Toro Plus Series Satellite manual
- Consulta online o descarga el manual de instrucciones
- 19 páginas
- 0.4 mb
Ir a la página of
manuales de instrucciones parecidos
-
Lawn mower
Toro 02604 - HoverPro 500
20 páginas 1.25 mb -
Automobile
Toro 5400-D
52 páginas 3.95 mb -
Utility Vehicle
Toro 7370
5 páginas 0.21 mb -
Weather Radio
Toro 53769
12 páginas 0.7 mb -
Sprinkler
Toro FLX34
12 páginas 1.66 mb -
Lawn Mower
Toro 14AP80RP544
60 páginas 6.67 mb -
Paint Sprayer
Toro 41229
159 páginas 8.36 mb -
Snow Blower
Toro 38584
20 páginas 0.78 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Toro Plus Series Satellite. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Toro Plus Series Satellite o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Toro Plus Series Satellite se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Toro Plus Series Satellite, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Toro Plus Series Satellite debe contener:
- información acerca de las especificaciones técnicas del dispositivo Toro Plus Series Satellite
- nombre de fabricante y año de fabricación del dispositivo Toro Plus Series Satellite
- condiciones de uso, configuración y mantenimiento del dispositivo Toro Plus Series Satellite
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Toro Plus Series Satellite no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Toro Plus Series Satellite y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Toro en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Toro Plus Series Satellite, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Toro Plus Series Satellite, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Toro Plus Series Satellite. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
Controller Components ................................................. 2 Selecting Control Options ............................................ 3 Before Programming the Controller… ..........................4 About The Controller’s Memory ................................... 4 Set Satellite Operating Mode .......................................[...]
-
Página 2
CONTROLLER COMPONENTS 2 Address % Adjust Time/Day Week 1 Central Stand Alone Off Cycle Syringe Multi Manual Start Times Active Days Run Times ENTER START EXIT STOP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Week 2 R LTC TM Tu Programs Plus 1. Control Panel Assembly 2. Pump/Common Output Module 3. Power Indicator Lamp – (5V) Control Functions 4. 8-Station O[...]
-
Página 3
Selecting Control Options A set of eight DIP switches, located beneath the upper left corner of the control panel (as illustrated below) is provided for the selection of optional control characteristics. Power to the controller must be turned Off and the control panel removed from the cabinet in order to make switch position changes. When power is [...]
-
Página 4
Before Programming the Controller … Please note the following important information before programming the Network LTC Plus con- troller for the first time. Although the controller is quite easy to program, it does have some pro- gramming and operating characteristics which will be helpful to know before starting. • *If power is interrupted to [...]
-
Página 5
Set Current Time and Day Synchronizing the controller's clock with the current time and day is an important first step in the programming procedure. The timed events for all watering programs (when the satellite is in the Satellite Mode) are based on the settings you will make here. Use the following procedure to set the current time and day: [...]
-
Página 6
Set Program Start Time(s) This procedure will determine when each program will start during a 24 hour period. Note the following characteristics: • Each program can have from 1 to 12 start times. • Start times can be set to the minute. • Program operation can be prevented for any of the 12 start times by selecting OFF (no start time). • Whe[...]
-
Página 7
Set Active Day W atering Schedules The active watering days for each program can be chosen using a Calendar schedule or an Interval schedule. The Calendar schedule enables active days to be selected within a 14-day (two week) cycle. The Interval Schedule enables active days to be selected by a specific interval, such as every day, every-other day, [...]
-
Página 8
Interval Schedule Scheduling active days by Interval enables a program to operate on a specific routine such as, every other day, or every fourth day, without regard to actual calendar days. The Interval schedule consists of two programmable numbers: The Interval Reference and the Interval Day. The Interval Reference number (01 – 29) determines h[...]
-
Página 9
Set Program Repeat and Soak This is an optional programming feature which enables a program to repeat its operating cycle from 0 – 3 times (in addition to its initial cycle). A soak-in period from 0 – 59 minutes is placed between repeat cycles. 1. Press as needed to select the Program indicator. 2. Press or until the desired program number (1 ?[...]
-
Página 10
Program Operation Pause and Cancel An operating program can be paused or canceled at any time as needed. The pause feature temporarily suspends program operation for up to 10 minutes. When operation resumes, the program continues from the point of interruption without loosing station run time. Use the cancel feature to terminate the program operati[...]
-
Página 11
Syringe Mode The Syringe mode enables all stations with a programmed run time in a selected program to be operated for a short, temporary run time (syringe). The amount of run time for the syringe operation can be set from 1 – 30 minutes or by a percentage of programmed station run time from 10% – 99%. To syringe all stations from 1 – 30 minu[...]
-
Página 12
Multi-Manual Mode Up to six selected stations can be operated at the same time using Multi-Manual mode. A temporary run time from 1 to 59 minutes is given to each station for this operation. Caution: Prior to Multi-Manual operation, ensure that combined current draw of all stations operating at the same time (including pump relay) does not exceed 3[...]
-
Página 13
Set Satellite Address The LTC satellite requires a unique address for identification by the central LCM within the network system. The address consists of a group number (1 – 50) and satellite number (1 – 500). A combination of up to 500 satellites may be defined. Satellites may only be assigned to one group. However, the same satellite number [...]
-
Página 14
Reviewing Program Information To review the current operating information entered for any program, use the procedure below. If you need to make changes to any portion of a program or the Time/Day setting, refer to the appropriate procedure in the programming section of this manual. 1. Press to select the Program number indicator. 2. Press or as nee[...]
-
Página 15
Radio Calibration T est The radio calibration test enables the LTC to generate three different radio test patterns for use in radio network communications setup. If a radio is not connected, no indication is seen on the TM. The test patterns can be monitored by connecting an oscilloscope or headphones to the modem 2-wire connector. To Perform Radio[...]
-
Página 16
T roubleshooting If you experience a controller problem, check the programming for a possible programming error and the list of problems and solutions listed below. If the problem continues, contact your local Toro distributor for assistance. Lithium Battery installation (optional) An optional 3.9V lithium battery (P/N 363-2200) can be installed to[...]
-
Página 17
Manual Output Switch Operation A 3-position switch is provided on the Pump/Com module for additional control of the pump relay circuit. In addition, the optional station terminal modules with optional control switches have one switch for each station output. The three switch positions control the circuits as follows: On – Manually activates the c[...]
-
Página 18
Program Data Reference Form Program Number_____ Date_________ Station Location 1 ___________________ 17 ___________________ 33 ____________________ 49 ____________________ 2 ___________________ 18 ___________________ 34 ____________________ 50 ____________________ 3 ___________________ 19 ___________________ 35 ____________________ 51 _____________[...]
-
Página 19
User's Guide Network L TC TM Plus Series Satellite TM R[...]