Mitsubishi Electronics PAC-YG63MCA manual
- Consulta online o descarga el manual de instrucciones
- 16 páginas
- 0.28 mb
Ir a la página of
manuales de instrucciones parecidos
-
Air Conditioner
Mitsubishi Electronics MFZ-KJ35VE
12 páginas 2.73 mb -
Air Conditioner
Mitsubishi Electronics LGH-15RX4-E
4 páginas 1.45 mb -
Air Conditioner
Mitsubishi Electronics PKA-A30KA4.TH
32 páginas 3.12 mb -
Air Conditioner
Mitsubishi Electronics PUY-A42NHA2
120 páginas 10.58 mb -
Air Conditioner
Mitsubishi Electronics PMFY-P08NBMU-E1
36 páginas 2.24 mb -
Air Conditioner
Mitsubishi Electronics MSY18NA
32 páginas 2.49 mb -
Air Conditioner
Mitsubishi Electronics PEFY-AF1200CFM
24 páginas 0.65 mb -
Air Conditioner
Mitsubishi Electronics PUY-A24NHA4
3 páginas 1.95 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Mitsubishi Electronics PAC-YG63MCA. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Mitsubishi Electronics PAC-YG63MCA o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Mitsubishi Electronics PAC-YG63MCA se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Mitsubishi Electronics PAC-YG63MCA, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Mitsubishi Electronics PAC-YG63MCA debe contener:
- información acerca de las especificaciones técnicas del dispositivo Mitsubishi Electronics PAC-YG63MCA
- nombre de fabricante y año de fabricación del dispositivo Mitsubishi Electronics PAC-YG63MCA
- condiciones de uso, configuración y mantenimiento del dispositivo Mitsubishi Electronics PAC-YG63MCA
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Mitsubishi Electronics PAC-YG63MCA no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Mitsubishi Electronics PAC-YG63MCA y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Mitsubishi Electronics en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Mitsubishi Electronics PAC-YG63MCA, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Mitsubishi Electronics PAC-YG63MCA, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Mitsubishi Electronics PAC-YG63MCA. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
Mitsubishi Electric Air Conditioner Network System AI controller PAC-YG63MCA Installation/Instruction Manual Before using the device, carefully read this installation/instruction manual to ensure proper operation. Keep this manual for future reference and give it to the technician when the device is reinstalled or repaired. GB Table of Contents Pag[...]
-
Página 2
1 • Thoroughly read the following safety precautions before use. • Hazards that can occur from incorrect h andling are classified by the symbols below: • After reading this manual, keep this manual for future reference. When the dev ice is reinstalled or repaired, give this manual to those who provide these servic es. When the user changes, m[...]
-
Página 3
2 The AI controller measures temperature and humidity; it also has an alarm cap ability if the measurement data exceeds defined setpoints. Historical measurem ent data can be displayed via only th e G(B)-50A Web browser and TG-2000A. Temperature and humidity cannot be displayed on the G-50A LCD. Furthermore, an alarm can be output if measurement da[...]
-
Página 4
3 4-2. External Dimensions [ 24 VDC Power Supply] N623 Al controller PAC-YG63MCA MODEL SERVICE REF. PAC- INPUT WEIGHT SERIAL No. MADE IN JAPAN YG60MCA-J VOLTAGE DC24V;0.2A 0.6 kg / 1 / 3 8 lb Al controller PAC-YG63MCA [ Output LEDs ] Alarm Alarm Ch2 Ch1 [ OUTPUT ] Non-voltage Contact Output Alarm Alarm Ch2 Ch1 [ INPUT ] Pt100 4 to 20 mA / 1 to 5 V [...]
-
Página 5
4 6-1. Parts Purchased Separately Prepare the following parts to install this device. [Parts to be Purchased Separately] [Commercially available parts] 6 Installation Required Part Specification Unit fixing screws M4 screw × 4 (* M4: ISO metric screw thread) Power supply for this device Commercially available power source : 24 VDC±10% 0.2 A (Mini[...]
-
Página 6
5 6-2. Installation Instructions The AI controller PAC-YG63MCA does not have a waterproof structure. Be sure to install the AI controller insi de a control panel that is located indoors. Prepare a control panel capable of storing this device such as the one shown in t he figure. (Install the device in a control panel strong enough to withstand a we[...]
-
Página 7
6 (3) Refer to "7. Wiring Instructions" and co nnect the wires for the power line, M-NET transmission line , output signal lines, an d sensor input signal lines. 7-1. Terminal Diagram PAC - SC50KUA M-NET N FG L -V +V Diagram Image (Installed within a Control Panel) * The wiring in the diagram has been simplified. M-NET Sensor input signal[...]
-
Página 8
7 7-2. Connecting the Power and M-NET Transmission Lines S FG M- NET S / B / A (M1) (M2) U U R V+/V -/FG CN02 A /B/S Tightening torque for terminal screws: 1 N·m Connect the M-NET transmission line of this device to a power supply unit (PAC-SC50KUA) for the M-NET transmission line or an outdoor unit (either a c entralized control line or indoor co[...]
-
Página 9
8 7-3. Connecting the Sensors • For channel 1, select one of the followin g four types: Pt100 detection, 4 to 20 mADC, 1 to 5 VDC, or 0 to 10 VDC analog input. • For channel 2, select one of the fo llowing three types: 4 to 20 mADC, 1 to 5 VDC, or 0 to 10 VDC analog input. • The wire length depends on the specific ations of the sensor. Howeve[...]
-
Página 10
9 7-4. Connecting Alarm Setpoint Outputs The maximum wire length is 100 m. Howe ver, since the use of long wires make s the device susceptible to noise, using wires no more than 10 m long is recommended. To use these, various settin gs need to be configured. Re fer to "8. Initial Settings". (Non-valtage Contacts) CN03 Ch1 Ch2 X1 Caution: [...]
-
Página 11
10 After completing the procedures described in "6. Installation" and "7. Wiring Inst ructions", set the initial settings in accordance with the procedure described below. (1) M-NET address settings (2) Use the dip switches to select functions. Select the function required for each input/output chann el to be used. The switch as[...]
-
Página 12
11 (3) Turn on the power of this device. Verify that the LED16 (CPU power on) and LED17 (M-NET power on) are lit. (4) Set the time. Set the current time from a sys tem controller (G(B)-50A, TG-2 000A) or a Maintenance Tool. (5) Configure the settings of the system controller (G(B)-50A or TG-2000A). Configure settings for the system controller (G(B)[...]
-
Página 13
12 Set the dip switches for function selectio n according to the system to be used. At factory default, the SW01, SW02, SW03, SW08, and SW 09 dipswitches are all set to OFF; the SW11 and SW12 dipswitches are both set to ON, and the M-NET address is set to 01. Be sure to turn off the power before changing switch settings. 9 Dip Switch Functions SW S[...]
-
Página 14
13 The LEDs of this device indicate the upper/lower limit al arm interlock output status and error status of this device. 10-1.Alarm Setpoint Output and Error Displays *1: When a sensor error or communication erro r occurs, the error status is displayed. 10-2.Sensor and Communication Error Displays If a sensor error or communication error occurs, a[...]
-
Página 15
14 Use the following procedure to c onfirm operation of the system. (1) Configure the settings of this de vice and the system controller while referring to "8. Initial Settings". (2) Confirm whether the measurement values of channel 1 and channel 2 are displayed on th e system controller properly. * Depending on the conditions, compare th[...]
-
Página 16
WT04975X02 Printed in Japan This product is designed and in tended for use in the residential, commercial and light-industrial environment. This product at hand is based on the following EU regulations: • Low Voltage Directive 2006/95/EC • Electromagnetic Compatibility Directive 2004/108/EC NOTE: This equipment has been tested and found to comp[...]