AquaStar 125B LP manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 16 pages
- 0.87 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Water Heater
AquaStar 125B LPL
20 pages 0.46 mb -
Water Heater
AquaStar 125X
13 pages 0.16 mb -
Water Heater
AquaStar 125B NGS
24 pages 0.66 mb -
Water Heater
AquaStar 2700 ES
8 pages 0.59 mb -
Water Heater
AquaStar 125FX NG
24 pages 0.82 mb -
Water Heater
AquaStar 2400 ES
8 pages 0.59 mb -
Water Heater
AquaStar 125HX NG
24 pages 0.73 mb -
Water Heater
AquaStar 125BS
13 pages 0.16 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation AquaStar 125B LP. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel AquaStar 125B LP ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation AquaStar 125B LP décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation AquaStar 125B LP devrait contenir:
- informations sur les caractéristiques techniques du dispositif AquaStar 125B LP
- nom du fabricant et année de fabrication AquaStar 125B LP
- instructions d'utilisation, de réglage et d’entretien de l'équipement AquaStar 125B LP
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage AquaStar 125B LP ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles AquaStar 125B LP et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service AquaStar en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées AquaStar 125B LP, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif AquaStar 125B LP, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation AquaStar 125B LP. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
W ARNING : Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer , service agency or the gas supplier . Upon completion of the installation, these instructions should be handed to the user of the applianc[...]
-
Page 2
2 This well engineered, gas water heater has all the fea- tures a water heater should have: It operates on the principle of heating water instantaneously “on demand”. When a hot water faucet is opened, cold water flows through the coils of the heat exchanger in the Aquastar . This same flow opens the gas valve, and the burners are ignited by th[...]
-
Page 3
3[...]
-
Page 4
4 If you are using the AquaStar for combined space heating and potable water heating (see schematic diagram below) , all piping and other components connected to the system must be suitable for potable water , (b) toxic chemicals such as those commonly used for boiler treatment to prevent corrosion and freezing must not be introduced into the syste[...]
-
Page 5
5 4. Y ou must vent your heater. See section on V ent Pipe Connections, Page 5. 5. The appliance must be disconnected from the gas supply piping system during any pressure testing at pressures in excess of 1/2 Psig (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any p[...]
-
Page 6
6 CLEARANCES The Aquastar 125 B is design certified for installation on a combustible wall and for installation in an alcove with the minimum clearances to combustible and non -combustible construction listed below A. T op 12 inches ( 305 mm) B. Front Open C. Back 0 inches D. Sides 4 inch (102mm) E. Bottom 12 inches (306 mm) Clearance from vent is [...]
-
Page 7
7 The flue connection for the AquaStar 125B is 5 inches. However , in Canada, for installations at high altitude (2000- 4500 feet above sea level) a six inch flue is required. A 5" by 6" flue adaptor must be affixed to the flue collar of the AquaStar with at least two screws. See figure 3 Fig. 3 - Flue Adaptor for High Altitude Installati[...]
-
Page 8
8 OPERA TING INSTRUCTIONS Before proceeding with the operation of the heater make sure that the system is filled with water . Make sure the water heater drain plug is closed. See Figure 7 below . Fig. 7 - W ater heater drain plug Open the cold water inlet supply to the heater fully . Open a hot water faucet to permit the water to fill the heater an[...]
-
Page 9
9 LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above on this plate. 2. The Gas valve must be turned off by sliding the gas valve button to the far left under the OFF ( ) mark. 3. W ait five (5) minutes to clear out any gas. If you smell gas, STOP! Follow “B” in the safety information above on this plate. If you don’t smell gas, [...]
-
Page 10
10 TROUBLE SHOOTING Introduction The AquaStar 125 burners are activated by a water flow valve. Numerous water related problems can cause this water valve to malfunction such as: Insufficient water flow volume to activate the burners at its minimum flow requirement; Dirt in the water flow valve causing it to malfunction; Sediment build-up in faucet [...]
-
Page 11
11 6 . Faulty thermocouple (part #8747202083) or electromagnet ) Unless these 2 parts are at least 8 to 10 years old, it is very unlikely that they are faulty . Before testing, reconfirm that #2 is absolutely correct, and that all connections are clean and tight. T o test the thermocouple, disconnect the thermocouple lead to the ECO. Insert a multi[...]
-
Page 12
12 PILOT LIGHT GOES OUT DURING OR IMMEDIA TEL Y AFTER HOT W A TER HAS BEEN USED 1. Gas pressure too low V ery low gas pressure may be caused by low delivered gas pressure, a jammed gas regulator or undersized gas lines. If the gas lines are undersized, there may still be the specified static gas line pressure. However when the water valve opens, an[...]
-
Page 13
13 Fig. 1 1 - Diagram of AquaStar 125 B 5 11 1 4 9 10 1. Heat exchanger 2. Pilot assembly 3. Burner manifold gas pressure test nipple 4. Main gas burner 5. Pilot gas tubing 6. Gas valve 7. Pressure tap screw location 8. Gas control slide 9. Piezo igniter 10. W ater valve 1 1. T emperature adjustment selector 12. Gas inlet gas pressure test nipple 3[...]
-
Page 14
14 Fig. 12 - INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST[...]
-
Page 15
15 Fig. 12 INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST 125B 1 Cover ¤ 8 705 421 025 2 Plastic collar ¤ 8 700 403 008 3 T emperature adjustment knob ¤ 8 702 000 1 1 1 4 Panel back ¤ 8 705 402 164 5 Draft divertor ¤ 8 705 505 354 6 Heat exchanger ¤ 8 705 406 235 7 Hot water pipe ¤ 8 700 705 556 8 Cold water pipe ¤ 8 700 705 294 9 Heat exchang[...]
-
Page 16
Replacement Parts available from North American Distributor CONTROLLED ENERGY CORP . 340 Mad River Park V ermont 05673 (U.S.A.) Phone 800-642-31 1 1 Fax (802) 496-6924 WWW .CECHOT .COM VULCANO T ermodomésticos S.A. Estrada de Cacia 3800 Cacia - PORTUGAL Recycled paper techsupport@cechot.com GA S LINE SIZE Natural Gas Nominal Iron Pipe Size* 1/2&qu[...]