Universal Electronics 975 manual
- Consulta online o descarga el manual de instrucciones
- 44 páginas
- 0.23 mb
Ir a la página of
manuales de instrucciones parecidos
-
Battery Charger
Universal Electronics II
1 páginas 0.15 mb -
Universal Remote
Universal Electronics URC - 4130
22 páginas 0.26 mb -
Universal Remote
Universal Electronics URC 7800
17 páginas 0.29 mb -
Universal Remote
Universal Electronics DVR 5, PVR 5
36 páginas 0.48 mb -
Universal Remote
Universal Electronics 4-DEVICE Universal Remote Control
32 páginas 1.01 mb -
Universal Remote
Universal Electronics Charter C4000
48 páginas 1.46 mb -
Universal Remote
Universal Electronics ATLAS OCAP
68 páginas 5.8 mb -
Air Compressor
Universal Electronics VR101606
1 páginas 2.19 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Universal Electronics 975. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Universal Electronics 975 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Universal Electronics 975 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Universal Electronics 975, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Universal Electronics 975 debe contener:
- información acerca de las especificaciones técnicas del dispositivo Universal Electronics 975
- nombre de fabricante y año de fabricación del dispositivo Universal Electronics 975
- condiciones de uso, configuración y mantenimiento del dispositivo Universal Electronics 975
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Universal Electronics 975 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Universal Electronics 975 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Universal Electronics en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Universal Electronics 975, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Universal Electronics 975, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Universal Electronics 975. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
Comfor t-Set ® 90 Series 90 Series 90 Series 90 Series 90 Series TM PREMIUM Model 975 Model 975 Model 975 Model 975 Model 975 Installation and Operating Installation and Operating Installation and Operating Installation and Operating Installation and Operating Instructions Instructions Instructions Instructions Instructions Retain for Future Use U[...]
-
Página 2
17 16 4 3 5 6 2 1 7 8 9 10 11 12 13 14 15 Easy, Menu-Driven Set-Up Easy, Menu-Driven Set-Up Easy, Menu-Driven Set-Up Easy, Menu-Driven Set-Up Easy, Menu-Driven Set-Up and Programming and Programming and Programming and Programming and Programming Premium options to customize the thermosta t to fit your applica tion.[...]
-
Página 3
1 INTR ODUCTION Thank you for purchasing your new Model 975 thermo- stat. White-Rodgers has been producing energy sa ving controls for ov er 60 years. W e ha ve been designing and producing the Comfort-Set family of electronic program- mable thermostats since 1982. Model 975 is the third generation of the electronic programmable family . W e believ[...]
-
Página 4
2 THE THERMOSTAT BUTTONS THE THERMOSTAT BUTTONS THE THERMOSTAT BUTTONS THE THERMOSTAT BUTTONS THE THERMOSTAT BUTTONS See inside front cov er for illustration showing button locations. 1 (Blue arrow) Lo wers temperature setting (45°F or 7°C minimum) 2 (Red arrow) Raises temperature setting (99°F or 37°C maximum) 3 The yellow indicator glo ws whe[...]
-
Página 5
3 FAN AUTO HRS CHECK BATTERY STAT SYSTEM ° F AM MON PRG FAN ON HEAT HEAT HRS CHECK BATTERY ° F AM MON WED THU FRI SAT SUN TUE WED THU FRI SAT SUN TUE 18 18 19 20 21 21 22 25 23 24 Figure 1. The Display Orientation THE DISPLAY THE DISPLAY THE DISPLAY THE DISPLAY THE DISPLAY 18 Displays system mode ( HEA HEA HEA HEA HEA T T T T T, OFF OFF OFF OFF O[...]
-
Página 6
4 INST ALLA TION Model 975 : 7 Day programming ELECTRICAL DATA ELECTRICAL DATA ELECTRICAL DATA ELECTRICAL DATA ELECTRICAL DATA Electrical Rating: 17 to 30 V AC, 50/60 Hz 0.05 to 1.5 Amps 1.5 Amps maximum total load (all terminals combined) Standard Systems: Fuel : gas, oil, electric. T ype : Heating/Cooling, Heat Only , Hot W ater or Steam Systems,[...]
-
Página 7
5 Installation PRECAUTIONS PRECAUTIONS PRECAUTIONS PRECAUTIONS PRECAUTIONS ▲ ! WARNING WARNING WARNING WARNING WARNING Do not shor t out ter minals on gas valv e or primar y control to test. Shor t or incor rect wiring will damage ther mostat and could cause personal injur y and/or proper ty damage . Do not use on circuits ex ceeding specified v [...]
-
Página 8
6 ATTENTION! ATTENTION! ATTENTION! ATTENTION! ATTENTION! This product does not contain mercury . Howe ver , this product may replace a unit which contains mercury . Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury . W earing non- absorbent glov es, take up the spilled mercury with sand or other absorbent materi[...]
-
Página 9
7 Installation Insert the wires into the terminals on the base using the appropriate wiring diagram and tighten the terminal screws. CONFIGURING CONFIGURING CONFIGURING CONFIGURING CONFIGURING AND PROGRAMMING AND PROGRAMMING AND PROGRAMMING AND PROGRAMMING AND PROGRAMMING Befor e the power is turned on , the thermostat must be configured to operate[...]
-
Página 10
8 WIRING DIAGRAMS WIRING DIAGRAMS WIRING DIAGRAMS WIRING DIAGRAMS WIRING DIAGRAMS All wiring diagrams are for typical systems only . Refer to equipment manufacturers’ instructions for specific system wiring information. MV 6 Y G W O B RC RH H M V W R H R C GYOB 6 W RH 1 2 3 E L M K J I Figure 2. Typical wiring diagram for heating only, two-wire, [...]
-
Página 11
9 Installation MV 6 Y G W O B RC RH H M V W R H R C GYO B 6 G Y 5 3 C 2 D E 4 RH W 1 L M K J I Figure 3. Typical wiring diagram for heat only, cool only, & heat/cool single transformer system Figure 3. Typical wiring diagram for heat only, cool only, & heat/cool single transformer system Figure 3. Typical wiring diagram for heat only, cool [...]
-
Página 12
10 MV 6 Y G W O B RC RH M V W R H R C GYO B 6 MV RH 1 A WIRING DIAGRAMS WIRING DIAGRAMS WIRING DIAGRAMS WIRING DIAGRAMS WIRING DIAGRAMS 1 F r om milliv olt system NO TE: Ther mostat must ha ve batteries installed. A Milliv olt System B Zone V alve C Cooling System D Fan R elay E Hea ting System F Changeov er Relay Energized in Cooling (Single Stage[...]
-
Página 13
11 Installation 1 F rom heating system 2 F rom 24 V AC transformer 3 F rom fan relay 4 F rom cooling system NO TE: Thermosta t must have batteries installed. MV 6 Y G W O B RC RH M V W R H R C GYOB 6 M V RH A G Y 4 C D 3 RC 2 1 L M K J 1 I Figure 5. Typical wiring diagram for two-wire millivolt heating & three-wire cooling system Figure 5. Typi[...]
-
Página 14
12 WIRING DIAGRAMS WIRING DIAGRAMS WIRING DIAGRAMS WIRING DIAGRAMS WIRING DIAGRAMS H MV W RH RC G Y O B 6 W R H 1 2 6 1 3 B MV 6 Y G W O B RC RH 64 5 2 1 L M K J I 1 F rom zone valve 2 F rom 24 V AC transformer (through zone valve) 3 Red jumper wire (provided) NO TE: Ther mostat must have batteries installed. NO TE: Ensure that RED RH/RC jumper wir[...]
-
Página 15
13 MV 6 Y G W O B RC RH M V W R H R C GYO B 6 W RH 1 2 E N O C D RC G Y 5 3 4 L M K J L M K J Figure 7. Typical wiring diagram for heat/cool, five-wire, two-transformer system Figure 7. Typical wiring diagram for heat/cool, five-wire, two-transformer system Figure 7. Typical wiring diagram for heat/cool, five-wire, two-transformer system Figure 7. [...]
-
Página 16
14 MV 6 Y G W O B RC RH H P MV W RH RC G Y O B 6 RC G Y 5 2 C 1 D 4 3 L M K J I F G WIRING DIAGRAMS WIRING DIAGRAMS WIRING DIAGRAMS WIRING DIAGRAMS WIRING DIAGRAMS Figure 8. Typical wiring diagram for single stage heat pump, four-wire, single transformer system Figure 8. Typical wiring diagram for single stage heat pump, four-wire, single transform[...]
-
Página 17
15 Installation JUMPERS JUMPERS JUMPERS JUMPERS JUMPERS Before turning power on to the system, the jumpers on the back of the thermostat must be configured to operate correctly with the system equipment. This thermostat is configured from the factory to operate a standard fossil fuel (gas, oil, etc.), forced hot air system with a single stage air c[...]
-
Página 18
16 Step Press Button(s) Displayed (F actory Default) Press or to select: COMMENTS 1 EMR (ON) OFF 2 SET CYCL HEA T (05) 02 - 40 Adjusts heat anticipation value (2 through 40) 3 SET CYCL COOL (14) 09 - 40 4 COOL F AN DELA OFF (01) 01 - 127 5 COOL F AN DELA ON (04) 01 - 05 6 COMP LOCK (ON) OFF 7 SYSTEM (HEA T -OFF-COOL-A UT O) HEA T -OFF , COOL-OFF , [...]
-
Página 19
17 8 0 ˚ F (0) 5 LO to 5 HI 9 ( ˚ F) C 11 REMT SEN (OFF) ON Selects remote sensor OFF or ON 12 P AR T LOCK (OFF) ON Selects partial keypad lock out OFF or ON 13 LOCK (OFF) ON Selects total keypad lock out OFF or ON 14 Returns to normal operation 10 BEEP (ON) OFF T urns beeper ON or OFF Adjusts temperature display higher or lower Adjusts temperatu[...]
-
Página 20
18 CONFIGURATION CONFIGURATION CONFIGURATION CONFIGURATION CONFIGURATION INSTALLER INSTALLER INSTALLER INSTALLER INSTALLER CONFIGURATION CONFIGURATION CONFIGURATION CONFIGURATION CONFIGURATION The configuration settings can be changed at any time to meet system or personal requirements. Press PROGRAM RUN to make certain the thermostat is in the run[...]
-
Página 21
19 Installation COOLING is from 9 to 40. The factory preset is 14. The recom- mended initial setting for hydronic systems is 35. The cooling will not go below 9 because compressors require a longer cycle. The chart below sho ws how this adjustment range affects thermostat performance. HEA TING COOLING Anticipation V alue Cycle Length Differential T[...]
-
Página 22
20 CONFIGURATION CONFIGURATION CONFIGURATION CONFIGURATION CONFIGURATION would be set so the fan shuts of f just as the cool air is exhausted. If this timing is set too long the fan may begin blo wing warm air before it shuts off. Shortening the f an-off delay will prev ent this. COMPRESSOR LOCKOUT COMPRESSOR LOCKOUT COMPRESSOR LOCKOUT COMPRESSOR L[...]
-
Página 23
21 temperature display . This is an excellent feature if the thermostat is in a poor location for sensing temperature or the thermo- stat is in a separate room to prev ent tampering. NOTE The remote sense featur e will not work if the system does not pro vide 24V to the thermostat (example: millivolt heating-only systems or 3-wire zone valv es). T [...]
-
Página 24
22 COOLING SYSTEM COOLING SYSTEM COOLING SYSTEM COOLING SYSTEM COOLING SYSTEM CHECK THERMOSTAT OPERATION CHECK THERMOSTAT OPERATION CHECK THERMOSTAT OPERATION CHECK THERMOSTAT OPERATION CHECK THERMOSTAT OPERATION T o pr event compressor and/ or property damage, if the outdoor temperature is below 50°F (10°C), DO NO T operate the cooling system. 1[...]
-
Página 25
23 The configuration menus allo w you to set certain thermostat operating characteristics to your system or personal requirements. T o enter the User Configuration menu, press PROGRAM RUN to make sure the thermostat is in the run program mode, then press TIME FWD and TIME BACK at the same time to enter the configuration menu. The display will show [...]
-
Página 26
24 CONFIGURATION MENU CONFIGURATION MENU CONFIGURATION MENU CONFIGURATION MENU CONFIGURATION MENU Step Press Button(s) Displayed (F actory Default) Press or to select: COMMENTS 1 EMR (ON) OFF 2 SET CYCL HEA T 3 SET CYCL COOL 4 COOL F AN DELA OFF 5 COOL F AN DELA ON 6 COMP LOCK 7 SYSTEM Selects EMR option ON or OFF TIME FWD TIME FWD TIME FWD TIME FW[...]
-
Página 27
25 Configuration 8 0 ˚ F (0) 5 LO to 5 HI 9 ( ˚ F) ˚ C 11 REMT SEN 12 P AR T LOCK (OFF) ON Selects partial keypad lock out OFF or ON 13 LOCK (OFF) ON Selects total keypad lock out OFF or ON 14 Returns to normal operation 10 BEEP (ON) OFF T urns beeper ON or OFF Adjusts temperature display higher or lower Adjusts temperature display to ˚ F or ˚[...]
-
Página 28
26 PR OGRAMMING MANUAL OPERATION MANUAL OPERATION MANUAL OPERATION MANUAL OPERATION MANUAL OPERATION Y our Comfort-Set 90 thermostat can be used to control temperature manually (without programming). For manual operation, press SYSTEM to select HEAT HEAT HEAT HEAT HEAT or COOL COOL COOL COOL COOL , then press PROGRAM HOLD . Use or to set the temper[...]
-
Página 29
27 Programming and the settings for time and temperature. 9. If you program Monday the first time you press PROGRAM VIEW it will be copied to the rest of the week. T o program the other days of the week press ADV . / DA Y to until you reach the day you wish to change and follow Steps 10, 11 & 12. Y ou can also copy the program from one day to a[...]
-
Página 30
28 62 ° F (16 ° C) 62 ° F (16 ° C) 62 ° F (16 ° C) 62 ° F (16 ° C) 62 ° F (16 ° C) 62 ° F (16 ° C) 62 ° F (16 ° C) 5:00 PM 5:00 PM 5:00 PM 5:00 PM 5:00 PM 5:00 PM 5:00 PM 10:00 PM 10:00 PM 10:00 PM 10:00 PM 10:00 PM 10:00 PM 10:00 PM 62 ° F (16 ° C) 62 ° F (16 ° C) 62 ° F (16 ° C) 62 ° F (16 ° C) 62 ° F (16 ° C) 62 ° F (16 [...]
-
Página 31
29 82 ° F (27 ° C) 82 ° F (27 ° C) 82 ° F (27 ° C) 82 ° F (27 ° C) 82 ° F (27 ° C) 82 ° F (27 ° C) 82 ° F (27 ° C) 5:00 PM 5:00 PM 5:00 PM 5:00 PM 5:00 PM 5:00 PM 5:00 PM 10:00 PM 10:00 PM 10:00 PM 10:00 PM 10:00 PM 10:00 PM 10:00 PM 85 ° F (29 ° C) 85 ° F (29 ° C) 85 ° F (29 ° C) 85 ° F (29 ° C) 85 ° F (29 ° C) 85 ° F (29 [...]
-
Página 32
30 7 Day Personal HEA T Program Schedule 1 Morning (MOR) 2 Day (DA Y) 3 Evening (EVE) 4 Night (NHT) 5 Start T ime 6 T emperature MON TUE WED THU FRI SA T SUN 1 5 6 5 6 5 6 5 6 2 3 4[...]
-
Página 33
31 7 Day Personal COOL Program Schedule MON TUE WED THU FRI SA T SUN 1 5 6 5 6 5 6 5 6 2 3 4 1 Morning (MOR) 2 Day (DA Y) 3 Evening (EVE) 4 Night (NHT) 5 Start T ime 6 T emperature Programming[...]
-
Página 34
32 FEA TURES Large Lighted Liquid Large Lighted Liquid Large Lighted Liquid Large Lighted Liquid Large Lighted Liquid Crystal Display (LCD). Crystal Display (LCD). Crystal Display (LCD). Crystal Display (LCD). Crystal Display (LCD). The large numbers and letters on your LCD screen make it easy to see. In low light conditions, press the button on to[...]
-
Página 35
33 is 3 hours and 45 minutes. Cooling can start earlier because it takes longer for cooling systems to reach the desired temperature. T o select or deselect this feature, refer to the CONFIGURA TION section (page 24, step 1). Adjustable Adjustable Adjustable Adjustable Adjustable Temperature Display. Temperature Display. Temperature Display. Temper[...]
-
Página 36
34 change or clean your air filter . The factory set interv al for CHNG FL TR to be displayed is 200 hours of fan operation. This can be set anywhere from 0 to 1950 hours in 25 hour increments. A selection of 00 will cancel this feature. When CHNG FL TR is displayed, you can clear it by pressing the FIL TER b utton. This resets the timer and starts[...]
-
Página 37
35 a specific amount of time, press or until the tempera- ture you want is displayed. The display will indicate HOLD , and the number of hours remaining in the hold period will be indicated with the word HRS . T o adjust the length of time for the ov erride, press TIME FWD or TIME BACK . HOLD TILL will be displayed as well as the HOLD period expira[...]
-
Página 38
36 Daylight Savings Time Button. Daylight Savings Time Button. Daylight Savings Time Button. Daylight Savings Time Button. Daylight Savings Time Button. One button adjustment allo ws you to change your thermostat clock between Standard T ime and Daylight Savings time. Simply push the D A YLIGHT SA VINGS TIME button to adv ance the time forward one [...]
-
Página 39
37 allows only the or to operate for temporary temperature ov errides. It also limits the tempera- ture to the maximum heating and minimum cooling temperatures used in your program. This is especially useful in buildings where unsched- uled ev ents are common. Anyone can change the temperature, bu t only between the temperatures you set and only fo[...]
-
Página 40
• One of the buttons is stuck do wn or in. Check buttons, mak e sure nothing is pushing them in. • The thermostat sensor is not functioning. If using a remote sensor , check connections, wiring and power . After checking the abov e, press PROGRAM RUN to reset the display . If this does not clear the display , disconnect power and remov e the ba[...]
-
Página 41
PR OGRAMMING --------------- 26 Schedule Sample Programs -------------- 2 8 Personal Programs ------------- 30 Set Clock ---------------------------- 26 Day ------------------------------ 26 Program ------------------------- 26 Setpoint Range -------------------- 32 System and Thermostat Diagnosis ----------------------- 37 Thermostat Startup After[...]
-
Página 42
NO TES[...]
-
Página 43
[...]
-
Página 44
PART NO. 37-6438A 0223 The Emerson logo is a trademark and ser vice mark of Emerson Electric Co. White-Rodg ers is a division of Emerson Electric Co. Printed in U .S.A.[...]