Black Box DB9F/RJ-11 (IC623A-F) manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 37 pages
- 0.14 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Network Hardware
Black Box ET0010A
88 pages 4.27 mb -
Network Hardware
Black Box AC650A-2-UK
16 pages 0.17 mb -
Network Hardware
Black Box 8x8 DVI-D Matrix Switches
24 pages 1.03 mb -
Network Hardware
Black Box ACU5011A
64 pages 0.84 mb -
Network Hardware
Black Box RM517
2 pages 0.04 mb -
Network Hardware
Black Box ME800A-R2
27 pages 0.09 mb -
Network Hardware
Black Box RM1400A
2 pages 0.14 mb -
Network Hardware
Black Box LE1502AE-R4
56 pages 0.24 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Black Box DB9F/RJ-11 (IC623A-F). Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Black Box DB9F/RJ-11 (IC623A-F) ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Black Box DB9F/RJ-11 (IC623A-F) décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Black Box DB9F/RJ-11 (IC623A-F) devrait contenir:
- informations sur les caractéristiques techniques du dispositif Black Box DB9F/RJ-11 (IC623A-F)
- nom du fabricant et année de fabrication Black Box DB9F/RJ-11 (IC623A-F)
- instructions d'utilisation, de réglage et d’entretien de l'équipement Black Box DB9F/RJ-11 (IC623A-F)
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Black Box DB9F/RJ-11 (IC623A-F) ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Black Box DB9F/RJ-11 (IC623A-F) et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Black Box en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Black Box DB9F/RJ-11 (IC623A-F), comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Black Box DB9F/RJ-11 (IC623A-F), l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Black Box DB9F/RJ-11 (IC623A-F). À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
MARCH 1998 IC620A-F IC623A-M IC620A-M IC624A-F IC623A-F IC624A-M RS-232/485 Con verter CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation , 1000 Park Drive, Law[...]
-
Page 2
1 FCC AND IC STATEMENTS FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communi- cation. It[...]
-
Page 3
2 RS-232/485 CONVERTER NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT INSTRUCCIONES DE SEGURIDAD 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3. Todas las advertenci[...]
-
Page 4
3 NOM STATEMENT 10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor . 11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indi[...]
-
Page 5
4 RS-232/485 CONVERTER TRADEMARKS Product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged.[...]
-
Page 6
5 TABLE OF CONTENTS CONTENTS 1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . .6 2. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . .8 2.1 Description . . . . . . . . . . . . . . . . . . . . . . .8 2.2 Features . . . . . . . . . . . . . . . . . . . . . . . . .9 3. Configuration . . . . . . . . . . . . . . . . . . .[...]
-
Page 7
6 RS-232/485 CONVERTER 1. Specifications Transmission Format — Asynchronous Data Rate — Up to 115,200 bps Range — Up to 9 miles (14.4 km) Serial Interface — EIA/TIA-574 standard RS-232 DCE Connectors — IC620A-F: (1) DB9 female, (1) 5-position terminal block, IC620A-M: (1) DB9 male, (1) 5-position terminal block; IC623A-F : (1) DB9 female,[...]
-
Page 8
7 CHAPTER 1: Specifications CTS turns ON after the terminal raises RTS RTS/CTS Delay — 8 msec or “no delay” Carrier — The carrier is switch-selected either continuous operation or switched operation, controlled by RTS Surge Protection — 600 W power dissipation at 1 ms Temperature — 32 to 122°F (0 to 50°C) Humidity — 5 to 95%, noncon[...]
-
Page 9
8 RS-232/485 CONVERTER 2. Introduction 2.1 Description The RS-232/485 Converter (IC620A) is an ultra- miniature interface converter. Requiring no AC power or batteries for operation, the Converter supports asynchronous communication up to 115.2 Kbps over one or two unconditioned twisted pairs. Distances up to 15 miles (24 km) are attainable at lowe[...]
-
Page 10
9 CHAPTER 2: Introduction Six models are available: • DB9F/Term (IC620A-F) • DB9M/Term (IC620A-M) • DB9F/RJ-11 (IC623A-F) • DB9M/RJ-11 (IC623A-M) • DB9F/RJ-45 (IC624A-F) • DB9F/RJ-45 (IC624A-M) 2.2 Features • Operates asynchronously, point-to-point or multipoint, over 2 or 4 wires. • Up to 31 multipoint device drops in a polling env[...]
-
Page 11
10 RS-232/485 CONVERTER • Twisted-pair connection via strain relief, RJ-11, or RJ-45. • Silicon Avalanche Diode surge protection. • A Transmitter On signal received at the RS-485 RCV connection will cause DCD output at the RS-232 connector to assert High.[...]
-
Page 12
11 CHAPTER 3: Configuration 3. Configuration The Converter is configured using two internal 4-position DIP switches. This section shows how to access the DIP switches, provides an overview of the factory-default settings, and describes all possible configuration options. For instructions on how to configure the Converter for specific applications, [...]
-
Page 13
12 RS-232/485 CONVERTER Figure 3-1. Underside of the Converter’s main PC board, showing the location of DIP switch S1. Switch S1[...]
-
Page 14
13 CHAPTER 3: Configuration Figure 3-2. Top of the Converter’s daughterboard, showing the location of DIP switch S2. Switch S2 RCV XMT G - ++ -[...]
-
Page 15
14 RS-232/485 CONVERTER To access the Converter’s internal PC boards, insert a small flat-blade screwdriver between the connector and the lip of the case and twist gently as shown in Figure 3-3 . Figure 3-3. Opening the Converter’s plastic case with a small screwdriver.[...]
-
Page 16
15 CHAPTER 3: Configuration Both DIP switch S1 and S2 are marked with individual switch numbers 1 through 4. Use these numbers, and the “ON” designation to orient the switch properly (see Figure 3-4 ). Use a small screwdriver or similar instrument to set each individual switch. 1 2 3 4 ON ON OFF Figure 3-4. Close-up of DIP switches S1 and S2, s[...]
-
Page 17
16 RS-232/485 CONVERTER 3.1.1 DIP S WITCH S1 S ETTINGS DIP switch S1 is used to configure receive impedance (termination), 2-wire/4-wire operation and “echo” enable/disable. Table 3-1 shows the factory-default settings for switch S1. Following Table 3-1 is a detailed description of each switch. Table 3-1. Switch S1 Summary Table (factory defaul[...]
-
Page 18
17 CHAPTER 3: Configuration S1-1: Receive Impedance (Termination) The setting for switch S1-1 selects the impedance of the input receiver. You may select either a “low” impedance of 120 ohms or a “high” impedance of 16 K ohms. By selecting the proper impedance for each drop, you can have up to 50 receivers in one application. S1-1 Setting O[...]
-
Page 19
18 RS-232/485 CONVERTER S1-4: Echo Mode The setting for switch S1-4 determines whether the Converter echoes data back to the transmitting device (half-duplex mode only). S1-4 Setting On Echo On Off Echo Off 3.1.2 DIP S WITCH S2 S ETTINGS DIP switch S2 is used to configure carrier control, RTS/CTS delay, and communication protocol. Table 3-2 shows t[...]
-
Page 20
19 CHAPTER 3: Configuration S2-1: Carrier Control Method The setting for S2-1 determines whether the carrier is “Constantly On” or “Controlled by RTS.” This allows for operation in switched carrier, multipoint, and/or hardware handshaking applications. S2-1 Setting On Controlled by RTS Off Constantly On NOTE When in Controlled mode, RTS mus[...]
-
Page 21
20 RS-232/485 CONVERTER S2-3 and S2-4: “Transmit Off” Impedance Switches S2-3 and S2-4 are set together to determine whether the receiving device “sees” the impedance of the Converter’s transmitter as being “high” or “intermediate” when the transmitter is turned off. The “intermediate” setting is useful in half-duplex environm[...]
-
Page 22
21 CHAPTER 3: Configuration The switch settings generally needed to configure the Converter for these applications are shown in Table 3-3 . NOTE Do not change switch settings until you have carefully read Section 3.1 . Table 3-3. Typical Converter Applications Switch Point-to-Point Multipoint Settings 4W 4W HDX 2W 4W 2W S1-1: Rcv impedance ON ON ON[...]
-
Page 23
22 RS-232/485 CONVERTER 4. Installation Once the Converter is properly configured, it is ready to connect to your system. This section tells you how to properly connect the Converter to the twisted-pair and EIA/TIA-574 interfaces, and how to operate the Converter. 4.1 Twisted-Pair Connection The Converter supports 2-wire or 4-wire communi- cation b[...]
-
Page 24
23 CHAPTER 3: Configuration For your convenience, the Converter is available with several different twisted-pair interfaces: RJ-11 jack, RJ-45 jack, and terminal blocks with strain relief. The Converter is also available with DB25 male or female connectors. 4.1.1 T WISTED -P AIR C ONNECTIONS U SING T ERMINAL B LOCKS If your application requires you[...]
-
Page 25
24 RS-232/485 CONVERTER 3. Strip the insulation on each of the twisted- pair wires about 1⁄8 inch. Figure 4-2. Stripping the insulation on the twisted-pair wires. 4. In a two-pair circuit, connect one pair of wires to XMT+ and XMT- (transmit positive and negative) on the terminal block, making careful note of which color is positive and which col[...]
-
Page 26
25 CHAPTER 3: Configuration XMT+----------------------------------------RCV+ XMT- --------------------------------------- RCV- G-------------To Shield (Optional) G RCV+-----------------------------------------XMT+ RCV - ----------------------------------------XMT- Figure 4-3. Two-Pair Crossover Cable. 6. In a single-pair circuit, use only the trans[...]
-
Page 27
26 RS-232/485 CONVERTER Figure 4-5. Wires connected to the terminal block. 8. Place the two halves of the strain-relief assembly on either side of the telephone wire and press together very lightly. Slide the assembly so that it is about two inches from the terminal posts and press together firmly. If your cable diameter is too small or too large f[...]
-
Page 28
27 CHAPTER 3: Configuration 9. Insert the strain-relief assembly with the wire going through it into the slot in the bottom half of the modem case and seat it into the recess in the case. (If the telephone wire is too thin to be held by the strain-relief assembly, you will need to order a different-sized strain relief. Call for technical support.) [...]
-
Page 29
28 RS-232/485 CONVERTER 10. Bend the top of the case as necessary to place it over the strain-relief assembly. Do not snap the case together yet. Figure 4-8. Closing the case. 11. Insert one captive screw through a saddle washer and then insert the captive screw, with the washer on it, through the hole in the DB25 end of the case. Snap that side of[...]
-
Page 30
29 CHAPTER 3: Configuration 4.1.2 T WISTED -P AIR C ONNECTION U SING RJ-11 OR RJ-45 The RJ-11 and RJ-45 connectors on the Converter’s twisted-pair interface are pre-wired for a standard telco wiring environment. The signal/pin relationships are shown in Figure 4-9 . RJ-11 Signal RJ-45 Signal 1--------------GND 1 1---------------N/C 2-------------[...]
-
Page 31
30 RS-232/485 CONVERTER Signal Pin# Pin# Signal GND 1 1--------------6 GND 1 RCV- 2--------------4 XMT- XMT+ 3--------------5 RCV+ XMT- 4--------------2 XMT+ RCV+ 5--------------3 XMT+ GND 1 6--------------1 GND 1 1 Connection to ground is optional. Figure 4-10. RJ-11 Cable (4-wire). Signal Pin# Pin# Signal GND 1 2--------------7 GND 1 RCV- 3------[...]
-
Page 32
31 CHAPTER 3: Configuration Signal Pin# Pin# Signal XMT+ 3---------------3 XMT+ XMT- 4---------------4 XMT- Figure 4-12. RJ-11 Cable (2-wire). Signal Pin# Pin# Signal XMT+ 4--------------4 XMT+ XMT- 5--------------5 XMT- Figure 4-13. RJ-45 Cable (2-wire). 4.2 Wiring for Multipoint Circuits The Converter supports multipoint applications using a dais[...]
-
Page 33
32 RS-232/485 CONVERTER D AISYCHAIN T OPOLOGY Using a daisychain topology, you may connect several Converters together in a master/slave arrangement. Maximum distance between the units will vary based upon the number of drops, data rate, wire gauge, etc. Call Technical Support for specific distance estimates. Figure 4-14 shows how to wire the two-p[...]
-
Page 34
33 CHAPTER 3: Configuration 4.3 Connection to the EIA/TIA-574 Interface The Converter is designed to plug directly into the DB9 serial port of an EIA/TIA-574 DTE device (PC, laptop, host). If you must use a cable to connect the Converter to the DTE device, make sure that it is a straight-through cable of the shortest possible length—we recommend [...]
-
Page 35
34 RS-232/485 CONVERTER 4.4 Operating the Converter Once the Converter is properly installed, it should operate transparently — as if it were a standard cable connection. Operating power is derived from the RS-232 data and control signals; there is no ON/OFF switch. All data signals from the RS-232 and RS-485 interfaces are passed straight throug[...]
-
Page 36
35 APPENDIX Appendix: EIA/TIA-574 Interface DB9 Signal Direction 1----------------------CD Output 2----------------------RD Output 3----------------------TD Input 4----------------------DTR Input 5---------------------- SG/FG — — — 6----------------------DSR Output 7----------------------RTS Input 8----------------------CTS Output 9----------[...]
-
Page 37
1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746 © Copyright 1998. Black Box Corporation. All rights reserved.[...]