Napco Security Technologies XP-400 manual
- Consulta online o descarga el manual de instrucciones
- 16 páginas
- 0.11 mb
Ir a la página of
manuales de instrucciones parecidos
-
Home Security System
Napco Security Technologies GEM-K1CA
40 páginas 0.49 mb -
Home Security System
Napco Security Technologies F-TPG
28 páginas 1.19 mb -
Home Security System
Napco Security Technologies 825
15 páginas 0.18 mb -
Home Security System
Napco Security Technologies GEM-P3200
68 páginas 2.53 mb -
Home Security System
Napco Security Technologies 1010
16 páginas 1.41 mb -
Home Security System
Napco Security Technologies MA3000
4 páginas 0.09 mb -
Home Security System
Napco Security Technologies GEM-X255
40 páginas 0.29 mb -
Home Security System
Napco Security Technologies GEM-K4
32 páginas 0.36 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Napco Security Technologies XP-400. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Napco Security Technologies XP-400 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Napco Security Technologies XP-400 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Napco Security Technologies XP-400, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Napco Security Technologies XP-400 debe contener:
- información acerca de las especificaciones técnicas del dispositivo Napco Security Technologies XP-400
- nombre de fabricante y año de fabricación del dispositivo Napco Security Technologies XP-400
- condiciones de uso, configuración y mantenimiento del dispositivo Napco Security Technologies XP-400
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Napco Security Technologies XP-400 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Napco Security Technologies XP-400 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Napco Security Technologies en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Napco Security Technologies XP-400, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Napco Security Technologies XP-400, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Napco Security Technologies XP-400. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
Usin g Y our XP-400 Security Sy stem NAPCO Oi220a page 1 Tuesday, September 16, 1997 08:30[...]
-
Página 2
2 Oi220a page 2 Tuesday, September 16, 1997 08:30[...]
-
Página 3
Introduction Congratulations on y our purc hase of an advanced NAPCO EXPRESS XP- 400 Security Sy stem. Meticulous ly developed by a leading manufac turer of state- of-the-art s ecurity products, this s y stem w ill provide y ou w ith unprecedented peace-of- mind & incorporates some of the most s ophisticated features available today . Above all[...]
-
Página 4
4 1 Bell / Battery Test Test y our bell or siren by pressing followed by . This will caus e the bell, or siren to sound f or 2 seconds and also initiate a test of the battery . 2 Central Station Communication Test (This test should only be perform ed on weekends or at a time designated by y our alarm com pany) 1. Notify Central Station of the im pe[...]
-
Página 5
Key pad Controls and Indi cator s Ready Light will light when all z ones are sec ure and system is r eady to be Armed. Zone Lights ( 1 through 4) will light to indicate that the corres ponding Zone is open, and will flash to indic ate a z one in alarm . A rmed Light will light when sy stem is Arm ed, and will flash when system is in Alarm Key -[...]
-
Página 6
A rming Your Sy stem When Leaving 1 Before arm in g y our system, m ak e sure the Green Ready li g ht is ON. T his indicates that all of y our prot- ective zones are secur e. If any zones are open, the corres pondin g Zone li g ht will be ON. Secure these zones before proceedin g . If any z ones cannot be s ecured, see Bypassin g zones below. 2 Ent[...]
-
Página 7
Protecting Yourself While at Home 1 Before ar min g y our system, m ak e sure the Green Ready li g ht is ON. T his indicates that all of y our protective zones are sec ure. If any z ones are open, the corr espondin g Zone li g ht will be ON. Secure those zones before proc eedin g . 2 Enter y our user code. T he Green Ready li g ht will g o out, and[...]
-
Página 8
Emergency Buttons The two s ets of em ergency buttons, if pr ogramm ed, are always active whether the system is armed or disarm ed. Discuss these buttons with y our installer. The em ergency signal will only be activated when the two respective buttons ar e pressed at the sam e time. A uxiliary A larm: Simu ltaneously press + to alert the central s[...]
-
Página 9
Disarming Your Sy stem when Returning 1 Enter y our prem ises throu g h the Entry/Exit door. The k ey pad will sound a steady tone to rem ind y ou to disarm the system befor e y our Entry Delay tim e expires. 2 Enter y our user code. T he Red Ar m ed li g ht will g o out, indicatin g that the system has been dis armed. Note: If you mak e a mistak e[...]
-
Página 10
Special Functions By pressing follow ed by the appropriate key , (do not press simultaneously) these special functions and features can be enabled: Easy A rm ( w hen sy stem is disarm ed) The Easy Arm feature allows the system to be arm ed by pressing f ollowed by . This will allow the easy arm ing of the system by someone who is not a r egular[...]
-
Página 11
Your Installer has ass igned a User 1 Code which may be used to not only Arm and Disarm the system, but also to enter the User Program Mode, where y ou can program and/or reprogram up to 4 User Codes. The following explains how you w ill use this c ode to program or erase additional user codes . Entering the User Program Mode Press followed by and [...]
-
Página 12
The X P400 is constantly monitoring its own com ponents, as well as all c ritical services , such as AC Power and the Telephone line, to insure that it is alway s ready to provide the protection for which it was designed. W hen a sy stem trouble does occ ur, it will caution you by lighting the Yellow SYST EM light and beeping the keypad buzz er. If[...]
-
Página 13
13 9 Sy stem Tr oubl es Keypad Beeps or SYSTEM Flashes Zone light ON System Tr ouble Condition Action 2 Beeps 1 Bell / Siren Trouble There is a problem w ith the Bell or Siren. Call installing com- pany for service. 2 Beeps 3 W ireless Receiv er Trouble A problem has been detected w ith the wireless receiv er. Call installing company for serv ic[...]
-
Página 14
A mbush Code - In the event that y ou are for ced by an intruder to dis- arm y our system, this special code can be used to disarm the system, and sim ultane ously s end a s ilent alarm to Central Station. If y our sy s- tem has the Am bush f eature enabled, the code as signed as the User 4 code will function as your Am bush Code A rming / Disarmin[...]
-
Página 15
15 Notes Oi220a page 15 Tuesday, September 16, 1997 08:30[...]
-
Página 16
NA PCO LIM I TED WA RRANTY THE FOLL OW ING STATEM ENT I S REQUIRED BY THE FCC . This equipment generates and uses radio-frequency energy and, if not installed and used properly, that is, in strict accordance with the m anufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to com[...]