Travis Industries DVS Insert EF II manual
- Consulta online o descarga el manual de instrucciones
- 42 páginas
- 0.37 mb
Ir a la página of
manuales de instrucciones parecidos
-
Indoor Fireplace
Travis Industries DVS Insert EF II
42 páginas 0.37 mb -
Indoor Fireplace
Travis Industries Flush Wood Insert
34 páginas 1.33 mb -
Indoor Fireplace
Travis Industries Space Saver IPI Fireplace 564
30 páginas 4.99 mb -
Indoor Fireplace
Travis Industries 4915
1 páginas 0.37 mb -
Indoor Fireplace
Travis Industries DVL Insert EF II
44 páginas 3.28 mb -
Indoor Fireplace
Travis Industries Fireplace Manual 21 DV Fireplace
50 páginas 0.8 mb -
Indoor Fireplace
Travis Industries Revolution 36CF
48 páginas 2.12 mb -
Indoor Fireplace
Travis Industries GreenSmart Fireplace 564 SS
30 páginas 1.47 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Travis Industries DVS Insert EF II. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Travis Industries DVS Insert EF II o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Travis Industries DVS Insert EF II se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Travis Industries DVS Insert EF II, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Travis Industries DVS Insert EF II debe contener:
- información acerca de las especificaciones técnicas del dispositivo Travis Industries DVS Insert EF II
- nombre de fabricante y año de fabricación del dispositivo Travis Industries DVS Insert EF II
- condiciones de uso, configuración y mantenimiento del dispositivo Travis Industries DVS Insert EF II
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Travis Industries DVS Insert EF II no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Travis Industries DVS Insert EF II y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Travis Industries en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Travis Industries DVS Insert EF II, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Travis Industries DVS Insert EF II, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Travis Industries DVS Insert EF II. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
D VS In s ert EF II Own e r's M an ual Featuring the Burner Tested and Listed by OMNI-Test Laboratories, Inc. Beaverton, Oregon Report # 028-F-73-5 ANSI Z21.88 • Direct Vent Fireplace Insert • Masonry or Factory Built (Metal) Wood-Burning Fireplace • Residential or Mobile Home WARNING: If the information in these instructions is not foll[...]
-
Página 2
2 Introduction © Travis Industries 4060111 100-01175 Introduction We welcome you as a new owner of a DVS Insert. In purchasing this fireplace insert you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. It is one of the finest home heaters the worl[...]
-
Página 3
Table of Contents 3 © Travis Industries 4060111 100-01175 Introduction and Important Information Introduction ......................................................2 Safety Precautions Safety Precautions ............................................4 Features & Specifications Features ..........................................................6 [...]
-
Página 4
4 Safety Precautions © Travis Industries 4060111 100-01175 IF YOU SMELL GAS: * Do not light any appliance * Extinguish any open flame * Do not touch any electrical switch or plug or unplug anything * Open windows and vacate building * Call gas supplier from neighbor's house, if not reached, call fire department This unit must be installed b y[...]
-
Página 5
Safety Precautions 5 © Travis Industries 4060111 100-01175 Do not place clothin g or other flammable items on or near the heater. Because this heater can be controlled by a thermostat there is a possibility of the heater turning on and igniting any items placed on or near it. Li g ht the heater usin g the built- in piezo igniter. Do not use matche[...]
-
Página 6
6 Features and Specifications © Travis Industries 4060111 100-01175 Features • Works During Power Outages (millivolt system) • High Efficiency • Optional Thermostat or Remote Control • Ember Fyre™ Burner for "Wood Fire" Look • Quiet Blower for Effective Heat Distribution • Convenient Operating Controls • Variable-Rate Hea[...]
-
Página 7
Installation (for qualified installers only) 7 © Travis Industries 4060111 100-01175 Installation Warnings • Failure to follow all of the requirements may result in property damage, bodily injury, or even death. • This heater must be installed by a qualified installer who has gone through a training program for the installation of direct vent [...]
-
Página 8
8 Installation (for qualified installers only) © Travis Industries 4060111 100-01175 Top Convection Deflector Install the top convection deflector as shown to the right. The deflector is shipped on top of the insert. The screws are shipped inside the owner's pack. Fireplace Requirements • Insert must be placed within a code-conforming mason[...]
-
Página 9
Installation (for qualified installers only) 9 © Travis Industries 4060111 100-01175 Factory-Built (Metal) Wood-Burning Fireplace Requirements The damper (" A ") and grate (with log set) (" B ") must be removed (see the illustration below) The smoke shelf (" C "), internal baffles (" D "), screen (" E &[...]
-
Página 10
10 Installation (for qualified installers only) © Travis Industries 4060111 100-01175 Clearances Due to the high temperature of the heater, it should be located out of traffic and away from furniture and draperies. Side Wall Combustible or Non-Combustible Mantel Combustible Top Facing Non-Combustible Facing Minimum Clearances k l m n x Sidewall to[...]
-
Página 11
Installation (for qualified installers only) 11 © Travis Industries 4060111 100-01175 Face Sizing Face Height Width Notes Rawhide 22-1/2” 32” Victorian 22-1/2” 32” Rosario 21-9/16” 32” Cambridge 21-1/2” 33” Craftsman 21-1/2” 32” Classic Arched, Artisan 22 ” 30 ” Side begins arch 3-1/2” below top - 34” radius Metropolita[...]
-
Página 12
12 Installation (for qualified installers only) © Travis Industries 4060111 100-01175 Face Mounting Brackets -- Arched, Metropolitan, Artisan Vict. Lace Faces Some Arched, Artisan, Metropolitan, and Victorian Lace Faces include old brackets that will not mount to the heater (see illustration below). For these faces, make sure to use the new mounti[...]
-
Página 13
Installation (for qualified installers only) 13 © Travis Industries 4060111 100-01175 Gas Line Requirements MASSACHUSETTS INSTALLATIONS - WARNING: THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS FITTER WHEN INSTALLED WITHIN THE COMMONWEALTH OF MASSACHUSETTS. OTHER MASSACHUSETTS CODE REQUIREMENTS: • Flexible connector must not be long[...]
-
Página 14
14 Installation (for qualified installers only) © Travis Industries 4060111 100-01175 Vent Requirements • The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas appliance must use it's own separa[...]
-
Página 15
Installation (for qualified installers only) 15 © Travis Industries 4060111 100-01175 Vent Restrictor WARNING : Restrictor adjustment should only be done by a qualified installer. Only those installations determined to be over-drafting require this adjustment. The best indication of over-drafting is a hyper-active flame pattern (flames that move t[...]
-
Página 16
16 Installation (for qualified installers only) © Travis Industries 4060111 100-01175 Vent Location • A vent restrictor is built into the appliance to adjust the flow rate of exhaust gases. This ensures proper combustion for all vent configurations. Depending upon the vent configuration, you may be required to adjust the restrictor position. The[...]
-
Página 17
Installation (for qualified installers only) 17 © Travis Industries 4060111 100-01175 Vent Connector Removal and Installation • The vent connector is shipped attached to the insert, but may be removed to facilitate tight installations. See the directions below for installation. 1. Route the flex vent through the chimney from above (leave an extr[...]
-
Página 18
18 Installation (for qualified installers only) © Travis Industries 4060111 100-01175 Vent Connector Removal and Installation (continued) Vent Connector Removal Slide the connector to the rear. It will "snap" out. Pull the vent connector rod forward. Vent Connector Installation Attach the flex vent to the vent connector. Slide the insert[...]
-
Página 19
Installation (for qualified installers only) 19 © Travis Industries 4060111 100-01175 Surround Panel Installation PANEL SIZE W IDTH HEIGHT PART # 8" x 10" Rectangular 40 -3/8" 28-7/8" 98500610 Arched (8” x 10”) 4 0 -3/8" 28-7/8" 98500622 10” x 13” Rectangular 44-3/8" 31-7/8" 98500611 1 Follow the dir[...]
-
Página 20
20 Installation (for qualified installers only) © Travis Industries 4060111 100-01175 Installation of the On/Off Switch and Rheostat The on/off switch and rheostat may be installed in either the surround panels or control panel. See the illustration below for installation details. c a Disconnect the red and brown wires leading to the on/off switch[...]
-
Página 21
Finalizing the Installation 21 © Travis Industries 4060111 100-01175 Glass Frame Removal and Installation Warning: The appliance must be completely cool before removing the glass. Warning: Do not strike or slam the glass. Open the four latches holding the glass frame in place (start with the two below the glass) - follow the directions shown to th[...]
-
Página 22
22 Finalizing the Installation © Travis Industries 4060111 100-01175 Glass Frame Removal and Installation (continued) The spring pin can come loose from the latch assembly. This occurs when it is turned 1/4 turn when it is disengaged. Follow the directions below to re-install the spring pin if it becomes loose. To re-install the spring pin, first [...]
-
Página 23
Finalizing the Installation 23 © Travis Industries 4060111 100-01175 Log Set Installation Install the rear log. The two pins install into holes on the log. Install the left log. This pin & bolt insert into holes in the bottom of the log. The right log installs the same way. When in place, the logs look like this.[...]
-
Página 24
24 Finalizing the Installation © Travis Industries 4060111 100-01175 These 2 pins install into holes in the bottom of the left twig. The right twig installs over this pin. When in place, the log set should look like the pictures above. Use a kibble to cover any exposed screws. You may wish to flatten the kibble to provide better coverage. Place ot[...]
-
Página 25
Finalizing the Installation 25 © Travis Industries 4060111 100-01175 Steps for Finalizing the Installation 1. Remove the glass (see page 21). NOTE: If using propane (LP) convert the appliance prior to installing the logs. 2. We recommend you purge the gas line at this time (with the glass removed). This allows gas to be detected once it enters the[...]
-
Página 26
26 Finalizing the Installation © Travis Industries 4060111 100-01175 FINE TUNING THE EMBER-FYRE™ BURNER Each installation is affected by altitude, vent configuration, and fuel quality. Because of this, the restrictor and air shutter may need to be fine tuned to each installation. Follow the hints below to fine- tune the burner for optimum perfor[...]
-
Página 27
Operation 2 7 © Travis Industries 4060111 100-01175 Before You Begin • Read this entire manual before you use your new heater (especially the section "Safety Precautions" on pages 4 & 5). Failure to follow the instructions may result in property damage, bodily injury, or even death. Location of Controls Open the access door to view[...]
-
Página 28
2 8 Operation © Travis Industries 4060111 100-01175 Starting The Pilot Flame The pilot flame is required to ignite the main burners (it also plays a safety role). It should be left on once lit. It will stay lit unless the gas control valve is turned to "OFF". However, the pilot will go out if the gas is shut off, the propane tank runs ou[...]
-
Página 29
Operation 2 9 © Travis Industries 4060111 100-01175 Starting the Heater for the First Time • Burn the heater at a high setting with the blower off for an extended period (up to 48 hours). This will cure the painted surfaces. Fumes from the paint curing and oil burning off the steel will occur. This is normal. We recommend opening a window to ven[...]
-
Página 30
3 0 Operation © Travis Industries 4060111 100-01175 Adjusting the Blower Speed The blower helps transfer heat from the heater into the room. It will not turn on until the heater is up to temperature (approximately 10 minutes after starting). See the illustration below for instructions on adjusting the blower speed. OFF Turn the dial all the way co[...]
-
Página 31
Maintenance 31 © Travis Industries 4060111 100-01175 Maintaining Your Heater's Appearance Fingerprints or other marks left on the optional plated surface may become etched in place if they are not wiped clean prior to turning the heater on. Clean the plated surfaces with denatured alcohol and a soft cloth (with the heater cool). Other cleaner[...]
-
Página 32
32 Maintenance © Travis Industries 4060111 100-01175 Troubleshooting Table Problem: Possible Cause: Don't Call for Service Until You: Pilot Will Not Light A gas shut off valve is turned off The gas control knob isn't turned to "PILOT" The valve control knob isn't pushed in The igniter wasn't pressed repeatedly No Prop[...]
-
Página 33
Maintenance 33 © Travis Industries 4060111 100-01175 How this Heater Works This heater was designed with safety as the primary concern. Many of the components inside this heater are for safety purposes. Therefore, only certified gas service technicians should service this heater. What Turns the Main Burners On and Off This heater uses a millivolt [...]
-
Página 34
34 Maintenance © Travis Industries 4060111 100-01175 Wiring Diagram Orange White Piezo Igniter Thermopile Red Thermocouple Copper Co-Axial Wire Red Spark Electrode Pilot Hood On/Off Switch Brown Green Hot (black) Common (white) Ground (green) Power In Molex Connector Ground (attached to stove) White Black Rheostat Black Black White Black Snap Disk[...]
-
Página 35
Safety Label 35 © Travis Industries 4060111 100-01175 Safety Label The safety (listing) label is attached to the operating tag (chained to the heater near the gas control valve). A copy is shown below[...]
-
Página 36
3 6 Limted 7 Year Warranty © Travis Industries 4060111 100-01175 To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed Warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd. SW, Mukilteo, WA 98275. TRAVIS INDUSTRIES, INC. warrants this gas appli[...]
-
Página 37
Optional Equipment (for qualified installers only) 37 © Travis Industries 4060111 100-01175 LP Conversion Instructions Install the conversion kit prior to installing the gas line to ensure proper gas use. 1 Remove the glass (see page 21). Remove the logs and coals (if installed - page 23) 2 Remove the burner (see illustration below). WARNING : Do [...]
-
Página 38
38 Optional Equipment (for qualified installers only) © Travis Industries 4060111 100-01175 3 Follow the directions below to replace the orifices. Look here for the orifice identification Apply thread sealant to the LP orifices prior to installation. Use the chart below to identify the correct orifices. LP .0625 NG #37 c Orifice Manifold 1/2"[...]
-
Página 39
Optional Equipment (for qualified installers only) 39 © Travis Industries 4060111 100-01175 5 Install the logs and embers. 6 Replace glass and face. 7 Remove the regulator from the front of the gas control valve. Replace with the propane regulator, using the new gasket and screws included with the regulator. NOTE: Leak test this area after the hea[...]
-
Página 40
40 Optional Equipment (for qualified installers only) © Travis Industries 4060111 100-01175 Firebacks Slide the top of the rear fireback behind the baffle on top of the firebox and pivot it back into place. It rests on the shelf at the back of the firebox. Hold the side firebacks at a slight angle and place them into position (both sides). Remove [...]
-
Página 41
Optional Equipment (for qualified installers only) 41 © Travis Industries 4060111 100-01175 Lower Surround Panel The older lower surround panel (sku 98500619 and 98500628) are installed in a different fashion than illustrated in the instruction sheet included with the panel. Follow the directions below. 1 Prepare the panel following the directions[...]
-
Página 42
42 Index © Travis Industries 4060111 100-01175 Additional Items Required ....................................7 Adjusting the Blower Speed ..................................3 0 Adjusting the Flame Height ..................................2 9 Air Shutter Adjustment ........................................2 5 Altitude Considerations .................[...]