Carrier ZONEKIT2ZCAR manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 16 pages
- 0.21 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Air Conditioner
Carrier 50HJ015
18 pages 1.17 mb -
Air Conditioner
Carrier 38CKC036 Air
8 pages 0.19 mb -
Air Conditioner
Carrier 38APS025-050
36 pages 5.2 mb -
Air Conditioner
Carrier 42S
72 pages 14.36 mb -
Air Conditioner
Carrier 48/50PD05
106 pages 3.95 mb -
Air Conditioner
Carrier AIR CONDITIONING UNIT 38TRA
6 pages 0.12 mb -
Air Conditioner
Carrier 50VLA
6 pages 1.95 mb -
Air Conditioner
Carrier 50RHE006-060
32 pages 0.8 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Carrier ZONEKIT2ZCAR. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Carrier ZONEKIT2ZCAR ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Carrier ZONEKIT2ZCAR décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Carrier ZONEKIT2ZCAR devrait contenir:
- informations sur les caractéristiques techniques du dispositif Carrier ZONEKIT2ZCAR
- nom du fabricant et année de fabrication Carrier ZONEKIT2ZCAR
- instructions d'utilisation, de réglage et d’entretien de l'équipement Carrier ZONEKIT2ZCAR
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Carrier ZONEKIT2ZCAR ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Carrier ZONEKIT2ZCAR et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Carrier en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Carrier ZONEKIT2ZCAR, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Carrier ZONEKIT2ZCAR, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Carrier ZONEKIT2ZCAR. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
ZONEKIT2ZCAR WeatherMaker® Two-Zone Installation and Start-Up Instructions NOTE: Read the entire instruction manual before starting the installation. This symbol → indicates a change since the last issue. TABLE OF CONTENTS PAGE Safety Considerations .....................................................................1 Installation Consideration[...]
-
Page 2
Step 2—Wiring To prevent personal injury or possible equipment damage, disconnect the power supply before routing wire. All wiring must comply with local, state, and national codes. NOTE: Use No. 18 AWG color-coded, insulated (35°C min) wire. If thermostats are to be located more than 100 ft from the WeatherMaker Two-Zone Center as measured alon[...]
-
Page 3
2. Properly seal joint using duct tape, mastic, or other approved method. Do not allow mastic to come in contact with actuator. 3. Insulate damper using 1-1/2-in. to 2-in. insulation. (Check your local codes.) (See Fig. 7.) NOTE: All zone dampers and ductwork must be properly sup- ported according to local codes or SMACNA standards. NOTE: There sho[...]
-
Page 4
Step 5—Install Barometric Bypass Damper NOTE: The barometric bypass damper is a critical part of the WeatherMaker Two-Zone System for control of minimum airflow and noise reduction. It is recommended that the bypass be installed. The bypass should be installed according to local codes and SMACNA standards. Be sure the bypass is properly supported[...]
-
Page 5
In automatic changeover, the zoning system works on a first come first serve basis. If 1 zone is calling for heating and the other for cooling, the zone which sent its demand to the I/O center first will operate the equipment in that mode until that zone is satisfied. Step 5—Duct Temperature Optimizer (DTO) For Monitoring Leaving Air Temperature [...]
-
Page 6
Fig. 12—WeatherMaker Two-Zone Circuit Board with Standard Thermostat Wiring A97293 3 Thermostat Zone 2 Y 2 Y 1 R W 1 W 2 C G Thermostat Zone 1 Y 2 Y 1 R W 1 W 2 C Sensors HP Duct Equipment R c B O Y 2 Y 1 W 1 W 2 G R h 24 VAC Power 24 v CL OP C Zone 1 Damper Zone 2 Damper CL OP C G B D 4 F A E C K J I H L M N 2 3 1 ZONE 1?[...]
-
Page 7
NOTE: An HP temperature sensor must be used with a heat pump application using electric strip heat. This is necessary in case the DTO is set to the Off position. Timeguard The WeatherMaker Two-Zone provides equipment protection with an internal 5-minute timeguard delay. This delay is present upon initial power up. There is also a 5-minute timeguard[...]
-
Page 8
timer will start counting down 15, 14, 13...0 minutes. Once the timer expires the control will allow a new mode to restart the equipment. The internal time, as well as the cooling 5-minute timeguard can be cleared by using the comprotec override feature. CARE AND MAINTENANCE For continuing optimum performance and to minimize possible equipment fail[...]
-
Page 9
TROUBLESHOOTING This section contains information to assist you in troubleshooting problems and errors associated with the WeatherMaker Two-Zone system. See Table 2. Step 1—System Diagram, Jumpers, and Switches NOTE: For correct control board operation, it must have either a sensor attached or a 10k resistor in place at the duct and HP inputs. 1 [...]
-
Page 10
I Red LED—Displays ON when fan is energized. J Red LED—Displays ON when first-stage cooling is energized. K Red LED—Displays ON when second-stage cooling is energized. L Red LED—Displays ON when reversing valve is ener- gized. M Red LED—Displays ON when first-stage heat is energized. N Red LED—Displays ON when second-stage heat is energ[...]
-
Page 11
Table 3 shows a temperature/ohm/voltage relationship to help aid in troubleshooting the WeatherMaker Two-Zone System. This table will evaluate both the Duct/HP temperature sensor operation. Use a digital multimeter to perform the following: To verify a sensor is good, disconnect both leads from the I/O board and measure the resistance through the s[...]
-
Page 12
→ Fig. 17—Typical Fan Coil With Single-Speed Air Conditioner A97298 SINGLE-SPEED AIR CONDITIONER TYPICAL FAN COIL C Y G W2 W3 C R Y/Y2 O L E RH G W2 W1 Y1 Y2 O B RC TWO-ZONE SYSTEM See notes 1 and 3 * * * * * Y1 * * → Fig. 15—Single-Stage Furnace With Single-Speed Air Conditioner A97296 SINGLE-SPEED AIR COND[...]
-
Page 13
→ Fig. 21—Typical Fan Coil With 2-Speed Air Conditioner A97302 2-SPEED AIR CONDITIONER TYPICAL FAN COIL R G R C W2 Y/Y2 E W3 L O Y1 C Y2 Y1 RH G W2 W1 Y1 Y2 O B RC TWO-ZONE SYSTEM See notes 1, 2, and 3 * * * * * → Fig. 19—Single-Stage Furnace With 2-Speed Air Conditioner A97300 2-SPEED AIR CONDITIONER SINGLE[...]
-
Page 14
→ Fig. 23—Single-Stage Furnace With Single-Speed Heat Pump A97304 SINGLE-STAGE FURNACE TWO-ZONE SYSTEM INTERFACE CONTROL R GF RF WF R GT E HP O HP OT Y HP C W2 Y O RH G W2 W1 Y1 Y2 O B RC G R W C SINGLE-SPEED HEAT PUMP YT E T C Y 2 1 3 OUTDOOR THERMOST A T (KHAO T0301FST) See notes 4, 5, 6, a[...]
-
Page 15
→ Fig. 27—Single-Stage Furnace With 2-Speed Heat Pump A97308 2-SPEED HEAT PUMP SINGLE-STAGE FURNACE R G R C W Y C Y2 W3 RH G W2 W1 Y1 Y2 O B RC TWO-ZONE SYSTEM W2 Y1 O See notes 2, 5, 6, 7, 9, 10, and 11 → Fig. 25—Typical Fan Coil With Single-Speed Heat Pump A97306 SINGLE-SPEED HEAT PUMP TWO-ZONE SYSTEM TYPI[...]
-
Page 16
→ Fig. 29—Typical Fan Coil With 2-Speed Heat Pump A97310 RH G W2 W1 Y1 Y2 O B RC 2-SPEED HEAT PUMP TYPICAL FAN COIL C G W2 Y/Y2 R C W3 L E Y1 R W2 O W3 Y1 Y2 O TWO-ZONE SYSTEM See notes 1, 2, 3, 9, and 11 * * * * * → Fig. 30—FK4C Fan Coil With 2-Speed Heat Pump A97311 FK4C FAN COIL R R G W1 C DH W2 Y1 Y/Y2 O[...]