Bradford-White Corp MI30S manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 28 pages
- 1.4 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Water Heater
Bradford-White Corp D65T625
52 pages 3.21 mb -
Water Heater
Bradford-White Corp EF60T199(E)*(N
92 pages 7.65 mb -
Water Heater
Bradford-White Corp MI303T
28 pages 1.4 mb -
Water Heater
Bradford-White Corp ULTRA HIGH EFFICIENCY COMMERCIAL GAS WATER HEATER
76 pages 1.21 mb -
Water Heater
Bradford-White Corp UDH65T45FR*N
28 pages 2.2 mb -
Water Heater
Bradford-White Corp GX155S*BN
16 pages 0.73 mb -
Water Heater
Bradford-White Corp 50T
2 pages 0.22 mb -
Water Heater
Bradford-White Corp MITW -10
27 pages 1.02 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Bradford-White Corp MI30S. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Bradford-White Corp MI30S ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Bradford-White Corp MI30S décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Bradford-White Corp MI30S devrait contenir:
- informations sur les caractéristiques techniques du dispositif Bradford-White Corp MI30S
- nom du fabricant et année de fabrication Bradford-White Corp MI30S
- instructions d'utilisation, de réglage et d’entretien de l'équipement Bradford-White Corp MI30S
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Bradford-White Corp MI30S ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Bradford-White Corp MI30S et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Bradford-White Corp en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Bradford-White Corp MI30S, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Bradford-White Corp MI30S, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Bradford-White Corp MI30S. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
The Bradford White Flammable V apor Ignition Resistant W ater Heater SER VICE MANU AL T roub leshooting Guide and Instr uction f or Ser vice (T o be perf or med ONL Y b y qualified ser vice providers) MI30T*F(BN,CX) MI30S*F(BN, CX) MI303T*F(BN,CX) MI40T*F(BN,CX) MI403S*F(BN,CX) MI404T*F(BN,CX) MI503*F(BN,CX) MI50L*F(BN,CX) MI504S*F(BN,CX) MI60T*F(B[...]
-
Page 2
3 Table of Contents Page Service Procedure Introducti o n 3 --- T rouble shooting Ch art 4 - - - In ner Door Gasket Removal, Inspection, Replacement and Install ation T hermocouple Testing and Replaceme nt P ilot Assembly Inspection Cleaning and Replacement 10 RG-III Piezo Igniter and Electrode Testing 11 RG-IV Combination Thermostat/Gas Valve Test[...]
-
Page 3
4 INTRODUCTION The Bradf ord White DEFENDER Safety System ® The Bradford White DEFENDER Safety System ® w as designed to resist the ignition of flammable v apors that can occur outside of the water heater . Use and installation are nearly identical to pre vious versions of atmosphericall y f ired and vented w ater heaters. A number of exclusi ve [...]
-
Page 4
5 SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Pilot Will Not Light 1. No incoming gas or too low gas pressure. 2. Gas control knob set to wrong position. 3. Pilot light button not being fully depressed when attempting to light pilot. 4. Pilot orifice or pilot tube is obstructed or kinked. 5 . Pilot electrode not sparking to pilot. 6 . Piezo igniter no[...]
-
Page 5
6 Inner Door R emov al Procedure Step 1. Rotate knob of the c ombination thermostat/gas valve to the “O F F” p osition. Step 2. Remove outer jacket b urner a c cess door Step 3. Inner Door Removal. a) Disco nne ct resettable thermal switch wire l eads (l eading from comb i nat ion t hermostat/g as valve). b) Remove (2) 1/4" hex drive screw[...]
-
Page 6
7 Installat ion of Inner Door With Gasket. WARNING Stripped fastener connections may allow for seal breach of inner door. A seal breach may result in a fire or explosion causing property damage, personal injury or death. Do not over tighten screws in steps 8, 10 and 11. If a fastener connection is stripped, contact the manufacturer listed on the wa[...]
-
Page 7
8 S tep 10. Firmly place r ight s ide inner door flange a gainst the left side inner door fl ange and se cure with two ¼” drive s crews from step 3 c. DO NOT OVER TIGHTEN SCREWS . S tep 11. A lign r ight side inner do or to comb ustion cham ber and verify the fastener holes of the combustion cha mber are a lig ned with the r ight side inner doo [...]
-
Page 8
9 Step 1. C losed circuit t esting is the pref erred method for t esting t hermocoup le. Fol low in g the lightin g instruc tion label on the heate r, p roceed to light th e pi lot and a l low to oper ate f or three minue ts. If the pilot will not stay lit, hold the pilot button ( located on t he c ombi nation therm ost at/gas valve) down durin g t[...]
-
Page 9
10 THERM OCOUPLE REPLACEMENT Step 1. Turn off gas supply to water heate r. Rot ate knob of c ombination therm ostat/gas valve to “O FF” position. Step 2. R emo ve outer jacket door. Step 3. R emo ve right side of inner door per SERVICE PROCEDURE RG-I, steps 3a through 3c. Step 4 Disconnect thermocouple f rom co mbina tion th ermostat/gas valve [...]
-
Page 10
11 PILOT/ELECTRODE ASSEMBLY I NSPECTION, CLEA NING AND R EPLACEMENT S tep 1. Turn off gas sup ply to wa ter h eat er. Rotate knob of combination thermostat/gas valve to “O F F” position. Step 2. Remove outer jacket door. S tep 3. Remove r ight side of inner door per SERVICE PROCEDURE RG-I , steps 3a thro ugh 3c. Step 4 Disco nne ct thermocouple[...]
-
Page 11
12 PIEZO IGNITER, ELECT RODE TESTING AND REP LACEMENT Wi th the pilot not in opera tion ( no pilot fl ame) you can check t he Piezo and e lect rode ci r cuit by v iew ing pilot thru the sight glass locat ed on the i nner do or and ob servi ng the spark a ction. S tep 1. R emove outer jack et door. Step 2. R epeatedly depr ess t he P iezo igniter wh[...]
-
Page 12
13 The combination thermostat/gas valve is a n on repairable devi ce. If tr ouble sho otin g has de term ined a probl em with the combina tion t her mostat/gas valve, it must be r eplaced. If the burner and/or pilot do not function, service checks for gas pressu re, thermoco uple output, magnet assembly and ECO are to be performed. If these check O[...]
-
Page 13
14 Se e SERVICE P ROCED URE RG-II THE RMOCOUPLE TESTING MAGNET ASSEMBLY TESTING (Whi te Rodgers Control) Step 1. Following the light ing i nstru ction l abel on t he h eat er, p roceed to light the pilot and allow to operate for three minuets. If the pilot will not stay lit, hol d the pilot button (lo cat ed on the c ombination thermosta t/gas v al[...]
-
Page 14
15 COMBI NATION THE RMOSTAT/GAS VALVE REPLACEMENT Step 1. Rotate knob of the comb i nati on t hermostat/ gas valve to the “OFF” p osition. Step 2. Turn off gas supply to water heater. Step 3. Disconne ct gas s upply line from combina tion t hermostat/ gas valve. Step 4. Turn off water supply and drain water heater completely. Step 5. Remove out[...]
-
Page 15
16 Step 7. Removal of combination thermostat/gas valve. a) Disconnect main burner feed line (¾” wrench), pilot tube (7/16" wrench) and thermocouple (3/8" wrench) from combination thermostat/gas valve & remove burner from combustion chamber. NOTE: Feed line nut for natural gas control uses right hand threads, LP control uses left ha[...]
-
Page 16
17 Step 9. Reinstallation of inner door assembly. (cont.) b) Clean an y gasket residue or other debris from comb ustion cha mber surface before installing the inner door/gasket assembly. c) Position thermocouple, pilot tube and Pie zo wi re a gain st left side inn er door flange g asket. DO NOT ROUTE THROUGH RADIUSED CHANNEL WITH FEED LINE. Be s ur[...]
-
Page 17
18 S tep 1. With ma in burn er in o perati on, rem ove right side inner door p er s erv ice p rocedu re I, s teps 3b & 3c. Be sure to maintain wire connection to reset table th er mal s witch for this a djustm ent proce dure. Step 2. To ad just for proper burning, loosen the air sh utte r n ut, r ota te the s hutter to clos e the opening in the[...]
-
Page 18
19 Step 3. Fully inspect inner gasket pe r S ERVICE PROCED URE R G-I, s tep 4. Replace g asket if r equi red f ollowing SERVICE PROCEDURE I, steps 5 & 6. Step 4. Be ce rtain t hat thermo couple, pilot tube and piezo wire are routed by inner door flange as shown and Reinstall inner door per SERVICE P ROCEDURE R G-I, s tep 1 0 and 11. Step 5. Obs[...]
-
Page 19
20 S tep 5. D isconn ect ( unscr ew) M ain burner (stamped steel “B” burner) from m ain burner orifi ce or on cast ir on burners (“C” burner), loosen air shutter & disconnect ( unscrew) feedline from b urner. Step 6. Remove main b urner orifi ce f rom feed line (½” wrench on steel b urner, 3/8 " wrench on cast iron). Inspe ct an[...]
-
Page 20
21 Step 1. Remove outer jacket door. Step 2. Disconnect wire leads fro m r esetta ble thermal s witch. Step 3. Using a m ultimeter capa ble of meas uring continuity (Ohms), pl ace one probe of m eter on one of the brass con nec tion tabs of the resettab le thermal switch, a nd the re maini ng p robe on the other connection tab. Step 4. If continuit[...]
-
Page 21
22 RESETTABLE THERMAL SWITCH REPLACEMENT S tep 1. Rotate k nob of combination thermostat gas valve to the off position. S tep 2. Remove outer jacket door. Step 3. D isconne ct wire l eads from resetta ble thermal switch. S tep 4. Remove resettable th erm al swi tch from inner door (Phillips screw driver) Step 5. Pla ce new resettable thermal switc [...]
-
Page 22
23 Step 1. R otate knob of c ombination thermostat gas valve to the off position. Step 2. R emove outer jacket door. S tep 3. Remove inner door per S ERVI CE PROCEDURE RG -I, step 3a through 3e. Step 4. Disconnect main b urn er feed line (¾ wrench), pilot tube (7/16 wre nch) a nd t hermocoup le (3/8) wrench from com bination thermostat gas valve a[...]
-
Page 23
24 S tep 1. Rotate knob o f combina tion ther mostat/ gas valve to “OFF” position. S tep 2. Turn off cold water supply to heater. Connect ho se to dra in spigot of w ater h eater a nd route to an open drain. Open a nearby hot water faucet to vent he ater f or drainin g. Open drain sp igot of hot water h eat er and a l low heater to drain to a p[...]
-
Page 24
25 S tep 1. Turn off wa ter sup ply to water h eat er. Ro ta te knob of c ombinat ion t hermostat/ga s valve to “OFF” position. S tep 2. Turn off cold water supply to heater. Connect ho se to dra in spigot of w ater h eater a nd route to an open drain. Open a nearby hot water faucet to vent he ater f or drainin g. Open drain sp igot of hot wate[...]
-
Page 25
26 1 Draf t Hood 2 Hot Water Outlet/Anode 3 Cold Water Inlet Tube 4 Flue Baffle 5 T&P Relief Valve 6 Thermostat 7 Piezo Igniter 8 Brass Drain Valve 9 Screw-#8-18 x 3/4 Hex Washer Head 10 Screw-#10-12 x 3/4 Hex Washer Head 11 Left S ide Inner Door with Gasket 12 Complete Right Si de Inner Door 14 Resetta ble Thermal Switch 15 Screw #6-20 x 3/8 P[...]
-
Page 26
NOTES[...]
-
Page 27
NOTES[...]
-
Page 28
Application & Sizing/ 800-523-2931 Fax/ 215-641-1612 Email parts@bradfordwhite.com techserv@bradfordwhite.com www .bradfordwhite.com www .bradfordwhitecanada.com[...]