Indoor Fireplace
Avalon Stoves Seattle E
4 pages 0.47 mb -
Indoor Fireplace
Avalon Stoves DVL Insert EF II
44 pages 1.54 mb -
Indoor Fireplace
Avalon Stoves ST Fireback 864
2 pages 1.33 mb -
Indoor Fireplace
Avalon Stoves Flush Wood Insert
34 pages 1.18 mb -
Indoor Fireplace
Avalon Stoves 564 SS
30 pages 4.76 mb -
Indoor Fireplace
Avalon Stoves HH
16 pages 1.56 mb -
Indoor Fireplace
Avalon Stoves 864
2 pages 0.11 mb -
Indoor Fireplace
Avalon Stoves Black 95200132
1 pages 0.05 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Avalon Stoves Indoor Fireplace. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Avalon Stoves Indoor Fireplace ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Avalon Stoves Indoor Fireplace décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Avalon Stoves Indoor Fireplace devrait contenir:
- informations sur les caractéristiques techniques du dispositif Avalon Stoves Indoor Fireplace
- nom du fabricant et année de fabrication Avalon Stoves Indoor Fireplace
- instructions d'utilisation, de réglage et d’entretien de l'équipement Avalon Stoves Indoor Fireplace
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Avalon Stoves Indoor Fireplace ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Avalon Stoves Indoor Fireplace et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Avalon Stoves en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Avalon Stoves Indoor Fireplace, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Avalon Stoves Indoor Fireplace, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Avalon Stoves Indoor Fireplace. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
• Masonry Fireplace • Factory Built (Metal) Fireplace • Mobile Home Approved Tested and Listed by Omni-Test Laboratories, Inc. Portland, Oregon Report # 028–S–51-2 ASTME-1509 1995, ULCC 1482 Astoria Bay™ Pellet Insert - - Please read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follo[...]
-
Page 2
2 Introduction Travis Industries 4 0 5 0 5 2 5 1 00-01144 Introduction We welcome you as a new owner of a Astoria Bay pellet heater. In purchasing a Astoria Bay you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. The Astoria Bay is one of the fine[...]
-
Page 3
Table of Contents 3 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Introduction Introduction ......................................................2 Important Information .........................................2 Safety Precautions Safety Precautions ............................................4 Specifications Heating Specifications ..................[...]
-
Page 4
4 Safety Precautions Travis Industries 4 0 5 0 5 2 5 1 00-01144 • Do not operate the heater if you smell smoke coming from the heater. Turn the P OWER switch to "OFF", monitor your heater, and call your dealer. Ok • Contact your local building officials to obtain a permit and information on any installation restrictions or inspection [...]
-
Page 5
Safety Precautions 5 Travis Industries 4 0 5 0 5 2 5 1 00-01144 • The heater will not operate during a power outage. If a power outage does occur, check the heater for smoke spillage and open a window if any smoke spills into the room. • This heater must be connected to a standard 115 V., 60 Hz grounded electrical outlet. Do not use an adapter [...]
-
Page 6
6 Specifications Travis Industries 4 0 5 0 5 2 5 1 00-01144 Heating Specifications: Approximate Maximum Heating Capacity (in square feet)* ........................................ 800 to 2,250 Burn Rate (Pounds per Hour)** ............................................................................ 1.7 to 5.5 Maximum Burn Time on Low Burn** .......[...]
-
Page 7
Installation 7 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Before You Begin READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS HEATER. FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. Check with local building officials for any permits required for installation of this pellet heater and notify your[...]
-
Page 8
8 Installation Travis Industries 4 0 5 0 5 2 5 1 00-01144 Hopper Extension Set-up This pellet heater has a variable-height hopper. This allows the hopper to be lowered for smaller fireplaces. Follow the instructions below to set the correct hopper extension position. • Determine the correct hopper extension position following the directions below[...]
-
Page 9
Installation 9 Travis Industries 4 0 5 0 5 2 5 1 00-01144 • Remove the correct knock-outs in the hopper walls following the directions below. Use a center-punch (or other suitable tool) to remove the appropriate knock- outs in the hopper walls (punch the holes out from the inside). Make sure to support the hopper walls while removing the knock-ou[...]
-
Page 10
10 Installation Travis Industries 4 0 5 0 5 2 5 1 00-01144 Clearances • Insert must be placed so that no combustibles are within, or can swing within (e.g. drapes, doors), 36" of the front of the heater. • Insert must be placed a minimum 8-3/4" from a side wall (or combustible protruding more than 3/4"). Mantel Requirements • T[...]
-
Page 11
Installation 11 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Venting the Pellet Stove • INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER). • DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR STOVE. • DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT. • USE AN APPROVED WALL THIMBLE WHEN [...]
-
Page 12
12 Installation Travis Industries 4 0 5 0 5 2 5 1 00-01144 Mobile Home Requirements • Outside air is required (used for combustion) - see the directions below. WARNING: D O NOT INSTALL IN SLEEPING ROOM. CAUTION: THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED. Outside Air (used for combustion) ?[...]
-
Page 13
Installation 13 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Baffle Installation Install the baffles included with the insert (see page 28 for details). Restrictor Adjustment The restrictor is used to adjust airflow to the firepot. It should be adjusted to match the heat output setting and burn the pellets at the appropriate rate. This keeps the fire[...]
-
Page 14
14 Installation Travis Industries 4 0 5 0 5 2 5 1 00-01144 Surround Panel & Circuit Board Installation NOTE : Attach the vent prior to installing the surround panels (& circuit board). a Remove the circuit board from the rear hopper support. Disconnect the wiring harness from the circuit board (see step “ d ” below for a detailed view).[...]
-
Page 15
Installation 15 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Installation into a Masonry Fireplace “ L ” Vent Flex Section Outside air may be drawn from the ash cleanout. “ L ” Vent Storm Collar Vertical Cap Cover Plate (non-combustible) Silicone Seal the cover plate with silicone. HINT: Paint the interior of the fireplace with latex paint to[...]
-
Page 16
16 Installation Travis Industries 4 0 5 0 5 2 5 1 00-01144 Installation into a Factory Built (Metal) Fireplace “ L ” Vent Flex Section HINT: Paint the interior of the fireplace with latex paint to prevent fireplace odors from entering the home. “ L ” Vent Storm Collar Vertical Cap Cover Plate (non-combustible) Silicone Seal the cover plate [...]
-
Page 17
Operation 17 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Safety Notice • Read this entire manual (especially the "Safety Precautions" on pages 4 and 5) before using this heater. Failure to follow the instructions may result in property damage, bodily injury, or even death. • Do not unplug the heater to turn it off. This heater relies u[...]
-
Page 18
18 Operation Travis Industries 4 0 5 0 5 2 5 1 00-01144 Loading Pellets Lift the hopper lid to its vertical position. Pour pellets into the hopper until full. NOTE: The hopper holds approximately 48 to 88 pounds of pellets (depending upon hopper set-up). The front edge of the hopper lid becomes very hot, do not touch the area below the handle. Make[...]
-
Page 19
Operation 19 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Manual Mode Manual mode requires the user to turn the heater on and off manually. To Start Press the "Manual Start" button. That's it. The stove automatically goes to a medium burn rate and high fan while the igniter starts the fire burning within 10 minutes. During this period [...]
-
Page 20
20 Operation Travis Industries 4 0 5 0 5 2 5 1 00-01144 Auto Mode Auto mode allows you to use a thermostat to control room temperature. The stove automatically turns on when the temperature drops below the thermostat setting. Once the stove reaches operating temperature, the stove then runs at the heat output setting selected. To Adjust Room Temper[...]
-
Page 21
Operation 21 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Restrictor Adjustment The restrictor is used to adjust airflow to the firepot. It should be adjusted to match the heat output setting and burn the pellets at the appropriate rate. This keeps the firepot as clean as possible. For low heat output settings the restrictor will need to be closed or[...]
-
Page 22
22 Operation Travis Industries 4 0 5 0 5 2 5 1 00-01144 Start-Up Sequence This stove utilizes a start-up sequence whenever the mode switch is changed or the heater is started when cold. This is to ensure proper operation through all possible settings and operational states (hot or cold, pellets burning or not burning, etc.). This sequence over-ride[...]
-
Page 23
Operation 23 Travis Industries 4 0 5 0 5 2 5 1 00-01144 "MANUAL AUGER" Button This button turns the auger on. It is used to “ prime ” the auger after the hopper has run out of pellets. Power Outages If a sustained power outage occurs while in "Manual", the heater will go to a "cool down" mode to vacate smoke once p[...]
-
Page 24
24 Maintenance Travis Industries 4 0 5 0 5 2 5 1 00-01144 Daily Maintenance (whenever using the heater) Inspect the Burn When burning on high, the flames should be bright orange with embers jumping from the firepot. NOTE : the optimal restrictor position will vary over time as soot builds up inside the exhaust system. See "Restrictor Adjustmen[...]
-
Page 25
Maintenance 25 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Daily Maintenance (whenever using the heater) - Continued Check Firepot for Clinkers If the flames seem to be coming only from the sides, or are orange/black, turn the heater off and check for clinkers. The most likely causes are: • Restrictor needs adjustment (see “ Restrictor Adjustmen[...]
-
Page 26
26 Maintenance Travis Industries 4 0 5 0 5 2 5 1 00-01144 Daily Maintenance (whenever using the heater) - Continued Opening The Door Swing open this panel to access the door latch (use the tool if necessary). Phillips Screwdriver When securing the door, make sure the pawl fits over the bracket before tightening. NOTE : Do not overtighten the pawl. [...]
-
Page 27
Maintenance 27 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Weekly Maintenance (or every 5 bags of pellets) Flyash Removal This heater was designed to allow for easy flyash removal with the included tools. However, to ease maintenance, several pellet stove owners have purchased vacuums specifically made to remove flyash. Furthermore, some of these va[...]
-
Page 28
28 Maintenance Travis Industries 4 0 5 0 5 2 5 1 00-01144 Weekly Maintenance (or every 5 bags of pellets) - Continued Check Baffles, Ashbox, Ashpan, Dispose Ash If Necessary Removing the Ashpan The ashpan slides out from under the firebox. NOTE : When replacing the ash pan make sure it is pushed all the way in. Ashpan WARNING: The front of the heat[...]
-
Page 29
Maintenance 29 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Weekly Maintenance (or every 5 bags of pellets) - Continued Sweep Ash Into Ashpan HINT: The more often you clean out the flyash, the more efficient your heater will burn. NOTE: Remove the ashbox prior to conducting the service below. Swing the side ash trap door up. Lift it up and away from [...]
-
Page 30
30 Maintenance Travis Industries 4 0 5 0 5 2 5 1 00-01144 Yearly Maintenance (or every ton) WARNING: Disconnect the power cord prior to conducting service. The following section details extensive maintenance procedures. We strongly suggest these items be carried out by a trained service technician, possibly by a service agreement set up with your d[...]
-
Page 31
Maintenance 31 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Yearly Maintenance (or every ton) - Continued Clean the Exhaust Blower (make sure the heater is cool and unplugged) a Remove the surround panels and access the left side of the heater. Remove the shroud covering the blower motor. Remove the six screws holding the exhaust blower motor in plac[...]
-
Page 32
32 Maintenance Travis Industries 4 0 5 0 5 2 5 1 00-01144 Yearly Maintenance (or every ton) - Continued Door Seal ! Air leaks into the firebox will decrease the stove's performance greatly, leading to excessive sooting, inefficient burning, and perhaps a malfunction. • The door gasket must contact the entire perimeter of the door and create [...]
-
Page 33
Maintenance 33 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Yearly Maintenance (or every ton) - Continued Adjusting the Door Hinge and Latch • The door hinge and door latches may be adjusted to pull the door closer to the body. The illustration below details how to adjust these components. NOTE: Make sure to read the section "Door Alignment&qu[...]
-
Page 34
34 Maintenance Travis Industries 4 0 5 0 5 2 5 1 00-01144 Yearly Maintenance (or every ton) - Continued Check for Air Leaks Around the Door, Glass, and Ashpan ! Air leaks into the firebox will decrease the stove's performance greatly, leading to excessive sooting, inefficient burning, and perhaps a malfunction. • Inspect the door gasket to m[...]
-
Page 35
Normal Operating Sounds 35 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Auger Motor When feeding pellets, you may hear the intermittent buzz of this motor running. Covection Fan The modern high efficiency fan may produce a low hum, particularly on "HIGH". This sound will change as the FAN dial is turned. Heat Exchanger Tubes You may hear th[...]
-
Page 36
36 Safety Label Travis Industries 4 0 5 0 5 2 5 1 00-01144 Minimum Clearance to Combustible Materials (Measured from insert top) Adjacent Sidewall A 8.75 in Mantel B 11.5 in T op Facing C 6.25 in Side Facing D 7 in W ARNING - DO NOT REMOVE OR COVER THIS LABEL Listed Pelletized Solid Fuel Burning Appliance For use in masonry or factory built (ZC) fi[...]
-
Page 37
Limited 7 Year Warranty 37 Travis Industries 4 0 5 0 5 2 5 1 00-01144 To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd. SW, Mukilteo, WA 98275. TRAVIS INDUSTRIES, INC. warrants this gas a[...]
-
Page 38
38 Optional Equipment Travis Industries 4 0 5 0 5 2 5 1 00-01144 Thermostat (Part # 99300650) ! Do not connect 120 VAC to the thermostat circuit of this heater (do not use a household thermostat used for a wall-board or other electical heater). 1 Attach the thermostat wire to the circuit board (see the illustration to the right). Route the wire thr[...]
-
Page 39
Optional Equipment 39 Travis Industries 4 0 5 0 5 2 5 1 00-01144 ZC Kit (99200149) The optional zc kit allows this insert to be directly into the framing of a house or mobile home. See the kit for installation details. Floor Protection Wall Thimble (note 3 ” clearance between vent and combustibles) 12 ” Minimum Enclosure Height (measure from to[...]
-
Page 40
40 Index Travis Industries 4 0 5 0 5 2 5 1 00-01144 Adjusting the Fan Speed ......................................2 1 Air Leaks ..........................................................3 2 Ashpan (Opening and Disposing Ashes) .................2 8 AUGER ON Light ................................................2 2 Auto Mode .........................[...]