Louisville Tin and Stove 78111 manual
- Consulta online o descarga el manual de instrucciones
- 27 páginas
- 0.46 mb
Ir a la página of
manuales de instrucciones parecidos
-
Furnace
Louisville Tin and Stove DVCF403B-R
22 páginas 0.28 mb -
Furnace
Louisville Tin and Stove W355F
20 páginas 0.23 mb -
Furnace
Louisville Tin and Stove HEDV253A
2 páginas 0.18 mb -
Furnace
Louisville Tin and Stove 90N75A
19 páginas 0.26 mb -
Furnace
Louisville Tin and Stove W506
20 páginas 0.23 mb -
Furnace
Louisville Tin and Stove W256F
25 páginas 0.3 mb -
Furnace
Louisville Tin and Stove W505F W256F
20 páginas 0.23 mb -
Furnace
Louisville Tin and Stove CF354C-R
28 páginas 0.33 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Louisville Tin and Stove 78111. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Louisville Tin and Stove 78111 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Louisville Tin and Stove 78111 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Louisville Tin and Stove 78111, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Louisville Tin and Stove 78111 debe contener:
- información acerca de las especificaciones técnicas del dispositivo Louisville Tin and Stove 78111
- nombre de fabricante y año de fabricación del dispositivo Louisville Tin and Stove 78111
- condiciones de uso, configuración y mantenimiento del dispositivo Louisville Tin and Stove 78111
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Louisville Tin and Stove 78111 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Louisville Tin and Stove 78111 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Louisville Tin and Stove en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Louisville Tin and Stove 78111, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Louisville Tin and Stove 78111, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Louisville Tin and Stove 78111. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
COUNTERFLOW W ALL FURNACE INST ALLA TION AND OPERA TING INSTRUCTIONS P/N 781 1 1 REV . 10/08 MODEL NUMBERS W ARNING: Operation of this furnace when not connected to a pr operly installed and maintained venting system can result in Carbon Monoxide (C.O.) poisoning and possible death. For your safety , this furnace and the venting system should be in[...]
-
Página 2
INTRODUCTION THIS IS A GAS-FIRED, GRA VITY VENTED W ALL FURNACE THA T WILL OPERA TE SAFEL Y AND PROVIDE AN EFFICIENT SOURCE OF HEA T WHEN INST ALLED, OPERA TED AND MAINT AINED AS RECOMMENDED IN THESE INST ALLA TION AND OPERA TING INSTRUCTIONS. READ THESE INSTRUCTIONS THOROUGHL Y BEFORE INST ALLING , SER VICING , OR USING THE APPLIANCE. IF YOU DO NO[...]
-
Página 3
SAFETY RULES 1 . Improper installation, adjustment, alteration, service or maintenance can cause property damage, bodily injury or death. If you do not understand these instructions or your local codes, call local authorities, a qualified installer , service agency , gas su pplier , or the manufacturer . 2 . Do not install this fan type wall furnac[...]
-
Página 4
VENTING - CONTINUED This appliance is equipped with a blocked flue switch. W ARNING: Do not bypass the blocked flue switch. T o do so could expose the consumer to pr operty damage, personal injury or possible death. This switch, when activated, will interrupt the electrical circuit between the transformer and the gas valve causing the main burner f[...]
-
Página 5
COMBUSTION AND VENTILA TION AIR When installed, this gas appliance must be provided with fresh air for combustion, ventilation, and dilution of hot flue gases. The minimum required volume of the area where the appliance is installed should be 50 cubic feet per 1,000 btu/hr . If installed in an area of the home that is considered an unconfined space[...]
-
Página 6
LOCA TION AND SPECIAL PRECAUTIONS The wall furnace should be located near the center of the house for best heat distribution. If the area where the appliance is to be installed contains carpeting, tile or combustible materials, other than wood flooring, the appliance shall be installed on a metal plate, wood panel or other non-combustible materials[...]
-
Página 7
GAS ROUGH-IN Check local codes for requirements as to the size and type of gas line required. See Figure 5 for location of gas inlet holes in furnace cabinet. Compounds used on threaded joints of gas pipe should be resistant to the action of liquefied petroleum gases. The gas line joints must be checked for leaks. This should be done with a soap so[...]
-
Página 8
INST ALLA TION / WHEN RECESSED (UP T O 9-1/4”) STEP 1 . Cut out floor plate between 2x4 studs, so heater will set flat on floor . STEP 2 . Make electrical connection of 1 15 V . wiring into junction box provided on top of header plate. STEP 3. Attach the base plate (purchased with the vent pipe) to the header plate using two No. 8 sheet-metal scr[...]
-
Página 9
Installation of B-W Gas V ent for one-story buildings or for first floor of multi-story buildings. Ceiling plate spacers to center B-W Gas V ent in stud space - nail securely at both ends. Plate cut away for full width of stud space to provide ventilation. Studs on 16 inch centers Sheet metal screw base plate to header Use manufacturer’s method o[...]
-
Página 10
CF353C-H, CF354C-H, CF503C-H, CF504C-H, CF653C-H, CF654C-H ST ANDING PILOT FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot, which must be lighted by hand. When lighting the pilot, fo[...]
-
Página 11
CF357C-H, CF358C-H, CF557C-H, CF558C-H - I.I.D. PILOT FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. LIGHTING INSTRUCTIONS T O TURN OFF GAS TO APPLIANCE Page 11 1. Turn thermostat to it’ s lowest setting. 2. [...]
-
Página 12
PROPER BURNER FLAME A proper flame will have a dark blue inner mantle that sits right on top of the burners with a lighter blue outer mantle rising above the burner , (See Figure 1 1). There may be some yellow where the pilot flame and burner flame meet. There is no primary air adjustment on the burner , and proper flame is assured since the correc[...]
-
Página 13
TERMINAL BLOCK WIRING DIAGRAM CAUTION: Label all wires prior to disconnection when servicing controls. W iring errors can cause improper and dangerous operation. V erify proper operation after servicing. AUXILIAR Y LIMIT SWITCH For your safety this furnace is equipped with a manual reset auxiliary limit switch. In case of failure by the primary lim[...]
-
Página 14
CF353C-H, CF354C-H ST ANDING PILOT CF503/504C-H, CF653/654C-H Page 14 CF353C-H, CF354C-H PICTORIAL SCHEMA TIC Thermostat Power Cord Black Black Green White White Black Black Black White Black Black Brown Blue Black Transformer Motor Spill Switch Limit Switch Fan Switch Brown Blue Black TH TR Gas V alve Auxiliary Limit Switch MOTOR F AN SWITCH LIMIT[...]
-
Página 15
CF357C-H, CF358C-H I.I.D. CF557C-H, CF558C-H Page 15 BLACK BLACK BLACK AUXILIAR Y LIMIT SWITCH SPILL SWITCH PILOT IGNITION MODULE MV/PV GAS V A L VE LIMIT SWITCH FAN SWITCH SELECTOR SWITCH BLACK BROWN BLUE TRANSFORMER MOTOR WHITE BLACK BLACK BROWN BLACK GREEN WHITE WHITE BLACK THERMOST A T POWER CORD RED RED GREEN CF557C-H, CF558C-H PICTORIAL SCHEM[...]
-
Página 16
ROUGH-INS FOR REAR OR SIDE DISCHARGE Install plastergrounds as shown in Figure 12 and Figure 13. NOTE: When side dischar ge is being used, furnace should be set exactly 4” from side wall. 14-3/8” 10-3/ 16” Plaster Ground SIDE FIGURE 13 REAR FIGURE 12 OPTIONAL ACCESSOR Y KITS REAR REGISTER KIT (Flush Mount) (See Figur e 14) 1. Use optional kit[...]
-
Página 17
SIDE DISCHARGE ON CASING 1. Use optional kit No. 306SR-A. 2. Cut out and remove embossed area on casing side. 3. Remove knockout from inner liner . 4. Place 1-1/2” boot from kit through opening, matching flanges of boot to knockout on inner boot. 5. Mark screw holes and remove boot. 6. Drill holes with a 1/8” drill. 7. Attach inner boot with sc[...]
-
Página 18
SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Flame too large 1. Defective operator section of gas valve. 1. Replace complete valve. 2. Burner orifice too large. 2. Check with local gas company for proper orifice size and replace. 3. If installed above 2,000 ft. 3. Refer to orifice chart on Page 9. Noisy Flame 1. Noisy pilot. 1. Reduce pilot gas with a[...]
-
Página 19
SYMPT OM POSSIBLE CAUSES CORRECTIVE ACTION Pilot won’t light, 1. Air in line. 1. Bleed line. or stay lit 2. Defective thermocouple. 2. Replace thermocouple. (ST ANDING PILOT) 3. Pilot flame too low . 3. Adjust pilot flame. 4. Manual reset switch not engaged. 4. Push on button. Pilot won’t light, 1. Sparker won’t work. 1. Check wire connection[...]
-
Página 20
REV . 03/05 COUNTERFLOW W ALL FURNACE / ST ANDING PILOT Prices and specifications subject to change without notice. All prices are F .O.B. factory . MODELS: NA T . GAS L.P . GAS CF353C-H CF354C-H CF503C-H CF504C-H CF653C-H CF654C-H CONTROL ASSEMBL Y Page 20 26 24 14 25 34 5 10 11 4 27 29 28 12 30 13 35 1f 31 1e 1 1b 1d 1c 32d 34b 3 32b 33 32c 39 1a[...]
-
Página 21
Page 21 * REQUIRES TWO REV . 03/2005 MARCH 2009 HOW T O PROPERL Y ORDER P AR TS : In addition to part description and part number , please give model number, serial number , and type of gas used. This information can be found on the rating plate that is attached to heater . N AT UR AL MO DEL N UMB ER L. P . C F654C - H RE F. P A RT L I S T P A RT L[...]
-
Página 22
REV . 03/05 COUNTERFLOW W ALL FURNACE / I.I.D. PILOT Prices and specifications subject to change without notice. All prices are F .O.B. factory . MODELS: NA T . GAS L.P . GAS CF357C-H CF358C-H CF557C-H CF558C-H CONTROL ASSEMBL Y Page 22 33 32b 3 34b 32d 32c 39 1a 1c 1d 1b 1 1e 31 1f 35 30 13 12 27 28 11 10 5 4 34 25 14 24 26 50 51 6 32 15 52 2 7 8 [...]
-
Página 23
HOW T O PROPERL Y ORDER P AR TS: In addition to part description and part number, please give model number , serial number , and type of gas used. This information can be found on the rating plate that is attached to heater . Page 23 *REQUIRES TWO REV . 03/2005 MARCH 2009 NAT UR AL M ODEL NUMBER S L. P . RE F. P A RT LIS T P A RT LI S T P A RT D E [...]
-
Página 24
REV . 03/05 Page 24 KIT NO. 31300-A TRIM KIT VENT ENCLOSURE KIT NO. 16VE-A or 36VE-A KIT NO. 406RR-A REAR REGISTER W/ BOOT - FLUSH KIT NO. 407RR-A REAR REGISTER - RECESS KIT NO. 30SRB-A SIDE REGISTER W/BOOT KIT NO. 306SR-A SIDE REGISTER - FLUSH For description of above refer ence numbers, see reverse side. 15 14 2 4 1 3 5 16 8 7 12 7 8 12 11 5 12 9[...]
-
Página 25
Page 25 MARCH 2009 REV . 03/05 P ART DE S CRIP T IO N RE F . NO . P ART NO. L IS T P RICE 16" V ent E nc los ur e S i de 1 31360 9. 10 $ 16" V ent E nc los ur e F ront 2 31355 11. 40 $ 24" V ent E nc los ur e S i de 1 31367 14. 00 $ 24" V ent E nc los ur e F ront 2 31366 17. 20 $ 36" V ent E nc los ur e S i de 3 31385 17. 0[...]
-
Página 26
IMPOR T ANT SAFETY BULLETIN ON YOUR GAS CONTROL AND PILOT LIGHT SYSTEM FOR HEA TING EQUIPMENT WHA T YOU DON’T KNOW CAN HURT YOU. Y our pilot light system has been designed for safe and r eliable operation. Although safety mechanisms are built-in, the potential for hazard exists. This information is intended to help you avoid these hazards. YOUR G[...]
-
Página 27
LIMITED WARRANTY The Louisvil le Tin & Stove Co. warran ts to the original user the accom panying produ ct for the period specified herein, provided said product is installe d , operated, maintaine d , service d , and used according to the i nstructions and sp ecific ations accompanying the product. AS OUTL INED IN OUR INST RUCTIONS, ANY WARRAN[...]