Sun Microsystems SUN NETRA CP3000 manual
- Consulta online o descarga el manual de instrucciones
- 72 páginas
- 1.77 mb
Ir a la página of
manuales de instrucciones parecidos
-
Computer Drive
Sun Microsystems Netra CP32x0
66 páginas 2.09 mb -
Computer Drive
Sun Microsystems StorageTek 96257
118 páginas 2.01 mb -
Computer Drive
Sun Microsystems 5210 NAS
100 páginas 0.97 mb -
Computer Drive
Sun Microsystems X4150 Server
80 páginas 1.77 mb -
Computer Drive
Sun Microsystems Sun StorageTek 5800
136 páginas 1.05 mb -
Computer Drive
Sun Microsystems StorageTek HP LTO4
38 páginas 1 mb -
Computer Drive
Sun Microsystems HP LTO4
38 páginas 0.96 mb -
Computer Drive
Sun Microsystems STOREDGE A5000
2 páginas 0.09 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Sun Microsystems SUN NETRA CP3000. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Sun Microsystems SUN NETRA CP3000 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Sun Microsystems SUN NETRA CP3000 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Sun Microsystems SUN NETRA CP3000, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Sun Microsystems SUN NETRA CP3000 debe contener:
- información acerca de las especificaciones técnicas del dispositivo Sun Microsystems SUN NETRA CP3000
- nombre de fabricante y año de fabricación del dispositivo Sun Microsystems SUN NETRA CP3000
- condiciones de uso, configuración y mantenimiento del dispositivo Sun Microsystems SUN NETRA CP3000
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Sun Microsystems SUN NETRA CP3000 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Sun Microsystems SUN NETRA CP3000 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Sun Microsystems en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Sun Microsystems SUN NETRA CP3000, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Sun Microsystems SUN NETRA CP3000, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Sun Microsystems SUN NETRA CP3000. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
Sun Microsystems, Inc. www .sun.com Submit comments about this document at: http://www.sun.com/hwdocs/feedback Sun Netr a ™ CP3000 Adv anced Mezzanine Card PCIe Hard Dr iv e and SAS Controller User’ s Guide f or the AMC .1-HDD SAS Disk P ar t No . 820-7175-11 March 2010, Revision A[...]
-
Página 2
Please Recycle Copyright © 2010 Sun Microsystems, Inc., 4150 Network Cir cle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun Microsystems, Inc. has intellectual pr operty rights relating to technology embodied in the pr oduct that is described in this document. In particular , and without limitation, these intellectual property rig[...]
-
Página 3
iii Contents Preface vii 1. Getting Started 1–1 1.1 System Requirements 1–2 1.1.1 Operating Systems Compatibility 1–2 1.1.2 Chassis Compatibility 1–2 1.1.3 Blade Server Compatibility 1–2 1.1.4 Electrical and Environmental 1–3 1.2 Unpacking 1–3 1.3 Handling AMCs 1–4 1.4 AMC Faceplate 1–5 1.5 AMC LEDs 1–6 1.6 Removing and Installi[...]
-
Página 4
iv Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 1.7 Enabling and Disabling SAS Ports 1–18 ▼ T o Enable AMC Port 2 (Driven by Port 1 of SAS Controller) 18 ▼ T o Enable AMC Port 3 (Driven by Port 2 of SAS Controller) 18 ▼ T o Disable AMC Port 2 (Driven by Port 1 of SAS Controller) 1[...]
-
Página 5
Contents v 4. Conf iguring the AMC 4–1 4.1 Configuration T ools 4–2 4.2 Boot BIOS Utility 4–2 4.2.1 Features and Conf igurations 4–3 4.2.2 Launching the Boot BIOS Utility 4–3 4.3 OpenBoot BIOS 4–5 4.4 Extensible Firmware Interface (EFI) BIOS 4–6 4.5 Enabling and Disabling Channel Ports 4–6 A. Connectors and Ports A–1 A.1 Connector[...]
-
Página 6
vi Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 C.4.1 EN 55022 Emissions C–4 C.4.2 EN 55024 Immunity C–4 C.5 Regulatory Information C–5 C.5.1 FCC (USA) C–5 C.5.2 Industry Canada (Canada) C–5 Index Index–1[...]
-
Página 7
vii Pr eface The Netra™ CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User ’ s Guide describes the installation and configuration of the Sun Netra CP3000 AMC.1-HDD SAS disk. This guide also includes information about software, environment specif ications, connectors, and certifications. T ypographic Conventions Note – Char[...]
-
Página 8
viii Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 Related Documentation The following table lists the documentation for the AMC.1-HDD SAS disk. The online documentation is available at: http://docs.sun.com/app/docs/prod/cp3000.pcie#hic Thir d-Party W eb Sites Sun is not responsible for th[...]
-
Página 9
Preface ix Sun W elcomes Y our Comments Sun is interested in impr oving its documentation and welcomes your comments and suggestions. Y ou can submit your comments by going to: http://www.sun.com/hwdocs/feedback Please include the title and part number of your document with your feedback: Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and[...]
-
Página 10
x Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010[...]
-
Página 11
1-1 CHAPTER 1 Getting Started This chapter provides information and pr ocedures needed to install and make the Sun Netra CP3000 AMC.1-HDD SAS disk operational. This chapter should be read before unpacking and installing the AMC. In addition to this chapter , r efer to the following safety document: Important Safety Information for Sun Hardware Syst[...]
-
Página 12
1-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 1.1 System Requir ements The following sections briefly describe the minimum system r equirements and the configurable featur es. Links are pr ovided to other chapters and appendixes containing more detailed information. 1.1.1 Operating Sys[...]
-
Página 13
Chapter 1 Getting Star ted 1-3 1.1.4 Electrical and Envir onmental See Appendix B for electrical and environmental requir ements. Caution – None of the integrated chips junction temperature should exceed 125˚C. The AMC requir es air f low to meet this requir ement. T esting should be done in the shelf to find the quantity of air f low needed. Th[...]
-
Página 14
1-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 1.3 Handling AMCs Caution – The system is sensitive to static electricity . T o pr event damage to the assembly , always connect an antistatic wrist strap between you and the system. A void touching areas of integrated circuitry . Static [...]
-
Página 15
Chapter 1 Getting Star ted 1-5 ■ Do not use an oscilloscope probe on the components. The soldered pins ar e easily damaged or shorted by the probe point. ■ T ransport an AMC in an antistatic bag. 1.4 AMC Faceplate The following shows the faceplate of the Sun Netra CP3000 AMC.1-HDD SAS disk. FIGURE 1-1 AMC.1-HDD SAS Disk Faceplate Note – The A[...]
-
Página 16
1-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 1.5 AMC LEDs The following tables give status information for all of the LEDs on the AMC. T ABLE 1- 1 describes the LEDs defined by A TCA to monitor boar d status. T ABLE 1-2 describes in detail the different hot-swap BLUE LED states. T ABL[...]
-
Página 17
Chapter 1 Getting Star ted 1-7 Note – An AMC should be hot-swapped only when the LED is solid blue. T ABLE 1-2 Hot-Swap BLUE LED States Order Visible State State Description 1 Solid M1 FRU Inactive The Intelligent Platform Management Interface (IPMI) microcontr oller is booted, but the payload is not. The bottom latch is not fully closed or the a[...]
-
Página 18
1-8 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 1.6 Removing and Installing AMCs This section describes how to remove and install AMCs. The AMC.1-HDD SAS disk can be installed into an A TCA shelf (chassis) with sites that support AMC.1 PCI Express signaling. The site height must pr operl[...]
-
Página 19
Chapter 1 Getting Star ted 1-9 Note – Depending on how the Shelf controls deactivation, the Shelf might not initiate deactivation when you disengage the ejector latch. If so, either configure the Shelf to allow deactivation via latch opening or deactivate by other methods. 4. For the AMC, initiate the hot-swap deactivation sequence by pulling the[...]
-
Página 20
1-10 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 FIGURE 1-2 Deactivating the AMC Figure Legend 1 Fully In (IN) When IN, the module communicates to the shelf manager that the module is not in the hot-s wap state , and the shelf manager communicates with the MMC . This position is for norm[...]
-
Página 21
Chapter 1 Getting Star ted 1-11 7. Remove the AMC. FIGURE 1-3 Removing the AMC 8. Replace the AMC with another AMC ( FIGURE 1-7 ) or install a f iller panel. Note – Be sure to follow handling instructions. See Section 1.3, “Handling AMCs” on page 1-4 .[...]
-
Página 22
1-12 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 Caution – Failure to f ill all slots with AMCs or cover with filler panels can negatively impact the cooling of the system. 1.6.2 Removing a Blade Server and AMC Following are the instructions for r emoving a blade server and installed A[...]
-
Página 23
Chapter 1 Getting Star ted 1-13 Note – Depending on how the Shelf controls deactivation, the Shelf might not initiate deactivation when you disengage the ejector latch. If so, either configure the Shelf to allow deactivation via latch opening or deactivate by other methods. 3. Disconnect all cables connected to the switch. 4. Loosen the two board[...]
-
Página 24
1-14 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 3. Obtain the AMC card from the ship kit. Note – Be sure to follow unpacking and handling instructions. See Section 1.2, “Unpacking” on page 1-3 and Section 1.3, “Handling AMCs” on page 1-4 . FIGURE 1-5 Sample T op V iew Note –[...]
-
Página 25
Chapter 1 Getting Star ted 1-15 FIGURE 1-6 Opening the Injector/Ejector Latch Figure Legend 1 Fully In (IN) When IN, the module communicates to the shelf manager that the module is not in the hot-s wap state , and the shelf manager communicates with the MMC . This position is for normal operation. 2 Half W a y (HW) When in the HW position, the hot-[...]
-
Página 26
1-16 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 6. Carefully align the edges of the AMC with the guides in the appropriate site. It might be helpful to look into the enclosure to verify correct alignment of the rails in the guides. Caution – Do not force the AMC into the site. If it d[...]
-
Página 27
Chapter 1 Getting Star ted 1-17 FIGURE 1-7 Inserting the AMC Into a Blade Server 8. Push the ejector latch in fully . If system power is on and AMC is installed properly , the AMC board Hot-Swap LED lights up. The Hot-Swap LED blinks for several seconds, then goes off. If the Hot-Swap LED does not go of f after several seconds, push f irmly on the [...]
-
Página 28
1-18 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 Caution – Failure to f ill all slots with AMCs or cover with filler panels can negatively impact the cooling of the system. 9. Power on the system, if necessary . Refer to your system manual for instructions on correctly powering on the [...]
-
Página 29
Chapter 1 Getting Star ted 1-19 Note – This utility has many other uses and adjustable values. Parameter adjustments are permanently committed to flash memory , and affect futur e behavior of the AMC. Only advanced users who fully understand the technical implications should modify parameters. A full description of parameters and functions is in [...]
-
Página 30
1-20 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010[...]
-
Página 31
2-1 CHAPTER 2 Overview This chapter introduces the key featur es of the AMC. This chapter includes a product def inition, a list of product features, and functional block diagrams with brief descriptions. This chapter can be used to compare the features of the AMC against the needs of a specific application. This chapter contains the following topi[...]
-
Página 32
2-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 2.1 Featur es Part of Sun’s A TCA platform, the Sun Netra CP3000 AMC.1-HDD SAS disk complies with PICMG 3.0 AdvancedTCA Specification R2.0 ECN002 and the following specifications: ■ PICMG AMC.0 Rev . 2.0 ■ AMC.1 Revision 1, PCI Expres[...]
-
Página 33
Chapter 2 Overview 2-3 ■ Support for SA T A, as defined in the Serial A T A Specification, version 1.0a. 2.2 Key Components The following figur e and sections describe key components of the Sun Netra CP3000 AMC.1-HDD SAS disk. FIGURE 2-1 T op-Level AMC Layout 2.2.1 Har d Drive Disk The Sun Netra CP3000 AMC.1-HDD SAS disk provides a single SAS har[...]
-
Página 34
2-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 2.2.3 SAS Contr oller The AMC.1-HDD SAS disk incorporates a PCIe-to-SAS host controller manufactured by LSI Corporation, device model LSI-SAS1064E. The controller pr ovides host access to SAS and SA T A disks. The controller features four l[...]
-
Página 35
Chapter 2 Overview 2-5 ■ e-Keying as described in the AMC.0 specification ■ FRU information ■ LED indicators for hot-swap and OOS (out of service) 2.2.6 Port Connectors The AMC includes connectors to communicate with the host board and take its interfaces outside the A TCA chassis. Refer to Appendix A for complete connector descriptions and p[...]
-
Página 36
2-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 Figure Legend Indicator Color State Description and Function 1 OOS Red On Out of Ser vice: f ault set by shelf manager , or 12V payload pow er not detected. Off No module f ault. 12V pa yload pow er is being supplied to board. 2 OK Green On[...]
-
Página 37
Chapter 2 Overview 2-7 2.4 Functional Diagram FIGURE 2-3 AMC SAS-HDD Functional Block Diagram 2.5 T echnical Support and W arranty If you have any technical questions or support issues that are not addressed in the Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Contr oller documentation set or on the web site, contact your local S[...]
-
Página 38
2-8 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 When you call Sun Services, indicate if the Sun Netra CP3000 AMC.1-HDD SAS disk was purchased separately and is not associated with a system. Have the proper AMC identification information r eady . Be prepared to give the r epr esentative t[...]
-
Página 39
Chapter 2 Overview 2-9 FIGURE 2-4 Sun Netra CP3000 AMC.1-HDD SAS disk Barcode Labeling Figure Legend 1 Final Assembly Number: • Assembly process label, wher e xxx denotes disk drive capacity • Rzz = Assembly Revision (Refer to Bill Of Material) wher e zz is a numeric revision 2 Sub-Assembly Number: • P/N = sub assembly Part Number 600-05101x [...]
-
Página 40
2-10 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 2.7 Disposal The AMC might contain materials that require r egulation upon disposal. Please dispose of this product in accor dance with local rules and r egulations. For disposal or recycling information, please contact your local authorit[...]
-
Página 41
3-1 CHAPTER 3 Managing the AMC This chapter describes the AMC management software. The Sun Netra CP3000 AMC.1-HDD SAS disk includes an IPMI-based Module Management Controller (MMC) that meets all r equirements set out in the PICMG AMC.0 specification. The MMC allows detection of the module by the carrier board and manages communication between the [...]
-
Página 42
3-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 3.1 Monitoring and Contr ol Functions The MMC is responsible for communicating module status information to the carrier board, and also has some contr ol at the module level. The 10GbE local PHY is held in reset until the AMC Carrier IPMI u[...]
-
Página 43
Chapter 3 Managing the AMC 3-3 Get Device SDR 29.3 S/E 21h Mandatory Reserve Device SDR Repository 29.4 S/E 22h Mandatory Get Sensor Reading Factors 29.5 S/E 23h Optional Set Sensor Hysteresis 29.6 S/E 24h Optional Get Sensor Hysteresis 29.7 S/E 25h Optional Set Sensor Threshold 29.8 S/E 26h Optional Get Sensor Threshold 29.9 S/E 27h Optional Set S[...]
-
Página 44
3-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 3.3 FRU Information Board information such as serial number , date of manufacture, OEM name, part number , and so on is r etrievable from the FRU EEPROM integrated into the MMC. FRU information stored onboar d the AMC.1-HDD SAS disk complie[...]
-
Página 45
Chapter 3 Managing the AMC 3-5 3.4 Sensors The AMC.1-HDD SAS disk module management is connected to sensors monitoring key board voltages and temperatur es. Data recor ds from the following sensors ar e accessible using IPMI commands: ■ Hot-swap ■ +12V payload power ■ +3.3V management power ■ Board and inlet temperatur e ■ +1.2V onboard v[...]
-
Página 46
3-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 3.5 Firmwar e and Software Upgrades For up-to-date instructions on upgrading the firmwar e and software, r efer to the following documentation: ■ Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller Product Notes (8[...]
-
Página 47
4-1 CHAPTER 4 Conf iguring the AMC This chapter describes how to configur e the AMC using the SAS Boot BIOS Configuration Utility , the OpenBoot ™ BIOS, and the Extensible Firmware Interface (EFI) Boot Services Driver . This chapter contains the following topics: ■ Section 4.1, “Configuration T ools” on page 4-2 ■ Section 4.2, “Boot BIO[...]
-
Página 48
4-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 4.1 Conf iguration T ools The configuration tools ar e preloaded on a f lash ROM device embedded on the AMC. A MicroTCA or host carrier CPU can r ead the code to facilitate booting from SAS drives. The BIOS contains an embedded configuratio[...]
-
Página 49
Chapter 4 Configuring the AMC 4-3 4.2.1 Featur es and Conf igurations The Boot BIOS supports the following: ■ Using multiple AMC.1 SAS modules ■ Applying global properties stored in f lash ■ Selecting and configur e up to 256 adapters ■ Automatic INT13 drive mapping for SAS drives ■ SAS topology discovery , including expander traversal ?[...]
-
Página 50
4-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 FIGURE 4-1 Boot BIOS Main Menu The menu displays a scrolling list of all the AMC SAS modules visible in the system, with PCI Express (PCIe) identif ication information. 3. Use the arrow keys to highlight the AMC module you want to conf igur[...]
-
Página 51
Chapter 4 Configuring the AMC 4-5 FIGURE 4-2 Adapter Properties Menu 5. Using the arrow keys, select the item of interest. 6. Press ENTER to display the next screen. 4.3 OpenBoot BIOS For information about the OpenBoot BIOS, refer to the Sun Solaris OS and SP ARC documentation. The documentation is available at the following site: http://www.sun.co[...]
-
Página 52
4-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 4.4 Extensible Firmwar e Interface (EFI) BIOS The AMC.1-HDD SAS disk includes an EFI boot services driver for use with A TCA blades that feature Intel® IA64 pr ocessors. Additional information is available at http://www.lsi.com . 4.5 Enabl[...]
-
Página 53
A-1 APPENDIX A Connectors and Ports This appendix describes the connectors and ports you can use to communicate with the host board and application-specif ic devices. A brief description of each connector and port is given, and a detailed description and pinout given for each connector . This appendix contains the following topics: ■ Section A.1,[...]
-
Página 54
A-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 A.1 Connector Locations and Assignments This module is AMC.1 and AMC.3 compliant and can use ports 2 and 3, as defined in the AMC.3 specification. A.2 Connector Pinouts The AMC.1-HDD SAS disk includes an AMC connector , which conforms to th[...]
-
Página 55
Appendix A Connectors and P or ts A-3 9 12V 54 'PCIe_RX1_N' 99 No Connect 144 No Connect 10 GND 55 GND 100 No Connect 145 No Connect 1 1 No Connect 56 'IPMI_SCL_L' 101 GND 146 GND 12 No Connect 57 12V 102 No Connect 147 No Connect 13 GND 58 GND 103 No Connect 148 No Connect 14 No Connect 59 'PCIe_TX2_P' 104 GND 149 GND[...]
-
Página 56
A-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 A.3 SAS Contr oller Ports The AMC.1-HDD SAS disk incorporates four dedicated SAS controller ports as follows. These SAS ports are shipped with PHY’s disabled and are not driving AMC ports 2 and 3. This default configura- tion avoids incom[...]
-
Página 57
Appendix A Connectors and P or ts A-5 A.4 e-Keying Ports The AMC.1-HDD SAS disk connects up to two SAS ports on the AMC connector . These ports are def ined by the AMC.3 specification for serial storage. The module designates four PCI Express ports, per AMC.1 specif ication. The link type and link type extension are def ined in the following table.[...]
-
Página 58
A-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010[...]
-
Página 59
B-1 APPENDIX B Envir onment Specif ications This appendix describes the electrical, environmental, and mechanical specifications. It includes illustrations of the board dimensions. This appendix contains the following topics: ■ Section B.1, “Electrical and Environmental” on page B-2 ■ Section B.2, “Reliability” on page B-4 ■ Section B[...]
-
Página 60
B-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 B.1 Electrical and Envir onmental The following sections provide tables and illustrations showing the electrical and environmental specif ications. B.1.1 Electrical The AMC.1-HDD SAS disk shall consume no more than the following fr om the s[...]
-
Página 61
Appendix B Environment Specifications B-3 V ibration Operating 1 G (20 to 300 Hz) Nonoperating 5 G (20 to 300 Hz) Shock Operating 100 G/1ms duration Nonoperating 400 G/1ms duration Altitude Operating –1,000 to +10,000 feet Nonoperating –1,000 to +40,000 feet Performance RPM 10,025 rpm Seek time avg Read/write 4.5 m/s (typical) Seek time max Rea[...]
-
Página 62
B-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 B.1.3 Absolute Maximum Ratings The following values are str ess ratings only . Do not operate at these maximums. See Section B.1.4, “Normal Operating Ranges” on page B-4 for normal operating conditions. B.1.4 Normal Operating Ranges *Th[...]
-
Página 63
Appendix B Environment Specifications B-5 B.3 Mechanical This section includes the mechanical specifications for dimensions and weight. The AMC.1-HDD SAS disk meets the PICMG 3.0 AdvancedTCA Specification R2.0 ECN002 and AMC.0 R2.0 for all mechanical parameters. B.3.1 Boar d Dimensions and W eight The AMC.1-HDD SAS disk is 181.5 mm by 73.5mm and co[...]
-
Página 64
B-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010[...]
-
Página 65
C-1 APPENDIX C Agency Certif ications This appendix lists standards agencies and the certif ications related to the Sun Netra CP3000 AMC.1-HDD SAS disk. This product was tested in an EMC-compliant chassis and meets the r equirements for EN55022 Class A equipment. Compliance was achieved under the following conditions: ■ Conductive chassis rails c[...]
-
Página 66
C-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 C.1 CE Certif ication The Sun Netra CP3000 AMC.1-HDD SAS disk meets the intent of Directive 89/336/EEC for Electromagnetic Compatibility [EN55024:1998, EN55022:2006] and Low-V oltage Directive 73/23/EEC for Product Safety [EN60950-1:2001]. [...]
-
Página 67
Appendix C Agency Cer tifications C-3 C.3 Safety ■ UL/cUL 60950--1 Safety for Information T echnology Equipment (UL File #E138926) ■ EN/IEC 60950-1:2001, 1 ST ED CB/CCA –scheme, Safety for Information T echnology Equipment (TUV CB certificate and report) The following group and/or national deviations were consider ed: ■ CENELEC Common Modif[...]
-
Página 68
C-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 C.4 Emissions T est Regulations ■ FCC Part 15, Subpart B Class A Commercial Equipment ■ Industry Canada ICES-003:2004 Class A Commercial Equipment ■ CISPR 22/EN 55022:2006 Class A Radiated, Power line Conducted ■ VCCI, Japanese V -3[...]
-
Página 69
Appendix C Agency Cer tifications C-5 C.5 Regulatory Information Caution – If you make any modification to the AMC not expr essly approved by Sun, you could void your warranty and/or regulatory authority to operate the component. C.5.1 FCC (USA) This product has been tested and found to comply with the limits for a Class A digital device pursuant[...]
-
Página 70
C-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 1. Ce dispositif peut ne pas causer l'interférence nocive. 2. Ce dispositif doit accepter n'importe quelle interférence reçue, y compris l'interférence qui peut causer l'opération peu désirée.[...]
-
Página 71
Index-1 Index Numerics 10GbE local PHY, 3-2 A absolute maximum ratings, B-4 AMC flexing, preventing, 1-4 antistatic bag, 1-3 B board status, 1-6 board voltages, monitoring, 2-4 C cable management bracket lowering, 1-12 cable management bracket, lowering, 1-12 certification, C-2 comments, about this book, ix connector locations, A-2 D deactivating[...]
-
Página 72
Index-2 Sun Netra CP3000 Adv anced Mezzanine Card PCIe Hard Drive and SAS Controller User’ s Guide • March M MAC address label, 2-8 management voltage, B-4 maximum power consumption, B-4 Module Management Controller (MMC), 2-4, 3-1 module status, 3-2 N NEBS/ETSI, C-2 nominal operating voltage, B-4 noncondensing relative humidity, B-4 normal ope[...]