Patton electronic 2094 manual
- Consulta online o descarga el manual de instrucciones
- 20 páginas
- 0.38 mb
Ir a la página of
manuales de instrucciones parecidos
-
Marine Battery
Patton electronic 2039
16 páginas 1.27 mb -
Marine Battery
Patton electronic 222N9
16 páginas 0.4 mb -
Marine Battery
Patton electronic 2017P60 RS-232 to 60mA
7 páginas 0.17 mb -
Marine Battery
Patton electronic 2094
20 páginas 0.38 mb -
Marine Battery
Patton electronic 2035-25M
16 páginas 1.27 mb -
Marine Battery
Patton electronic 2035
16 páginas 1.27 mb -
Marine Battery
Patton electronic 2017P RS-232 to 20mA
7 páginas 0.17 mb -
Marine Battery
Patton electronic RS-449/422 to V.35
6 páginas 0.06 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Patton electronic 2094. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Patton electronic 2094 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Patton electronic 2094 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Patton electronic 2094, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Patton electronic 2094 debe contener:
- información acerca de las especificaciones técnicas del dispositivo Patton electronic 2094
- nombre de fabricante y año de fabricación del dispositivo Patton electronic 2094
- condiciones de uso, configuración y mantenimiento del dispositivo Patton electronic 2094
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Patton electronic 2094 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Patton electronic 2094 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Patton electronic en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Patton electronic 2094, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Patton electronic 2094, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Patton electronic 2094. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
USER MANUAL MODEL 2094 V .35 to E1/Fractional E1 Converter SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www .patton.com P ar t# 07M2094-UM Doc# 08605U2-004, Re v . B Re vised 10/25/06 An ISO-9001 Certified Company Notes __________________________________________ __________________________________________ _____________________[...]
-
Página 2
P A TTON MODEL 2094 T ABLE OF CONTENTS Section Page 1.0 General Information ...............................................................2 1.1 W arranty Statement 1.2 Radio and TV Interference 1.3 CE Notice 1.4 Service Information 2.0 General Information ............................................................5 2.1 Features 2.2 General Produc[...]
-
Página 3
1.4 SERVICE INFORMA TION All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container . This number may be obtained from Patton Electronics T echnical Support at: tel: (301) 975-1007 ; email: support@pa[...]
-
Página 4
2.0 GENERAL INFORMA TION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warrant- ed for One Y ear parts and labor . If any questions arise during installa- tion or use of the unit, contact Patton Electronics T echnical Services at (301) 975-1007. 2.1 FEA TURES • T ermin[...]
-
Página 5
Switch SW1: Line Coding Use Switch SW1 to control the Network Line Coding options. Set these options to be the same as the Line Coding given to you by your Service Provider . If you are using two Model 2094s together as short range modems, set both units to HDB3. SW4 Line Framing & Coding Off HDB3 On AMI Line Coding Options: High Density Bipola[...]
-
Página 6
CLOCK MODES Network Clock T ransmitter timing is derived from the received line signal. Internal Clock T ransmitter clock is derived from an internal clock source. External Clock T ransmitter timing is derived from the local DTE device. V alid only in unframed mode. Note: When using the 2094 as a high-speed short range modem, one unit of the link m[...]
-
Página 7
NOTE: When the data rate is set to 2.048Mb/s, then the unit is forced into G.703 mode, and it transmits user data on all 32 times- lots. There is no framing information; therefore, the CAS MF (SW2) switch is ignored. SW3 is defaulted to clock mode. In all other rate settings, the unit employs G.704 framing; TS0 is reserved for signaling. 3.2 SOFTW [...]
-
Página 8
3.2.1 Introduction to Main Menu After entering the password, you may access all of the system’s functions and parameters. The Main Menu looks like this: HELPFUL HINTS 1. T o make a selection, key the highlighted letter that corre- sponds to a menu selection. 2. T o execute the selection, type [Enter/CR] 3. Select g Save Changes from Main Menu aft[...]
-
Página 9
3.2.2 System Configuration The System Configuration menu looks like this: The System Configuration options are described below: Line Format: G.703 (default) Options: G.703, G.704 G.703: G.703 is unframed, 2.048Mb/s. In this case, the DTE rate is equal to the line rate at the network interface (NI). CAS MF and CRC-4 are disabled. G.704: G.704 reserv[...]
-
Página 10
Clocking : Network (default) Options: Network, Internal, External Network: This is the most commonly used setting when connect- ing to a carrier ’s network. In this mode, the unit recovers the clock from the received signal and uses it to transmit data. In this way the unit remains synchronized to a master clock. In campus applications, one of th[...]
-
Página 11
3.2.3 System Diagnostics The System Diagnostics/Statistics screen looks like this: NOTE: This screen is updated once per second. The System Diagnostics/Statistics options and functions are described below . Local Loop Idle (default) The Local Loop is a bi-lateral loopback in which the data from the local DTE and the data from the remote unit are lo[...]
-
Página 12
22 21 Remote Loop Idle (default) The Remote Digital Loopback (RDL) test checks the performance of both the local and remote Model 2094s, as well as the communica- tion link between them. Data from the local DTE is sent across the entire communication circuit and looped back to the local DTE. The Model 2094 Initiating a RDL can be in one of the foll[...]
-
Página 13
23 24 Use this option to select the test pattern used to test the link. NI ST A TUS The Network interface (NI) status is shown in the middle of the Diagnostics/Statistics screen. The brackets are empty when the link is operating normally . Only one error message is provided Receiver Carrier Loss [RCL] occurs when 255 consecutive zeros have been det[...]
-
Página 14
25 26 Loop Timeout The Loop T imeout setting can be set to one of the following: 00:05 = five minutes 00:10 = ten minutes 00:15 = fifteen minutes 00:30 = thirty minutes (default setting) 00:45 = forty-five minutes 01:00 = one hour 01:30 = 90 minutes 02:00 = two hours 03:00 = three hours NEVER = forever—the unit will remain in loopback without use[...]
-
Página 15
27 28 4.3 POWER CONNECTION The Model 2094 offers three ways to supply external power: AC power , DC power and interface power . 4.3.1 Using the AC Power Supply (100-240V AC) The Model 2094 uses a 5VDC, 2A universal input 100-240V AC, power supply (center pin is +5V). The universal input power supply is equipped with a male IEC-320 power entry conne[...]
-
Página 16
29 30 LOS The Loss of Sync LED lights when the unit loses synchronization with the incoming sig- nal. This may happen when there is a fram- ing mismatch or a loss of signal. In unframed mode, the LOS LED monitors the status of the transmit clock. ALM The alarm LED indicates the presence of a AIS or RAI, or Out of Frame condition. The ALM LED will b[...]
-
Página 17
31 32 T o perform an RDL test, follow these steps: 1. Activate RDL. This may be done in two ways: a. Enter Remote Loop from the System Diagnostics/Statistics menu and toggle the <Spacebar> until “TM” appears next to the Remote Loop option.; b. Activate the “RL” signal on the DTE. If you are not sure which lead is the “RL” signal, [...]
-
Página 18
33 34 APPENDIX A P A TTON MODEL 2094 SPECIFICA TIONS Network Data Rate: 2.048 Mbps Network Connector: RJ-48C Nominal Impedance: 120 ohm (75 ohm available when using Patton Model 460 Balun) DTE Interface: V .35 (DCE Orientation) on Male M/34 Line Coding: Selectable AMI or HDB3 Line Framing: G.703 (Unframed) or G.704/G.732 (Framed) CAS Multiframing: [...]
-
Página 19
35 36 APPENDIX C P A TTON MODEL 2094 F ACTOR Y REPLACEMENT P ARTS AND ACCESSORIES Patton Model # Description 2094/CM/UI .....................V .35 to E1 Converter (V .35 M/34 Male, UI) 10 - 09F ...........................6 Foot Control Port Cable, 25 mm to DB9F 08055DCUI......................Universal Input Power Supply 10-CISCO-V35FT -1 .........C[...]
-
Página 20
37 38 APPENDIX D (continued) P A TTON MODEL 2094 INTERF ACE PIN ASSIGNMENTS M/34 Connector , T erminal Interface Pin # Signal A GND (Earth Ground/Shield) B SGND (Signal Ground) D CTS (DCE Source) E DSR (DCE Source, Always On) F CD (DCE Source) L LL (Local Loop, DTE Source) M TM (T est Mode Indicator (DCE Source) N RL (Remote Loop, DTE Source) P TD [...]