Scytek electronic 3000Plus Series manual
- Consulta online o descarga el manual de instrucciones
- 28 páginas
- 1.02 mb
Ir a la página of
manuales de instrucciones parecidos
-
Automobile Alarm
Scytek electronic 5500
52 páginas 0.7 mb -
Automobile Alarm
Scytek Electronic 5000RS-2W
36 páginas 0.94 mb -
Automobile Alarm
Scytek electronic A10
20 páginas 0.23 mb -
Automobile Alarm
Scytek electronic 5100RS
48 páginas 0.92 mb -
Automobile Alarm
Scytek electronic ASTRA 777
28 páginas 0.32 mb -
Automobile Alarm
Scytek electronic 8000
36 páginas 0.79 mb -
Automobile Alarm
Scytek electronic 600
24 páginas 1.6 mb -
Automobile Alarm
Scytek electronic 70000000
28 páginas 0.35 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Scytek electronic 3000Plus Series. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Scytek electronic 3000Plus Series o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Scytek electronic 3000Plus Series se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Scytek electronic 3000Plus Series, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Scytek electronic 3000Plus Series debe contener:
- información acerca de las especificaciones técnicas del dispositivo Scytek electronic 3000Plus Series
- nombre de fabricante y año de fabricación del dispositivo Scytek electronic 3000Plus Series
- condiciones de uso, configuración y mantenimiento del dispositivo Scytek electronic 3000Plus Series
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Scytek electronic 3000Plus Series no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Scytek electronic 3000Plus Series y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Scytek electronic en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Scytek electronic 3000Plus Series, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Scytek electronic 3000Plus Series, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Scytek electronic 3000Plus Series. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
3 3 0 0 0 0 0 0 P P L L U U S S S S E E R R I I E E S S VEHICLE SECURITY SYSTEM PRODUCT MANUAL[...]
-
Página 2
[...]
-
Página 3
1. About Y our System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 1 2. Remote T ransmitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 2 Remote T ransmitter Description . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]
-
Página 4
[...]
-
Página 5
The ScyT ek Galaxy 3000 Plus is a state-of-the-art vehicle security system f eaturing a built-in "ScyNet Network Port" that allows direct connection of optional accessory modules and a PC interface offering expanded system oper ation. With proper installation this system will provide superior protection and performance for many y ears to [...]
-
Página 6
Remote Transmitter Description The Galaxy 3000 Plus is supplied with two 5-button Remote T r ansmitters used to control system operations. Note : Using the optional PC or Pock et PC interface with the network software, it is possible to reconfigure the functionality of the tr ansmitter buttons. The standard (default) setting for oper ation of the t[...]
-
Página 7
Adding/Replacing Transmitters T o replace lost or stolen transmitters or to add additional tr ansmitters into the system, have all desired transmitters ready and f ollow the steps below. Note : Up to 4 transmitters can be progr ammed to operate the system. T o erase an y previously stored transmitter codes, be sure to progr am all 4 transmitter mem[...]
-
Página 8
Page 4 - Galaxy 3000 Plus Remote Arming The system monitors 6 independent areas ( zones ) while armed: doors, hood, trunk, shock sensor , optional sensor input, and the network port for future expansion. T o Arm the System: 1. T urn off the ignition. 2. Press Button 1. · The siren will chirp once.* · The doors will lock. · The parking lights wil[...]
-
Página 9
Tamper Alert If the system was triggered while away , the LED will flash to indicate which zone triggered the system after disarming and turning on the ignition. The LED indication will repeat for 20 seconds. LED Flashes (60 seconds): 1 flash = optional sensor 2 flashes = shock sensor 3 flashes = network based sensor 4 flashes = door 5 flashes = tr[...]
-
Página 10
Panic Mode In the event of an emergency the transmit ter ’ s remote Panic feature can be used to instantly trigger the alarm. T o activate the P anic Mode: 1. Press and hold Button 1 for 3 seconds. · The alarm will sound. · The parking lights will flash. · The doors will unlock* allowing access to the vehicle. 2. Press Button 2 to stop Panic M[...]
-
Página 11
T o set the Emergency Override Code: 1. T urn on ignition. 2. Within 5 seconds, press the valet switch 5 times. · The siren will provide one long chirp, indicating that you ha ve entered Programming. 3. Press the valet switch 4 times. · The siren will chirp each time the valet switch is pressed. 4. Within 5 seconds, press Button 3 on the transmit[...]
-
Página 12
Page 8 - Galaxy 3000 Plus Ignition Door Locking For added saf ety , the Ignition Door Locking feature allows vehicles equipped with power door lock systems to automatically lock the doors when the ignition is turned on. If a door is open when the ignition is turned on, the Ignition Door Locking feature is disabled to protect against locking the key[...]
-
Página 13
Remote Sensor Disable When parking the vehicle in areas susceptible to unwanted disturbance from animals or strong weather conditions that could cause the sensors to trigger , the sensor inputs can be temporarily bypassed using the Remote T ransmit ter , prev enting possible false alarms. T o disable the sensor inputs : 1. Arm the system normally .[...]
-
Página 14
Page 10 - Galaxy 3000 Plus[...]
-
Página 15
Galaxy 3000 Plus - Page 11 1. Thoroughly read and become familiar with the installation instructions before beginning the installation. 2. Review system contents: Main Unit T wo 5-Button Remote T r ansmitters Siren Shock Sensor Harnesses • 16-Pin main harness • 4-Pin shock sensor harness • 3-Pin door lock harness • LED harness • Override [...]
-
Página 16
Mounting the Control Unit The control unit must only be mounted in the interior of the vehicle. Do not mount the main unit in the engine compartment. Choose a mounting location that will not be easily accessible to a thief , and will not interfere with the operation of any vehicle components such as foot pedals, steering column, air vents, seat r a[...]
-
Página 17
Galaxy 3000 Plus - Page 13 S ys t em W W i ri n g 16-Pin Main Harness Pin 1 BROWN WIRE : Siren Output (+) 3A. The Brown wire must connect to the siren’ s red wire. The Black siren wire must be grounded. Pin 2 BLACK WIRE : Ground Input (-). The Black wire must connect to a solid chassis ground. Clean away any paint or dirt to insure the best possi[...]
-
Página 18
Page 14 - Galaxy 3000 Plus Starter Defeat Connectors Using a volt/ohm meter locate the starter wire (normally a heavier gauge wire) at the ignition switch. This wire will show +12V only during cranking. When this wire is cut the vehicle will be unable to start. Locate the BROWN starter disable wire included with the wiring harness and cut in half .[...]
-
Página 19
Galaxy 3000 Plus - Page 15 Jumper Selections Carefully separate the top and bot tom halves of the main unit case. Once the cover is removed, the polarity jumpers will be visible next to the parking light and dome light relays. Set the jumpers for the correct polarity output as described below , then reassembly the main unit case. Parking Light Outp[...]
-
Página 20
Page 16 - Galaxy 3000 Plus Entering System Programming T o enter System Progr amming: 1. T urn on ignition. 2. Within 5 seconds, press the valet switch 5 times. · The siren will provide one long chirp, indicating that you ha ve entered Programming. 3. Press the valet switch the number times equal to the S ystem Parameter you w ant to change. · Th[...]
-
Página 21
after the ignition key is turned on. Ov erride Code S et. Changes the Emergency Override Code for a higher lev el of security . 5. Ignition Door Unlocking. Selects whether or not the system automatically unlocks the doors when the ignition is turned off . The Ignition Door Locking feature may be programmed to unlock all doors or the driver’s door[...]
-
Página 22
10. Ignore Open Door Report. Bypasses the open zone warning chirps f or vehicles equipped with a residual dome light circuit that remains on for a period of time after closing the door . 11. Horn Chirps with Arm & Disarm / Anti-Carjack with Valet Reset. This dual program branch activates the horn chirps during Arming and Disarming, and activ at[...]
-
Página 23
18. Start in Valet Mode.* Selects whether or not the vehicle can remote start while in the valet mode. *Requires the optional ScyNet Network R emote Car Start Module. 19. Remote Start Program .* This dual program br anch sets the engine mode for Gas or Diesel, and learns the vehicle’ s RPM threshold. Learn RPM. When programming Branch 19, first s[...]
-
Página 24
Page 20 - Galaxy 3000 Plus Negative T rigger Positiv e T rigger Reverse P olarity V acuum Adding Actuators Follow the diagr ams below for connecting basic door lock systems. For T wo Stage door lock systems (separately unlocks driver and passenger doors) see f ollowing pages. D oo r L L o c k D D iagrams[...]
-
Página 25
Galaxy 3000 Plus - Page 21 T wo S S ta g e D D oor L L oc k D D i ag r am s T wo Stage Negative T rigger T wo Stage P ositive T rigger The Galaxy 3000 Plus is equipped with a dedicated Passenger Unlock output allowing T wo Stage Door Lock operation. When connected as shown below , disarming the system will unlock only the driver’s door . Pressing[...]
-
Página 26
Page 22 - Galaxy 3000 Plus T wo S S ta g e D D oor L L oc k D D iagrams c c on t ’d T wo Stage Rev erse Polarity T wo Stage Adding Actuators[...]
-
Página 27
Galaxy 3000 Plus - Page 23 FCC ID: OARRXAM2000 This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation T ec hn i ca l I I nf o rm a ti o n[...]
-
Página 28
ScyTek Electronics 11627 Cantara Street Unit B North Hollywood, CA 91605 © ScyT ek Electronics 2002 Galaxy 3000 Plus r1 9/02 W ir in g D D i a gr a m[...]