Cabletron Systems STH-22 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 35 pages
- 0.32 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Switch
Cabletron Systems SEHI-22FL
85 pages 1.78 mb -
Switch
Cabletron Systems 9F120-08
36 pages 0.25 mb -
Switch
Cabletron Systems 7C03 MMAC
16 pages 0.28 mb -
Switch
Cabletron Systems 9T425-16
40 pages 0.44 mb -
Switch
Cabletron Systems 9A100
114 pages 0.7 mb -
Switch
Cabletron Systems 2E42-27R
164 pages 1.21 mb -
Switch
Cabletron Systems SEHI-34
93 pages 0.56 mb -
Switch
Cabletron Systems 9E429-12
18 pages 0.23 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Cabletron Systems STH-22. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Cabletron Systems STH-22 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Cabletron Systems STH-22 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Cabletron Systems STH-22 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Cabletron Systems STH-22
- nom du fabricant et année de fabrication Cabletron Systems STH-22
- instructions d'utilisation, de réglage et d’entretien de l'équipement Cabletron Systems STH-22
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Cabletron Systems STH-22 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Cabletron Systems STH-22 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Cabletron Systems en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Cabletron Systems STH-22, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Cabletron Systems STH-22, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Cabletron Systems STH-22. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
CABLETRON SYSTEMS, P. O. Box 5005, Rochester, NH 03866-5005 STH-22/-24/-42/-44 STACKABLE TOKEN RING HUB USER’S GUIDE[...]
-
Page 2
NOTICE iii NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to chan[...]
-
Page 3
NOTICE iv FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to com[...]
-
Page 4
NOTICE v CABLETRON SYSTEMS, INC. PROGRAM LICENSE AGREEMENT IMPORTANT: Before utilizing this product, carefully read this License Agreement. This document is an agreement between you, the end user, and Cabletron Systems, Inc. (“Cabletron”) that sets forth your rights and obligations with respect to the Cabletron software program (the “Program?[...]
-
Page 5
NOTICE vi EXCLUSION OF WARRANTY AND DISCLAIMER OF LIABILITY 1. EXCLUSION OF WARRANTY. Except as may be specifically provided by Cabletron in writing, Cabletron makes no warranty, expressed or implied, concerning the Program (including Its documentation and media). CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO YOU BY CABLETRON IN [...]
-
Page 6
NOTICE vii UNITED STATES GOVERNMENT RESTRICTED RIGHTS The enclosed product (a) was developed solely at private expense; (b) contains “restricted computer software” submitted with restricted rights in accordance with Section 52227-19 (a) through (d) of the Commercial Computer Software - Restricted Rights Clause and its successors, and (c) in all[...]
-
Page 7
CONTENTS ix CONTENTS CHAPTER 1 INTRODUCTION 1.1 Using This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.2 STH Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.2.1 LANVIEW LEDs . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 1.2.2 TCU Ports . . . . . . . . . . . . . . . . . . . . . . [...]
-
Page 8
CONTENTS x CHAPTER 3 INSTALLATION 3.1 Unpacking the STH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3.2 Installing the STH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3.2.1 Rack Mount or Wall Mount Hardware. . . . . . . 3-1 3.2.2 Adding the STH to a Stack . . . . . . . . . . . . . . . . . 3-2 3.2.3 Attaching th[...]
-
Page 9
Page 1-1 CHAPTER 1 INTR ODUCTION W elcome to the Cabletron Systems STH-22/-24/-42/-44 Stackable Token Ring Hub User’s Guide . The STH (Stackable Token Ring Hub) is a non- intelligent hub designed to provide expanded connectivity for Cabletr on Systems’ STHi intelligent hubs and Cabletron Systems Micr oMMAC intelligent hubs. This manual provides[...]
-
Page 10
STH Overview Page 1-2 Connector Ports (TCUs) for connections to stations and other network devices. Figure 1-1. Front and Back Views of the STH-24 Up to four STH hubs can be linked to the same intelligent hub, bringing the total direct connectivity potential to 120 managed TCU ports in the stack. Intelligent hubs serve as the logical “top” of t[...]
-
Page 11
LANVIEW LEDs Page 1-3 1.2.1 LANVIEW LEDs Cabletron Systems’ LANVIEW Status Monitoring and Diagnostics System is a troubleshooting tool. Conveniently located on the fr ont panel, LANVIEW LEDs help the user to quickly identify power failures, beaconing conditions, cable faults, and link problems. Refer to Section 4.1, LANVIEW LED Signals for more i[...]
-
Page 12
Automatic Beacon Recovery Process Page 1-4 wrong ring speed. If a ring speed mismatch is detected, the STH disables the port to keep the misconfigured station isolated fr om the ring and provides a simple visible LED signal (blinking r ed at the port’s LED) to indicate to the user that Speed Fault Protection has disabled the port. The port remai[...]
-
Page 13
Related Manuals Page 1-5 By default, each of the STH hub’s TCU ports is configured to its STN (station) setting to support concentrator lobe connections to stations. Through Local Management, any TCU port may be r econfigured to its RO (Ring Out) setting to support connections to passive MAU (Multi- Station Access Unit) workgroups. Improved Pro[...]
-
Page 14
Related Manuals Page 1-6 Figure 1-2. Improved Beacon Recovery Resolution for MAUs (8 Stations) (8 Stations) (8 Stations) (8 Stations) STH TCUs Ring Out Ring Out Ring Out Ring Out Multi-Station Access Units Ring In Ring In Ring In Ring In When each MAU is individually connected to the STH hub, only one MAU must be bypassed to isolate the hub from a [...]
-
Page 15
Getting Help Page 1-7 1.4 Getting Help If you need additional support related to the Cabletr on Systems STH, or if you have any questions, comments, or suggestions concerning this manual, contact Cabletron Systems T echnical Support: By phone: (603) 332-9400 Monday-Friday; 8am - 8pm EST By CompuServe ® : GO CTRON from any ! prompt By Internet mail[...]
-
Page 16
Page 2-1 CHAPTER 2 REQUIREMENTS & SPECIFIC A TIONS This chapter describes network guidelines, power requir ements, and operating specifications for the STH. Before installing the STH, r ead this chapter and confirm that the network meets the requir ements and conditions specified in this chapter . Failure to follow these guidelines could res[...]
-
Page 17
General Considerations Page 2-2 to re-r oute cabling away from potential noise sour ces, or to ensure that the electrical wiring in the area is pr operly wired and gr ounded, or to replace connectors along af fected segments. Temperature The attenuation of PVC-insulated cable varies significantly with temperature. Check the cable manufactur er ’[...]
-
Page 18
Cable Specifications Page 2-3 • Where practical, dedicated cable should be used for Token Ring signals. • Work area wall plates and outlets used for the Token Ring network should be clearly labeled as Token Ring network lobe connections. 2.2 Cable Specifications T ake care in planning and pr eparing the cabling and connections for the network. [...]
-
Page 19
UTP Cable Categories Page 2-4 Category 3 consists of (usually) four Unshielded T wisted Pairs of 24 A WG solid wire for data or voice communication. (IBM T ype 3 is coincidentally the same as UTP Category 3.) It is typically used to wir e cable runs within the walls of buildings. In some installations, pr e- existing UTP building wiring can be used[...]
-
Page 20
UTP Lobe Lengths Page 2-5 UTP cabling to any non-Token Ring network conductors (telephone, etc.) or ground. If in doubt, test wiring before using. 2.3.2 UTP Lobe Lengths The physical length of the cable connecting a station to a TCU port on the concentrator is referr ed to as the lobe length . The maximum lobe length attainable with the concentrato[...]
-
Page 21
STP Cable Categories Page 2-6 2.4.1 STP Cable Categories The supported STP cable types meet the following specifications: IBM T ype 1 consists of two shielded twisted pairs (STP) of 22 A WG solid wire for data. Used for the longest cable r uns within the walls of buildings. IBM T ype 2 consists of six pairs of unshielded twisted pairs of 24 A WG s[...]
-
Page 22
TCU Specifications Page 2-7 2-4. Cable routing, connector attenuation, noise and cr osstalk can adversely affect the maximum lobe length. Mixed STP Cable Types If cable types are to be mixed in the LAN, compensations must be made for the differ ent cable attenuations. For example, T ype 6 & 9 cables can be run for only 2/3 the distance of T ype[...]
-
Page 23
Operating Specifications Page 2-8 On STH models -42/-44, each RJ45 connector is encased in a metallic shield which provides a means of connection for the STP cable shield. Shield continuity is maintained by contacts within the female RJ45 that contact the metallic casing of the male RJ45 on the STP lobe cabling. Shielded patch cables that adapt a s[...]
-
Page 24
Ring Sequence Page 2-9 Note: When cancelling a MIB override, the user may have to perform the switch and power-cycle procedure twice (as described in the steps below) to actually change the STH hub’s ring speed by the switch. T o return to switch contr ol from an MIB overridden Ring Speed setting: 1. Regain switch control. Change the current swit[...]
-
Page 25
Environmental Requirements Page 2-10 under all conditions of line at full load. The minimum and maximum load current fr om each output is shown below . 2.6.4 En vironmental Requirements Operating Temperature: +5 ° to +50 ° C Non-operating Temperature: -30 ° to +90 ° C Operating Humidity: 5 to 95% (non-condensing) 2.6.5 Safety This equipment is [...]
-
Page 26
Page 3-1 CHAPTER 3 INST ALLATION This chapter outlines the procedur e for installing the STH and adding it to a stack. Confirm that the network meets the guidelines and requir ements outlined in Chapter 2, Installation Requirements/ Specifications , before installing the STH. 3.1 Unpacking the STH Unpack the STH as follows: 1. Carefully remove th[...]
-
Page 27
Adding the STH to a Stack Page 3-2 3.2.2 Adding the STH to a Stack STH hubs are star -wired to the intelligent hub. T o add STH hubs to a stack, refer to Figur e 3-1 and perform the following steps: 1. Attach an STH HubSTACK Interconnect cable to the "STACK" port on the rear panel of an STH. 2. Attach the other end of the cable to one of [...]
-
Page 28
Attaching the Strain Relief Bracket Page 3-3 3.2.3 Attaching the Strain Relief Bracket Attach the strain relief bracket to the fr ont of the STH as follows: 1. Locate the strain relief bracket and four 8-32 x 3/8" screws from the STH-ACCY-KIT package. Warning : Use of longer screws may cause damage to the unit or electrical shock. 2. Carefully[...]
-
Page 29
Wall-Mounting the STH Page 3-4 Figure 3-3. Installing the Rack-Mount Brackets Figure 3-4. Installing the STH in a Rack 3.2.5 Wall-Mounting the STH When an STH is installed on a wall, its cable connections must face down to prevent the sideways str esses of hanging cables from compr omising the connection at the port. Note : 1/4-inch anchors for wal[...]
-
Page 30
Wall-Mounting the STH Page 3-5 Figure 3-5. Installing the Wall Mounting Brackets 2. Select the wall location for the STH within 7 feet of a power outlet. Warning : There is a SHOCK HAZARD whe drilling into walls containing electrical wiring . Select a wall location where drill bits and screw anchors will not come in contact with electrical wiring i[...]
-
Page 31
Free-Standing Installation Page 3-6 Figure 3-6. Wall-mounting the STH 3.2.6 Free-Standing Installation For a free-standing shelf or tabletop installation, install the STH on an unrestricted fr ee surface area 21 inches wide, 18 inches deep and 6 inches high, within 7 feet of its power source, as shown in Figur e 3-7. Figure 3-7. Shelf or Table-top [...]
-
Page 32
Connecting the STH to the Power Source Page 3-7 3.2.7 Connecting the STH to the Power Source Note : The STH has a universal power supply which will accept power sources from 90 Vac to 264 Vac, 47-63 Hz. T o connect the STH to the power source: 1. Plug the power cord into the back panel of the STH. 2. Plug the other end of the power cord into a grou[...]
-
Page 33
Finishing the Installation Page 3-8 c. Check that the twisted pair connection meets dB loss and cable specifications outlined Chapter 2. If a link still has not been established, contact Cabletron Systems T echnical Support. 3.3 Finishing the Installation The STH is now ready for operation. Befor e placing the network into service, test the install[...]
-
Page 34
Page 4-1 CHAPTER 4 TR OUBLESHOO TING This chapter contains instructions for using LANVIEW LEDs to troubleshoot physical layer network pr oblems. 4.1 LANVIEW LED Signals The STH incorporates the Cabletron Systems LANVIEW Status Monitoring and Diagnostics System. LANVIEW LEDs can help diagnose problems such as a power failur e or a cable fault. The S[...]
-
Page 35
Trouble Resolution Page 4-2 Loss Of Power If the STH is having power problems, check the power delivery system (power cable, power outlet, circuit br eaker , fuse). Loss of Contact with Intelligent Hub If the ST ACK LED is indicating disconnection from the intelligent hub, it may be that the intelligent hub has placed the STH in bypass to protect i[...]