Metrologic Instruments MS1690 manual
- Consulta online o descarga el manual de instrucciones
- 52 páginas
- 3.57 mb
Ir a la página of
manuales de instrucciones parecidos
-
Scanner
Metrologic Instruments MS7620
59 páginas 4.47 mb -
Scanner
Metrologic Instruments Voyager MS9500
2 páginas 0.31 mb -
Scanner
Metrologic Instruments MS6130 MX003
44 páginas 0.29 mb -
Scanner
Metrologic Instruments MS7100
45 páginas 1.24 mb -
Scanner
Metrologic Instruments IS4823
48 páginas 2.54 mb -
Scanner
Metrologic Instruments MS2320
1 páginas 0.08 mb -
Scanner
Metrologic Instruments MS951
77 páginas 0.2 mb -
Scanner
Metrologic Instruments MS7180
52 páginas 3.09 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Metrologic Instruments MS1690. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Metrologic Instruments MS1690 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Metrologic Instruments MS1690 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Metrologic Instruments MS1690, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Metrologic Instruments MS1690 debe contener:
- información acerca de las especificaciones técnicas del dispositivo Metrologic Instruments MS1690
- nombre de fabricante y año de fabricación del dispositivo Metrologic Instruments MS1690
- condiciones de uso, configuración y mantenimiento del dispositivo Metrologic Instruments MS1690
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Metrologic Instruments MS1690 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Metrologic Instruments MS1690 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Metrologic Instruments en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Metrologic Instruments MS1690, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Metrologic Instruments MS1690, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Metrologic Instruments MS1690. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
METROLOGIC INSTRUMENTS, INC. MS1690 Focus ™ Area Imaging Bar Code Scanner Inst allation and User ’ s Guide 00-02098_Cover_Quark_March_2005.qxd 3/11/2005 9:31 AM Page 1[...]
-
Página 2
Copyright © 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or b y any means without prior written consent, except by reviewer, who may quote br ief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentio ned in this doc[...]
-
Página 3
ii T ABLE OF C ONTENTS Introduction ............................................................................................................ 1 Scanner and Acce ssories .................................................................................. 2 Scanner Components ..........................................................................[...]
-
Página 4
iii T ABLE OF C ONTENTS Scanner and Cable T erminations Scanner Pinout Connecti ons .......................................................................... 34 Cable Connector C onfigurat ions .................................................................... 36 Limited Wa rranty .................................................................[...]
-
Página 5
1 I NTRODUCTION The MS1690 Focus is a high performa nce hand-held area i maging bar code scanner that utilizes high-resolution CMOS imaging sensor s for superior image quality. Focus utilized Omniplanar, Inc.’s S wiftdecoder™ software, for reliable decoding of both 1D and 2D bar code s ymbologies. Sharp images can be captured and transmitted in[...]
-
Página 6
2 I NTRODUCTION Scanner and Accessories B ASI C K IT Part # Description MS1690 Focus Area Imaging Bar Code Scanner 00-02544 MetroSelect ® Singl e-Line Configur ation Guide* 00-02065 Supplemental Configuration Guide * 00-02098 MS1690 Focus Area Imaging Bar Code Scanner Installation and User’s Guide* * Available on the Metrologic website - www.met[...]
-
Página 7
3 I NTRODUCTION Scanner and Accessories O PTIONAL A CCESSORIES Part # Description 53-53213x-N-3 USB Power/Communication Cable, 2.7 m (9 ft.) coiled cord, lo ng strain relief, black 53-53214x-N-3 USB Power/Communication Cable, 4.5 m (15 ft.) coiled cord, lo ng strain relief, black This cable is for use with full speed USB (-40) interface only. 53-53[...]
-
Página 8
4 I NTRODUCTION Scanner Components Figure 1. Scanner Components Item Description 1 Yellow LED See Visual Indicators (on page 17) 2 White LED See Visual Indicators (on page 17) 3 Blue LED See Visual Indicators (on page 17) 4 Speaker See Audible Indica tors (on page 16) 5 Trigger 6 Red Window LED Aperture 7 Cable Release See The PowerLink Cable (on p[...]
-
Página 9
5 I NTRODUCTION T HE P OWER L INK C AB L E C ONNECTING Important: If the PowerLink cable is not fully ‘latched’ the unit can power intermittently. Figure 2. Figure 3. D ISCONNECTING Before removing the cable from the scanner, Metrologic recommends that the power on the host system is off and the power supply has been disco nnected from the Powe[...]
-
Página 10
6 I NTRODUCTION Labels Each scanner has a label loc ated on the underside of the head. T his label provides the unit’s model number, date of manufacture, serial numb er, CE and caution information. The follo wing figur e gives an example of the label a nd its location. Figure 5. Label Samples and Location Maintenance Smudges and dirt can interfer[...]
-
Página 11
7 I NSTALLING THE S CANNER TO THE H OST S YSTEM RS232 MS1690-14 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the Focus. You will hear a ‘click’ when the connection is made. 3. Connect the 9-pin D-type connector of the communication cable to the proper COM port of the host device.[...]
-
Página 12
8 I NSTALLING THE S CANNER TO TH E H OST S YSTEM Keyboard Wedge MS1690-47 1. Turn off the host device. 2. Plug the 10-pin RJ45 male end of the PowerLink cable into 10-pi n socket on the Focus. You will hear a ‘click’ when the connection is made. 3. Disconnect the keyboard from the host device. 4. Connect the “Y” ends of the communication ca[...]
-
Página 13
9 I NSTALLING THE S CANNER TO TH E H OST S YSTEM Stand Alone Keyboard MS1690-47 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the Focus. You will hear a ‘click’ when the connection is made. 3. Plug the other end of the communication cable into the host’s keyboard po rt. 4. Plug [...]
-
Página 14
10 I NSTALLING THE S CANNER TO TH E H OST S YSTEM IBM MS1690-11 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the Focus. You will hear a ‘click’ when the connection is made. 3. Connect the other end of the MVC cable to the host device. 4. Turn on the host device. 5. Focus will start to [...]
-
Página 15
11 I NSTALLING THE S CANNER TO THE H OST S YSTEM Integrated USB: Full Speed MS1690-40 Low Speed MS1690-38 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB cable into the 10-pin socket on the Focus. You will hear a ‘click’ when the connection is made. 3. Plug the USB type A end of the USB cable into the host’s USB port.[...]
-
Página 16
12 S TAND K ITS S TAND C OMPONENTS , MLPN 46-00147 Figure 11. Stand Components Item Description Qty. a. Stand Base Qty. 1 b. Flexible Shaft Qty. 1 c. Flexible Shaft Cover Qty. 1 d. Scanner Cradle Qty. 1 e. ¼" – 20 x 3/8" Flat Head Phillips, 82° Undercut Qty. 2 f. #8 Round Head Wood Screw Qty. 2[...]
-
Página 17
13 S TAND K ITS H ARD M OUNTING THE S TAND (O PTIONAL ) Metrologic provides two #8 wood screws for securing the stand base to the counter top. The following figure provides the pilot hole dimensions for securing the stand base. Figure 12. Stand Base Hole Pattern (Not to Scale)[...]
-
Página 18
14 S TAND K ITS A SSEMBLING THE S TA N D Figure 13. Assembling the Stand[...]
-
Página 19
15 S CANNER O PERATION T WO D EFAULT M ODES OF O PERATION * CodeGate, Out of Stand 1. The IR detects an object in the IR activation range and automatically turns on linear illumination. 2. Aim the scanner’s line of light over the bar code. 3. Pull the trigger to initiate scanning. The scanner’s light output will start to flash as it attempts to[...]
-
Página 20
16 S CANNER O PERATION Audible Indicators When the Focus is in operation, it prov ides audi ble feedback. These sounds indicate the status of the scanner. Eight settings are availab le for the tone of the beep (normal, 6 alternate tones and no t one). T o change the tone, refer to the MetroSelect Single-Line Confi guration Guide, MLPN 00-02544 or M[...]
-
Página 21
17 S CANNER O PERATION Visual Indicators The MS1690 has three LED indic ators (yellow, white and blue) located on the top of the scanner. When the scanner is on, the flashing or stationary activity of the LEDs indicates the status of the current scan and the scanner. No LEDs are Illuminated The LEDs will not be illuminat ed if the scanner is not re[...]
-
Página 22
18 S CANNER O PERATION Failure Modes Long Razzberry Tone – During Power Up Failed to initialize or configure the sc anner. If the scanner does not respond after reprogramming, return the scanner for repair. Short Razzberry Tone – During Scanning An Invalid bar code has been scanne d when in configuration mode or th e trigger has been pulled too[...]
-
Página 23
19 S CANNER O PERATION Depth of Field by Minimum Bar Code Element Width Figure 16. Depth of Field by Minimum Bar Cod e Element Width M INIMUM B AR C ODE E LEMENT W IDTH 1D PDF A B C D E F G mm .132 .19 .254 .33 .533 .254 .381 mils 5.2 7.5 10.4 13 21 10 15.9 Specifications are subjec t to change without notice.[...]
-
Página 24
20 S CANNER O PERATION IR Activation Range The MS1690 has a built in obj ect detection sensor that instantly turns on the scanner when an object is presented with in the scanner’s IR activation Area. Figure 17. IR Activation Area Specifications are subjec t to change without notice .[...]
-
Página 25
21 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Met ro or 1- 800-436-3876 to preserve the lim ited warranty terms. All Interfaces MS1690 Series Troubleshooting Gui de Symptoms Possible Causes Solution No power is being supplied to the scanner. Check transformer, outlet a[...]
-
Página 26
22 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit powers up, but does not beep when bar code is scanned. The beeper is disabled and no tone is selected. Enable the beeper and select a tone. The unit powers up, but does not scan and/or beep. The bar code symbology tryi ng to be scanned is not enabled. UPC/EAN, Code 39, interleave[...]
-
Página 27
23 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The print quality of the bar code is suspect. Check print mode. The type of printer could be the problem. Change print settings (i.e. change to econo mode or high speed) . The aspect ratio of the bar code is out of tolerance. Check print mode. The type of printer could be the problem. Cha[...]
-
Página 28
24 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit is transmitting each character twi ce. The configuration is not set correctly. Increase interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings. Alpha characters show as lower case. The computer is in Caps Lock mo[...]
-
Página 29
25 D ESIGN S PECIFICATIONS MS1690 D ESIGN S PECIFICATIONS O PER AT IO NAL Light Source: LED 645 nm Pulse Duration: 1 ms to 8 ms Maximum Output of an Osram LED: Maximum 85 mA emits 3,120 mlm Depth of Scan Field: 0 mm – 230 mm (0" – 9") fo r 0.330 mm (13 mil) Bar Code at Default Setting 49 mm W x 19 mm H (1.9” W x 0. 8” H) at 20 mm [...]
-
Página 30
26 D ESIGN S PECIFICATIONS MS1690 D ESIGN S PECIFICATIONS E LECTRICAL Input Voltage: 5.0VDC ± 0.25V Peak = 2 W (Typical) Operating = 1.65 W (Typical) Power: Idle / Standby = 800 mW (Typical) Peak = 400 mA (Typical) Operation = 330 mA (Typical) Current: Idle / Standby = 160 mA (Typical) DC Transformer: Class 2; 5.2VDC @ 650 mA EMC: FCC, ICES-003 &a[...]
-
Página 31
27 A PPLICATIONS AND P ROTOCOLS The model number on each scann er includes the scanner number a nd factory default communications proto col. S CANNER V ERSION I DENTIFIER C OMMUNICATION P ROTOCOL ( S ) 11 IBM 468X/469X, RS232-TXD, RXD, RTS, CTS 14 RS232 (TX, RX, RTS, CTS, DTR) 38 Low Speed USB 40 Full-speed USB MS1690 - 47 Keyboard Wedge, Stand-Alo[...]
-
Página 32
28 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S Many functions of the scanner can be “confi g ured” – that is, enabled or disabled. The scanner is shipped from the fact or y programmed to a set of default conditions. The default param eter of the scanner has an asterisk (*) in the charts on the following pages. If an asterisk is not in [...]
-
Página 33
29 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S PARAMETER DEFAULT RS232 IBM 46XX KBW USB Maxicode 9 9 9 9 Aztec 9 9 9 9 Postals 9 9 9 9 Mod 43 Check on Code 39 9 9 9 9 MSI-Plessy 10/10 Check Digit 9 9 9 9 MSI-Plessy Mod 10 Check Digit * 9 9 9 9 Paraf Support ITF 9 9 9 9 ITF Symbol Lengths Variable 9 9 9 9 Symbol Length Lock None 9 9 9 9 Beepe[...]
-
Página 34
30 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S PARAMETER DEFAULT RS232 IBM 46XX KBW USB Transmit lead zero on UPC-E 9 9 9 9 Transmit UPC-A number system * 9 9 9 9 Transmit UPC-A Manufacturer ID# * 9 9 9 9 Transmit UPC-A Item ID# * 9 9 9 9 Transmit Codabar Start/Stop C haracters 9 9 9 9 CLSI Editing (Enabl e) 9 9 9 9 Transmit Mod 43 Check dig[...]
-
Página 35
31 D EFAULT S ETTINGS – C OMMUNICATION P ARAMETER S PARAMETER DEFAULT RS232 IBM 46XX KBW USB XON/XOFF Handshaking 9 ACK/NAK 9 Two Digit Supplements 9 9 9 9 Five Digit Supplements 9 9 9 9 Bookland 9 9 9 9 977 (2 digit) Supple mental Requirement 9 9 9 9 Supplements are not Required * 9 9 9 9 Two Digit Redundancy * 9 9 9 9 Five digit Redundancy 9 9 [...]
-
Página 36
32 C ONFIGURATION M ODES The MS1690 Focus Series has thr ee modes of configur ation. • Bar Codes The MS1690 can be configur ed by scanning the bar codes included in the Metrologic Single-Line Config uration Guide ( MLPN 00-02544 ). This manual can be downloaded for FREE from Metrologic’s website (www.metrologic.com). • MetroSet 2 This user-fr[...]
-
Página 37
33 U PGRADING THE F LASH ROM F IRMWARE The MetroSet2 program is a functional c omponent of Metrologic’s ne w line of Flash- based scanners. T his program allo ws the user of a Metrologic scanner to quickly upgrade to a ne w or custom version of firmware. It requires the use of a personal computer runnin g Windows 95 or greater and the use of a se[...]
-
Página 38
34 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections MS1690-14, RS232 Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input 7 Reserved 8 Reserved 9 +5VDC The MS1690 scanner interfaces terminate to a 10-pin, RJ45 Female Socket. The serial # label indic ates the interface enabled when the [...]
-
Página 39
35 S CANNER AND C ABLE T ERMINATIONS MS1690-38, Low Speed USB Pin Function 1 GND/USB- 2 Transmit 3 Receive 4 RTS Output 5 CTS Input 6 D+ 7 USB + V 8 D- 9 +5VDC 10 Shield Ground MS1690-40, Full Speed USB Pin Function 1 GND/USB- 2 Transmit 3 Receive 4 RTS Output 5 CTS Input 6 D+ 7 USB + V 8 D- 9 +5VDC 10 Shield Ground Figure 19.[...]
-
Página 40
36 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable 53-53000-3 Coiled Pin Function 1 Shield Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 DTR Input/Light Pen Source 5 Power/Signal Ground 6 Reserved 7 CTS Input 8 RTS Output 9 +5VDC Stand Alone Keyboard PowerLink Cable 53-53020-3 Pin [...]
-
Página 41
37 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configuration (Host End) Keyboard Wedge Po werLink Cable 53-53002-3 Coiled Pin Function 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Ground 5 +5 VDC Pin Function 1 PC Data 2 No Connect 3 Power Ground 4 +5 VDC 5 PC Clock 6 No Connect Metrologic will supply an adap ter cable with a 5-pin D[...]
-
Página 42
38 L IMITED W ARRANTY The MS1690 Focus ™ scanne rs are manufactured by Metrologic at its Bla ckwood, New Jersey, U .S.A. facility. The MS16 90 Focus scanners hav e a five (5) year limited warranty fro m the date o f manufacture. Metrologic warrants and repre sents that all MS1690 Fo cus scanners are free of al l defects in material, workmanship a[...]
-
Página 43
39 P RODUCT S AFETY Notices This equipment has been tested an d found to comply with limits for a Class A digital device, pursuant to par t 15 of t he FCC Rules. These limits are designed to provide reasonable protecti on agai nst harmful interfere nce when the equipment is operated in a commercial environme nt. This equipment generates uses, and c[...]
-
Página 44
40 P RODUCT S AFETY Caution Use of controls or adjustments or perfo rmance of procedures other than those specified herein may result in hazar dous radiation exposure . Under no circumstances should the customer attempt to service the L ED scanner. Never attempt to look at the LED beam, even if the scanner appears to be nonfunctional. Never open th[...]
-
Página 45
41 P ATENTS Worldwide Patents Pendin g[...]
-
Página 46
42 I NDEX A AC ..................................2, 7–11, 26 Accessories.................................... 2 Adapter ....................................2, 37 Aperture .........................................4 Audible Indicator ..............17–18, 33 B Bar Code ................... 21–24, 25, 32 Bar Code Element........................19 B[...]
-
Página 47
43 I NDEX M Maintenance ..................................6 Meteor ..........................................33 MetroSelect ......................16, 27, 32 MetroSet2 ....................................33 Mode of Operation ....................... 15 N Notices .........................................39 P Patent.....................................[...]
-
Página 48
44 N OTES[...]
-
Página 49
45 C ONTACT I NFORMATION AND O FFICE L OCATIONS C ORPORATE H EADQUA RTERS N ORTH A MERICA E UROPEAN , M IDDLE E AST & A FRICA N H EAD QUA RT ERS USA, New Jerse y Germany , Munich Metrologic Instruments, Inc. Metrologic Instruments GmbH Tel: 1-800-ID-METRO Fax : 856-228-6673 Tel: 49-89-89019-0 Fax: 49-89-8901 9-200 Email: info@metrologic.com Em [...]
-
Página 50
[...]
-
Página 51
[...]
-
Página 52