Patton electronic 1194 manual
- Consulta online o descarga el manual de instrucciones
- 24 páginas
- 0.3 mb
Ir a la página of
manuales de instrucciones parecidos
-
Network Card
Patton electronic 2300M
16 páginas 0.69 mb -
Network Card
Patton electronic 2160 Series
107 páginas 2.72 mb -
Network Card
Patton electronic 1082/F
28 páginas 0.39 mb -
Network Card
Patton electronic 1018RC
12 páginas 0.3 mb -
Network Card
Patton electronic 2294
53 páginas 0.96 mb -
Network Card
Patton electronic 1004
10 páginas 0.07 mb -
Network Card
Patton electronic 1314
43 páginas 0.69 mb -
Network Card
Patton electronic 1088/K
32 páginas 0.48 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Patton electronic 1194. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Patton electronic 1194 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Patton electronic 1194 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Patton electronic 1194, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Patton electronic 1194 debe contener:
- información acerca de las especificaciones técnicas del dispositivo Patton electronic 1194
- nombre de fabricante y año de fabricación del dispositivo Patton electronic 1194
- condiciones de uso, configuración y mantenimiento del dispositivo Patton electronic 1194
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Patton electronic 1194 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Patton electronic 1194 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Patton electronic en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Patton electronic 1194, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Patton electronic 1194, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Patton electronic 1194. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
USER MANUAL MODEL 1194 Single Mode Fiber Modem With Four Fixed E1/T1 Interfaces SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 P ar t# 07M1194-A Doc# 017151U A Released 06/04/01 An ISO-9001 Certified Company CERTIFIED[...]
-
Página 2
2 T ABLE OF CONTENTS 1.0 Warranty Information .................................................................. 4 1.1 Industry Canada Notice ................................................................ 4 1.2 FCC Information ........................................................................... 5 1.3 DC Power Notice .......................[...]
-
Página 3
3 Physical Connection ................................................................... 22 A.4 Fiber Port Specifications ..............................................................23 Fiber Line Coding ....................................................................... 23 Fiber Physical ......................................................[...]
-
Página 4
4 1.0 W ARRANTY INFORMATION P atton Electronics warrants all Model 1194 components to be free from def ects, and will—at our option—repair or replace the product should it f ail within one year from the first date of shipment. This warranty is limited to def ects in w orkmanship or mater ials, and does not cov er customer damage, ab use or una[...]
-
Página 5
5 and internal metallic water pipe system, are connected together . This protection ma y be par ticularly impor tant in r ural areas. 1.2 FCC INFORMATION This equipment has been tested and f ound to comply with the limits f or a Class A digital de vice, pursuant to P art 15 of the FCC Rules. These limits are designed to provide reasonab le protecti[...]
-
Página 6
6 An approv ed external SEL V power supply that incor porates a disconnect de vice must be used and positioned within reach of the operator’ s position. 1.4 PATTON CONTACT INFORMATION If you ha v e an y troub le operating the Model 1194, please contact P atton Electronics T echnical Suppor t at 301-975-1000 . The telephone com- pany ma y ask you [...]
-
Página 7
7 2. Y our telephone compan y may make changes to its f acilities, equip- ment, operations, or procedures that could aff ect the proper func- tioning of your equipment. The telephone company will notify y ou in advance of such changes to giv e you and oppor tunity to maintain uninterrupted telephone ser vice. 3. If your CSU causes harm to the telep[...]
-
Página 8
8 2.0 GENERAL INFORMATION Thank you f or your purchase of this P atton Electronics product. This product has been thoroughly inspected and tested and is warranted f or One Y ear par ts and labor . If any questions or problems arise during installation or use of this product, please do not hesitate to contact P atton Electronics T echnical Support a[...]
-
Página 9
9 Figure 2. Network extension between remote locations Using a laser transmitter (1300nm) and a single-mode fiber (9/125 micro meter), the Model 1194 off ers a high speed, noise immune , full duple x fiber link ov er a single str and of fiber with a reach of up to 15.5 miles (25.0 km). The Model 1194 is av ailable in two v ersions: 1194/T1 and 1[...]
-
Página 10
10 3.0 CONFIGURATION The Model 1194 has 16 DIP s witches that enab le configuration of the unit f or a wide v ar iety of applications. This section describes location of the s witches and e xplains the different configurations . 3.1 CONFIGURING THE HAR DWARE DIP SWITCHES Using a small flat-tip screwdriv er , remov e the protectiv e cov er locate[...]
-
Página 11
11 Configuring DIP switch S1 Switches S1-1 through S1-8 are used to configure clocking modes and line coding. Default settings of the s witches are shown in T able 1. Descriptions of the switch options f ollow the table . Switch S1-1: Line Coding Options. Use s witches S1-1 to deter mine the line coding of the network interface ports. The setting[...]
-
Página 12
12 tions and decodes them as zeros . This method enables the network to meet minimum pulse density requirements. • Bipolar 8 Zero Substitution (B8ZS ): This mode assures proper bit density in the data stream. In this mode any data pattern can be trans- mitted without causing ones density errors. This mode allows f or 64 kbps clear channel timeslo[...]
-
Página 13
13 Configure DIP switch S2 Switches S2-1 through S2-8 are f or configur ing Local/Remote Loop , RDL response, and front panel s witch oper ation (see T able 2). Descriptions of the s witch options follo w the table. Switch S2-1: Local/Remote Loop. Switch S2-1 determines which Loop can be activated from the front panel loop s witches (P1 to P4) Sw[...]
-
Página 14
14 4.0 INSTALLATION Once the Model 1194 is configured, it is ready to connect to the fiber interf ace , to the E1/T1 equipment, and to the power source. This section describes how to make these connections . The power , network (E1/T1), and fiber line connections are located on the rear panel of the Model 1194. Figure 5 shows the location of eac[...]
-
Página 15
15 Figure 7. Single-mode fiber connectors (FC and SC) . 4.3 POWER CONNECTION The Model 1194 is av ailable with two pow er supply options: • Universal Interface A C P ower Supply option (Model 1194-UI ) oper- ates in environments r anging from 100 to 240 V AC , with no re-configu- ration necessary (see Appendix B f or av ailable domestic and int[...]
-
Página 16
16 3. Set the ON/OFF power s witch (see Figure 8) to ON. Figure 8. P ower switch location Connecting to a DC P ower Source The 48 VDC power supply option uses a 3-pin terminal block with spring- type connectors. Please ref er to the Model 1090 Series Ser vice Manual f or the power line v oltage connections. Figure 9. DC power connection W ARNING Th[...]
-
Página 17
17 5.0 POWER-UP T o apply pow er to the Model 1194, first be sure that the unit is connected to the appropriate power source. Then do the f ollowing: 1. Set front panel s witches to the center position 2. Plug the provided A C or DC power into the Model 1194. 3. Set the ON/OFF power s witch (see Figure 8 on page 16) to ON. After the local and remo[...]
-
Página 18
18 6.0 LED STATUS MONITORS The Model 1194 f eatures front panel LEDs that monitor power , network, fiber , and diagnostic signals. Figure 10 shows the front panel location of each LED . T able 3 describes each LED’ s function. Figure 10. F ront panel picture of 1194 T able 3: F ront panel LED descriptions LED LED color Description PO WER Green I[...]
-
Página 19
19 7.0 T EST MODES The f ollowing section describes the test patter ns and loopbacks used in the Model 1194. The Model 1194 off ers local/remote loopbac k tests, plus a built-in V .52 BER test patter n generator to e v aluate the condition of the modems and the network (T1/E1 lines) and fiber links. These tests can be activated ph ysically from th[...]
-
Página 20
20 T o test the local connection, do the f ollowing: 1. Set S2-1 to the OFF position. 2. Locate the por t label (P1-P4) abov e or below the front panel s witches, Activ ate local loopback f or a network por t by moving the appropriate front panel toggle switch UP or DO WN. A yellow TM LED corresponding to the por t under test will tur n on. 3. A BE[...]
-
Página 21
21 T o test the fiber connection, do the f ollowing: 1. Set S2-1 to the ON position. 2. Locate the por t label (P1-P4) abov e or below the front panel s witches, Activ ate Remote Loopback f or a network por t by moving the appropriate front panel toggle switch UP or DO WN. A green TM LED corresponding to the por t under test will tur n on. A BER t[...]
-
Página 22
22 APPENDIX A MODEL 1194 QUAD E1/T1 TO SINGLE MODE FIBER SPECIFICATIONS A.1 CONFIGURATION Externally accessible dip switches A.2 CLOCKING MODES Network (E1/T1), Inter nal, Receiv e Recov er (fiber Link) A.3 NETWORK PORTS SPECIFICATIONS Network Line Rate 2048 kbps (G.703), 1.544Mbps (T1) T ransmit Line Buildout (T1) 0 dB, -7.5 db , -15 db , and -22[...]
-
Página 23
23 A.4 FIBER PORT SPECIFICATIONS Fiber Line Coding 8B10B Fiber Physical • Connection: One strand of 9/125 micron single-mode fiber with FC or SC connectors • T ransmission Line: Single fiber • Link Budget: 13 dB A.5 DIAGNOSTICS V .52 compliant (511/511E) patter n generator and detector with error injection mode. Remote Loopbac k (toward fi[...]
-
Página 24
24 A.12 HUMIDITY 5 to 95%, non-condensing A.13 DIMENSIONS 7.3 W x 6.6 D x 1.62H in. (185 W x 168 D x 41 H mm) A.14 WEIGHT 2.01 lbs. (1.0kg ) A.15 MEAN TIME BETWEEN FAILUR E (MTBF) 113,258 hours, based on MIL-HDBK-217F , Notice 2.[...]