MRV Communications AE182FCAHA manual
- Consulta online o descarga el manual de instrucciones
- 33 páginas
- 2.15 mb
Ir a la página of
manuales de instrucciones parecidos
-
Network Card
MRV Communications TS700/155
77 páginas 1.13 mb -
Network Card
MRV Communications EM316T1
23 páginas 0.52 mb -
Stereo Amplifier
MRV Communications EM316EDFA-LPR
44 páginas 0.6 mb -
Network Card
MRV Communications EM316E3SF
19 páginas 0.37 mb -
Drill
MRV Communications AE182FCAHA
33 páginas 2.15 mb -
Server
MRV Communications LX-4000 Series
65 páginas 1.49 mb -
Switch
MRV Communications EM316SW-XY
76 páginas 0.88 mb -
Network Card
MRV Communications TS800/155
77 páginas 1.13 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones MRV Communications AE182FCAHA. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica MRV Communications AE182FCAHA o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual MRV Communications AE182FCAHA se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales MRV Communications AE182FCAHA, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones MRV Communications AE182FCAHA debe contener:
- información acerca de las especificaciones técnicas del dispositivo MRV Communications AE182FCAHA
- nombre de fabricante y año de fabricación del dispositivo MRV Communications AE182FCAHA
- condiciones de uso, configuración y mantenimiento del dispositivo MRV Communications AE182FCAHA
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de MRV Communications AE182FCAHA no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de MRV Communications AE182FCAHA y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico MRV Communications en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de MRV Communications AE182FCAHA, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo MRV Communications AE182FCAHA, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual MRV Communications AE182FCAHA. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
AE092FCAHA AE182FCAHA 0010570925 A Household MR V Ceiling Concealed T ype Room Air Conditioner[...]
-
Página 2
1[...]
-
Página 3
2[...]
-
Página 4
3 AE092FCAHA AE182FCAHA[...]
-
Página 5
Heating operation indication For adjusting the clock and time for timer operation. Note: This model of air conditioner doesnt provide the air sending direction adjustment function and thus the "LOU" key is disengaged while the automatic air direction indication may be displayed. This remote controller hasn't electric-aided heating in[...]
-
Página 6
Important Points of Safety The following four important points of safety and suggestions should be paid great attention: W arning: Misuse may cause fatal result such as death or serious injury etc. Attention: Misuse may cause human injury or damage of machine, in some case fatal results. : Content marked with this ìforbiddenî sign should be absol[...]
-
Página 7
Important Points of Safety W arning l Avoid your body being blown directly by cold wind for long period, otherwise your health may be affected. l Donít extend your fingers or any other article into the inlet or outlet during operation of the machine for touching re- volving fans may cause human injury or damage of machine. l If something abnormal [...]
-
Página 8
Important Points of Safety Attention Attention points for use * Ensure ventilation of the room if the machine is used with burning facilities. Deficient ventilation can cause oxygen shortage. * Check whether installation bench of the machine is damaged after a long period of use. Machine on damaged bench may fall down and cause human injury or othe[...]
-
Página 9
AUTO, F AN operation Operating instructions 2 1 3 4 Unit start Press the "ON/OFF" key to turn on the unit. The LCD on the remote controller displays the previous operating conditions (excluding previous timer , sleep and louver conditions). The remote controller operation indicator turns on. AM R 2 1 4 3 Select operation mode Press the &q[...]
-
Página 10
2 3 1 4 5 R 3 1 2 4 5 Operating instructions COOL, DR Y , HEA T operation Recommended operation mode: Please use cooling mode in summer and heating mode in winter. Please use DRY mode in spring or autumn humid climate. Unit start Press the "ON/OFF" key to turn on the unit. The LCD on the remote controller displays the prev- ious operating[...]
-
Página 11
4 4. Confirm the setting 12:00 12:00 AM 12:00 12:00 Operating instructions TIMER ON/OFF function Please adjust the clock before using timer function. Y ou may set the air conditioner automatically turn on or turn off when you wake in the early morning, come off work or after you fall asleep. R 1 4 2 3 1. Set the operation mode after the unit is tur[...]
-
Página 12
12:00 12:00 12:00 12:00 * * R 1 4 2 6 3 5 TIMER ON-OFF operation Operating instructions 1. After unit starts, select your desired operation mode . The operation indicator turns on and the operation mode is displayed on the LCD screen. 2. Timer mode selection AM TIMER ON TIMER OFF TIMER ON BLANK TIMER OFF AM TIMER ON TIMER OFF TIMER ON-OFF AM AM Sel[...]
-
Página 13
Operating instructions SLEEP function Using SLEEP function Before using this function, the time must be checked and set. After the unit starts , set the operation status , then press "SLEEP " key. Before going to bed , you can press the "SLEEP " key on the remote controller and the air condit- ioner will operate in comfortable S[...]
-
Página 14
T roubleshooting The following cases are not troubles. During operation , the air conditioner may sometimes exhibit a sound of "clatter " or "rumble " . This is the common sound of refrigerant flow but not a trouble. A sound of "Pi-Pa " is generated. Smells are given off. During operation , mist or steam are blown out.[...]
-
Página 15
T roubleshooting ON OFF During DRY operation, there is no air sent out or fan speed cant be changed. In HEAT mode , the outdoor unit generates water or steam. This occurs during removal of the frost (in defrosting operation) on the radiator of outdoor unit. Defrost operation In HEAT mode , the indoor fan still keeps running even the unit operation [...]
-
Página 16
When fault occurs Poor cooling or heating Is the operation controller adjusted as required? Are there any obstructs before the air inlet or outlet? Is there any door or window left open? Poor cooling Is there any other heat source in the room? Is there any direct sunlight into the room? Are there too many people in the room? If , after the above ch[...]
-
Página 17
Notice to users Notice to users l To ensure proper operation of the system , the user shall follow this instruction manual to install the unit. l When handling the air conditioner , please be care not to scratch the case surface. l This instruction manual describes the installation method aided with the installation tools specified by Qingdao Haier[...]
-
Página 18
Installation precautions 17 W arning ! Before installing, do read this "Safety precautions" carefully to guarantee the proper installation. The below attentive matters are divided into" W arning " and " Note" two parts. When the wrong installation occur , it is very possible death and severe injury and other serious ac[...]
-
Página 19
Installation precautions This description does not address to all possible cases. For new requirement and query, please consult the regional sales center of Haier Air Conditioner General Co., Ltd. This instruction manual must be read carefully before beginning of installation, improper ins- tallation may cause accidents and thus bring about machine[...]
-
Página 20
l The power supply shall be connected from the outdoor side. (For models with electric-aided heating function, the power supply to the indoor unit shall be connected at the indoor side The power cord size is 3 x (1.25-1.5)mm 2 , type of YZW). l A separate power circuit shall be supplied and connected by a qualified electrician according to the wiri[...]
-
Página 21
Installation procedure Fig 1 Choosing the installation location Please do not install the unit in places where flammable gases may be leaked. In case that gas is leaked and accumulated around the unit, it may cause dangers of fire etc. The indoor unit shall be installed at locations where cold and hot air could evenly circulated. The following loca[...]
-
Página 22
1 100 223 Installation procedure Fig 2 AE182FCAHA AE092FCAHA Installation of indoor unit l The unit shall be installed according to the specifications to resist to strong wind and earthquake. Improper installation may cause dangers of unit falling down etc. After selecting the unit installation location, proceed the following steps: 1. Drill a hole[...]
-
Página 23
Installation procedure Installation of indoor unit l When installing the cassette hind type indoor unit, a specially designed return air bellows shall be installed, as shown in Figure 3, Figure 4. l The distance between the air duct outlet and the air conditioner air outlet shall not exceed 0.5 m. 22 A *0.5m Installing building roof Ceiling Air sup[...]
-
Página 24
Installation procedure Installation of indoor unit Installing the suspension screw: Use M8 or M10 suspension screws (4, prepared in the field) (when the suspension screw height exceeds 0.9 m, M10 size is the only choice). These screws shall be installed as follows with space adapting to air conditioner overall dimensions according to the original b[...]
-
Página 25
Installation procedure Installation of remote controller Installation of the remote controller 1. Remove the back cover of the remote controller Firstly detach the remote controller back cover at the bottom, then detach at the top. The whole back cover of the remote controller could be removed. Remote controller bottom Remote controller back cover [...]
-
Página 26
25 Installation procedure Drain pipe ! Caution l In order to drain water normally, the drain pipe shall be processed as specified in the installation manual and shall be thermal insulated to avoid dew generation. Improper hose connection may cause indoor water leakage. Requirements l The indoor drain pipe shall be thermal insulated. l The connectio[...]
-
Página 27
Installation procedure R efrigerant piping l In installation, if there is refrigerant gas leakage, please take ventilation measures immediately. The refrigerant gas will generate poisonous gas upon contacting fire. l After installation, please verify that there is no refrigerant leakage. The leaked re- frigerant gas will produce poisonous gas when [...]
-
Página 28
Installation procedure R efrigerant piping V acuum pumping W ith a vacuum pump, create vacuum from the stop valve of the outdoor unit. l Emptying with refrigerant sealed in the outdoor unit is absolutely forbidden. Open all valves Open all the valves on the outdoor unit. Gas leakage detection Check with a leakage detector or soap water that if ther[...]
-
Página 29
Installation procedure CElectric wiring ! Warning l The electric wiring work shall be conducted by qualified electricians according to the install- ation instructions. A separate power circuit shall be used. Insufficient power cord amperage or improper wiring will cause danger of electric shock or fire. l During wiring connection, the power cord sh[...]
-
Página 30
Installation procedure Electric wiring Wiring connection method : (the wiring diagram is attached inside the machine) 1) Ring terminal connection method Connection method f or ring terminal If there is a ring at the end of the connection wire, the wire connection method is as shown in the right figure. Remove the terminal screw and insert it throug[...]
-
Página 31
Installation procedure Field setting Field setting Field setting the unit number In order to realize central control of the MRV air conditioning system, its necessary to set the indoor unit number (control address). Indoor unit number setting Indoor unit number setting switch and confirmation of the settings. There is a 4-position dial switch for s[...]
-
Página 32
List of troubles List of displayed troubles on the remote controller T rouble description Ambient temperature sensor fault Indoor unit gas pipe temperature sensor abnormal Indoor unit and outdoor unit signal transmission abnormal Faulty communication between indoor unit 846 chip and 808 chip Indoor unit liquid pipe temperature sensor trouble Indoor[...]
-
Página 33
Installation check and trial operation Check if the drain pipe and connection wires are arranged properly. The drain pipe shall be put below. The connection wire shall be put above. Be sure to wrap the drain pipe (especially the indoor part and the part inside the machine) with thermal ins- ulating materials. The drain pipe shall be made into slope[...]