Vinotemp WINE-MATE VINO2500SSH manual
- Consulta online o descarga el manual de instrucciones
- 32 páginas
- 0.94 mb
Ir a la página of
manuales de instrucciones parecidos
-
Refrigerator
Vinotemp VINO6500HZD
25 páginas 0.59 mb -
Refrigerator
Vinotemp WM250-850SCU
8 páginas 0.31 mb -
Refrigerator
Vinotemp VT-6TED-WW
16 páginas 0.28 mb -
Refrigerator
Vinotemp VINO-2500SSW
20 páginas 0.37 mb -
Refrigerator
Vinotemp WINE-MATE VINO2500SSD
7 páginas 0.19 mb -
Refrigerator
Vinotemp VT-12TEDi
12 páginas 0.81 mb -
Refrigerator
Vinotemp WM25-85SFCD
8 páginas 0.31 mb -
Refrigerator
Vinotemp WM-25SFCL
25 páginas 0.51 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Vinotemp WINE-MATE VINO2500SSH. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Vinotemp WINE-MATE VINO2500SSH o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Vinotemp WINE-MATE VINO2500SSH se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Vinotemp WINE-MATE VINO2500SSH, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Vinotemp WINE-MATE VINO2500SSH debe contener:
- información acerca de las especificaciones técnicas del dispositivo Vinotemp WINE-MATE VINO2500SSH
- nombre de fabricante y año de fabricación del dispositivo Vinotemp WINE-MATE VINO2500SSH
- condiciones de uso, configuración y mantenimiento del dispositivo Vinotemp WINE-MATE VINO2500SSH
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Vinotemp WINE-MATE VINO2500SSH no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Vinotemp WINE-MATE VINO2500SSH y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Vinotemp en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Vinotemp WINE-MATE VINO2500SSH, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Vinotemp WINE-MATE VINO2500SSH, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Vinotemp WINE-MATE VINO2500SSH. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
w w w w w w . . w w i i n n e e m m a a t t e e . . c c o o m m WINE-MATE Split System Installation, Operation & Care Manual VINO2500SSH 4500SSH VINO6500SSH 8500SSH V V i i n n o o t t e e m m p p I I n n t t e e r r n n a a t t i i o o n n a a l l C C o o r r p p . . w w w w w w . . v v i i n n o o t t e e m m p p . . c c o o m m RE AD A ND SA[...]
-
Página 2
- 1 - TABLE OF CONTENTS Important Safety Info rmation…..........................................2 Features & Specifications.…………………….……………..3 Cellar Construction.…………………………….……………..7 Installer’s Instruction…………….…..….……..……………..8 Electrical Wiring…..…?[...]
-
Página 3
- 2 - Important Safety Information WARNING: • DO NOT USE A GROUND FAUL T INTERRUPTER (GFI). • A DEDICATED 20 OR 30 AMP CIRCUIT IS REQUIRED (2500-4500SSH OR 6500-8500SSH).[...]
-
Página 4
- 3 - Features and Specifications • Wine-Mate split cooling systems VINO2500-8500SSH are designed and used to provide a cold temperature between 50~65 ° F for a properly insulated wine room at a normal environment. • The wine room will maintain hum idity of 50~70% RH even when the environment becomes dry and humid. T hese temperatures and humi[...]
-
Página 5
- 4 - NOTE: LEAVE MINIMUM 3” CLEARANCE FOR ELECTRICAL WIRING AND REFRIGERATION PIPING. Parts included: Condensing Unit (discharge and suction valves installed) + Liquid Filter + Liquid Indicator Evaporator Unit (liquid line solenoid va lve and expansion valve installed) Temperature Controller + Air Sensor Fig. 1 WM25-85SFCH Evaporator Unit[...]
-
Página 6
- 5 - Fig. 2 WM250-450SCU Condensing Unit Fig. 3 WM650-850SCU Condensing Unit[...]
-
Página 7
- 6 - Fig. 4 Liquid Filter Fig. 5 Liquid Indicator[...]
-
Página 8
- 7 - Cellar Construction This is only a guide and shall be c onsidered as minimum requirements. All interior walls and floors shall have a vapor barrier and a minimum of R11 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation. The vapor barrier s hall be installed on the warm side of the insulation[...]
-
Página 9
- 8 - Installer’s Instruction Federal law requires that WINE-M ATE split cooling systems be installed by an EPA certified refrigeration technician. WINE-MATE split system is shipped as components and is ready for use only after a certified refrigeration technici an has properly in stalled, evacuated, charged and tested the system. Pr oper install[...]
-
Página 10
- 9 - 1. Condensing Unit • Place the condensing units WM250-850SCU in a properly ventilated location. If it is not, heat exhausted by the condensing unit will build up and the coolin g system will not operate properly. • Condensing unit shall be elevated to avoid possible flooding and shaded from direct sun. It shall not be exposed to temperat [...]
-
Página 11
- 10 - 1 - Process & Manometer; 2 – Receiver Di scharge or Compressor Suction 3 – Liquid Line or Suction Line; 4 - Pressure Control 3. Evaporator Unit • The WM25-85SFCH evaporator units can be installed outside a wine room. • Supply air flow shall be unobstructed fo r at least 12” for free installation or 2” for deflector installati[...]
-
Página 12
- 11 - valve, expansion valve, and suction line connection), returning to insulated suction line, suction valve and then back to condensing unit. 2) Use inverted siphons to prevent liquid from flooding back to the compressor and aid oil returning to the compressor. 3) Both discharge and suction valves must be in the middle positions during evacuati[...]
-
Página 13
- 12 - 12) If the superheat is low, then decrease the evaporator suction pressure by turning the hex nut (5/16”) counter-clockwise. 13) Both discharge and suction valv es mu st be in the back positions before disconnecting evacuating and pressure gauges. Fig. 10 Expansion Valve The line sizes and refrigerant charges are listed as follows. MODEL R[...]
-
Página 14
- 13 - A. P70 Single/Dual Control Fig. 11 Adjustable Pressure Control B. PS2 Dual Control Fig. 12 Adjustable Pressure Control[...]
-
Página 15
- 14 - 7. Use of the encapsulated pressu re control (if applicable) Fixed suction pressure setting: Cut in = 32 psig; Cut out = 10 psig Fig. 13 Fixed Pressure Control 8. Use of the condenser fan control (i f applicable for low ambient kit) Head pressure setting: Cut in=170 psig; Cut out=120 psig; Differential=50 psig It closes on rise of pressure. [...]
-
Página 16
- 15 - High superheat and high subcooling i. Low suction pressure a nd l ow head pressure Normal to high superheat and low su bcooling j. Low suction pressure a nd l ow head pressure Low superheat and low subcooling k. Low suction pre s sure and low to normal head p ressure High superheat and normal to high subcooling l. Low suction pressure and n [...]
-
Página 17
- 16 - Electrical Wiring CAUTION: • HIDDEN LINES ARE FO R FIELD WIRINGS. • MINIMUM 14 GAUGE WIR ES FOR POWER LINES. • IF EQUIPPED WITH LOW AMBIENT CO NDITION KIT, USE LOW AMBIENT TEMPERATURE WIRING DIAGRAMS. TURN OFF THE COMPRESSOR BEFORE POWER THE CONDENSING UNIT. ONLY TURN ON THE COMPRESSOR AFTER THE CONDENS ING UNIT HAS BEEN POWERED FOR 24[...]
-
Página 18
- 17 - Fig. 15 VINO6500SSH Elect rical Wiring Diagram[...]
-
Página 19
- 18 - Fig. 16 VINO8500SSH Wiring Diagram[...]
-
Página 20
- 19 - Fig. 17 Low Ambient Temperature VINO2500 & 4500SSH Wiring Diagram[...]
-
Página 21
- 20 - Fig. 18 Low Ambient Temperature VINO6500SSH Electrical Wiring Diagram[...]
-
Página 22
- 21 - Fig. 19 Low Ambient Temperature VINO8500SSH Wiring Diagram[...]
-
Página 23
- 22 - Temperature Control & Humidity Adjustment 1. Temperature Setting • Set the temperature at 55 ° F for the optimum aging of wine • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantit y of bottles, temperature setting and surrounding temperature. • Allow 24 hours to stabilize th[...]
-
Página 24
- 23 - 2.1 LED Functions LED MODE FUNCTION ON Compressor enabled Flashing Anti-short cycle enabled ON Defrost cycle enabled ON Fan enabled Flashing Fan delay after defrost enabled ON Alarm occurring ON Temperature measuring unit Flashing Programming mode 3) Alarm Signals 3.1 Code Description MESSAGE CAUSE FUNCTION P1 Temperature probe faulty Compre[...]
-
Página 25
- 24 - 5) Parameter Programming 1. Press the SET + keys for 3 sec until the “ °C” or “°F” LED starts blinking, then release the keys. 2. Press again the SET + keys for more th an 7sec until the Pr2 label will be displayed, then release the keys. The first parameter Hy will be displayed. 3. Press up/down keys / to select the required param[...]
-
Página 26
- 25 - Care Guide In general, always unplug system or di sconnect power while doing care. 1. Coil Cleaning • Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months. • Unplug the system or disconnect power. • Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty. • Plug [...]
-
Página 27
- 26 - User’s Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration servic e person, not is it comprehensive Complaint Possible Causes Response 1.Unit not running a. No power b. Power cord u nplugged c. Setting higher than ambient temperature d. Defrost light blinking e. Compr[...]
-
Página 28
- 27 - running continually e. Malfunctioning fans f. Improper evaporator or condenser airflow g. Dir ty C ondenser h. Iced evaporator i. Sealed system problem j. Undercharge or overcharg e the exhaust side and leave minimum 1 foot clearance for the fresh air intake side e. Check for both evaporator and condenser fans f. Check for air re strictions [...]
-
Página 29
- 28 - 10.Noisy operation a. Mounting area not firm b. Loose parts c. Compressor overlo aded due to high ambient temperatures o r airflow restrict ion d. Malfunctioning components a. Add support to improve in stallation b. Check fans, cabinet wa shers, tubing contact and loose screws. c. Check for airflow bl ockage d. Call service for checkin g Int[...]
-
Página 30
- 29 - Customer Support If you still have problems, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: info@vinotemp.com[...]
-
Página 31
- 30 - Warranty Thank you for choosing a Vinotemp cooling unit. Please enter the complete model and se rial numbers in the space provided: Model_____________ _________________________ __ _________________ Serial No._________________ ____________________ _________________ Attach your purchase receipt to this owner’s manual. 1. Limited Warranty VIN[...]
-
Página 32
- 31 - VINOTEMP will, at its discret ion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect. 2. Limitation of Implied Warranty VINOTEMP’S SOLE LIABI LITY FOR ANY DEFECTIVE PRODUCT [...]