Crestron electronic DIN-8SW8 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 32 pages
- 3.58 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Switch
Crestron electronic DMC-CATO-HD
1 pages 0.25 mb -
Switch
Crestron electronic CNX-PVID8x4
44 pages 1.93 mb -
Switch
Crestron electronic CLX-4HSW4
1 pages 0.47 mb -
Switch
Crestron electronic SRD-CPL-4
12 pages 1.24 mb -
Switch
Crestron electronic CEN-SW-POE-5
24 pages 1.48 mb -
Switch
Crestron electronic DM-CONN-20
2 pages 0.51 mb -
Switch
Crestron electronic DM-MD8X8
3 pages 1.69 mb -
Switch
Crestron electronic CLW-SWS1/4RF
44 pages 1.6 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Crestron electronic DIN-8SW8. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Crestron electronic DIN-8SW8 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Crestron electronic DIN-8SW8 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Crestron electronic DIN-8SW8 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Crestron electronic DIN-8SW8
- nom du fabricant et année de fabrication Crestron electronic DIN-8SW8
- instructions d'utilisation, de réglage et d’entretien de l'équipement Crestron electronic DIN-8SW8
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Crestron electronic DIN-8SW8 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Crestron electronic DIN-8SW8 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Crestron electronic en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Crestron electronic DIN-8SW8, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Crestron electronic DIN-8SW8, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Crestron electronic DIN-8SW8. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Crestron Green Light™ DIN-8SW8 DIN Rail High-Voltage Switch Operations & Installation Guide[...]
-
Page 2
This document was prepared and written by th e Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand nam es, product names and trademarks are the property of their respective owners . ©2008 Crestron Electronics, Inc.[...]
-
Page 3
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Contents Crestron Green Light™ DIN Rail High-Voltage Switch: DIN-8SW8 1 Introduction ............................................................................................................................... 1 Features and F unctions ..............................................................[...]
-
Page 4
[...]
-
Page 5
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Crestron Green Light™ DIN Rail High-Voltage Switch: DIN-8SW8 Crestron Green Light™ DIN Rail High-Voltage Switch: DIN-8SW8 Introduction Introduction The DIN-8SW8 is an eight cha nnel high-voltage switching module designed to support switching of non-dimmable lighting and fans. A single model support[...]
-
Page 6
DIN Rail High-Voltage Switch Crestron DIN-8SW8 DIN Rail Installation The DIN-8SW8 is designed to sn ap onto a standard DIN rail for installation in a wall mount enclos ure. Wiring connections are made using screw terminals positioned al ong the top and bottom , clearly accessible from the front for easy inst allation and servicing. All setup contro[...]
-
Page 7
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Applications The following diagram shows a DIN-8S W8 in a typical application. DIN-8SW8 in a Typical Application Operations & Installation Guide – DOC. 6666A DIN Rail Hi gh-Voltage Switch: DIN-8SW8 • 3[...]
-
Page 8
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Specifications Specifications for the DIN-8SW8 ar e listed in the following table. DIN-8SW8 Specifications SPECIFICATION DETAILS Load Ratings Switch Channels 8 Maximum Per Channel 10 Amps incandescent, 5 Amps fluorescent, 0.5 HP @ 120-240 Volts AC, 50/60 Hz; 5 Amps @ 30 Volts DC Minimum Per Channel 0.0[...]
-
Page 9
Crestron DIN-8SW8 DIN Rail High-Voltage Switch DIN-8SW8 Specifications (Continued) SPECIFICATION DETAILS Enclosure Light gray polycarbonate housing with polycarbonate label overlay, UL94 V-0 rated, 35 mm DIN EN 60715 rail mount, DIN 43880 form factor for enclosures with 45 mm front panel cutout, occupies 9 DIN module spaces (162 mm) Dimensions Heig[...]
-
Page 10
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Physical Description This section provides information on the connections, controls and indicators available on your DIN-8SW8. DIN-8SW8 Physical View DIN-8SW8 Overall Dimensions 58 mm (2.29 in) 59.5 mm (2.35 in) 94.2 mm (3.71 in) 90 mm (3.55 in) 159 mm (6.26 in) 1 1 2 3 4 5 6 7 8 5 6 • DIN Rail High-[...]
-
Page 11
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Connectors, Controls & Indicators # CONNECTORS * , CONTROLS & INDICATORS DESCRIPTION 1 1 – 8 and LEDs (8) Sets of (2) captive screw terminals; Isolated Class 1 SPST relay switch circuits 1-8; Relay rating: 10 Amps incandescent 5 Amps fluorescent 16 Amps resistive 0.5 HP @ 120-240 Volts AC (pe[...]
-
Page 12
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Connectors, Controls & Indicators (Continued) # CONNECTORS * , CONTROLS & INDICATORS DESCRIPTION 4 SETUP (LED and BUTTON) (1) Red LED and (1) recessed miniature pushbutton for enabling setup mode and touch-settable ID 5 OVERRIDE with LEDs and BUTTON (2) 2-pin 3.5 mm detachable terminal blocks, [...]
-
Page 13
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Industry Compliance This unit has been manufactured to comply with UL’s Standards for Safety in Canada and the United St ates. Formal approval is pending. As of the date of manufacture, the DIN-8SW8 has been tested and found to comply with specifications for CE marking and st andards per EMC and Radi[...]
-
Page 14
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Setup Network Wiring When wiring the Cresnet network, consider the following: • Use Crestron Certified Wire. NOTE: Cresnet HP cannot be used. • Use Crestron power supplies for Crestron equipment. • Provide sufficient power to the system. CAUTION: Insufficient power can l ead to unpredictable resu[...]
-
Page 15
Crestron DIN-8SW8 DIN Rail High-Voltage Switch • When the desired Net ID is displayed, press the SETUP button to exit the Setup mode. The SETUP LED extinguishes. NOTE: If an invalid Net ID is se t (00, 02, FF), “Er” will be displayed on the NET ID display. The DIN-8SW8 will revert to the previously set Net ID. NOTE: The DIN-8SW8 will leave th[...]
-
Page 16
DIN Rail High-Voltage Switch Crestron DIN-8SW8 The DIN-8SW8 is designed for insta llation on a DIN rail. Refer to the following diagram when installing. Installing the DIN-8SW8 DIN RAIL RELEASE DIN RAIL (NOT SUPPLIED) DIN-8SW8 TOP 1. Place the top of the DIN-8SW8’s rail mount over the top of the DIN rail. 2. Tilt the bottom of the DIN-8SW8 toward[...]
-
Page 17
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Hardware Hookup Make the necessary connections as called out in the illustration that follows this paragraph. Refer to “ Network Wiring ” on page 10 before attaching the 4-position terminal block connector. Apply power after all connections have been made. WARNING: Prior to connecting the device, t[...]
-
Page 18
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Hardware Connections for the DIN-8SW8 NET: TO CONTROL SYSTEM A ND OTHER CRESNET DEVI CES OVERRIDE: FROM DEVICE PROVIDING OVERRIDE S IGNAL & TO OTHER DEVICES RECEIV I NG OVERRIDE SI GNAL 1 - 8: CONNECTIONS FOR CONTROLLED DEVICE S With the circuit breaker turned off, connect the wires to the terminal[...]
-
Page 19
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Programming Software Have a question or comment about Crestron software? Answers to frequently asked questi ons (FAQs) can be viewed in the Online Help section of the Crestron website. To post a question or view questions you have submitted to Crestr on’s True Blue Support, log in at http://support.c[...]
-
Page 20
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Programming with D3 Pro Crestron’s D3 Pro lighting software provides all the tools necessary to create a complete Crestron lighting sy stem for residential applications. The lighting system includes the control system logic program, touchpanel projects and keypad prog ramming, documentation and real-[...]
-
Page 21
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Locating the DIN-8SW8 in the Device Library • The system tree of the control sy stem disp lays the device in the appropriate slot with a default Net ID as shown in the following illustration. C2Net Device, Slot 5 • Additional DIN-8SW8 devices ar e assigned different Net ID numbers as they are added[...]
-
Page 22
DIN Rail High-Voltage Switch Crestron DIN-8SW8 • If necessary, double click a device to open the “Device Settings” window and change the Net ID, as shown in the following figure. “DIN-8SW8 Device Settings” Window • The ID code specified in th e SIMPL Windows program must match the Net ID of each unit. Refer to “ Identity Code ” whic[...]
-
Page 23
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Uploading and Upgrading Crestron recommends using the lat est programming software and that each device contains the latest firm ware to take advantage of the most recently released features. However, before atte mpting to upload or upgrade it is necessary to establis h communication. Once co mmunicati[...]
-
Page 24
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Programs and Firmware Program or firmware files m ay be distributed from programmers to installers or from Crestron to dealer s. Firmware upgrades are available from the Crestron website as new fe atures are developed after product releases. One has the option to upload programs via the programming sof[...]
-
Page 25
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Operation NET ID Use the NET ID buttons to change the Net ID of the DIN-8SW8. For information on Net ID, refer to “ Identity Code ” which starts on page 10 . Manual Control The state of each output can be manua lly controlled from the front panel. To toggle the output between off a nd on, tap the a[...]
-
Page 26
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Save Override Settings The state of each output can be saved as an override setti ng, which can be automatically recalled when the Override mode is enabled. NOTE: The control system program has a setting that can prevent locally saving the override state. If this setting is enabled, the display shows ?[...]
-
Page 27
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. DIN-8SW8 Troubleshooting TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION DIN-8SW8 is not receiving po[...]
-
Page 28
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Check Network Wiring Use the Right Wire In order to ensure optimum perf ormance over the full range of your installation topology, Crestron Certifie d Wire and only Crestron Certifie d Wire may be used. Failure to do so may incur additional charges if support is required to identify perform ance defici[...]
-
Page 29
Crestron DIN-8SW8 DIN Rail High-Voltage Switch NOTE: All Crestron certified Cresne t wiring must consist of two twisted pairs. One twisted pair is the +24V conductor and the GND conductor and the other twisted pa ir is the Y conductor and the Z conductor. Strip and Tin Wire When daisy-chaining Cresnet units, st rip the ends of the wires carefully t[...]
-
Page 30
DIN Rail High-Voltage Switch Crestron DIN-8SW8 Future Updates As Crestron improves functions, adds new features and extends the capabilities of the DIN-8SW8, additi onal information may be made available as manual updates. Thes e updates are solely electronic and serve as intermediary supplements pr ior to the release of a complete technical docume[...]
-
Page 31
Crestron DIN-8SW8 DIN Rail High-Voltage Switch Return and Warranty Policies Merchandise Returns / Repair Service 1. No m erchandise may be returned f or credit, exchange or service with out prior authorization from CR ESTRON. To obtain war ranty serv ice for CRESTRON products, contact an authorized CRESTRON deal er. Only authorized CRESTRON dealers[...]
-
Page 32
Crestron Electronics, Inc. Operations & Installation Guide – DOC. 6666A 15 Volvo Drive Rockleigh, NJ 07647 (2020748) Tel: 888.CRESTRON 05.08 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.[...]