Metrologic Instruments MS6130 MX003 manual
- Consulta online o descarga el manual de instrucciones
- 44 páginas
- 0.29 mb
Ir a la página of
manuales de instrucciones parecidos
-
Scanner
Metrologic Instruments IS1650
2 páginas 0.28 mb -
Scanner
Metrologic Instruments MS6520 Series
44 páginas 6.76 mb -
Scanner
Metrologic Instruments MS2221 / MS2222
68 páginas 12.29 mb -
Scanner
Metrologic Instruments MS6130
45 páginas 0.33 mb -
Scanner
Metrologic Instruments MS6130 MX003
44 páginas 0.29 mb -
Scanner
Metrologic Instruments MS5100
40 páginas 1.25 mb -
Scanner
Metrologic Instruments MS2xxx Series
88 páginas 1.85 mb -
Scanner
Metrologic Instruments MLPN 2407
154 páginas 0.51 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Metrologic Instruments MS6130 MX003. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Metrologic Instruments MS6130 MX003 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Metrologic Instruments MS6130 MX003 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Metrologic Instruments MS6130 MX003, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Metrologic Instruments MS6130 MX003 debe contener:
- información acerca de las especificaciones técnicas del dispositivo Metrologic Instruments MS6130 MX003
- nombre de fabricante y año de fabricación del dispositivo Metrologic Instruments MS6130 MX003
- condiciones de uso, configuración y mantenimiento del dispositivo Metrologic Instruments MS6130 MX003
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Metrologic Instruments MS6130 MX003 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Metrologic Instruments MS6130 MX003 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Metrologic Instruments en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Metrologic Instruments MS6130 MX003, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Metrologic Instruments MS6130 MX003, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Metrologic Instruments MS6130 MX003. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
METROLOGIC INSTRUMENTS, INC. MS6130 Hand Held Laser Scanner and MX003 Scanner Interfaces Installation and User’s Guide[...]
-
Página 2
iii T ABLE OF C ONTENTS MS6130 Hand Held Bar Code Scanner ..................................................... 1 MX003 Series Scanner Interfaces ............................................................. 2 Unpacking List ......................................................................................... 3 Connections of the “MX” Inter[...]
-
Página 3
iv T ABLE OF C ONTENTS (C ONTINUED ) Maintenance .......................................................................................... 27 Troubleshooting ..................................................................................... 28 Appendix A Specifications ........................................................................... [...]
-
Página 4
Printer Note: Leave page blank .[...]
-
Página 5
1 T HE MS6130 H AND H ELD B AR C ODE S CANNER MS6130 Hand Held Bar Code Scanners are wireless scanners with a mobility range of up to 30 feet from the receiver. When not in use, the scanner rests in a universal-charging stand. The scanner will be fully charged in 2 hours when not scanning in the stand. A fully charged MS6130 can provide up to 8 hou[...]
-
Página 6
2 MX003 S ERIES S CANNER I NTERFACES Metrologic’s MX003 Series Scanner Interfaces provide a short range, one- way wireless data communication link between a remote portable scanner and an RS-232 or light pen host device. Specifically, Metrologic’s MS6130 Hand -Held Laser Scanners include a Liberty ® RF transmitter board . Metrologic’s MS700i[...]
-
Página 7
3 U NPACKING L IST Your shipment will contain a set of items from the two groups listed below: Transmitter Group: • MS6130 Hand-Held Scanner • Stand #45880 (optional) • Stand #45558, 45559 and 45560 (optional) • MS4120 Programming Guide Receiver Group: • “MX” Scanner Interface • MCA951 adapter or adapter cable (if required) • Regu[...]
-
Página 8
4 C ONNECTIONS OF THE “MX” I NTERFACE TO THE H OST D EVICE Except version 17 1. Turn off the host system. 2. Connect the MCA to the host device. Connect the “MX” interface to the MCA. 3. Check the AC input requirements of the trans former to make sure the voltage matches the AC outlet. The socket outlet should be near the equipment and easi[...]
-
Página 9
5 C ONNECTIONS OF THE K EYBOARD W EDGE “MX” I NTERFACE TO THE PC Version 17 only MX003 Scanner Interfaces with a suffix of “17" are Keyboard Wedge versions used to interface with a PC and keyboard. 1. Turn off the PC. 2. Plug the “MX” receiver adapter cable to the PC keyboard port. 3. Plug the keyboard into the “MX” receiver adap[...]
-
Página 10
6 C ONNECTIONS OF THE MS700 I /MS720 I WITH “MX” TO THE H OST D EVICE To avoid potential problems, do not power up the scanner until the communication cable is secured to the host . 1. Turn off the host system. 2. Connect the 25-pin D-type connector on the MS700i/MS720i scanner’s head cable to the communication cable. Connect the other end of[...]
-
Página 11
7 C ONFIGURATION OF THE MS700 I /MS720 I WITH “MX” To perform matching procedure refer to page 18. Once the transmitter is assigned an ID number, configure the S700i/MS720i to accept RF communication. Although the changes made in this section effect the receiver, the MS6130 performs all scanning. 1. Scan the following bar code to enter the rece[...]
-
Página 12
8 C ONFIGURATION OF THE MS700 I /MS720 I WITH “MX” TO THE H OST S YSTEM To perform matching procedure refer to page 18. Before the MS700i/MS720i scanner ships from the factory, the factory programs the scanner to a group of default settings noted in the ScanSelect™ Scanner Programming Guide. An asterisk marks each default setting. The asteris[...]
-
Página 13
9 C ONFIGURATION OF THE “MX” TO THE S CAN P AL ® D ATA C OLLECTOR To perform matching procedure refer to page 18. The RS-232 parameters marked with an asterisk ( * ) in the charts are the default settings of the “MX”. The charts are in the Default Settings of the MS6130 and “MX” Receiver section of this guide. To communicate with each [...]
-
Página 14
10 C ONFIGURATION OF THE “MX ” TO THE RS-232, L IGHT P EN OR K EYBOARD W EDGE H OST S YSTEM To perform matching procedure refer to page 18. The light pen, RS-232 and Keyboard Wedge parameters marked with an asterisk ( * ) in the charts are the default settings of the “MX”. The charts are in the Default Settings of the Transmitter and “MX?[...]
-
Página 15
11 K EYBOARD W EDGE (KB) I NTERFACE Scan the ENABLE KB WEDGE INTERFACE bar code if your communication requirement is keyboard emulation. The scanner will provide keyboard emulation by converting the scanned bar code data to the PC keyboard scan code equivalent. Enable Keyboard Wedge Interface R 2 4 KB Parameter - Keyboard Type The following bar cod[...]
-
Página 16
12 K EYBOARD W EDGE (KB) I NTERFACE (C ONTINUED ) KB Parameter – Keyboard Type The following bar codes are used to define the keyboard country type. If necessary, scan the appropriate bar code. ** USA Keyboard B R 8 UK Keyboard B R 2 France Keyboard B R 3 Germany Keyboard B R 4 Italy Keyboard B R 5 Spain Keyboard B R 6 Belgium Keyboard B R 1 IBM [...]
-
Página 17
13 K EYBOARD W EDGE (KB) I NTERFACE (C ONTINUED ) Reserved B R B Reserved B R C Reserved B R D Reserved B R E Reserved B R F KB Parameter - Caps Lock Mode When Caps Lock is used on the keyboard, choose ENABLE CAPS LOCK. Once enabled, the scanner will simulate Caps Lock keyboard input. This mode will not work with all keyboard types. Enable Caps Loc[...]
-
Página 18
14 K EYBOARD W EDGE (KB) I NTERFACE (C ONTINUED ) KB Parameter - Alt Mode When this option is enabled, the scanner will duplicate this keyboard sequence: Hold down the Alt key; type the decimal number that corresponds to the appropriate keyboard character. Caution should be observed when using Alt mode because a scanner to host application conflict[...]
-
Página 19
15 C ONFIGURATION OF THE MS6130 H AND -H ELD To perform matching procedure refer to page 18. Before the MS6130 scanner ships from the factory, the factory programs the scanners to a set of default settings. These default settings can be found in the MS4120 Programming Guide. The default settings have an asterisk that appears before the brief defini[...]
-
Página 20
16 E NABLING THE MS700 I /MS720 I S CANNER ’ S RF L OW S PEED O PTION Before beginning this procedure, perform all steps in the sections, Matching the Transmitter to the Receiver and Configuration of the MS700i/MS720i with “MX” . Use the MS700i/MS720i scanner to scan the following bar codes. 1. Temporarily cover the bar code below Step 3. Sca[...]
-
Página 21
17 C HANGING THE ID In order for the MS6130 to send data to the correct receiver, they must have a matching ID number. The ID number is the serial number of the receiver. When the matching procedure is completed, the receiver will accept data only from a MS6130 that has the matching ID number. Each receiver is programmed with its serial number befo[...]
-
Página 22
18 M ATCHING P ROCEDURE With the MS6130, scan the following bar codes starting from the top down: Transmitter Enter/Exit Program Mode * * Recall Defaults D F 1 Enable RF Communications R 3 5 Transmitter Enter/Exit Program Mode * * Locate the model label on the case of the receiver. Scan the serial number bar code. The receiver and MS6130 are now ma[...]
-
Página 23
19 P ARTS OF THE MS6130 H AND -H ELD B AR C ODE S CANNER Becoming familiar with the features of the MS6130 hand-held scanner will help when operating one of these scanners. The illustration and list explain the pertinent parts. Figure 4: Scanner Parts Battery Charge Contacts Receptacle for the battery charger. Reactivation Switch Turns the unit on [...]
-
Página 24
20 C OMPONENTS OF THE MS6130 S ERIES S TAND The following are the components used to build the MS6130 series stand (MLPN: 45880). 1. Cradle 2. Stand Charger Pack 3. Pole Cover 4. Flex pole 5. Stand Base Cover 6. Stand Base 7. Charger Transformer 8. Charger Pack Screws 9. Mounting Screws 10. Lock Washer 6 1 3 4 5 10 9 7 8 2 CABLE CONNECTS THROUGH OP[...]
-
Página 25
21 I NSTALLATION OF THE MS6130 S ERIES S TAND Refer to for numbered components on the previous page 1. Use the stand base (6) as a template to drill and mount the base to the counter using the mounting screws (9) provided. 2. Feed the wire from the transformer (7) through the slot in the base cover (5) approximately 9" of the wire. 3. Press th[...]
-
Página 26
22 I NSTALLATION OF THE 6000 S ERIES U NIVERSAL C HARGING S TAND MLPN: 45558 - 115V, 45559 - 230V and 45560 - 240V (UK) Figure 6: Universal Charging Stand P ERMANENT C OUNTER T OP I NSTALLATION 1. Separate weighted base from rotating base by removing the (4) four screws. 2. Use the rotating base as a drill template. 3. Use the (4) four wood screws [...]
-
Página 27
23 N I C D B ATTERY C HARGER WITH R ECONDITIONING F EATURE MLPN: 45561 - 115V and 45562 - 230V How to Recondition 1. Place the scanner into the charge stand. 2. Push the stand tilt cup in the extreme down position to expose the hole for the discharge cycle switch. 3. Use a pin to push the discharge cycle switch located beneath the hole. 4. When the[...]
-
Página 28
24 V ISUAL I NDICATORS The scanner has red and green LEDs. When the scanner is on, the LEDs indicate the status of the scan and scanner. No Red or Green The scanner will turn off if the scanner has been dormant for a specified time. To reactivate the unit, direct the output window up then down toward the bar coded product. If the unit has been dorm[...]
-
Página 29
25 A UDIBLE I NDICATORS When the scanner and “MX” receiver are in operation, they provide audible indications. These sounds indicate the status of the scan and scanner. One Beep When the “MX” Receiver first receives power, the unit will beep once. If the scanner successfully reads a bar code, the green light will flash. If the “MX” rece[...]
-
Página 30
26 A UDIBLE I NDICATORS (C ONTINUED ) The “MX” receiver can be programmed to emit three beeps when the timeout occurs during communication between the host and receiver. Refer to the MS4120 Programming Guide section, Audible Indicators for Communication Timeouts to program this feature. There are four settings available for the tone of the beep[...]
-
Página 31
27 L ABELS The MS6130 scanner is either a CDRH Class II laser system or an IEC Class 1 Laser System. Your unit will have a CDRH Class II caution label or LASERKLASSE 1 label affixed below the model number label. The model number/avoid exposure label is located on the bottom of the scanner’s head. The following are examples of these labels: M AINT[...]
-
Página 32
28 T ROUBLESHOOTING 1. The receiver can receive data from a MS6130 with its own ID or 10 zeroes. It’s own ID can be received all the time. When using 10 zeroes, the first scan the receiver gets must have 10 zeroes as its ID and from that point on the receiver will accept both ID’s. Power down the receiver. Using the MS6130, scan the bar codes f[...]
-
Página 33
29 A PPENDIX A Specifications RF Link Characteristics Frequencies: One of the following depending on the country of operation: 418MHz 434MHz 912MHz Bandwidth: 220kHz Modulation: FM Certification: No FCC licensing required RF Protocol: One way data transmission Transmission time at a maximum of 100 ms 50K baud data rate Dedicated transmitter(s) to r[...]
-
Página 34
30 A PPENDIX A (C ONTINUED ) MX003 Series Scanner Interface Specifications FCC ID: LW5003 Operating Voltage: 5Vdc Antenna: Integral Dimensions: 3.54" x 1.97" x 0 .94" Weight: 0.175 lb. UL Listed: US and Canada Model Number Operating Frequency Data Interface RS-232 Light Pen Data Interface Keyboard Wedge MX003 912 MHZ 3 MX003-17 912 M[...]
-
Página 35
31 A PPENDIX A (C ONTINUED ) Specifications of Battery Pack Battery Type: “AA” NiCd Rechargeable Configuration: 3 Batteries/Pack Nominal Voltage: 3.6 VDC Maximum Voltage: 4.8 VDC Capacity: 600 mA Charge Cycles: Over 500 Full Charge/Discharge Charge Time: 4 Hours Short Circuit Protection: Auto/Reset Fuse 1.7A Hold Current Temperature Characteris[...]
-
Página 36
32 A PPENDIX B Default Settings of the MS6130 and “MX” Receiver Before the MS6130 hand-held scanner and “MX” Receiver ships from the factory, the factory programs the scanners to a group of default settings. An asterisk ( * ) in the charts on the following pages marks the default settings of the units. If an asterisk is not in the default c[...]
-
Página 37
33 A PPENDIX B (C ONTINUED ) Parameter T - Transmitter R - Receiver Default RS-232 Light Pen Long Range Activation in the Stand T * 3 3 Normal Scan T * 3 3 Pulsing Scan T 3 3 Custom Scan T 3 3 Green LED Rescan Indicator T 3 3 Short Same Symbol Rescan T 3 3 Long Same Symbol Rescan T * 3 3 Alternate Beeper Tone 1 R 3 3 Alternate Beeper Tone 2 R * 3 3[...]
-
Página 38
34 A PPENDIX B (C ONTINUED ) Parameter T - Transmitter R - Receiver Default RS-232 Light Pen DTR Input R 3 Carriage Return R * 3 Line Feed R * 3 ETX Suffix R 3 Tab Prefix R 3 Tab Suffix R 3 Prefix ID for UPC/EAN R 3 Suffix ID for UPC/EAN R 3 Bars High R * 3 Spaces High R 3 Transmit as Scanned R * 3 Transmit as Code 39 R 3 Poll Light Pen 5 Volts R 3[...]
-
Página 39
35 A PPENDIX B (C ONTINUED ) PARAMETER T - TRANSMITTER R - RECEIVER DEFAULT KEYBOARD WEDGE Keyboard Type R 3 AT R * 3 XT R 3 PS2 R 3 Keyboard Country Type R 3 USA R * 3 UK R 3 France R 3 Germany R 3 Italy R 3 Spain R 3 Belgium R 3 KB4700 R 3 Swiss R 3 Caps Lock R 3 Autodetection R 3 User Defined R 3 Transmit Cleanup Bit R 3 Transmit Alt Mode R 3 Tr[...]
-
Página 40
36 A PPENDIX C MX003 Series Scanner Interface Pin Assignments The interfaces are equipped with a shielded, 10-pin modular jack manufactured by Steward Stamping. The mating connector is a Steward Stamping shielded plug #937-SP-361010. Caution should be used when working with cables for this port because there is typically power present for scanner i[...]
-
Página 41
38 A PPENDIX E Notices Notice - applicable to 912 MHZ devices only This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any una[...]
-
Página 42
39 A PPENDIX F Patents “Patent Information This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No. 4,930,848 ; 4,958,984; 5,081,342; 5,260,553; 5,340,971; 5,340,973; 5,424,525; 5,468,951; 5,484,992; 5,525,789; 5,528,024; 5,591,953; 5,616,908; 5,627,359; 5,661,292; 5,777,315; 5,789,730; 5,789,731; 5,808[...]
-
Página 43
40 I NDEX A AC 4, 6 Adapter 3 Asia ii Audible indicators 25, 26 B Battery pack 31 Beep(s) 1, 2, 6, 7, 9, 10, 16 17, 19, 23, 25, 26, 28 C Cable 3, 6 Changing ID 17 Clean 27 Clean-up bit 14 Compliance 4, 6, 31 Configuration(s) 7-10, 15, 16, 28 Connections 4, 6 Copyright ii Current 29 Customer Service ii D Default settings 32-35 Dimensions 29 Disclaim[...]
-
Página 44
41 I NDEX (C ONTINUED ) R Receiver board 2 Red LED 1, 19, 24, 25 Rights property 40 RS-232 9, 10, 28 S ScanPal ® 2, 3, 9 ScanSelect 3, 8, 32 Shipping carton 3 South America ii Specifications 29-31 Stand 3, 20-23 T Temperature 31 Tones 26 Transformer 4, 6, 20, 21 Transmitter 1-3, 7, 10, 15, 16, 18, 29, 32-35 Troubleshooting 28 U Unpacking list 3 US[...]