Bradford-White Corp IGE-199R Series manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 44 pages
- 1.35 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Water Heater
Bradford-White Corp 50T
2 pages 0.22 mb -
Water Heater
Bradford-White Corp SCF)-***
36 pages 1.4 mb -
Water Heater
Bradford-White Corp 238-47707-00E REV 7/12
60 pages 1.27 mb -
Water Heater
Bradford-White Corp TG237I-N(X)
92 pages 3.24 mb -
Water Heater
Bradford-White Corp U4-30T6FRN
2 pages 0.41 mb -
Water Heater
Bradford-White Corp CombiCor TTW
2 pages 0.28 mb -
Water Heater
Bradford-White Corp MI40T
28 pages 1.4 mb -
Water Heater
Bradford-White Corp Flammable Vapor Ignition Resistant Water Heater
28 pages 1.4 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Bradford-White Corp IGE-199R Series. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Bradford-White Corp IGE-199R Series ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Bradford-White Corp IGE-199R Series décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Bradford-White Corp IGE-199R Series devrait contenir:
- informations sur les caractéristiques techniques du dispositif Bradford-White Corp IGE-199R Series
- nom du fabricant et année de fabrication Bradford-White Corp IGE-199R Series
- instructions d'utilisation, de réglage et d’entretien de l'équipement Bradford-White Corp IGE-199R Series
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Bradford-White Corp IGE-199R Series ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Bradford-White Corp IGE-199R Series et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Bradford-White Corp en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Bradford-White Corp IGE-199R Series, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Bradford-White Corp IGE-199R Series, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Bradford-White Corp IGE-199R Series. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
BRADFORD WHITE EVERHOT ® TANKLESS GAS WATER HEATER FOR EXTERIOR INSTALLATION IGE-199R AND IGE-199C MODEL SERIES - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance - WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use a[...]
-
Page 2
SECTION I: IMPORTANT INFORMATION 2 This water heater has a limited warrant y . The warrant y for this water heater is valid onl y if the water heater has been installed, maintained and operated in acco rdance with these instruc tions. NOTICE TABLE OF CONTENTS I IMPORTANT INFORMATION 2 VII ELECTRICAL CONNE CTI ONS 21 II SPECIFICATIONS 5 VIII OPERATI[...]
-
Page 3
Improper installation, adjustments, alteratio n, service or maintenance can cause property damage, personal inju ry or loss of l ife. Failure to f ollow all inst ructions i n the proper orde r can cause pers onal injury or death. Read and understand all instruction s, including all those provided with the appliance before install ing, starting -up,[...]
-
Page 4
4 Flamma ble items, pressu rized contai ners or any other pot ential fire hazardous a rticles m ust never be placed on or adjacent to t he water heater. Open c ontainers of flamm able mate rial must not be stored or used in the same room with this water heater. DO NOT USE AN INSULATION BLAN KET WITH TH IS WATER HEATER. T his water heate r meets or [...]
-
Page 5
SECTION II: SPECIFICATIONS Max. Flow Rate @ Degree Temperature Rise Max. Input Rating Btu/hr. Min. Input Rating Btu/hr. Temp Rise 40 ° F 60 ° F 80 ° F 100 ° F 120 ° F Model No. 140 ° F 5 Flow Rate vs Temperatur e Rise Curve for EVERHOT ® IGE model series 0 1 2 3 4 5 6 7 8 9 0 25 50 75 100 125 150 Δ T – Temperature Ri se (° F ) Max. Flow [...]
-
Page 6
EVERHOT ® IGE Model Series Dimensions Dimensions (Inches) Height: 23 5/8” (60.0 cm) Width: 13 ¾” (34.9 cm) Depth: 8 7/8” (22.6 cm) Clearances from Combustible Materials: Top of water heater: 12” (30.5 cm), Front: 24” (61 cm), Sides: 6” (15.2 cm), Back: 0”, Ground: 12 (30.5 cm)” Maximum/Minimum Gas Input Rating, Btu/hr. 199,000 max[...]
-
Page 7
7 SECTION III: GENERAL INFORMATION FEATURES The Bradford White EVERHOT ® IGE series tankl ess water heater is a hi gh output, high efficien cy appliance, which heat s the water conti nuously as hot water is being drawn for u se. Unlike tank type storage water heaters, this water heat er doe s not store hot water. The bu rne r operates whenever the[...]
-
Page 8
SECTION IV: INSTALLATION INSTRUCTIONS 8 WARNING INSTALLATION OF THI S WATER HEATE R REQUIRES ABILITY EQUIVALENT TO THAT OF A LICENSED PLUMBE R. PLUMBING, AIR SUPPLY, VENTING, GAS SUPPLY AND ELECTRICAL WORK ARE REQUIRED. DO NOT ATTEMPT TO LIGHT ANY GAS APPLIANCE IF YOU ARE NOT CERTAIN OF THE FOLLOWING: • Liquefied petroleum gase s/propane gas and [...]
-
Page 9
9 WARNING WARNING • This water heater is suitable for potable w ater heating only. DO NOT use this water heater for space heating or combination space heating/domestic wate r heating. • This water heater is not suitable for use in pool or spa application s. • The water heater must be installed outdoo rs. Failure to properly install this water[...]
-
Page 10
Build Opening Clearances (Fig 1) Table 1 Minimum Installation Clearances Reference Description Minimum Distance in Inches (cm) A Vertically below a window, door which o pens, air inlet 12” (30.5 cm) B Vertically above a window, door whi ch opens, air inlet 12” (30.5 cm) C Below eaves, porches, or overhan gs 36” (91.4 cm) D Horizontally from a[...]
-
Page 11
SECTION V: WA TER CONNECTIONS WARNING Failure to install and maintain a new, listed pressu re relief valve will release the manufacture r from any claim, which might result from ex cessive temperatu re and pressures. Keep clear of the pressure relie f valve discharge line outlet. The discharge may be hot enough to cau se scald injury. The water is [...]
-
Page 12
12 2. In order to service the water heater in the event the heat exchanger needs to be flushe d fro m lime deposits, tee fittings with shut off valves and serv ice connections to hoses should be i nstalled. Also install a shut off valve to the hot water suppl y to isolate the service tee fittings. A plum bing installation kit, which incl udes these[...]
-
Page 13
Recommended Piping for a Basic Installation Fig. 2 13[...]
-
Page 14
Recommended Piping for Po wer Failure Freeze Protection As long as electrical power and gas are supplied to the EVERHOT ® water heater, free ze protection is provided to the heat exchanger and pipi ng inside the wa ter heater with ambient temperatures as col d as -30 ° F (-34 ° C), when protected from direct wi nd exposure. In the event of a pow[...]
-
Page 15
Recommended Piping for a Circulation Sy stem Fig. 4 15[...]
-
Page 16
Recommended Piping for Back-up Sto rage System For hotels, motels, and other high flo w applications (Fig. 5) Note: The Primary Circulator for the water heatin g loop must be sized for 21 GPM @ 35 Ft. Head. 16[...]
-
Page 17
PRESSURE RELIEF VALVE 17 Keep clear of the pressu re relief valve dischar ge line outlet. The discha rge may be hot enough to cause scald injury. The water is unde r pressure and m ay splash. For protection against excessive pressure, insta ll pressure protective equipment req uired by local codes, but not l ess than a pressure reli ef val ve certi[...]
-
Page 18
SECTION VI: GAS CONNECTIONS WARNING Connect this water heater only to the type of ga s as shown on the rating plate. Use clean black iron pipe or equivalent material approved by local codes and ordin ances. (Dirt and scale from the pip e can enter the gas valve and ca use it to malfunction). The inlet gas line must have at least a 3 inch (7.62 cm) [...]
-
Page 19
Check the type of gas and the gas inlet pressure before connecting the EVERHOT water heater to the gas supply. If the gas supply type does not m atch the type shown on the water heater rating plate, then DO NOT connect the water heater. Contact your Br adford White supplier for the corre ct water heater. GAS METER SIZE –NATURALGAS ONLY Be sure th[...]
-
Page 20
20 4. Turn power on (after completi ng electrical connections – re fer to Section VII, “Electrical Connections”) and fully open a hot water tap. 5. Measure the gas pressures to see that these are within the specified limits below: Supply Pressure: Nat. Gas: Min.: 6”, Max.: 10.5” w.c. L.P. Gas: Min.: 10”, Max.: 13.5” w.c. Manifold Pres[...]
-
Page 21
SECTION VII: ELECTRICAL CONNECTIONS WARNING Turn off or disconnect the electrical power supply to the water heater before servicing. Label all wires prior to disconnection when servicing controls. Wirin g errors can cause improper an d dangerous operation. Verify proper operation after servicing. All electrical wiring must be installed and grou nde[...]
-
Page 22
Wiring Diagram WARNING DO NOT adjust any dipswitch settings on PC board! 22[...]
-
Page 23
Wiring Diagram – Schematic 23[...]
-
Page 24
REMOTE TEMPERATURE CONT ROLS The supplied Remote Main Control allows the custom er to cont rol the hot water supply temperature and will display certain fault codes i n the event the water heater needs servicing. If used without the Remote Main Control connected, the residential models (IGE -199R-10N,10 X) have a fixed temperatu re setting of 120 ?[...]
-
Page 25
°F Set Tem perature Main Contro ller 239-44509-0 0 In Use Prio rity endless hot water system CAUTION: Hott er wat er increases the risk of scald injury. Before changing tem per at ure setting, s ee ins truc t ion manual. Main or Optional Remote Control for Residential Models (Fig. 6) Temperature Control(s) Installation: 1. Determine how many contr[...]
-
Page 26
WARNING Do not attempt to connect the remote controls with the p ower on to the water heater. There are 120 volt terminals and wiring next t o the remote control connecti ons inside t he unit. All servicing and wiring must be performed by a certified installer. 9. Thread the cable through the access hole at th e ba se of the water h eater and conne[...]
-
Page 27
°F Set Tem perature Main Contro ller 239-44509-00 In Use Prio rit y endless hot water system CAUTION: Hotter wa t er increas es the ris k of scald injury. Before changing temperature setting, see instruction manual. Control for Commercial Models (Fig. 7) Remote Temperature Control Installation: Follow the same control installation pro cedure as ou[...]
-
Page 28
SECTION VIII: OPERATING INSTRUCTIONS WARNING Water heaters are heat-p roducing appliances. To a v oid damage or injury there must be n o materials stored against the water heater or near the front vent outlet, an d proper care must be taken to avoi d unnecessary contact (especially by children) with the water heat er and front vent outlet. UNDER NO[...]
-
Page 29
LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFO RE OPERATIN G WARNING: If you do not follo w these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not ha ve a pilot. It is equipped with a direct ignition device, which automatically lights the burner. Do not try to[...]
-
Page 30
CAUTION In climates where below freezing tempe ratures may occur, the water heater must be d rained when power is off to the water heater to prev ent free ze damage to the heat exchanger. Drain solenoid s are recommended to prevent freeze damage during p o wer failures in cold climate region s. TURNING OFF THE WATER HEATER FOR AN EXTENDED PERIOD OF[...]
-
Page 31
2. To set the desired temperature on the rem ote control, all hot water faucets must be closed. If there are other Remote Controls installed, press the “Priority” but ton on the control you wan t to change the setting on and the yellow “Priority” indicat o r light will glow. 3. Press the “H” or “C” button until the required tem pera[...]
-
Page 32
Commercial Models (see Figure 11): 1. Commercial models are supplie d in the water h eater carton with a Remote Main Control, which will allow the outlet water temperat ure to be adjust ed from 98-185 ° F. When additional Remote Controls are installed, the temperature can onl y be adjusted on the remote control that ha s the Priority Indicator Lig[...]
-
Page 33
CAUTION Check local cod es for the maximum water tem perature setting allowed when used in nu rsing homes, schools, day care centers, and a ll other public use applications. NOTICE The default temperature setting di splayed for comm ercial control s that will appear when the water heater is first connected to the electrical supply or in the event o[...]
-
Page 34
APPROXIMATE TIME/TEMPERATURE RELATIONSHIPS IN SCALDS 120°F (49 ° C) More than 5 minutes 125°F (52 ° C) 1½ to 2 minutes 130°F (54 ° C) About 30 seconds 135°F (57 ° C) About 10 seconds 140°F (60 ° C) Less than 5 seconds 145°F (63 ° C) Less than 3 seconds About 1½ seconds 150°F (66 ° C) About 1 second 155°F (68 ° C) FIRST AID FOR SCA[...]
-
Page 35
SECTION IX: MAINTENANCE WARNING Always turn off the electrical power supply, the manual gas valve, and the manual water control valve whenever servicing this ap plian ce. KEEP THE APPLIANCE AREA CLEAR AN D FREE FROM COMBUSTIBLE MATERIALS, GASOLINE, AND OTHER FLAMMABLE VAPORS AND LIQUIDS! Do not block the air inlet openings o n the front panel or fl[...]
-
Page 36
WARNING Before manually operating the valve, make sure that a drain line has been attached to the valve to direct the discharge to an open drain. Failure to take this precaution could mean contact with extremely hot water passing out the valve during this che cking operation. FLUSHING PROCEDURE FOR LIME SCALE REMO VAL FROM HEAT EXCHANGER The amount[...]
-
Page 37
Lime Scale Flushing Diagram (Fig 13) COMMON TROUBLESHOO TING COMMENTS ON T HE OPERATION OF T HE EVERHOT ® TANKLESS WATER HEATER Comment: I don’t have any hot water when I open the tap! Make sure the gas and el ectricity is turned on to the water hea ter. The remote temperature di splay should have the green light lit when a hot water tap is open[...]
-
Page 38
SCHEMATIC DIAGRAM O F INTER NAL PARTS 38[...]
-
Page 39
SECTION X: PARTS LIST Cabinet Note: Can purchase add it ional co ntr o ls for remote locati ons. 39[...]
-
Page 40
Internal Components 40[...]
-
Page 41
Internal Components 41[...]
-
Page 42
Electrical Components 42[...]
-
Page 43
43 PARTS LIST Number Description Quantity 001 Front Panel Assembly 1 002 Casing Assembly 1 003 Wall Installation Bracket 1 004 Connection Reinforcement Panel 1 005 Heat Protection Plate 1 006 Rubber Bushing 1 007 Front Panel Gasket 1 008 Front Panel Gasket - Side 1 009 Front Air Inlet Grill 1 011 Rubber Bushing 1 102 Gas Connection (¾” NPT) 1 10[...]
-
Page 44
44 PARTS LIST Number Description Quantity 716 Anti-Frost Heater Clip 2 717 Anti-Frost Heater Clip A 1 718 Anti-Frost Heater Clip 1 720 Power Supply Harness 1 721 Fuse Harness 1 722 100v Harness 1 723 Solenoid Valve Harness 1 725 Thermal Fuse Harness 1 726 Mold-type Limit S witch 1 730 PCB Assembly 1 731 Surge Protector 1 732 Frost Sensing Switch 1 [...]