Cypress CY7C1354C manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 28 pages
- 0.5 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Computer Hardware
Cypress CY7C1386F
30 pages 1.21 mb -
Computer Hardware
Cypress CY62157CV33
13 pages 1.8 mb -
Computer Hardware
Cypress CY7C0850AV
32 pages 0.95 mb -
Computer Hardware
Cypress CY14B104NA
23 pages 0.73 mb -
Computer Hardware
Cypress CY7C604XX
30 pages 0.7 mb -
Computer Hardware
Cypress CY7C1566V18
28 pages 0.7 mb -
Computer Hardware
Cypress CY62136VN
12 pages 0.56 mb -
Computer Hardware
Cypress CYDC064B16
26 pages 0.59 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Cypress CY7C1354C. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Cypress CY7C1354C ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Cypress CY7C1354C décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Cypress CY7C1354C devrait contenir:
- informations sur les caractéristiques techniques du dispositif Cypress CY7C1354C
- nom du fabricant et année de fabrication Cypress CY7C1354C
- instructions d'utilisation, de réglage et d’entretien de l'équipement Cypress CY7C1354C
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Cypress CY7C1354C ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Cypress CY7C1354C et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Cypress en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Cypress CY7C1354C, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Cypress CY7C1354C, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Cypress CY7C1354C. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
9-Mbit (256K x 36/512K x 18) Pi p elined SRAM with NoBL™ Architecture CY7C1354C CY7C1356C Cypress Semiconductor Corpora tion • 198 Champion Cou rt • San Jose , CA 95134-1 709 • 408-943-2 600 Document #: 38-05538 Rev . *G Revised September 14, 2006 Features • Pin-comp atible an d functionally eq uiv a le nt to ZBT ™ • Supports 250-MHz [...]
-
Page 2
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 2 of 28 A0, A1, A C MODE BW a BW b WE CE1 CE2 CE3 OE READ LOGIC DQs DQP a DQP b D A T A S T E E R I N G O U T P U T B U F F E R S MEMORY ARRAY E E INPUT REGISTER 0 ADDRESS REGISTER 0 WRITE ADDRESS REGISTER 1 WRITE ADDRESS REGISTER 2 WRITE REGISTRY AND DATA COHERENCY CONTROL LOGIC BURST LOGIC A0[...]
-
Page 3
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 3 of 28 Pin Configurations A A A A A 1 A 0 V SS V DD A A A A A A V DDQ V SS DQb DQb DQb V SS V DDQ DQb DQb V SS NC V DD DQa DQa V DDQ V SS DQa DQa V SS V DDQ V DDQ V SS DQc DQc V SS V DDQ DQc V DD V SS DQd DQd V DDQ V SS DQd DQd DQd V SS V DDQ A A CE 1 CE 2 BWa CE 3 V DD V SS CLK WE CEN OE NC(1[...]
-
Page 4
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 4 of 28 Pin Configurations (continued) 234 5 6 7 1 A B C D E F G H J K L M N P R T U DQ a V DDQ NC/576 M NC/1G DQ c DQ d DQ c DQ d AA A A NC/18M V DDQ CE 2 A V DDQ V DDQ V DDQ V DDQ NC/144 M NC A DQ c DQ c DQ d DQ d TMS V DD A NC/72M DQP d A A ADV/LD AC E 3 NC V DD AA N C V SS V SS NC DQP b DQ [...]
-
Page 5
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 5 of 28 Pin Configurations (continued) 23 4 567 1 A B C D E F G H J K L M N P R TDO NC/576M NC/1G DQP c DQ c DQP d NC DQ d A CE 1 BW b CE 3 BW c CEN A CE2 DQ c DQ d DQ d MODE NC DQ c DQ c DQ d DQ d DQ d NC/36M NC/72M V DDQ BW d BW a CLK WE V SS V SS V SS V SS V DDQ V SS V DD V SS V SS V SS NC V[...]
-
Page 6
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 6 of 28 Pin Definitions Pin Name I/O T ype Pin Description A0, A1 A Input- Synchronous Address Inp ut s used to select on e of the addre ss locations . Sampled at the rising edge of the CLK. BW a ,BW b , BW c ,BW d , Input- Synchronous Byte Write Select Inpu t s, active LOW . Qualified with WE [...]
-
Page 7
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 7 of 28 Functional Overview The CY7C1354C and C Y7C1356C are synchronous-pipeli ned Burst NoBL SRAMs designed specifically to eliminate wait states during Write/Read transi tions. All synchronous input s pass through input registers co ntrolled by the rising ed ge of the clock. The clock signal[...]
-
Page 8
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 8 of 28 Because the CY7C1354C and CY7C1356C are common I/O devices, data should not be driv en into the device while the outputs are active. The Output Enable (OE ) can be deasserted HIGH before presenting data to the DQ and DQP (DQ a,b,c, d /DQP a,b,c,d for C Y7C1354C and DQ a,b /D QP a,b for [...]
-
Page 9
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 9 of 28 NOP/WRITE ABORT (Begin Burst) None L L L L H X L L-H Tri-S tate WRITE ABORT (Continue Burst) Next X L H X H X L L-H Tri-S tate IGNORE CLOCK EDGE (S t all) Current X L X X X X H L-H - SLEEP MODE None X H X X X X X X T ri-S tate Partial Write Cycle Description [2, 3, 4, 9] Function (CY7C1[...]
-
Page 10
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 10 of 28 IEEE 1 149.1 Serial Boundary Scan (JT AG) The CY7C1354C/CY7C1356C incorpora tes a serial boundary scan test access port (T AP) in th e BGA package only . The TQFP package does not offer this functionality . This part operates in accordance with IEEE S t andard 1 149.1-1900, but doesn?[...]
-
Page 11
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 1 1 of 28 TDI and TDO ba lls as show n in the T ap Co ntroller Bl ock Diagram. Upon power-up, the instruction register is loaded with the IDCODE in struction. It is also loaded with the IDCODE instruction if the controller is placed in a reset state as described in th e pre v i o us section. Wh[...]
-
Page 12
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 12 of 28 PRELOAD allows an initial data pattern to be placed at the latched parallel outputs of the boundary scan register cells prior to the selection o f another boundary scan test operation. The shifting of data for the SAMPLE and PRELOAD phases can occur concurrently when required—that is[...]
-
Page 13
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 13 of 28 3.3V T AP AC T est Conditions Input pulse levels .................. .............. .............. .. V SS to 3.3V Input rise and fall times ......... ........ ........... ... ........... ... ...... 1 ns Input timing referenc e levels .................... ........... ............1.5V Ou[...]
-
Page 14
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 14 of 28 Scan Register Sizes Register Name Bit Size (x36) Bit Size (x18) Instruction 3 3 Bypass 1 1 ID 32 32 Boundary Scan Order (1 19-b all BGA package) 69 69 Boundary Scan Order (165-ball FBGA package) 69 69 Identification Codes Instruct ion Code Descri ption EXTEST 000 Captures the Input/Out[...]
-
Page 15
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 15 of 28 Boundary Scan Exit Order (256K × 36) Bit # 1 19-ball ID 165-ball ID 1K 4 B 6 2H 4 B 7 3M 4 A 7 4F 4 B 8 5B 4 A 8 6G 4 A 9 7C 3 B 1 0 8B 3 A 1 0 9D 6 C 1 1 10 H7 E10 11 G 6 F 1 0 12 E6 G10 13 D7 D10 14 E7 D1 1 15 F6 E1 1 16 G7 F1 1 17 H6 G1 1 18 T7 H1 1 19 K7 J10 20 L6 K10 21 N6 L10 22[...]
-
Page 16
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 16 of 28 Boundary Scan Exit Order (512K × 18) Bit # 1 1 9-ball ID 165-ball ID 1K 4 B 6 2H 4 B 7 3M 4 A 7 4F 4 B 8 5B 4 A 8 6G 4 A 9 7C 3 B 1 0 8B 3 A 1 0 9T 2 A 1 1 10 Not Bonded (Preset to 0) Not Bonded (Preset to 0) 1 1 Not Bonded (Preset to 0) Not Bonded (Preset to 0) 12 Not Bonded (Preset [...]
-
Page 17
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 17 of 28 Maximum Ratings (Above which the useful life may be impaired. For user guide- lines, not tested.) S torage T emperature ............. .............. ...... –65°C to +150°C Ambient T emperature with Power Applied ........... ............................ ...... –55°C to +125°C Su[...]
-
Page 18
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 18 of 28 Cap acit ance [16] Parameter Des criptio n T est Conditions 100 TQ FP Max. 1 19 BGA Max. 165 FBGA Max. Unit C IN Input Capacitance T A = 25 ° C, f = 1 MHz, V DD = 3.3V V DDQ = 2.5V 55 5 p F C CLK Clock Input Capacitance 5 5 5 pF C I/O Input/Output Capacit ance 5 7 7 pF Thermal Resist [...]
-
Page 19
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 19 of 28 Switching Characteristics Over the Operating Range [18, 19] Parameter Description –250 –200 –166 Unit Min. Max. Min. Max. Min. Max. t Power [17] V CC (typical) to the First Access Read or Write 1 1 1 ms Clock t CYC Clock Cycle T ime 4.0 5 6 ns F MAX Maximum Operating Frequency 25[...]
-
Page 20
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 20 of 28 Switching W aveforms Read/Write T iming [23, 24, 25] Notes: 23. For this waveform ZZ is tied low . 24. When CE is LOW, CE 1 is LOW , CE 2 is HIGH and CE 3 is LOW . When CE is H IGH, CE 1 is HIGH or CE 2 is LOW or CE 3 is HIGH. 25. Order of the Burst sequence is determined by the st atu[...]
-
Page 21
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 21 of 28 NOP ,ST ALL and DESELECT Cycles [23, 24, 26] Note: 26. The IGNORE CLOCK EDGE or ST ALL cycle (Clock 3) illustrated CEN being used to create a pause. A wr ite is not perform ed during this cycle. Switching W aveforms (continued) READ Q(A3) 456789 1 0 CLK CE WE CEN BW X ADV/LD ADDRESS A3[...]
-
Page 22
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 22 of 28 27. Device must be deselected when entering ZZ mode. See cycle descr ipt ion table for all possible signal co nditions to deselect the device. 28. I/Os are in High-Z when exiting ZZ sleep mode. ZZ Mode Timing [27, 28] Switching W aveforms (continued) t ZZ I SUPPLY CLK ZZ t ZZREC A LL I[...]
-
Page 23
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 23 of 28 Ordering Information Not all of the spe ed, package and temperature ran ges are available. Please contact your local sales r epresentative or visit www .cypress.com for actual pro duct s offered. Speed (MHz) Ordering Code Package Diagram Part and Packa ge T ype Operating Range 166 CY7C[...]
-
Page 24
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 24 of 28 250 CY7C1354C-250AXC 51-8 5050 100-pin Thin Quad Flat Pack (14 x 20 x 1.4 mm) Lead-Free Commercial CY7C1356C-250AXC CY7C1354C-250BGC 51-851 15 1 19-ball Ball Grid Array (14 x 22 x 2.4 mm) CY7C1356C-250BGC CY7C1354C-250BGXC 51-851 15 1 19-ball Ball Grid Array (14 x 22 x 2.4 mm) Lead-Fre[...]
-
Page 25
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 25 of 28 Package Diagrams NOTE: 1. JEDEC STD REF MS-026 2. BODY LENGTH DIMENSION DOES NOT INCLUDE MOLD PROTRUSION/END FLASH MOLD PROTRUSION/END FLASH SHALL NOT EXCEED 0.0098 in (0.25 mm) PER SIDE 3. DIMENSIONS IN MILLIMETERS BODY LENGTH DIMENSIONS ARE MAX PLASTIC BODY SIZE INCLUDING MOLD MISMAT[...]
-
Page 26
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 26 of 28 Package Diagrams (continued) 1.27 20.32 2 16 5 4 37 L E A B D C H G F K J U P N M T R 12.00 19.50 30° TYP. 2.40 MAX. A1 CORNER 0.70 REF. U T R P N M L K J H G F E D C A B 21 43 65 7 Ø1.00(3X) REF. 7.62 22.00±0.20 14.00±0.20 1.27 0.60±0.10 C 0.15 C B A 0.15(4X) Ø0.05 M C Ø0.75±0[...]
-
Page 27
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 27 of 28 © Cypress Semi con duct or Cor po rati on , 20 06 . The information con t a in ed he re i n is su bject to change wi t hou t n oti ce. C ypr ess S em ic onduct or Corporation assumes no resp onsibility f or the u se of any circuitry o ther than circui try embodied i n a Cypress prod u[...]
-
Page 28
CY7C1354C CY7C1356C Document #: 38-05538 Rev . *G Page 28 of 28 Document History Page Document Title: CY7C1354C/CY7C1356C 9-Mbit (256K x 36/5 12K x 18) Pipelined SRAM with NoBL™ Architecture Document Number: 38-05538 REV . ECN No. Issue Date Orig. of Change Description of Cha ng e ** 242032 See ECN RKF New dat a sheet *A 278130 Se e ECN RKF Chang[...]