Bosch Appliances D9412GV2 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 74 pages
- 1.88 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Home Security System
Bosch Appliances LTC 4600
20 pages 0.62 mb -
Home Security System
Bosch Appliances LTC 9384/00
2 pages 0.14 mb -
Home Security System
Bosch Appliances D9412G
142 pages 5.64 mb -
Home Security System
Bosch Appliances D625
48 pages 1.32 mb -
Home Security System
Bosch Appliances 600
32 pages 3.79 mb -
Home Security System
Bosch Appliances XLA 3200
160 pages 9.54 mb -
Home Security System
Bosch Appliances D1260B
100 pages 2.11 mb -
Home Security System
Bosch Appliances VIP X2
144 pages 2.84 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Bosch Appliances D9412GV2. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Bosch Appliances D9412GV2 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Bosch Appliances D9412GV2 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Bosch Appliances D9412GV2 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Bosch Appliances D9412GV2
- nom du fabricant et année de fabrication Bosch Appliances D9412GV2
- instructions d'utilisation, de réglage et d’entretien de l'équipement Bosch Appliances D9412GV2
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Bosch Appliances D9412GV2 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Bosch Appliances D9412GV2 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Bosch Appliances en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Bosch Appliances D9412GV2, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Bosch Appliances D9412GV2, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Bosch Appliances D9412GV2. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
EN Operation and Installation Guide Control Panels D9412GV2/D7412GV2[...]
-
Page 2
D9412GV2/D7412GV2 | Operation and Installation Guide | Trademarks 2 Bosch Security Systems, Inc. | 5/05 | F01U003641B Trademarks CoBox is a registered trademark of Lantronix ® . Windows ® is a registered trademark of Microsoft Corporation in the United States or in other countries. Molex ® is a registered trademark of Molex Incorporated. Cer[...]
-
Page 3
D9412GV2/D7412GV2 | Operation and Installation Guide | Federal Communications Commission (FCC) Rules . Bosch Security Systems, Inc. | 5/05 | F01U003641B 3 If the D9412GV2 or D7412GV2 Control Panel causes harm to the telephone network, the telephone company attempts to notify you in advance. If advance notice is not practical, the telephone company [...]
-
Page 4
D9412GV2/D7412GV2 | Operation and Installation Guide | Contents 4 Bosch Security Systems, Inc. | 5/05 | F01U003641B Contents 1.0 Introduction ....................................................... 7 2.0 Lightning Strikes .............................................. 8 2.1 Effects ...................................................................[...]
-
Page 5
D9412GV2/D7412GV2 | Operation and Installation Guide | . Bosch Security Systems, Inc. | 5/05 | F01U003641B 5 8.5 Wiring Information for Installations Using the Ademco AB-12 Bell/Housing........ 32 9.0 Off-Board Points ............................................. 34 9.1 Point (Zonex) Bus: D9412GV2 Terminals and D7412GV2 Terminals ..................[...]
-
Page 6
D9412GV2/D7412GV2 | Operation and Installation Guide | 1.0 Introduction 6 Bosch Security Systems, Inc. | 5/05 | F01U003641B Figures Figure 1: System Configuration ................................. 9 Figure 2: Enclosure Mounting .................................. 15 Figure 3: Ground Fault Detection ............................ 16 Figure 4: Reset Pin[...]
-
Page 7
D9412GV2/D7412GV2 | Operation and Installation Guide | Tables . Bosch Security Systems, Inc. | 5/05 | F01U003641B 7 1 .0 Int roduct ion This manual addresses the operation and installation of the D9412GV2 and D7412GV2 Control Panels. Throughout this guide, the words “control panel” refer to both control panels (D9412GV2 and D7412GV2). Table 2 o[...]
-
Page 8
D9412GV2/D7412GV2 | Operation and Installation Guide | 2.0 Lightning Strikes 8 Bosch Security Systems, Inc. | 5/05 | F01U003641B 2.0 Light ning St rikes The control panels are designed to significantly reduce electromagnetic interference and malfunction generally caused by lightning. 2.1 Effects Any electronic system can be struck directly by light[...]
-
Page 9
D9412GV2/D7412GV2 | Operation and Installation Guide | 3.0 Overview . Bosch Security Systems, Inc. | 5/05 | F01U003641B 9 3.0 Overview 3.1 Configuration and Parts Figure 1: System Configuration Use keypads or keyswitches to arm the control panel by area. Each control panel can have up to eight areas. Each area can have its own account number or are[...]
-
Page 10
D9412GV2/D7412GV2 | Operation and Installation Guide | 3.0 Overview 10 Bosch Security Systems, Inc. | 5/05 | F01U003641B 3.1.1 Parts List The D9412GV2 andD7412GV2 Control Panels are shipped assembled from the factory with the following parts: Literature Pack • D9412GV2/D7412GV2/D7212GV2 Installation and Troubleshooting Quick Reference Guide (P/N:[...]
-
Page 11
D9412GV2/D7412GV2 | Operation and Installation Guide | 3.0 Overview . Bosch Security Systems, Inc. | 5/05 | F01U003641B 11 3.2 Accessories Refer to the Bosch Security Systems product catalog for additional information. Table 3: Compatible Accessories Model Title Model Title D122/D122L Dual Battery Harness D1260 Alpha V Command Center D125B Powered [...]
-
Page 12
D9412GV2/D7412GV2 | Operation and Installation Guide | 3.0 Overview 12 Bosch Security Systems, Inc. | 5/05 | F01U003641B 3.3 Features in the D9412GV2 and D7412GV2 3.3.1 SDI Molex Connector Use the SDI Molex Connector to connect easily an SDI device with the SDI bus, without needing to disconnect wires connected to the SDI terminals. Possible applic[...]
-
Page 13
D9412GV2/D7412GV2 | Operation and Installation Guide | 3.0 Overview . Bosch Security Systems, Inc. | 5/05 | F01U003641B 13 The system can route groups of Event Reports to four different destinations. Each report group can be programmed to send reports to one or more destinations. Primary and backup reporting paths can be programmed for each destina[...]
-
Page 14
D9412GV2/D7412GV2 | Operation and Installation Guide | 3.0 Overview 14 Bosch Security Systems, Inc. | 5/05 | F01U003641B 3.3.15 NetCom Functions The D6600 NetCom System supports data network communications. NetCom allows the D6600 receiver to connect to various network topologies, specifically Ethernet and token-ring. NetCom also allows this receiv[...]
-
Page 15
D9412GV2/D7412GV2 | Operation and Installation Guide | 4.0 Installation . Bosch Security Systems, Inc. | 5/05 | F01U003641B 15 4.0 Inst allat ion 4.1 Installation Preparation This section contains a general installation procedure and refers to other sections of the document for detailed instructions. Review this document and the D9412GV2/D7412GV2 P[...]
-
Page 16
D9412GV2/D7412GV2 | Operation and Installation Guide | 4.0 Installation 16 Bosch Security Systems, Inc. | 5/05 | F01U003641B 4.4 Installing the Control Panel 1. Place the control panel over the inside back of the enclosure, aligning the large rectangular openings of the mounting skirt with the mounting hooks of the enclosure. Slide the control pane[...]
-
Page 17
D9412GV2/D7412GV2 | Operation and Installation Guide | 4.0 Installation . Bosch Security Systems, Inc. | 5/05 | F01U003641B 17 4.5.3 Enabling Ground Fault Detection To configure the D9412GV2 and D7412GV2 Control Panels to enable ground fault detection: 1. Set the silent relay in Area 5 to any value from 1 to 128. Do not use a zero (0) value. The de[...]
-
Page 18
D9412GV2/D7412GV2 | Operation and Installation Guide | 4.0 Installation 18 Bosch Security Systems, Inc. | 5/05 | F01U003641B 4.6 Completing the Installation If not already complete, make the earth ground connection to Terminal 10 and lock the reset pin in the closed position. 4.6.1 Charging the Battery Connect the battery, then the transformer to a[...]
-
Page 19
D9412GV2/D7412GV2 | Operation and Installation Guide | 4.0 Installation . Bosch Security Systems, Inc. | 5/05 | F01U003641B 19 4.7 Programming the Control Panel If the control panel is not already programmed, review the D9412GV2/D7412GV2 Program Entry Guide (P/N: F01U003636). Ensure that all accessory modules for desired features are available for [...]
-
Page 20
D9412GV2/D7412GV2 | Operation and Installation Guide | 5.0 Power Supply 20 Bosch Security Systems, Inc. | 5/05 | F01U003641B 5.0 P ower Supply 5.1 Primary Power Terminals 1 and 2 5.1.1 Primary (AC) Power Circuit The primary source is a 16.5 VAC, 40 VA, internally- fused transformer (Bosch Security Systems Model D1640). The control panel draws 200 m[...]
-
Page 21
D9412GV2/D7412GV2 | Operation and Installation Guide | 5.0 Power Supply . Bosch Security Systems, Inc. | 5/05 | F01U003641B 21 5.2.2 Installing the Battery 1. Place the battery upright in the base of the enclosure. 2. Locate the red and black leads supplied in the literature pack. 3. Connect the black battery lead to Terminal 4, and then to the neg[...]
-
Page 22
D9412GV2/D7412GV2 | Operation and Installation Guide | 5.0 Power Supply 22 Bosch Security Systems, Inc. | 5/05 | F01U003641B Figure 5: Non-Power-Limited Wiring EARTH GROUND COMM ON BATT ERY NEG ATI Maximum Charging Curren t 1.4 Amps. BA TTERY POSI TIVE ONL Y RELA Y A RELA Y B RELA Y C + AUX PROGRAMMA BLE ALARM O UTPU TS Term in al s Requires Opt io[...]
-
Page 23
D9412GV2/D7412GV2 | Operation and Installation Guide | 5.0 Power Supply . Bosch Security Systems, Inc. | 5/05 | F01U003641B 23 5.2.4 Battery Supervision When battery voltage drops to 13.8 VDC, the yellow Charging Status LED illuminates. When the battery voltage drops to 12 VDC to 11.8 VDC, the red Low Battery LED lights, and the keypad or keypads d[...]
-
Page 24
D9412GV2/D7412GV2 | Operation and Installation Guide | 5.0 Power Supply 24 Bosch Security Systems, Inc. | 5/05 | F01U003641B Table 8: Charging Status and Low Battery LEDs LED Type Color State Action Charging Status LED Yellow Shows the changing status of the battery. Refer to Figure 6 on page 23 for location. Yellow Off Battery is fully charged. If[...]
-
Page 25
D9412GV2/D7412GV2 | Operation and Installation Guide | 6.0 Power Outputs . Bosch Security Systems, Inc. | 5/05 | F01U003641B 25 6.0 P ower Out put s 6.1 Circuit Protection Three Positive Temperature Coefficients (PTCs) protect the control panel from short circuits on the continuous and programmable power outputs. If the control panel is programmed [...]
-
Page 26
D9412GV2/D7412GV2 | Operation and Installation Guide | 6.0 Power Outputs 26 Bosch Security Systems, Inc. | 5/05 | F01U003641B 6.4.2 Terminals 6 and 7 When activated, Terminals 6 (Relay A) and 7 (Relay B), provide positive (+) 10.2 VDC to 13.9 VDC power output. Use the power at Terminals 6 and 7 to power bells, siren drivers, piezoelectric fire soun[...]
-
Page 27
D9412GV2/D7412GV2 | Operation and Installation Guide | 7.0 Telephone Connections . Bosch Security Systems, Inc. | 5/05 | F01U003641B 27 7 .0 T elephone Connect ions 7.1 Registration The Bosch Security Systems D9412GV2/D7412GV2 Control Panels are registered with the Federal Communication Commission (FCC) under Part 68, for connection to the public t[...]
-
Page 28
D9412GV2/D7412GV2 | Operation and Installation Guide | 7.0 Telephone Connections 28 Bosch Security Systems, Inc. | 5/05 | F01U003641B 7.5 Phone LED (Red) The red Phone LED illuminates when the control panel seizes the telephone line and remains illuminated until the control panel returns the telephone line. Refer to Figure 8 on page 27 for the loca[...]
-
Page 29
D9412GV2/D7412GV2 | Operation and Installation Guide | 7.0 Telephone Connections . Bosch Security Systems, Inc. | 5/05 | F01U003641B 29 7.11 D928 Dual Phone Line Switcher 7.11.1 Description The optional D928 Dual Phone Line Switcher allows the control panel to send reports over two separate telephone lines. The control panel monitors both lines. If[...]
-
Page 30
D9412GV2/D7412GV2 | Operation and Installation Guide | 7.0 Telephone Connections 30 Bosch Security Systems, Inc. | 5/05 | F01U003641B 7.11.3 Installing the D928 Mounting Mount the D928 on the lower right side of the enclosure using the screws provided with the switcher. Wiring The D928 has two flying leads. The green lead monitors AC power. The bla[...]
-
Page 31
D9412GV2/D7412GV2 | Operation and Installation Guide | 8.0 On-Board Points . Bosch Security Systems, Inc. | 5/05 | F01U003641B 31 8.0 On-Board Points 8.1 Terminals 11 to 22 Description The control panel provides eight on-board points. Each point functions independently and does not interfere with the operation of the others. The control panel monit[...]
-
Page 32
D9412GV2/D7412GV2 | Operation and Installation Guide | 8.0 On-Board Points 32 Bosch Security Systems, Inc. | 5/05 | F01U003641B 8.4 Point Response Time The control panel scans both on-board and off-board point sensor loops every 300 ms. The Debounce program item in the Point Assignment section of the software determines point response time by setti[...]
-
Page 33
D9412GV2/D7412GV2 | Operation and Installation Guide | 8.0 On-Board Points . Bosch Security Systems, Inc. | 5/05 | F01U003641B 33 Figure 11: Wiring for Installation Using the Ademco AB-12 Bell/Housing 1 2 3 4 5 6 EART H GROUND COMMON BATTER Y NEGATIV E ON L Y Maxim um Char ging Curr ent 1.4 Amp s. BA TTERY POSITIVE ONL Y RELA Y A RELA Y B RELA Y C [...]
-
Page 34
D9412GV2/D7412GV2 | Operation and Installation Guide | 9.0 Off-Board Points 34 Bosch Security Systems, Inc. | 5/05 | F01U003641B 9.0 Off-Board Points 9.1 Point (Zonex) Bus: D9412GV2 Terminals and D7412GV2 Terminals 9.1.1 POPIT Modules The D9412GV2 can use point of protection input transponder (POPIT) modules to provide a maximum of 238 off-board po[...]
-
Page 35
D9412GV2/D7412GV2 | Operation and Installation Guide | 9.0 Off-Board Points . Bosch Security Systems, Inc. | 5/05 | F01U003641B 35 Table 13: Off-Board Point Errors Error Condition Result Additional Information +/- leg of the data expansion bus has a short-circuit to earth ground, with Ground Fault Detect enabled Ground Fault event +/- leg of the da[...]
-
Page 36
D9412GV2/D7412GV2 | Operation and Installation Guide | 9.0 Off-Board Points 36 Bosch Security Systems, Inc. | 5/05 | F01U003641B Figure 12: Connecting the D8125 POPEX to the D9412GV2 Control Panel Reset Pin Disa ble All E xcept B attery Charging A nd Progr amming PERIPHERAL DEVICE CONNECTIONS RED POWER + YELLOW DA T A BUS A GREEN DAT A BUS B BLACK [...]
-
Page 37
D9412GV2/D7412GV2 | Operation and Installation Guide | 9.0 Off-Board Points . Bosch Security Systems, Inc. | 5/05 | F01U003641B 37 Figure 13: Connecting the D8125 POPEX to the D7412GV2 Panel (-) (-) (+) (+) AUX IN OUT GND EARTH GRO COMMON BATT ERY N Maximum Chargin g Current 1 .4 Amps. BATTERY POSITIVE ONLY RELAY A RELAY B RELAY C + AUX PO 1 2 3 4 [...]
-
Page 38
D9412GV2/D7412GV2 | Operation and Installation Guide | 9.0 Off-Board Points 38 Bosch Security Systems, Inc. | 5/05 | F01U003641B 9.3 Installing the D8125 POPEX Module For information on the Multiplex Bus Interface, refer to the D8125 Multiplex Bus Interface Operation and Installation Guide (P/N: 36796). Save the POPIT Label Sheets: The D8125 is pac[...]
-
Page 39
D9412GV2/D7412GV2 | Operation and Installation Guide | 9.0 Off-Board Points . Bosch Security Systems, Inc. | 5/05 | F01U003641B 39 9.3.4 Wiring Data Expansion Loops to POPEX Modules Each POPEX Module has two positive (+) and two negative (-) data expansion loop terminals. Up to 119 POPITs can be connected to one D8125 on the D9412GV2; 67 for the D7[...]
-
Page 40
D9412GV2/D7412GV2 | Operation and Installation Guide | 9.0 Off-Board Points 40 Bosch Security Systems, Inc. | 5/05 | F01U003641B Figure 14: Program Record Sheet EN | 25 bold P oint Assi gnments ( 0 0 1 t hrough 04 0) POPIT Switch Settin g T rans- lation Poi nt # Point Index Area Assign Debounce BFSK/ Relay Custo m Point T ext 100 001 ( 3) _ _ (1) _[...]
-
Page 41
D9412GV2/D7412GV2 | Operation and Installation Guide | 9.0 Off-Board Points . Bosch Security Systems, Inc. | 5/05 | F01U003641B 41 The D8128D is also suitable for fire supervisory applications, such as indicating circuit supervision (using the D192C/D192G Bell Circuit Supervision Module), sprinkler supervision, and valve tamper protection. Requirem[...]
-
Page 42
D9412GV2/D7412GV2 | Operation and Installation Guide | 9.0 Off-Board Points 42 Bosch Security Systems, Inc. | 5/05 | F01U003641B Table 15: D8128D OctoPOPIT Switch Settings for D9412GV2 and D7412GV2 ZONEX 1 D8128D Address Switches ZONEX 2 Points 9 to 127 1 2 3 4 5 Points 129 to 247 9 to 16 ON ON ON ON * 129 to 136 17 to 24 ON ON ON OFF * 137 to 144 [...]
-
Page 43
D9412GV2/D7412GV2 | Operation and Installation Guide | 9.0 Off-Board Points . Bosch Security Systems, Inc. | 5/05 | F01U003641B 43 A D8128D OctoPOPIT can be installed up to 61 m (200 ft.) from the control panel. 2. Connect the D8128D to the control panel: • Wire the D8128D to the terminal strip on the side of the POPEX Module (), or • Connect t[...]
-
Page 44
D9412GV2/D7412GV2 | Operation and Installation Guide | 9.0 Off-Board Points 44 Bosch Security Systems, Inc. | 5/05 | F01U003641B Figure 16: Connecting D8128D OctoPOPITs to the D9412GV2 Reset Pin Disable All Except Battery Charging And Programming PERIPHERAL DEVICE CONNECTI ONS RED POWER + YELLOW DAT A BUS A GREEN DAT A BUS B BLACK COM MON ZONEX OU [...]
-
Page 45
D9412GV2/D7412GV2 | Operation and Installation Guide | 9.0 Off-Board Points . Bosch Security Systems, Inc. | 5/05 | F01U003641B 45 Figure 17: Connecting D8128D OctoPOPITs to the D7412GV2 Pin Battery ammin g E CONNECT IONS POWER + DAT A BUS A DAT A BUS B COMMON ZONEX O UT 1 ZO NEX IN 1 32 31 30 29 28 27 NOT USED 26 25 NOT USED NEX POWER + 24 COMMON [...]
-
Page 46
D9412GV2/D7412GV2 | Operation and Installation Guide | 9.0 Off-Board Points 46 Bosch Security Systems, Inc. | 5/05 | F01U003641B Using Molex ® Connectors Each D8128D Module is supplied with a 30 cm (12 in.) female-to-female Molex cable assembly. P1 and P2 are Molex connectors that parallel the COM, IN, OUT, and +12 VDC terminals on the terminal st[...]
-
Page 47
D9412GV2/D7412GV2 | Operation and Installation Guide | 9.0 Off-Board Points . Bosch Security Systems, Inc. | 5/05 | F01U003641B 47 Figure 19: D8128D OctoPOPIT Sensor Loops COM IN OUT+12V P1 COM P2 P3 COM P4 P5 C OM P6 P7 COM P8 1 2 3 4 5 1 - D8128D OctoPOPIT 2 - To control panel 3 - To additional OctoPOPIT sensor loops 4 - OctoPOPIT sensor loops 5 [...]
-
Page 48
D9412GV2/D7412GV2 | Operation and Installation Guide | 10.0 Off-Board Relays 48 Bosch Security Systems, Inc. | 5/05 | F01U003641B 1 0.0 Off- Board Relays 10.1 D8129 OctoRelay Use the D8129 OctoRelay to add relay outputs to the system in groups of eight. On the D9412GV2, up to 128 OctoRelay outputs (relay numbers 1 to 128) can be added to the system[...]
-
Page 49
D9412GV2/D7412GV2 | Operation and Installation Guide | 10.0 Off-Board Relays . Bosch Security Systems, Inc. | 5/05 | F01U003641B 49 Figure 21: D8129 Connections to the D7412GV2 Pin Battery ammin g E CONNECTIONS POWE R + DAT A BUS A DAT A BUS B COMMON ZONEX O UT 1 ZONEX IN 1 32 31 30 29 28 27 NOT USED 26 25 NOT USED EX POWER + 24 X COMMON 23 D520 0/[...]
-
Page 50
D9412GV2/D7412GV2 | Operation and Installation Guide | 10.0 Off-Board Relays 50 Bosch Security Systems, Inc. | 5/05 | F01U003641B To install OctoRelays in the enclosure with the control panel: 1. Align the module with one of the mounting locations in the enclosure (refer to Figure 2 on page 9). 2. Using the screws provided with the module, secure t[...]
-
Page 51
D9412GV2/D7412GV2 | Operation and Installation Guide | 10.0 Off-Board Relays . Bosch Security Systems, Inc. | 5/05 | F01U003641B 51 10.2.2 Installation Install the D811 in the enclosure with the control panel ( Figure 22 ) or in an adjacent enclosure no more than 1.5 m (5 ft.) from the control panel. Use 1.5 mm (16 AWG) to 0.8 mm (22 AWG) wire. To [...]
-
Page 52
D9412GV2/D7412GV2 | Operation and Installation Guide | 10.0 Off-Board Relays 52 Bosch Security Systems, Inc. | 5/05 | F01U003641B Figure 23: D811 Module Wiring to the D7412GV2 Pin Battery amming E CONNECTION S POWER + DAT A B US A DAT A B US B COMMON ZONEX O UT 1 ZONEX I N 1 32 31 30 29 28 27 NOT USED 26 25 NOT USED EX POWER + 24 X COMMON 23 D5200/[...]
-
Page 53
D9412GV2/D7412GV2 | Operation and Installation Guide | 11.0 Arming Devices . Bosch Security Systems, Inc. | 5/05 | F01U003641B 53 1 1 .0 Arming Devices 11.1 Description Keypads, maintained or momentary contact keyswitches, or a combination of the two are used to arm and disarm areas. The control panel can contain up to eight areas. Refer to 3.3.6 A[...]
-
Page 54
D9412GV2/D7412GV2 | Operation and Installation Guide | 11.0 Arming Devices 54 Bosch Security Systems, Inc. | 5/05 | F01U003641B You can connect devices to the data bus (Terminals 30 and 31) by parallel wire run from the control panel to each device, wire from device to device, or a combination of the two using a maximum of 4572 m (15000 ft) of 0.8 [...]
-
Page 55
D9412GV2/D7412GV2 | Operation and Installation Guide | 11.0 Arming Devices . Bosch Security Systems, Inc. | 5/05 | F01U003641B 55 11.3 D268/D269 Independent Zone Control, D279A Independent Zone Control Any on-board or OctoPOPIT point can be programmed so that the D268/D269 or D279A Independent Zone Control operates as independent point control (arm[...]
-
Page 56
D9412GV2/D7412GV2 | Operation and Installation Guide | 11.0 Arming Devices 56 Bosch Security Systems, Inc. | 5/05 | F01U003641B Momentary Contact If the point to which the keyswitch is connected is programmed for a momentary contact, shorting the arming circuit toggles the area’s arming state between armed and disarmed. All faulted points are for[...]
-
Page 57
D9412GV2/D7412GV2 | Operation and Installation Guide | 12.0 SDI Devices . Bosch Security Systems, Inc. | 5/05 | F01U003641B 57 1 2.0 S DI Devices 12.1 Description D9412GV2 or D7412GV2 Control Panels can support a number of accessory devices from the SDI Bus using Terminals 29 through 32. Some devices include the D1255 Command Center (keypad) (refer[...]
-
Page 58
D9412GV2/D7412GV2 | Operation and Installation Guide | 12.0 SDI Devices 58 Bosch Security Systems, Inc. | 5/05 | F01U003641B 12.4.1 Access Using Wiegand style cards or tokens, the D9210B can allow access for up to 996 cards or tokens on the D9412GV2, and up to 396 on the D7412GV2. User access authority can be configured to restrict access to certai[...]
-
Page 59
D9412GV2/D7412GV2 | Operation and Installation Guide | 12.0 SDI Devices . Bosch Security Systems, Inc. | 5/05 | F01U003641B 59 Figure 27: DX4020i DIP Switch Settings SER Rx Tx BUS Rx Tx LED ENABLE DB9 G ND ENABLE P1 P6 P2 P3 1 2 4 8 16 32 64 128 ON 123456 78 1 2 4 8 16 32 64 128 ON 123456 78 1 2 3 4 1 - Address DIP switches 2 - OFF position 3 - ON [...]
-
Page 60
D9412GV2/D7412GV2 | Operation and Installation Guide | 12.0 SDI Devices 60 Bosch Security Systems, Inc. | 5/05 | F01U003641B 12.6.3 Address Settings The DX4020 has specific DIP switch settings for SDI Address 88 when using the DX4020 for Remote Programming Software (RPS) or enhanced communications in a LAN or WAN environment. Refer to Figure 28 for[...]
-
Page 61
D9412GV2/D7412GV2 | Operation and Installation Guide | 13.0 Programmer and Accessory Connections . Bosch Security Systems, Inc. | 5/05 | F01U003641B 61 1 3.0 Programmer and Accessory Connect ions 13.1 Programmer Connector Refer to the D5200 Operation Manual (P/N: 74-06176-000) for complete information on using the D5200 programmer. To connect and d[...]
-
Page 62
D9412GV2/D7412GV2 | Operation and Installation Guide | 14.0 Faceplates 62 Bosch Security Systems, Inc. | 5/05 | F01U003641B 1 4.0 F aceplat es 14.1 D9412GV2 Faceplate Figure 32: D9412GV2 Faceplate EARTH GROUND COMMON BATTER Y NEGA TIVE ONL Y BATTER Y POSITIVE ONL Y RELA Y A RELA Y B RELA Y C + AUX POWER CLAS S 2 TR ANSFORM ER 16.5 VAC 40 VA 60 Hz M[...]
-
Page 63
D9412GV2/D7412GV2 | Operation and Installation Guide | 14.0 Faceplates . Bosch Security Systems, Inc. | 5/05 | F01U003641B 63 14.2 D7412GV2 Faceplate Figure 33: D7412GV2 TELCO RING TIP PHONE L INE SEIZED EARTH G ROUND COMMON RELAY A RELAY B RELAY C + AUX POWER CL ASS 2 TRAN SFO RMER 16.5 VAC 40 VA 60 Hz Model D1640 Interna lly Fused - Do Not short [...]
-
Page 64
D9412GV2/D7412GV2 | Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A 64 Bosch Security Systems, Inc. | 5/05 | F01U003641B Appendix A : Syst em W iring Diagrams , Issue A A.1 D9412GV2 Control Panel Figure 34: D9412GV2, Power Supply Side D1640 16.5 V , 4 0 VA 60 Hz Tra n sf or m er + AUX PWR ALARM TRI G COM SUPV IN ALAR [...]
-
Page 65
D9412GV2/D7412GV2 | Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A . Bosch Security Systems, Inc. | 5/05 | F01U003641B 65 Figure 35: D9412GV2, Input Points and Peripheral Devices P105BL D125B Sw . Aux Pwr Zone B Zone A Pnl C om mon Pnl C om mon Loop B- Loop A- Loop B+ Loop A+ Earth Ground 10 9 5 4 3 8 2 1 7 6 D129 Au[...]
-
Page 66
D9412GV2/D7412GV2 | Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A 66 Bosch Security Systems, Inc. | 5/05 | F01U003641B Figure 36: D9412GV2, SDI Devices PERIP HERAL DE VICE CONN ECTION S RED POW ER + YELL OW DATA BUS A GREE N D ATA BUS B BLACK C OMMO N ZONEX OUT 1 ZONEX IN 1 N.F.P.A. Style 3. 5 Signa lin g Line Circu[...]
-
Page 67
D9412GV2/D7412GV2 | Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A . Bosch Security Systems, Inc. | 5/05 | F01U003641B 67 A.2 D7412GV2 Control Panel Figure 37: D7412GV2, Power Supply Side + AUX PWR ALARM TRIG COM SUPV IN ALARM CKT D192C/G - D928 D8132 D113 BAT 2+ BA T 1+ BA T 2- BAT 1- SUPV CHGR+ CHGR- VA U X + EARTH[...]
-
Page 68
D9412GV2/D7412GV2 | Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A 68 Bosch Security Systems, Inc. | 5/05 | F01U003641B Figure 38: D7412GV2, Input Points and Peripheral Devices Sw. Aux P wr Zone B Zone A Pnl C ommon Pnl C ommon Loop B- Loop A- Loop B+ Loop A+ Earth Ground 10 9 5 4 3 8 2 1 7 6 Aux P ower Zone B Zone A[...]
-
Page 69
D9412GV2/D7412GV2 | Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A . Bosch Security Systems, Inc. | 5/05 | F01U003641B 69 Figure 39: D7412GV2, SDI Devices + - EARTH GR OUND COMMON BATT ERY NEG ATIVE ONLY Maximu m Chargi ng Cu rren t 1. 4 Amps . BAT TERY PO SITI VE ONLY RELAY A RELAY B RELAY C + AUX POWER CLASS 2 TR A[...]
-
Page 70
D9412GV2/D7412GV2 | Operation and Installation Guide | Appendix B: Point Address Charts 70 Bosch Security Systems, Inc. | 5/05 | F01U003641B Appendix B : P oint Address Chart s B.1 Zonex 1, Points 9 to 127 (D9412GV2); Zonex 1, Points 9 to 75 (D7412GV2) Place the labels on the base of the POPIT. Do not attach labels to the POPIT cover. A bullet ( ?[...]
-
Page 71
D9412GV2/D7412GV2 | Operation and Installation Guide | Appendix B: Point Address Charts . Bosch Security Systems, Inc. | 5/05 | F01U003641B 71 B.2 Zonex 2, Points 129 to 247 (D9412GV2 Only) Place the labels on the base of the POPIT. Do not attach labels to the POPIT cover. A number in the switch column indicates that the switch is set to ON. Table [...]
-
Page 72
D9412GV2/D7412GV2 | Operation and Installation Guide | Specifications 72 Bosch Security Systems, Inc. | 5/05 | F01U003641B Specific at ions Table 27: Specifications Primary: Terminals 1 and 2 16.5 VAC 40 VA class 2 plug-in transformer (D1640) Voltage Input (Power Supply) Secondary: Terminals 4 and 5 Sealed lead-acid rechargeable battery (12 VDC, 7 [...]
-
Page 73
D9412GV2/D7412GV2 | Operation and Installation Guide | Specifications . Bosch Security Systems, Inc. | 5/05 | F01U003641B 73 Notes[...]
-
Page 74
© 2005 Bosch Security Systems F01U003641B Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450-9199 Customer Service: (800) 289-0096 Technical Support: (888) 886-6189[...]