State Industries GS6 30 YOCT Series 201 manual
- Consulta online o descarga el manual de instrucciones
- 36 páginas
- 2.26 mb
Ir a la página of
manuales de instrucciones parecidos
-
Water Heater
State Industries SERIES 108
55 páginas 13.31 mb -
Water Heater
State Industries PR6 6 10MS
4 páginas 0.09 mb -
Water Heater
State Industries SHE50 76
4 páginas 0.05 mb -
Water Heater
State Industries SRGSS01806
2 páginas 1.48 mb -
Water Heater
State Industries GPX-40 YXRS
2 páginas 0.11 mb -
Water Heater
State Industries SBD71120NE
36 páginas 0.53 mb -
Water Heater
State Industries GS6 40 YOCT Series 200
36 páginas 2.26 mb -
Water Heater
State Industries GPX-40
2 páginas 0.11 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones State Industries GS6 30 YOCT Series 201. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica State Industries GS6 30 YOCT Series 201 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual State Industries GS6 30 YOCT Series 201 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales State Industries GS6 30 YOCT Series 201, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones State Industries GS6 30 YOCT Series 201 debe contener:
- información acerca de las especificaciones técnicas del dispositivo State Industries GS6 30 YOCT Series 201
- nombre de fabricante y año de fabricación del dispositivo State Industries GS6 30 YOCT Series 201
- condiciones de uso, configuración y mantenimiento del dispositivo State Industries GS6 30 YOCT Series 201
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de State Industries GS6 30 YOCT Series 201 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de State Industries GS6 30 YOCT Series 201 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico State Industries en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de State Industries GS6 30 YOCT Series 201, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo State Industries GS6 30 YOCT Series 201, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual State Industries GS6 30 YOCT Series 201. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
1 This water heater complies with ANSI Z21.10.1-current edition regarding the accidental or unintended ignition of fl ammable vapors, such as those emitted by gasoline. For Y our Safety AN ODORANT IS ADDED T O THE GAS USED BY THIS W A TER HEA TER. • Safety Instructions • Installation • Operation FVIR GAS WATER HEATER (FLAMMABLE V APOR IGNITI[...]
-
Página 2
2 T ABLE OF CONTENTS W ater Heater Safety .............................................................................................................................. ............................................ 1 -2 Safe Installation, Use and Service ................................................................................................[...]
-
Página 3
3 SAFE INST ALLA TION, USE AND SER VICE Y our safety and the safety of others is extremely important in the installation, use and servicing of this water heater . Many safety-related messages and instructions have been provided in this manual and on your water heater to warn you and others of a potential hazard. Read and obey all safety messages an[...]
-
Página 4
4 Fire or Explosion Harzard Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Avoid all ignition sources if you smell Natural or LP gas. Do not expose water heater control to excessive gas pressure. Use only gas shown on rating plate. Maintain required clearances to combustibles. Keep[...]
-
Página 5
5 TYPICAL INST ALLA TION GET TO KNOW YOUR W A TER HEA TER - GAS MODELS A V ent Pipe B Draft hood C Anode (Not Shown) D Hot W ater Outlet E Insulation F Gas Supply Piping G Manual Gas Shut-off V alve H Ground Joint Union I Drip Leg (Sediment T rap) J Inner Door K Outer door L Union M Inlet W ater Shut-off V alve N Cold W ater Inlet O Inlet Dip T ube[...]
-
Página 6
6 INST ALLING YOUR GAS W A TER HEA TER Important Information About This W ater Heater This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable vapor ignition incident. New technology used in meeting these standards makes this product more sensitive to installation errors or improper installation e[...]
-
Página 7
7 Location Requirements Carbon Monoxide Poisoning Hazard W ARNING Do not install in a mobile home. Doing so can result in carbon monoxide poisoning and death. The FVIR System is designed to reduce the risk of flammable vapor-related fires. The patented system protects your family by trapping the burning vapors within the water heater combustion cha[...]
-
Página 8
8 IMPORT ANT : The water heater should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to the water heater or to lower floors of the structure. Due to the normal corrosive action of water , the tank will eventually leak after an extended period of time. Also any external plumbing leak, i[...]
-
Página 9
9 CHECK WITH LOCAL UTILITY FOR MINIMUM HEIGHT 3” MINIMUM DRIP LEG GROUND JOINT UNION SUIT ABLE DRAIN MANUAL GAS SHUT -OFF VAL VE DISCHARGE PIPE (DO NOT PLUG OR CAP) 6” MAXIMUM AIR GAP FIGU RE 3 . Gas Pressure W ARNING Explosion Hazard • Gas leaks can not always be detected by smell. • Gas suppliers recommend that you use a gas detector appr[...]
-
Página 10
10 LP Gas Only W ARNING Explosion Hazard Have a qualified person make sure L.P . gas pressure does not exceed 13” water column. Examples of a qualified person include: licensed plumbers, authorized gas company personnel, and authorized service personnel. Failure to do so can result in death, explosion, or fire. Liquefied petroleum gas is over 50%[...]
-
Página 11
11 T ABLE 3 BTUH Input Minimum Square Feet with 8’ Ceiling T ypical Room with 8’ Ceiling 30,000 188 9 x 21 45,000 281 14 x 20 60,000 375 15 x 25 75,000 469 15 x 31 90,000 563 20 x 28 105,000 657 20 x 33 120,000 750 25 x 30 135,000 844 28 x 30 IMPORT ANT : • The area must be open and be able to provide the proper air requirements to the water [...]
-
Página 12
12 12” MAXIMUM PERMANENT OPENINGS TO T HE OUTSIDE OR ADDITIONAL ROOMS WITHIN THE BUILDING CLOSET OR OTHER CONFINED SPACE 12” MAXIMUM FIG UR E 4. All Air from Inside the Building When additional air is to be provided to the confined area from additional room(s) within the building, the total volume of the room(s) must be of sufficient size to pr[...]
-
Página 13
13 ALTERNATIVE OPENING LOCATION 1 SQ. INCH PER 3000 BTUH CONFINED SPACE ALL AIR FROM OUTDOORS - USING A SINGLE PERMANENT OPENING FIGU RE 8 B. V ent Pipe System This water heater uses a non-direct, single-pipe vent system to remove exhaust gases created by the burning of fossil fuels. Air for combustion is taken from the immediate water heater locat[...]
-
Página 14
14 Align the legs of the draft hood with the slots provided. Insert the legs and secure the draft hood to the water heater ’s top with the four screws provided as shown in Figure 9. Do not alter the draft hood in any way . If you are replacing an existing water heater , be sure to use the draft hood supplied with this water heater . V ent Pipe Si[...]
-
Página 15
15 Piping Installation Piping, fittings, and valves should be installed according to the installation drawing (Figure 13). If the indoor installation area is subject to freezing temperatures, the water piping must be protected by insulation. The water supply pressure should not exceed 80 psi. If this occurs, a pressure reducing valve with a bypass [...]
-
Página 16
16 TEMPERA TURE AND PRESSURE (T&P) RELIEF V AL VE (OPTIONAL TOP T&P RELIEF V AL VE NOT SHOWN) DRAIN LINE 3/4” ID MINIMUM DRAIN 1” MINIMUM 6” MAXIMUM AIR GAP MET AL DRAIN P AN DISCHARGE PIPE (DO NOT CAP OR PLUG) MASSACHUSETTS: INST ALL A V ACUUM RELIEF IN COLD W ATER LINE PER SECTION 19 MGL 142. COLD W ATER INLET V AL VE (SHUT -OFF VAL[...]
-
Página 17
17 valve or ha ve any reducing co upling installed in th e discharge line. • Must not be c apped, blocked, plugged or contain any valve be t ween the relief valv e and the end of t he dis- char ge l ine. • Must ter minate a max imum of six inches ab ove a floo r drain or exter nal to the building. • Must be c apable of withst anding 250 °F ([...]
-
Página 18
18 • Be sure to follow the manual(s ) shipped with the air handler system. • This water heater is not to be used as a replacement for an existing boiler installation. • Do not use with piping t hat has been treated wit h chromates, b oiler seal or other c hemicals and do not add any chemicals to the water heater piping. • If the spac e heat[...]
-
Página 19
19 □ F resh air ope nings sized cor rec tly with c onsider ation given to the blocking ef fec t of louvers and grilles. □ Duct wor k is the same c ross - secti onal area as the openings. V ent Pipe System Check for proper drafting at the water heater draft hood. Refer to the “Checking the Draft” section of this manual for the test procedure[...]
-
Página 20
20 W ARNING Explosion Hazard Replace view port if glass is missing or damaged. Failure to do so can result in death, explosion or fire. Ligh ti ng In st r uc t ion s Read and understand these directions thoroughly before attempting to light or re-light the pilot. Make sure the view port is not missing or damaged. (See Figure 23) Make sure the tank [...]
-
Página 21
21 M ATCH RELIEF OPENIN G DRAFT HOOD FIGU RE 17 . If the flame flutters or is blown out, combustion products are escaping from the relief opening. If this occurs, do not operate the water heater until proper adjustments or repairs are made to the vent pipe system and/or air supply requirements. FOR YOUR SAFETY READ BEFORE LIGHTING TO TURN OFF GAS T[...]
-
Página 22
22 Burner Flames Inspect the burner flames through the viewport and compare them to the drawings in Figure 18. A properly operating burner should produce a soft blue flame. Blue tips with yellow inner cones are satisfactory . The tips of the flame may have a slight yellow tint. The flame should not be all yellow or have a sharp blue-orange color . [...]
-
Página 23
23 from water damage resulting from normal condensation production, a leaking tank or piping connections. Refer to the “Location Requirements” section. W ater Heater Sounds During the normal operation of the water heater , sounds or noises may be heard. These noises are common and may result from the following: 1 . Nor mal expansion and c ontra[...]
-
Página 24
24 Anode Rod/W ater Odor Each water heater contains at least one anode rod, which will slowly deplete while protecting the glass-lined tank from corrosion and prolonging the life of the water heater . Once the anode is depleted, the tank will start to corrode, eventually developing a leak. Certain water conditions will cause a reaction between this[...]
-
Página 25
25 properly . T o prevent water damage, the valve must be properly connected to a discharge line which terminates at an adequate drain. Standing clear of the outlet (discharged water may be hot), slowly lift and release the lever handle on the temperature and pressure relief valve to allow the valve to operate freely and return to its closed positi[...]
-
Página 26
26 2. Chec k the bur ner to see if it is dir t y or c logge d. The burner may be cleaned with soap and hot water (Figure 24 ). BURNER (BOTTOM VIEW) SCREWS PILOT ASSEMBL Y (BOTTOM VIEW) FIGU RE 24. Replacing the Thermocouple 1 . Remov e the manifold/ bur ner assembly as directed previously . 2. Lift the retainer c lip strai ght up from th e back of [...]
-
Página 27
27 10. Reposition the t wo piece wire c onnector in t he manifold door opening and sec ure it with the retainer c lip. 1 1 . Carefully bend the new pilot tube and thermoc ouple to match the bend of the manifo ld tube. NOTE : W hen bending DO NOT crimp or c rease the pilot tube or therm oc ouple. (Figure 25 ) 1 2. Before you proc eed to th e next st[...]
-
Página 28
28 tight in the gas control valve/thermostat. Finally , start the thermocouple nut and turn it all the way in by hand. An additional quarter turn with a 3/8” open-end wrench will then be sufficient to seat the lockwasher . When you are finished, connect the two wire leads that go to the thermal switch. 7 . Reconnec t the igniter wire. 8. T urn ga[...]
-
Página 29
29 Replacing the Gas V alve: 1 . T o replace t he gas co ntrol valve/ther most at, reassemble in reverse order . When replacing th e gas contro l valve/ thermost at, thread a c or rectly sized pipe into the inlet and use it to turn the gas valve ( clo ck wi se. ) DO NO T OVER TIG HTEN or damage may result. NOTE: Use an appro ved TEFL ON ® tape or [...]
-
Página 30
30 PROBLEM POSSIBLE CAUSE(S) CORRECTIVE ACTION HIGH OPERA TION COSTS 1 . Ther most at set too high 2. Sed iment or lime in tank 3. W ater heater too small for j ob 4. W rong piping c onnections 5. Leaking faucets 6. Gas leaks 7 . Wasted hot water 8. Long runs of exposed piping 9. Hot water piping in e xpo sed wall 1 . Set temperature dial to lower [...]
-
Página 31
31 PILOT LIGHT TROUBLESHOOTING FLOWCHART Has the thermal switch tripped? NO Check for insufficient combustion air . Are there openings for make-up air to enter the room? Are the openings of sufficient size? See “Combustion Air Supply and Ventilation” section in this manual for requirements. Is there a furnace/air handler in the same room as the[...]
-
Página 32
32 REP AIR P ARTS ILLUSTRA TION *Pictured on next page. When ordering repair parts always give the following information: 1. Model, serial, and product number 2. T ype of gas 3. Item number 4. Parts description Repair Parts List LEGEND Special anode rod (see Anode Rod/W ater Odor section) T emperature and Pressure Relief V alve is required, but may[...]
-
Página 33
33 Listed Parts Kits and Illustrations It e m 12: Pi l ot / Pilot T ube Assembly kit, which c ontains t he pilot assembly , ther moc ouple, igniter electro de and retainer clip (Natural G as ) Ite m 13: Pilot / Pilot T ube Ass emb ly kit, which co ntains the pilot assembly , ther moc ouple, igniter elect rode and retainer c lip (L.P . Gas ) Item 1 [...]
-
Página 34
34 NOTES[...]
-
Página 35
35 THIS W ARRANTY IS APPLICABLE T O THE ORIGINAL OWNER ONL Y , in accordance with the warranty terms and conditions specified below . State W ater Heaters (the warrantor) will furnish the ORIGINAL OWNER, 1) a replacement State water heater of equivalent size and current model if the glass-lined tank in this water heater leaks and, 2) a replacement [...]
-
Página 36
36 LIMIT A TION ON IMPLIED W ARRANTIES Implied warranties, including any warranty of merchantability imposed on the sale of this heater under state law are limited to one year duration for the heater or any of its parts. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. CLAIM [...]