Vanguard Heating 107156-01E.pdf manual
- Consulta online o descarga el manual de instrucciones
- 38 páginas
- 4.53 mb
Ir a la página of
manuales de instrucciones parecidos
-
Indoor Fireplace
Vanguard Heating VDVF36PP
30 páginas 0.95 mb -
Indoor Fireplace
Vanguard Heating 36" Flame Oak Log
26 páginas 0.56 mb -
Indoor Fireplace
Vanguard Heating VDVF36STN
30 páginas 0.95 mb -
Indoor Fireplace
Vanguard Heating VSGF28PTC
32 páginas 1.12 mb -
Indoor Fireplace
Vanguard Heating VDVF36STP
30 páginas 0.95 mb -
Indoor Fireplace
Vanguard Heating 30"
26 páginas 0.56 mb -
Indoor Fireplace
Vanguard Heating VMH10TNA
28 páginas 0.8 mb -
Indoor Fireplace
Vanguard Heating VDDVF36STN/STP
32 páginas 0.95 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Vanguard Heating 107156-01E.pdf. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Vanguard Heating 107156-01E.pdf o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Vanguard Heating 107156-01E.pdf se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Vanguard Heating 107156-01E.pdf, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Vanguard Heating 107156-01E.pdf debe contener:
- información acerca de las especificaciones técnicas del dispositivo Vanguard Heating 107156-01E.pdf
- nombre de fabricante y año de fabricación del dispositivo Vanguard Heating 107156-01E.pdf
- condiciones de uso, configuración y mantenimiento del dispositivo Vanguard Heating 107156-01E.pdf
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Vanguard Heating 107156-01E.pdf no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Vanguard Heating 107156-01E.pdf y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Vanguard Heating en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Vanguard Heating 107156-01E.pdf, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Vanguard Heating 107156-01E.pdf, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Vanguard Heating 107156-01E.pdf. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
UNVENTED (VENT -FREE) PROP ANE/LP GAS FIREPLACE OWNER’S OPERA TION AND INST ALLA TION MANUAL Save this manual for future reference. Save this manual for future reference. Shown with optional cabinet mantel, hearth base, and trim accessories. WARNING: If the information in this manual is not fol- lowed exactly, a fire or explosion may result causi[...]
-
Página 2
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 2 Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater. Fireplace front and [...]
-
Página 3
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 3 3 PRODUCT IDENTIFICA TION Figure 1 - Log Base Assembly, Split Oak Set Rear Log Rear Burner Crossover Log Middle Log Front Log Front Burner SAFETY INFORMA TION Continued 1. This appliance is only for use with the type of gas indicated on the rating[...]
-
Página 4
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 4 AIR FOR COMBUSTION AND VENTILA TION Today’s homes are built more energy efficient than ever. New mate- rials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows a[...]
-
Página 5
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 5 5 DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any[...]
-
Página 6
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 6 VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and o[...]
-
Página 7
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 7 7 INST ALLA TION Continued Note: Your fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the rear, sides, or top of your fireplace, except where standof[...]
-
Página 8
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 8 INST ALLA TION Continued Figure 7 - Attaching Brass Trim to Fireplace Figure 6 - Assembling Brass Trim IMPORTANT: If you are recessing the firebox in a wall, do not attach brass trim at this time. See page 1 0 for built-in fireplace installation. [...]
-
Página 9
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 9 9 Figure 9 - Placing Hearth Base Accessory Against Wall Electrical Outlet Hearth Base Rigid Pipe and Gas Shutoff Valve Gas Line Access Hole INST ALLA TION Continued Figure 10 - Installing Cabinet Mantel Cabinet Mantel 1. Assemble cabinet mantel, h[...]
-
Página 10
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 10 Mantel Clearances for Built-In Installation If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening. If your installation does not meet the below minimum clearances, you must: [...]
-
Página 11
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 11 11 Pipe Tee Nipple Cap Joint INST ALLA TION Continued CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in cer- tain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow prop[...]
-
Página 12
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 12 Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect fireplace with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply pipping. Pres- sures in excess of 1/2 p[...]
-
Página 13
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 13 13 Equipment Shutoff Valve Propane/LP Supply Tank INST ALLA TION Continued Figure 21 - Equipment Shutoff Valve ON POSITION OFF POSITION Open Closed Equipment Shutoff Valve Figure 22 - Checking Gas Joints Gas Control Valve Test Pressures Equal To [...]
-
Página 14
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 14 A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, f ollo w these instructions e xactly . B. BEFORE LIGHTING smell all ar ound the appliance ar ea for gas. Be sur e to smell next to the floor because some gas is[...]
-
Página 15
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 15 15 Figure 29 - Pilot CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve. LIGHTING INSTRUCTIONS WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is installed bef[...]
-
Página 16
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 16 Figure 31 - Pilot Ignitor Electrode Pilot Burner IGNITOR Figure 30 - Control Knob and Ignitor Button Location Ignitor Button Control Knob OPERA TING FIREPLACE Continued A. This appliance has a pilot which must be lighted by hand. When lighting th[...]
-
Página 17
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 17 17 OPERA TING FIREPLACE Continued Locate the blower switch by opening lower louver on fireplace. Blower switch is located at lower left inside louver door. This thermostat-controlled blower has a variable speed control with an ON/OFF switch. The [...]
-
Página 18
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 18 If front burner flame pattern is incorrect, as shown in Figure 35 • turn fireplace of f (see T o T urn Off Gas to Appliance , page 15 [ther- mostat-controlled models] or page 17 [manually-controlled models]) • see T roubleshooting , pages 20 [...]
-
Página 19
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 19 19 CLEANING AND MAINTENANCE WARNING: Turn off fireplace and let cool before cleaning. CAUTION: You must keep control areas, burners, and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have firepl[...]
-
Página 20
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 20 POSSIBLE CAUSE 1. Ignitor electrode not connected to igni- tor cable 2. Piezo ignitor nut is loose 3. Ignitor cable pinched or wet 4. Broken ignitor cable 5. Bad piezo ignitor 6. Ignitor electrode broken 7. Ignitor electrode positioned wrong 1 . [...]
-
Página 21
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 21 21 TROUBLESHOOTING Continued OBSERVED PROBLEM One or both burners do not light after ODS/ pilot is lit Delayed ignition of one or both burners Burner backfiring during combustion Yellow flame in front burner during burner combustion Slight smoke [...]
-
Página 22
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 22 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neigh[...]
-
Página 23
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 23 23 Btu (Low/High) 20,000/28,000 Type Gas Propane/LP Gas Only Ignition Piezo Manifold Pressure 7.9" W.C. Inlet Gas Pressure (in. of water) Maximum 14" Minimum 11" Shipping Weight 100 lbs. T-stat Model 97 lbs. Manual Model SPECIFICA [...]
-
Página 24
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 24 ILLUSTRA TED P ARTS BREAKDOWN LOG BASE ASSEMBLY VARIABLE MANUALLY- CONTROLLED MODELS VSGF28PVA 26 7 8 7 7 18 6 12 11 7 5 9 17 22 15 10 25 13 5 5 5 5 20 14 18 31 28 23 29 19 27 30 24 16 21 32 1 2 3 4 ILLUSTRATED PARTS BREAKDOWN VSGF28PVA[...]
-
Página 25
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 25 25 P AR TS LIST LOG BASE ASSEMBLY VARIABLE MANUALLY-CONTROLLED MODELS VSGF28PVA This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual. KE[...]
-
Página 26
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 26 ILLUSTRA TED P ARTS BREAKDOWN FIREPLACE VSGF28PVA 1 2 3 16 4 6 12 18 10 10 7 13 16 16 16 7 17 14 5 16 16 15 8 9 16 11 11 11 ILLUSTRATED PARTS BREAKDOWN VSGF28PVA[...]
-
Página 27
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 27 27 P AR TS LIST FIREPLACE VSGF28PVA This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 101357-[...]
-
Página 28
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 28 ILLUSTRA TED P ARTS BREAKDOWN LOG BASE ASSEMBLY THERMOSTAT-CONTROLLED MODELS VSGF28PTC 17 5 7 8 7 7 18 6 12 26 11 1 2 4 3 9 15 10 25 13 28 5 5 5 5 21 24 22 18 23 12 6-2 19 14 27 20 28 16 ILLUSTRATED PARTS BREAKDOWN VSGF28PTC[...]
-
Página 29
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 29 29 P AR TS LIST LOG BASE ASSEMBLY THERMOSTAT-CONTROLLED MODELS VSGF28PTC This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual. KEY NO. P[...]
-
Página 30
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 30 ILLUSTRA TED P ARTS BREAKDOWN FIREPLACE VSGF28PTC 1 2 3 4 16 16 6 12 18 10 10 7 13 16 26 24 16 23 25 20 24 24 21 16 16 7 17 14 5 16 16 15 8 9 19 22 11 11 11 ILLUSTRATED PARTS BREAKDOWN VSGF28PTC[...]
-
Página 31
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 31 31 P AR TS LIST FIREPLACE VSGF28PTC This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 101357-[...]
-
Página 32
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 32 SLIM HEARTH BASE (Not Shown) G3005J Series - Jade Marble Laminate G3005S Series - Sandstone Marble Laminate G3005B Series - Black Onyx Marble Laminate The slim hearth base allows you to further customize your fireplace. Dimensions (WxHxD): 41 7 /[...]
-
Página 33
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 33 33 EQUIPMENT SHUTOFF VALVE - GA5010 For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe. BLOWER ACCESSORIES FOR MANUALLY- CONTROLLED UNITS GA3750A & GA3650TB SERIES Manual variable speed control and automat[...]
-
Página 34
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 34 NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ ________________________________________________[...]
-
Página 35
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 35 35 1. Where will the product be used? ❍ Living/Family Room ❍ Office/W arehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ Bathroom ❍ Other 2. If you bought this product yourself, did you plan to purchase this type of product be[...]
-
Página 36
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 36 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 Postage Required TM T APE T APE[...]
-
Página 37
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 37 37 NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________________________[...]
-
Página 38
107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 38 Model Serial No. Date Purchased LIMITED WARRANTY VENT-FREE PROPANE/LP GAS FIREPLACE DESA International warrants this product to be free from defects in materials and components for four (4) years and five (5) years on stainless steel burners from[...]