Briggs & Stratton 204330GS manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 52 pages
- 3.37 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Portable Generator
Briggs & Stratton 40229
56 pages 3.81 mb -
Portable Generator
Briggs & Stratton 040210-1
7 pages 0.76 mb -
Portable Generator
Briggs & Stratton 030320
44 pages 2.85 mb -
Portable Generator
Briggs & Stratton PRO4000
56 pages 1.98 mb -
Portable Generator
Briggs & Stratton 23A
8 pages 3.11 mb -
Portable Generator
Briggs & Stratton PowerBoss 30220
32 pages 1.83 mb -
Portable Generator
Briggs & Stratton 30372
5 pages 0.46 mb -
Portable Generator
Briggs & Stratton 030334
3 pages 0.34 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Briggs & Stratton 204330GS. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Briggs & Stratton 204330GS ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Briggs & Stratton 204330GS décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Briggs & Stratton 204330GS devrait contenir:
- informations sur les caractéristiques techniques du dispositif Briggs & Stratton 204330GS
- nom du fabricant et année de fabrication Briggs & Stratton 204330GS
- instructions d'utilisation, de réglage et d’entretien de l'équipement Briggs & Stratton 204330GS
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Briggs & Stratton 204330GS ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Briggs & Stratton 204330GS et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Briggs & Stratton en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Briggs & Stratton 204330GS, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Briggs & Stratton 204330GS, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Briggs & Stratton 204330GS. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Printed in U.S.A. Manual No. 204330GS Revision A (08/16/2007) 6200 W att Portable Generator Operator’ s Manual BRIGGS & STRA TTON POWER PRODUCTS GROUP , LLC JEFFERSON, WISCONSIN, U.S.A.[...]
-
Page 2
2 BRIGGSandSTRATTON.COM Briggs & Stratton Power Products Group, LLC 900 North Parkway Jefferson, WI 53549 Copyright © 2007 Briggs & Stratton Power Products Group, LLC. All rights reserved. No part of this material may be reproduced or transmitted in any form by any means without the express written permission of Briggs & Stratton Power[...]
-
Page 3
T able of Contents Operator Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Equipment Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Safety Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Assembly . . . . . . . . . .[...]
-
Page 4
Operator Safety Equipment Description Read this manual carefully and become familiar with your generator. Know its applications, its limitations and any hazards involved. The generator is an engine–driven, revolving field, alternating current (AC) generator. It was designed to supply electrical power for operating compatible electrical lighting, [...]
-
Page 5
5 W ARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. W ARNING Generator produces hazardous voltage. Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.[...]
-
Page 6
6 BRIGGSandSTRATTON.COM W ARNING Contact with muffler area can result in serious burns. Exhaust heat / gases can ignite combustibles, structures or damage fuel tank causing a fire. • DO NOT touch hot parts and AVOID hot exhaust gases. • Allow equipment to cool before touching. • Keep at least 5 feet (1.5 m) of clearance on all sides of genera[...]
-
Page 7
7 Assembly Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended fuel and oil. If you have any problems with the assembly of your generator, please call the generator helpline at (800) 743-4115 . If calling for assistance, please have the model, revision, and serial number from the data [...]
-
Page 8
Verify Engine Oil Level The generator engine is shipped from the factory filled with oil (API SJ or higher 10W-30). This allows for generator operation in the widest range of temperature and climate conditions. Before starting the engine, check oil level and ensure that engine is serviced as described in Maintenance . NOTE: See Oil in the Maintenan[...]
-
Page 9
9 5. Verify that connections to battery and generator are tight and secure. NOTE: Charge prior to use following the instructions in the section Battery Float Charger . System Ground The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles. The system ground is connected to t[...]
-
Page 10
10 BRIGGSandSTRATTON.COM Features and Controls Read this Operator’s Manual and safety rules before operating your generator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. A - Choke Lever — Used when starting a cold engine. B -[...]
-
Page 11
11 Cord Sets and Receptacles Use only high quality, well-insulated, grounded extension cords with the generator’s 120 Volt duplex receptacle. Inspect extension cords before each use. Check the ratings of all extension cords before you use them. Extension cord sets used should be rated for 125 Volt AC loads at 20 Amps or greater for most electrica[...]
-
Page 12
Battery Float Charger Use battery float charger jack to keep the starting battery charged and ready for use. Battery charging should be done in a dry location, such as inside a garage. 1. Plug charger into unit’s “Battery Float Charger” jack, which is located next to the start switch. Plug battery charger into a 120 Volt AC wall receptacle. 2[...]
-
Page 13
13 Operation Starting the Engine IMPORTANT: Always unplug the battery float charger before starting the generator. Disconnect all electrical loads from the generator. Use the following start instructions: 1. Make sure unit is on a level surface. IMPORTANT: Failure to start and operate the unit on a level surface will cause the unit not to start or [...]
-
Page 14
Connecting Electrical Loads 1. Let engine stabilize and warm up for a few minutes after starting. 2. Plug in and turn on the desired 120 and/or 240 Volt AC, single phase, 60 Hz electrical loads. NOTE: • DO NOT connect 240 Volt loads to the 120 Volt duplex receptacles. • DO NOT connect 3-phase loads to the generator. • DO NOT connect 50 Hz loa[...]
-
Page 15
15 Don’t Overload Generator Capacity You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps: 1. Select the items you will power at the same time. 2. Total the rated (running) watts of these items. This is the amount of power your gener[...]
-
Page 16
16 BRIGGSandSTRATTON.COM Maintenance Maintenance Schedule Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions noted below. 1 Change oil after the first (5) operating hours and every 50 hours or every year, whichever occurs first, thereafter. Change oil sooner when o[...]
-
Page 17
17 • Use a soft bristle brush to loosen caked on dirt or oil. • Use a vacuum cleaner to pick up loose dirt and debris. Battery Maintenance Other than float charging, described elsewhere, no maintenance is required for the starting battery. Keep the battery and terminals clean and dry. IMPORTANT: Battery charging should be performed in a dry loc[...]
-
Page 18
Checking Oil Level Oil level should be checked prior to each use or at least every 5 hours of operation. Keep oil level maintained. 1. Make sure generator is on a level surface. 2. Clean area around oil fill and remove oil fill cap. 3. Verify oil is at the point of overflowing at oil fill opening. 4. Replace and tighten oil fill cap. Adding Engine [...]
-
Page 19
19 Service Spark Arrester The engine exhaust muffler has a spark arrester screen. Inspect and clean the screen every 100 hours of operation or once each year, whichever comes first. If you use your generator on any forest-covered, brush- covered, or grass-covered unimproved land, it must have a spark arrester. The spark arrester must be maintained [...]
-
Page 20
20 BRIGGSandSTRATTON.COM Storage The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage. Generator Storage • Clean the generator as outlined in Cleaning . • Check that c[...]
-
Page 21
21 T roubleshooting Problem Cause Correction Engine is running, but no AC output is available. 1. One of the circuit breakers is open. 2. Fault in generator. 3. Poor connection or defective cord set. 4. Connected device is bad. 1. Reset circuit breaker. 2. Contact authorized service facility. 3. Check and repair. 4. Connect another device that is i[...]
-
Page 22
22 BRIGGSandSTRATTON.COM W arranties Emissions Control System Warranty Briggs & Stratton Corporation (B&S), the California Air Resources Board (CARB) and the United States Environmental Protection Agency (U.S. EPA) Emissions Control System Warranty Statement (Owner’s Defect Warranty Rights and Obligations) California, United States and Ca[...]
-
Page 23
23 2. Length of Coverage B&S warrants to the initial owner and each subsequent purchaser that the Warranted Parts shall be free from defects in materials and workmanship which caused the failure of the Warranted Parts for a period of two years from the date the engine is delivered to a retail purchaser. 3. No Charge Repair or replacement of any[...]
-
Page 24
24 BRIGGSandSTRATTON.COM BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC PORTABLE GENERATOR OWNER WARRANTY POLICY LIMITED WARRANTY Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the portable generator that is defective in material or workmanship or both. Transportation charges on product submi[...]
-
Page 25
25[...]
-
Page 26
26 BRIGGSandSTRATTON.COM Portable Generator Power Ratings: The gross power rating for individual gas engine models is labeled in accordance with SAE (Society of Automotive Engineers) code J1940 (Small Engine Power & Torque Rating Procedure), and rating performance has been obtained and corrected in accordance with SAE J1995 (Revision 2002-05). [...]
-
Page 27
Génératrice portative 6200 watts Manuel d’utilisation BRIGGS & STRA TTON POWER PRODUCTS GROUP , LLC JEFFERSON, WISCONSIN, U.S.A.[...]
-
Page 28
2 BRIGGSandSTRATTON.COM Merci d’avoir acheté cette génératrice de qualité Briggs & Stratton. Nous sommes heureux que vous fassiez confiance à la marque Briggs & Stratton. Si vous respectez les instructions d’utilisation et d’entretien de ce manuel, vous pourrez vous fiez à votre génératrice Briggs & Stratton durant de nomb[...]
-
Page 29
3 Français T able des Matières Sécurité de l’opérateur . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Description de l équipement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Règles de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Assemblage . . [...]
-
Page 30
4 BRIGGSandSTRATTON.COM Sécurité de l’opérateur Description de l équipement Lisez avec soin ce manuel et familiarisez-vous avec votre générateur. Connaissez ses applications, ses limitations et les dangers qu'il implique. Ce générateur est un générateur entraîné par un moteur à champ magnétique rotatif produisant du courant alt[...]
-
Page 31
5 Français A VER TISSEMENT L’échappement du moteur de ce produit contient des produits chimiques que l’État de Californie considère comme causant le cancer, des déformations à la naissance ou d’autres dangers concernant la reproduction. A VER TISSEMENT • Cette génératrice ne satisfait pas aux normes U. S. Coast Guard Regulation 33CF[...]
-
Page 32
6 BRIGGSandSTRATTON.COM A VER TISSEMENT Le génératrice produit une tension élevée. NE PAS isoler le génératrice de l'installation électrique risque de provoquer des blessures ou même d'être fatal pour les ouvriers électriciens et de causer des dommages au génératrice dus à un "backfeed" d'énergie électrique. [...]
-
Page 33
7 Français Assemblage Votre génératrice doit être assemblée et vous pourrez l’utiliser après l’avoir correctement remplie d’huile et d’essence recommandées. Si vous avez n'importe quels problèmes avec l'assemblée de votre générateur, s'il vous plaît appeler le helpline de générateur à (800) 743-4115 . Si vous t[...]
-
Page 34
8 BRIGGSandSTRATTON.COM Vérification du niveau d’huile du moteur Le moteur de la génératrice a été rempli d’huile (API SJ ou plus 10W-30) avant son expédition de l’usine. Cela permet à la génératrice de fonctionner dans une plage élargie de températures et de conditions climatiques. Avant de démarrer le moteur, vérifiez le niveau[...]
-
Page 35
9 Français 3. Branchez le rondelle frein, la rondelle plate et la câble de retour (noir) de la batterie ( D ) par-dessus la vis. 4. Rattachez la vis au terminal négative de pile et serrez. 5. Vérifiez que les branchements de la batterie et du générateur sont appropriés et sécuritaires. REMARQUE : Veuillez la charger avant l’utilisation en[...]
-
Page 36
10 BRIGGSandSTRATTON.COM A - Levier d’étrangleur — Utilisé lors du démarrage à froid d’un moteur. B - Filtre à air — Protège le moteur en filtrant la poussière et les débris dans la prise d’air. C - Interrupteur de démarrage — Pousser pour démarrer le moteur. D - Chargeur à tampon de batterie — Utilisez la prise du chargeur[...]
-
Page 37
11 Français 11 Cordons et prises N’utilisez que des rallonges de haute qualité mises à la terre et bien isolées dans la prise double de 120 volts de la génératrice. Inspectez les rallonges avant chaque utilisation. Vérifiez le calibre de chacune des rallonges avant de les utiliser. Les rallonges utilisées doivent pouvoir supporter des cha[...]
-
Page 38
12 BRIGGSandSTRATTON.COM Chargeur de batterie Utilisez une prise de chargeur de flotteur pour que la batterie de démarrage reste chargée et prête à l'utilisation. Le chargement de la batterie doit être effectué dans un endroit sec, à l'intérieur d'un garage par exemple. 1. Branchez le chargeur à la prise “Battery Float Cha[...]
-
Page 39
13 Français Opération Démarrage du moteur IMPORTANT: Débranchez toujours le chargeur de flotteur de la batterie avant de démarrer le générateur. Déconnectez toutes les charges électriques du générateur. Suivez ces étapes d'instructions de démarrage dans l'ordre numérique: 1. Assurez-vous que la génératrice se trouve sur un[...]
-
Page 40
14 BRIGGSandSTRATTON.COM REMARQUE: Si le moteur démarre après 3 essais, mais qu’il ne fonctionne pas, ou qu'il s'arrête, assurez-vous que la génératrice se trouve sur une surface de niveau et vérifiez si le carter du moteur contient suffisamment d'huile. Il se peut que cette génératrice soit munie d’un système de protect[...]
-
Page 41
15 Français Ne pas surchargez générateur Capacité Vous devez vous assurer que votre générateur puisse fournir suffisamment de puissance nominale (appareil en marche) et de surtension (au démarrage) pour les appareils que vous voulez alimenter en même temps. Suivez ces étapes simples: 1. Sélectionnez les appareils que vous voulez alimenter[...]
-
Page 42
16 BRIGGSandSTRATTON.COM Recommandations générales Un entretien régulier améliorera la performance et prolongera la durée de vie de la génératrice. Consultez un détaillant autorisé Briggs & Stratton pour l’entretien. La garantie de la génératrice ne couvre pas les éléments soumis à l’abus ou à la négligence de l’opérateur[...]
-
Page 43
17 Français Nettoyage À tous les jours ou avant de l’utiliser, regardez autour ou sous la génératrice s’il y a des signes de fuites d’huile ou d’essence. Nettoyez les débris accumulés à l’intérieur et à l’extérieur de la génératrice. Gardez toujours la tringlerie, le ressort et les autres commandes du moteur propres. Inspect[...]
-
Page 44
18 BRIGGSandSTRATTON.COM Entretien du moteur Huile Recommandations relatives à l’huile Nous recommandons l’utilisation des huiles certifiées par garantie Briggs & Stratton pour obtenir une meilleure performance. Les autres huiles détergentes de haute qualité sont acceptables si elles ont les cotes pour service SF, SG, SH, SJ ou plus. N?[...]
-
Page 45
19 Français 19 Changez l’huile lorsque le moteur est encore chaud, de la façon suivante : 1. Assurez-vous que l’unité se trouve sur une surface de niveau. 2. Débranchez le câble de bougie de la bougie et placez-le à un endroit où il ne peut entrer en contact avec la bougie. 3. Nettoyez la surface autour du bouchon de vidange d’huile ( [...]
-
Page 46
20 BRIGGSandSTRATTON.COM Entretien du pare-étincelles Le silencieux d’échappement du moteur est muni d’un écran pare-étincelles. Examinez et nettoyez l’écran à toutes les 100 heures d’utilisation ou une fois par année, le premier des deux prévalant. Si vous utilisez votre génératrice sur un terrain boisé, couvert de broussailles [...]
-
Page 47
21 Français Entreposage Il est préférable de démarrer la génératrice au moins une fois tous les sept jours et de la laisser fonctionner durant au moins 30 minutes. Si cela n’est pas possible et que vous devez entreposer la génératrice durant plus de 30 jours, suivez les directives ci-après pour préparer l’unité en vue de l’entrepos[...]
-
Page 48
22 BRIGGSandSTRATTON.COM Problème Cause Solution Le moteur fonctionne, mais il n’y a aucune sortie de C.A. 1. Un des disjoncteurs est ouvert. 2. Défaillance dans la génératrice. 3. Mauvais branchement ou cordon défectueux. 4. L’appareil branché est défectueux. 1. Réarmez le disjoncteur. 2. Contactez un centre de service autorisé. 3. V?[...]
-
Page 49
23 Français Garanties Garantie du dispositif antipollution Briggs & Stratton Corporation (B&S), le California Air Resources Board (CARB) et le United States Environmental Protection Agency (U.S. EPA) Énoncé de garantie du dispositif antipollution (Droits et obligations du propriétaire relatifs à la garantie contre les défauts) Énonc?[...]
-
Page 50
24 BRIGGSandSTRATTON.COM e. Éléments divers utilisés dans les systèmes précédemment mentionnés • Soupapes et interrupteurs de dépression, de température, de position, à délai critique • Connecteurs et dispositifs 2. Durée de la couverture B&S garantit au propriétaire initial et à tous les acheteurs ultérieurs que les pièces [...]
-
Page 51
25 Français 25 Nous acceptons de faire effectuer les réparations couvertes par la garantie et tenons à nous excuser pour tout inconvénient subi. Tout agent d'un service après-vente agréé peut exécuter les réparations couvertes par la garantie. La plupart des réparations couvertes par la garantie sont traitées automatiquement; cepend[...]
-
Page 52
26 BRIGGSandSTRATTON.COM (800) 743-4115 Puissance nominale: La puissance nominale brute des modèles avec moteur à essence est indiquée sur une étiquette, conformément au code J1940 (Small Engine Power & Torque Rating Procedure) de la SAE (Society of Automotive Engineers), et la performance nominale a été obtenue et corrigée conformémen[...]