Continental CBI 360-P manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 16 pages
- 2.41 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Refrigerator
Continental USC-20
12 pages 0.44 mb -
Toaster
Continental CP43579
16 pages 5.23 mb -
Refrigerator
Continental USA-20
12 pages 0.44 mb -
Refrigerator
Continental USWC-30
12 pages 0.44 mb -
Hot Beverage Maker
Continental CE23691
8 pages 13.93 mb -
Refrigerator
Continental DL2WI-SS-E
2 pages 0.12 mb -
Automobile Accessories
Continental KL83129
12 pages 2.01 mb -
Indoor Fireplace
Continental CDVS500-P
24 pages 4.7 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Continental CBI 360-P. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Continental CBI 360-P ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Continental CBI 360-P décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Continental CBI 360-P devrait contenir:
- informations sur les caractéristiques techniques du dispositif Continental CBI 360-P
- nom du fabricant et année de fabrication Continental CBI 360-P
- instructions d'utilisation, de réglage et d’entretien de l'équipement Continental CBI 360-P
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Continental CBI 360-P ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Continental CBI 360-P et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Continental en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Continental CBI 360-P, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Continental CBI 360-P, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Continental CBI 360-P. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
1 W415-0120 / E / 01.1 1.05 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .continentalfireplaces.com • ask@continentalfire.com CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS, CSA 2.22, AND ANSI Z21[...]
-
Page 2
2 W415-0120 / E / 01.1 1.05 P G 2 -5 INTRODUCTION Warranty General Instructions General Information Care of Glass, & Plated Parts 5- 6 IN ST ALLA TION 7 -8 FINISHING Brick panels Log Placement/Charcoal Embers Louvre Installation Logo Placement 8 OPERA TION / MAINTEN ANCE S pill Switch V enting Action Check 9 OPERA TION / MAINTEN ANCE CONT &apos[...]
-
Page 3
3 W415-0120 / E / 01.1 1.05 CONTINENTAL gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. CONTINENTAL products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak a[...]
-
Page 4
4 W415-0120 / E / 01.1 1.05 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERVICED BY A QUALIFIED INST ALLER to conform with local codes. Installation practices vary from region to re- gion and it is important to know the specifics that apply to your area, for example: in Massachusett s S t ate: • The fireplace damper must be removed or welded in t[...]
-
Page 5
5 W415-0120 / E / 01.1 1.05 Line the chimney with a 3" or 4" diameter approved liner . With a 4" liner , an increaser must be connected between the dilution draft hood and the liner . Chimney installation must conform to both national and local code requirements. The liner must be continuous from the fireplace to the chimney cap. Rem[...]
-
Page 6
6 W415-0120 / E / 01.1 1.05 FIGURE 5 An on/off switch has been included and can be located at the right side trim. For ease of accessibility , this switch may be replaced with a wall switch or substituted with a millivolt thermostat that may be installed in a convenient location on any wall. Route a 2 strand solid core millivolt wire through the el[...]
-
Page 7
7 W415-0120 / E / 01.1 1.05 FIGURE 6 T o give your insert that authentic masonry fireplace look, optional fibre firebrick panels are available at your Conti- nental / Wolf S teel Ltd. dealer . Complete installation and maintenance instructions are included with the kit. PHAZER TM logs and charcoal embers, exclusive to Conti- nental Fireplaces, prov[...]
-
Page 8
8 W415-0120 / E / 01.1 1.05 When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condi- tion caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to sufficiently ventil[...]
-
Page 9
9 W415-0120 / E / 01.1 1.05 TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPLACE. CAUTION: Label all wires prior to disconnection when ser- vicing controls. Wiring errors can cause improper and dan- gerous operation. V erify proper operation after servicing. This insert and its venting system should be inspected before use and at le[...]
-
Page 10
10 W415-0120 / E / 01.1 1.05 FIGURE 12 FIGURE 1 1 FIGURE 12 FIGURE 13 FIGURE 14 The Continental gas fireplace insert comes standard with a blower , a heat sensor , variable on/off speed control and a power cord. Because the blower is thermally activated, when turned on, it will automatically start approximately 15 minutes after lighting the firepla[...]
-
Page 11
11 W415-0120 / E / 01.1 1.05 # P ART # DESCRIPTION 1 GL-610 LOG SET ASSEMBL Y C / W CHARCOAL EMBERS 2 W135-0007 BACK LOG 3 W135-0052 FRONT LOG 4 W135-0015 RIGHT LOG 5 W135-0016 LEFT LOG 6 W135-0009 CENTER LOG 7* W550-0001 CHARCOAL EMBERS 8* W385-0131 CONTINENT AL LOGO 9 W725-0036 NA TURAL GAS V AL VE - REMOTE RBT SHAW 9 W725-0037 PROP ANE GAS V AL [...]
-
Page 12
12 W415-0120 / E / 01.1 1.05[...]
-
Page 13
13 W415-0120 / E / 01.1 1.05 Pilot goes out when the gas knob is re- leased. System is not correctly purged. Out of propane gas. - purge the gas line with the glass door removed. - fill the tank. - gently twist the pilot head to improve the flame pattern around the thermopile. Pilot flame is not large enough Pilot flame is not engulfing the thermop[...]
-
Page 14
14 W415-0120 / E / 01.1 1.05 Main burner goes out; pilot goes out. Refer to "Main burner goes out; pilot stays on" Liner disconnected from insert. - wait ten minutes. Shut off all exhaust fans in the house (ie: kitchen and bathrooms), furnace, and clothes dryer . Open windows and/or doors. S tart fireplace and monitor its opera- tion. Clo[...]
-
Page 15
15 W415-0120 / E / 01.1 1.05 W olf Steel Fireplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer Name[...]
-
Page 16
16 W415-0120 / E / 01.1 1.05 NO TES[...]