet, or metal tray , and then t urn off the bu rner . KEEP FLAMM ABL E O R COM BUSTIBLE MA TE R IAL A WA Y FROM FLAMES. If the f lam es do not go out immediately , E V ACUA TE TH E ARE A A ND C AL L TH E FIRE DEP A R TMENT or 91 1. ?[...]
-
Página 5
3 COMPONENTS OF P ACKAGE (Must keep all material for r eturns or refunds) Range Hood Box Duct Co ver Box (Sold Se parately) {A} KOBE Range Ho od {B} W ar ranty Regis tratio n Card {C} In st ructio n Manual {D} Baffle F ilter -- 2 (30” , 36”, 42”) -- 3 (48”) {E} St ainless Steel S pacer -- 2 (30”) -- 2 (36”) -- 3 (42”) -- 2 (48”) {F}[...]
-
Página 6
4 INST ALL A T ION PLEASE READ ENTIRE INSTRUCT IONS BEF ORE PROCEEDING Calculatio n before Inst alla tion T o calculate i nstallation, please refer to T ABLE 1 or T A BLE 2. (All calculation i n in ches.) - FO R UNDER T HE CABINET - T ABLE 1 A = Height of Floor to C eiling B = H eig ht of Floor to Counter T o p (S t anda r d: 36”) C = Preferred H[...]
-
Página 7
5 SAFETY WA RNIN G H OOD MA Y HA V E VE R Y SHA RP EDGES; PLEA SE WEA R PROTECT IVE GLOVES I F IT IS N ECES S A R Y TO RE M OV E A NY P A RTS FOR I NST A LLING , CLE A NIN G O R SERVICI N G . N OT E: BE C A REFU L WH E N USING ELECT RICA L SCR EWDRIVER, DAMA GE TO THE H OOD MA Y OCCUR. Installation C onten ts UNDER THE CABINE T INST ALL A TION ....[...]
-
Página 8
6 UNDER T HE CA B INET INST ALLA T ION P r e p a r a t i o n b e f o r e I n s t a l l a t i o n NOTE: TO A VOID DAM AGE TO YOUR HO OD, PREVENT DEBRI S FROM ENT ERING THE VENT OPENI NG . • Decide the location of the v enting pipe f r om the hood to the outside. Refer to Figure 1. • A stra ight, short vent run will allow the hood to perform more[...]
-
Página 9
7 4. Draw electrical wires through c abinet acces s o pening. 5. From inside of the hood, p l ace screw (not provided) into the exact center of each knockout hole and secure to cabinet bottom. Once all mounti ng screws are in pla ce, f i nish tig htening screws u nt il secure. CAUTI ON : MAKE SUR E T H E H OOD IS SECURE BEFORE RELEA SING . 6. For s[...]
-
Página 10
8 A c c e s s o r i e s 9. Drop o il tunnel into recess support near re ar of hood. Refer to Figure 6. 10. Inst all b af fle f ilte rs and stainl ess sp acer(s). Refer t o Me as urem ents and Di agr ams on pa ge 22 fo r baffl e filt er and s tainl ess sp acer pla cem ent. Angle baffle f ilter toward ba ck o f hood . Push baffle filter up until [...]
-
Página 11
9 ST AND A LONE INST A LL A T ION *** This i nstallation only applies if installing wit h the CH1 1 20DC duct cover . P r e p a r a t i o n b e f o r e I n s t a l l a t i o n NOTE: T O A VOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENI NG . • Decide the location of the venting pipe f r om t he hood to the ou tsid e. (Figure [...]
-
Página 12
10 1. Using re fe rences in T A BLE 1 and M ea surements and Diagrams on p ages 19-21, mark th e le veling poin t of the hood. Positio n two mo unting screws (no t p rovided) o n the wall, leaving 1/8” sp ace a w ay f rom the wall. 2. Pu nctur e t he knockout wire access h ole at the back of the hood and draw the ele ctri cal wires through as sho[...]
-
Página 13
11 D u c t C o v e r I n s t a l l a t i o n 6. Mark the p osition of t he in ner duct c over- mounting bracket {J} (provide d). Use reference E from T ABLE 2 a nd M ea surements and Diagrams on p age 20-2 1. Attach and sec ure inner duct cover- mounting bracket {J} with two scr ews (not provided) to the wall. Refer to Figure 15. NOTE: Inner duct c[...]
-
Página 14
12 F i n a l A s s e m b l y 14. T u rn po wer ON in control pa ne l. Check a ll light and fan operation. 15. M ake su re to leave th is manual for the homeowner . Figure 19 1 2 3 4 5[...]
-
Página 15
13 OPERA T ION I NST RUCT IONS This KOBE hoo d is equi pped with six electronic contr ols, two powerful ce ntr i fugal squ ir rel cages with sta i nless steel oil tu nne l , sta i nless steel ba ff le filters and spacer(s), and bright 12- vol t 20-watt halogen lights (2 for 30” & 36” and 3 f or 42” & 48”). The six electronic button [...]
-
Página 16
14 Figure 21 T urnin g Fan OFF: The 3-Minute Delay fun ction w il l only turn o ff f ans. The light se ttings w il l not be affected by the del ay function. 3-Min ute Delay - Press Pow er Co ntrol (On/Off) button once , th e LED li ght for th e ac tive sp eed will f lash and fa ns will shut off afte r 3 m in utes. - During this 3-m i nute delay , c[...]
-
Página 17
15 MAINT ENA NCE SAFETY WAR NIN G NEVER PUT YOUR HA ND INTO AREA HOU SING THE F A N WH ILE T HE F AN IS OPERA T IN G . For optimal operation, clean ran ge hood and all ba ffle/spacer/ f ilter/oil tunnel/oil co ntainer regularly . T o Clean Hood Surface CAUTI ON : N EV ER USE A BRAS IVE CLEAN ERS, P A DS, OR CLOTHS. *** Regular care will help preser[...]
-
Página 18
16 T o Replace Light Bul b CAUTI ON : HA LOGE N L IGH T UNIT MA Y BE HOT! W AI T UNTIL UN IT IS COO L. 1. Make sure all controls are of f, and range hood is unplugged. 2. Place a flat- head screwdriver between li gh t cover and hou si ng to remove cover . 3. Gently pu ll d efec[...]
-
Página 19
17 SPECIFICA T IONS MODEL / SIZE CH96 30SQB / 30” CH96 36SQB / 36" CH96 42SQB / 42” CH96 48SQB / 48” COLOR #304 Comm erc i a l Grade S ta i n less S teel CONSUMP TION / A M PERE CH96 30SQB – 300 W / 3A CH96 36SQB – 300 W / 3A CH96 42SQB – 300 W / 3A CH96 48SQB – 300 W / 3A VOL TA GE 120V 60 Hz NUMBER O F MO TORS 2 DESIGN Seamles [...]
-
Página 20
18 MEASUREMENT S & DIAGRAMS A ll ( ) a re in mi llimeter . A ll inch measurements are converted from millim eters. Inch measurement s are esti mated. - FO R UNDER T HE CABINET - MODEL NO: CH9630 SQB CH963 6 SQB CH964 2 SQB CH964 8 SQB[...]
-
Página 21
19 A ll ( ) a re in mi llimeter . A ll inch measurements are converted from millim eters. Inch measurement s are esti mated. - FO R S T AND A L ONE (WIT H OPTIONAL DU CT COVER) - MODEL NO: CH9630 SQB CH963 6 SQB CH964 2 SQB CH964 8 SQB[...]
-
Página 22
20 Rear Knocko ut Holes 2 4 " ( 6 0 8 ) f o r 4 2 " 3 0 " ( 7 6 0 ) f o r 4 8 " 1 8 " ( 4 5 6 ) f o r 3 6 " 3 " ( 7 5 ) 3 " ( 7 5 ) 3 " ( 7 5 ) 3 " ( 7 5 ) 1 2 " ( 3 0 4 ) f o r 3 0 "[...]
-
Página 23
21 Hood-Mounting Bracke t DUCT COVER-MOUN T ING BR ACKE T I nn er Duct Cove r-Mounting Br acket Outer Duct Cover- Mounting Br acket 8 - 5 / 8 " ( 2 2 0 ) 1 1 - 3 / 4 " ( 2 9 8 ) 7/8" (22) 1/8" (4.5) 3 - 1 / 8 " ( 8 0 ) 2 - 1 / 4 " ( 5 7 ) 1/8" ( 3.4) 9" (2 28) 10-1/4" (260) 9" (228) 4-3/4" (120[...]
-
Página 24
22 BA FF LE F IL T ER & S T AINLESS ST EEL SP ACERS 48 ″ H00D 42 ″ H00D 30 ″ H00D 36 ″ H00D[...]
-
Página 25
23 P ART S LIST M ODEL N O.: CH 96 30SQB CH 96 36 SQB CH 96 42 SQB CH 96 48 SQB Body Compo nents NO. DESCRIPTION MODEL/SIZE P AR T NO. 1 Screws (3/16” x 3/8”) CH196- 1 2 Hood Ca sing CH196- 2 3 Hood- Mounting Bracket CH196- 3 4 Screws (3/16” x 3/8”) CH196- 1 5 S tai nless S teel Oil T unnel CH196- 4 6 Blower Asse mbly CH196- 5 7 Hal ogen Li[...]
-
Página 26
24 3 2 1 4 5 6 7 1 0 8 9 1 5 1 6 1 8 1 9 1 7 1 4 1 3 1 1 1 2 B 1 2 C 1 2 1 2 A 2 0 2 1 2 2 1 2 D[...]
-
Página 27
25 Blower Assembly NO. DESCRIPTION MODEL/SIZE P ART NO. 1 Air Chamber CH196- 6.1 2 Screw Cap CH196- 6.2 3 Left Squirrel Cage CH196- 6.3 4 Left Locknut CH196- 6.4 5 Air Flow Grill CH196- 6.5 6 Screws (3/16” x 3/8”) CH196- 6.6 7 Rig ht Locknut CH196- 6.7 8 Rig ht Squirrel Cage CH196- 6.8 9 Gasket CH196- 6.9 10 Screw s (3 /16” x 3/8”) CH196-6 [...]
-
Página 28
26 Electrical A ssemb ly NO. DESCRIPTION MODEL/SIZE P ART NO. 1 Elect rical Box CH196- 15.1 2 Screws (3/16” x 3/8”) CH196- 15.2 3 Processor Board CH196- 15.3 4 Elect rical Box Cover CH196- 15.4 5 Setup Boar d CH196- 15.5 6 Gasket CH196- 15.6 7 Screws (3/16” x 3/8”) CH196- 15.2 8 T ransf orm er CH196- 15.7 9 Screws (3/16” x 3/8”) CH196- [...]
-
Página 29
27 CIRCUIT DIAGRAM M ODEL N O.: CH 96 30SQB CH 96 36 SQB MOTOR MOTOR CAPACITOR 10uF/450V CAPACITOR 10uF /450V TRANSFORMER PROCESSO R BOARD CONTROL BOARD HALOGEN LIGH T RED BLACK WHITE YELLOW GREEN BROWN BROWN RED RED GREEN GREEN WHITE WHITE RED BLACK BLACK BLACK WHITE RED 120V 60Hz[...]
-
Página 30
28 M ODEL N O.: CH 96 42SQB CH 96 48 SQB 120V 60Hz RED WHITE BLACK BLACK BLACK RED WHITE WHITE GREEN GREEN RED RED BROWN BROWN GREEN YELLOW WHITE BLACK RED HALOGEN LIGHT CONTROL BOARD PROCESSOR BOARD TRANSFORMER CAPACITOR 10uF/450V CAPACITOR 10uF/450V MOTOR MOTOR[...]
-
Página 31
29 DISCLAIMER 1. C A RE FULL Y INSPECT A L L ITE MS FO R D AMAGES BEF ORE A CCEP TING DE LIVER Y . N OT E A NY DAMAGES ON T H E FREIGH T BILL OR E XPRESS RECEI PT . REQUEST NAM E AND SIGNA T URE OF T HE CA RR IER’S A GE NT A ND KEEP C OPY T O SUPPORT YOU R CL A IM. Upon accepta nce of items, owner assumes responsibility f or its safe a rrival. Re[...]
-
Página 32
30 W ARR AN T Y W ARRAN T Y CERT IFI C A T E KOBE Range Hoods, Inc. warra nts all products m anufa ctured or supp li ed by it to b e f ree from de fects in workmanship and materials. Its obligations p ursuant t o this w arranty a re lim ited to a period of two years f rom the d ate of purchase and to the rep air or replacement at its o ption and su[...]
-
Página 33
31 3) The purchaser shall b e responsible fo r any e xp en ses involved in m aking the range hood re adil y acces si ble for servicing and where the r ange h ood is installed outsi de the main sales te rrit ory of the retailer or service territory of th e nearest approv ed KO BE Ran ge Hoods Agen t a s applic ab le, fo r an y traveling expenses and[...]
-
Página 34
32 PRODUCT REGISTRA T ION Regist er Y our P roduct! Any covere d failure occu rrin g within two year s of original purchase arising f rom d efe ctive workmanship o r ma terial in manu fac ture will be repaired o r at our opt ion the unit will be replaced f r ee o f charge by an authorized KOBE Range Hoods Agent or KOBE Ran ge Hoods as applic ab le.[...]
-
Página 35
KOBE Range Hoo ds 10505 V alley Bl vd Suite # 302 El Monte , CA 9173 1 USA http:// www .K OB ERan geH oods.c om This KOBE ho od is m anu factur ed f or use i n the USA and C ANADA only . W e do not recommend usi ng this hood overseas as the po wer su pply m ay not be compatible and m ay vio l ate t he electrical code of that country . Using a KOBE [...]