SPX Cooling Technologies SS-NC-08A manual
- Consulta online o descarga el manual de instrucciones
- 24 páginas
- 1.59 mb
Ir a la página of
manuales de instrucciones parecidos
-
Humidifier
SPX Cooling Technologies Recold M
4 páginas 0.56 mb -
Humidifier
SPX Cooling Technologies Marley MH Marley MH Fluid Cooler
36 páginas 0.84 mb -
Humidifier
SPX Cooling Technologies MXF 3000
12 páginas 1.71 mb -
Humidifier
SPX Cooling Technologies NCF-06
8 páginas 1.06 mb -
Humidifier
SPX Cooling Technologies BA-07011
12 páginas 1.29 mb -
Humidifier
SPX Cooling Technologies 300 series
16 páginas 4.06 mb -
Humidifier
SPX Cooling Technologies 1200
32 páginas 1.58 mb -
Humidifier
SPX Cooling Technologies Marley MC
8 páginas 1.04 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones SPX Cooling Technologies SS-NC-08A. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica SPX Cooling Technologies SS-NC-08A o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual SPX Cooling Technologies SS-NC-08A se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales SPX Cooling Technologies SS-NC-08A, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones SPX Cooling Technologies SS-NC-08A debe contener:
- información acerca de las especificaciones técnicas del dispositivo SPX Cooling Technologies SS-NC-08A
- nombre de fabricante y año de fabricación del dispositivo SPX Cooling Technologies SS-NC-08A
- condiciones de uso, configuración y mantenimiento del dispositivo SPX Cooling Technologies SS-NC-08A
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de SPX Cooling Technologies SS-NC-08A no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de SPX Cooling Technologies SS-NC-08A y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico SPX Cooling Technologies en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de SPX Cooling Technologies SS-NC-08A, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo SPX Cooling Technologies SS-NC-08A, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual SPX Cooling Technologies SS-NC-08A. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
/ Mar le y NC Class Stainless Crossflow Cooling T ower / Pr od uct S pec ifica tio ns[...]
-
Página 2
Specifications / Base Base 4 Thermal P erformance 4 P erformance W arranty 5 Design Loading 5 Construction 6 Mec hanical Equipment 7 Fill, Louvers and Drift Eliminator s 8 Hot W ater Distribution System 9 Casing, F an Dec k and Fan Cylinder 9 Access 1 0 Cold W ater Collection Basin 1 0 Specifications / Options Conv enience and Saf ety Options Guard[...]
-
Página 3
Mar ley / NC Class Stainless Cooling T ower / 3 NC Class Stainless Steel towers are factory assembled, crossflo w cooling tow ers, designed to ser ve air conditioning and refrigeration systems as well as light to medium industrial process loads on clean water . The y ev olve from a factor y-assembled concept of to wers pioneered by Marle y some 50[...]
-
Página 4
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Base 4 1.0 Base: 1.1 Pro vide an induced draf t, crossflow type, factory assembled, film fill, industrial dut y , st ainless steel cooling tow er situated as shown on the plans. The limiting ov erall dimensions of the tower shall be _____ wide, _____ l[...]
-
Página 5
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Base 5 2.0 Ther mal P erfor mance and Efficiency: 2.1 The tow er shall be capable of cooling _____ m 3 /h of water from ____ °C to _____ °C at a design entering air wet- bulb temperature of _____ C and its thermal rating shall be Certified by the Coo[...]
-
Página 6
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Base 6 designed for 2.4kP a live load or a 91kg concentrated load. Guardrails, where specified, shall be capable of with- standing a 890N concentrated live load in any direction, and shall be designed in accordance with OSHA guidelines. 5.0 Constr ucti[...]
-
Página 7
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Base 7 5.3* The tow er shall include all design and material modifications necessar y to meet the fire rating requirements of Factory Mutual. The product proposed shall be listed in the FM Approval Guide, latest edition. *Standard on models NC8301 thru[...]
-
Página 8
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Base 8 LOUVER S DRIFT ELIMINA T OR separ ate from fill on some models FILL 7.0 Fill, Louvers and Dr ift Eliminators: 7.1 Fill shall be film t ype, thermof ormed of 0.40mm thic k PV C, with louvers formed as part of eac h fill sheet. Fill shall be susp[...]
-
Página 9
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Base 9 8.0 Hot W ater Distribution Syst em: 8.1 T wo st ainless steel open basins (one abov e eac h bank of fill) shall receive hot water piped to eac h cell of the tow er . These basins shall be inst alled and sealed at the factor y , and shall be equ[...]
-
Página 10
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Base 10 10.0 Access: 10.1 A large st ainless steel, rectangular access door shall be located on both end panels for entr y into the cold water basin. Doors shall provide access to the fan plenum area to facili- tate inspection and allow maintenance to [...]
-
Página 11
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Options 11 Conv enience and Saf ety Options Guardr ail and Ladder: 11.2 Add the following paragraph in the Access section: The top of the tow er shall be equipped with a sturdy guardrail, complete with kneerail and toeboard, designed according to OSHA [...]
-
Página 12
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Options 12 ACCESS DOOR PLA TFORM GU ARDRAIL LADDER LADDER EXTENSION[...]
-
Página 13
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Options 13 Access Door Platfor m: 11.2 Add the following paragraph in the Access section: There shall be an access platform at the base of the tow er extending from the vertical lad- der to the endwall access door . The platform shall be galvanized ste[...]
-
Página 14
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Options 14 Control Options Fan Motor Starter Control Panel: 6.4 Add the following paragraph in the Mechanical Equipment sec- tion: Each cell of the cooling to wer shall be equipped with a UL listed control system in a IP1 4 or IP56 out- door enclosure [...]
-
Página 15
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Options 15 Vibr ation Limit Switc h: 6.5 Add the following paragraph in the Mec hanical Equipment section: A single-pole, double-throw vibration limit switch in a IP56 housing shall be installed on the mec hanical equipment support for wiring into the [...]
-
Página 16
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Options 16 in quantities and locations as indicated on the drawings. An overflo w and drain connection shall be provided in eac h cell of the cooling tower . The basin floor shall slope tow ard the drain to allow complete flush out of debris and silt w[...]
-
Página 17
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Options 17 cold-water temperature. The application must be able to handle ver y cold water while VFD is in a by -pass mode. Operator controls shall be mounted on the front of the enclosure and shall consist of start and stop control, bypass/VFD selecti[...]
-
Página 18
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Options 18 shall be operated as a st and- alone sys- tem without the need for a BMS system. Operator controls shall be mounted on the front of the enclosure and shall consist of st art and stop control, bypass/ VFD selector switc h, Auto/Manual selecto[...]
-
Página 19
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Options 19 Inlet Flow Contr ol V alves: 8.2 : Add the following to the end of the paragraph: Heavy-duty flow -regulator valv es shall be provided at the hot water inlet connections. These valv es shall be disc-t ype, with cast iron bodies and st ainles[...]
-
Página 20
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Options 20 box whic h is self supporting . The inlet at tenuation will not be allow ed to impact the thermal performance ef fi- ciency of the basic tower configuration. Outlet Sound At tenuation 1.4 Add the following paragraph under Base: The cooling t[...]
-
Página 21
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Options 21 Ultra Low-Noise F an 1.4 Replace paragraph 6.1 with the fol- lowing: Fan(s) shall be propeller -type, incorporating wide-chord for ward- swept FRP blades and galvaniz ed hubs. Blades shall be individually adjustable. Maximum f an tip speed s[...]
-
Página 22
Specifications Specification V alue Mar ley / NC Class Stainless Cooling T ower / Specifications: Options 22 ______ psf, as well as a ______ seismic load. The fan dec k and hot water basin cov ers shall be designed for 50 psf live load or a 200 lb. concentrated load. Guardrails, where specified, shall be capable of withst anding a 200 lb. con- cent[...]
-
Página 23
[...]
-
Página 24
In the interest of techno logical progr ess, all products are subject to design and/or material change without notice. ©2008 SPX Cooling T echnologies uk_SP EC- S S-N C -08A SPX C OO LIN G TEC H NO L O G I ES U K L TD. G R EGO RY’S BAN K WOR CESTE R WR3 8AB U N ITE D K I NG DO M +44 (0) 1905 7 20 200 info.uk@spx.com spxcooling.com[...]