Ir a la página of
manuales de instrucciones parecidos
-
Oxygen Equipment
ResMed S
22 páginas 2.09 mb -
Oxygen Equipment
ResMed 618143 Quattro FX NV
17 páginas 6.45 mb -
Oxygen Equipment
ResMed 60605
1 páginas 0.09 mb -
Oxygen Equipment
ResMed 618362
86 páginas 2.85 mb -
Oxygen Equipment
ResMed 62102
1 páginas 0.04 mb -
Oxygen Equipment
ResMed 60603
1 páginas 0.09 mb -
Oxygen Equipment
ResMed 2i
26 páginas 0.41 mb -
Oxygen Equipment
ResMed 60625
1 páginas 0.09 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones ResMed VPAP AUTO 25. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica ResMed VPAP AUTO 25 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual ResMed VPAP AUTO 25 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales ResMed VPAP AUTO 25, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones ResMed VPAP AUTO 25 debe contener:
- información acerca de las especificaciones técnicas del dispositivo ResMed VPAP AUTO 25
- nombre de fabricante y año de fabricación del dispositivo ResMed VPAP AUTO 25
- condiciones de uso, configuración y mantenimiento del dispositivo ResMed VPAP AUTO 25
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de ResMed VPAP AUTO 25 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de ResMed VPAP AUTO 25 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico ResMed en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de ResMed VPAP AUTO 25, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo ResMed VPAP AUTO 25, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual ResMed VPAP AUTO 25. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
VP AP™ A uto 25 VP AP™ S T VP AP™ S Positive Airw A y Pressure device User Guide English[...]
-
Página 2
English VP AP™ A uto 25 VP AP™ S T VP AP™ S POSITIVE AIRW A Y PRESSU RE DEVICE User Guide English ResMed Ltd (Manufacturer) 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia ResMed Corp (US Designated Agent) 14040 Danielson Street Poway CA 92064-6857 USA ResMed (UK) Ltd (EU Authorized Representative) 96 Milton Park Abingdon Oxfordshi[...]
-
Página 3
Cont ents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Contraindications 1 A dverse Ef f ects 1 The VP AP S ystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Masks 2 Humidifier 2 R esScan Dat a Card 2 Supplement al Oxy gen 3 Using the VP AP Aut[...]
-
Página 4
1 Introduction English Introduction The VPAP TM Auto 25 , VPAP TM ST and the VPAP TM S are i ndicated for the treatment of obstructive sle ep apnea (OSA) in patien ts weighing more th an 66 lb (30 kg). T hey are intended for home and hospi tal use. Contraindications Positive ai rway pressure therapy may be contraindic ated in some patien ts with th[...]
-
Página 5
2 Masks The following ResMed mask systems are recommended for use wi th these devices: For information on using masks, see your mask manual. For th e latest available masks, see www.resmed.co m. Humidifier If you are ex periencing dryness o f the nose, throat or mouth, the H4i heated humidifier is recommended for use with these VPAP devices. ! WARN[...]
-
Página 6
3 Using the VP AP Auto 2 5, VP AP ST & VP AP S English Supplemental Oxygen The VPAP Auto 25, VP AP ST and VPAP S are designed to be compatibl e with the following levels of suppl emental oxygen usage: • Up to 4 L/ min in V Auto mode • Up to 1 5 L/min in CP AP , S , ST and T mode s. At a fixed flow rate of supple mental oxygen flow, the inha[...]
-
Página 7
4 ! CAUTION • Be careful not to place the device where it can be bumped or where someone is likely to trip ov er the power cord. • If you put the device on the fl oor , make sure the area is free from dust and clear of bedding , clothes or other objects th at could bloc k the air inlet. Attaching a H4i Humidifier The H4i humidifier attach es to[...]
-
Página 8
5 Using the VP AP Auto 2 5, VP AP ST & VP AP S English Using the Menus The VPAP Au to 25 , VPAP ST and VPAP S provi de a set of functions which are arranged in menus and submenus. Via the LCD screen, the menus and submenus allow you to view and change the settin gs for a particular function. To navigate and make selecti ons with in the Patient [...]
-
Página 9
6 How to Select the Mask Type Scroll to MASK and select . Press or until you see the setting you require. The following ta ble shows the setting that should be se lected for each mas k: How to change the EPR level (CPAP mode) Expiratory Pressure Re lief (EPR) can be used to improve your comfor t level when breathing out duri ng treatment. If patien[...]
-
Página 10
7 Using the VP AP Auto 2 5, VP AP ST & VP AP S English Starting Treatment 1 Make sure the power is on. The product name is displaye d briefly on the LCD screen, then the standby (Ramp/ Settle) screen app ears. The key and LCD backlights also turn on. 2 Fit your mask as described in the ma sk user instructions. ! WARNING A mask should not be use[...]
-
Página 11
8 Using the Mask-Fitting feature The VPAP Au to 25, VPAP ST and VPAP S include a m ask-fitting feature to help you fit your mask properly. The mask-fitti ng fe ature delivers air pressure for a three- minute period, pri or to starting treatment, for checki ng and adjusting your mask fit to minimize leaks. To use the mask-fitting feature: 1 Fit your[...]
-
Página 12
9 Using the VP AP Auto 2 5, VP AP ST & VP AP S English Using the Data Card If your clinici an needs to review your treatment, they will ask you to use the Data Card to copy data from your VPAP devic e and return the card to them. Copying Data onto a Data Card 1 Switch on your VPAP and wait until you see the standby (Ramp /Settle) screen. 2 Hold[...]
-
Página 13
10 Traveling with the VPAP Auto 25, VPAP ST & V PAP S International Us e Your VPAP flow generator has an internal pow er adapter that en ables it to operate in other countries. It wil l operate on power supplies of 100–240V and 50–60Hz. No special adju stment is necessary, b ut you will require an approved p ower cord for that country. Use [...]
-
Página 14
11 Cleaning and Maintenance English Cleaning and Maintenance You should regularly carry out the cleani ng and maintenance described in this secti on. Refer to your mask and humidifier manuals fo r detailed instru ctions regarding the care of those devices. Daily Disconnect the air tubing and hang it in a clean , dry place until next use. Weekly 1 R[...]
-
Página 15
12 ! WARNING • Do not wash the air filter . Th e air filter is not wa shable or reusable. • The air filter co ver protects the devi ce in th e event of accidental liqui d spillage on to the device. Ensure the air filter and air fi lter cover are fit ted at all times. Servicing This product should be i nspected by an authorize d ResMed service c[...]
-
Página 16
13 T roubleshooting English Troubleshooting If there is a problem, try th e following suggestions. If the problem cannot be sol ved, contact your equi pment supplier or Re sMe d. Do not attempt to open the device. No display Insufficient air delivered fr om the VP AP device Device does not star t when you b rea the int o the mask Device does not s [...]
-
Página 17
14 Displays er ror message: Check tube!! Key if done Displays er ror message: Exxxx Call Service (wher e xxxx defines an er ror) Displays er ror message: HIGH LEAK!!! Adjust Mask The follo wing message is display ed on the LCD afte r you try to update set tings or copy data to the D ata Car d: Card Error Remove Card The follo wing message is displa[...]
-
Página 18
15 T echnical Specifications English Technical Specifications Note: The manufact urer r eser ves the ri ght to c hange th ese specif ications without notice. Symbols Which Appear On The Device At tention, consult accompany ing document s; Drip proof; T ype CF equipm ent; Dangerous voltage; Class II equipment; Start/Stop ; Manufacturer . Operating p[...]
-
Página 19
16 General Warnings and Cautions ! Warnings • Advice contained in this manual should not supersede instructions given b y the prescribing phy sician. • A patient should not connect a device to the dat a communicati on port unless instr ucted to do so by their health care pro v ider or phys ician. Only ResMed products are designed to be connecte[...]
-
Página 20
17 General W arnings and Cautions English Guidance and Manuf actur er ’ s Declaration – Electromagnetic Emission s and Immunity Guidance and manuf acture r ’ s declar ation – electromagnetic emissions The V P AP Auto 25 , VP AP S T and VP AP S de vices are intended f or use in the electromagne tic envir onment specified below . The customer[...]
-
Página 21
18 Guidance and man uf acturer’ s declaration – electromagnetic immuni ty The VP AP devi ce is intende d for use i n the electrom agnetic en vironment spec ified belo w . T he customer or the user of th e VP AP devi ce should assu re that the de vice is us ed in suc h an environ ment. Immunit y test I E C 6 0 6 01- 1- 2 te s t level Complianc e[...]
-
Página 22
19 Limited W arranty English Limited Warranty ResMed warrants that your ResMed product shall be free fro m defects in material and workmanshi p for the period sp ecified below from th e date of purchase by the initial consum er. This w a rranty is not transferable. Note: Some mode ls are not available in all regi ons. If the product fails under con[...]