Delta Electronics Series E36SR manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 15 pages
- 0.65 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Power Supply
Delta Electronics SIC73
1 pages 0.18 mb -
Power Supply
Delta Electronics HMS1365MH
1 pages 0.15 mb -
Power Supply
Delta Electronics S48SS
12 pages 0.31 mb -
Power Supply
Delta Electronics RM8
2 pages 0.27 mb -
Power Supply
Delta Electronics SILM104
1 pages 0.08 mb -
Power Supply
Delta Electronics SMT Power Inductor SIWCM73L
1 pages 0.1 mb -
Power Supply
Delta Electronics PFC2811V Series
1 pages 0.1 mb -
Power Supply
Delta Electronics Suppression Inductors LFZ24H
1 pages 0.13 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Delta Electronics Series E36SR. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Delta Electronics Series E36SR ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Delta Electronics Series E36SR décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Delta Electronics Series E36SR devrait contenir:
- informations sur les caractéristiques techniques du dispositif Delta Electronics Series E36SR
- nom du fabricant et année de fabrication Delta Electronics Series E36SR
- instructions d'utilisation, de réglage et d’entretien de l'équipement Delta Electronics Series E36SR
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Delta Electronics Series E36SR ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Delta Electronics Series E36SR et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Delta Electronics en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Delta Electronics Series E36SR, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Delta Electronics Series E36SR, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Delta Electronics Series E36SR. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
FEATURES High efficiency: 89% @ 5V/ 15A Size: 58.4mm x 22.8mm x 9.2mm (2.30”x0.90”x0.36”) Industry standard pin out 18~75V extremely wide 4:1 input r ange Fixed frequency operation Input UVLO, Output OCP , OVP and OTP 2250V isolation Basic insulation No minimum load required SMD and through-hole version[...]
-
Page 2
TECHNICAL SPECIFICA TIONS (T A =25°C, airflow rate=300 LFM, V in =48Vdc, nominal V out unless otherw ise noted.) PA R A M E T E R NOTES and CONDITIONS E36SR05015 (St andard) Min. T y p. Max. U nits ABSOLUTE MAXIMUM RA TINGS Input V oltage Continuous 18 24/48 75 Vdc T ransient (100ms) 100ms 100 Vdc Operating T emperature Refer to Figure 21 for meas[...]
-
Page 3
ELECTRICAL CHARACTERISTICS CUR VES Figure 1: Efficiency vs. load current for minimum, nominal, and maximum in put voltage at 25°C. DS_E36SR05015_010 42008 3 Figure 2: Power dissipation vs. load current for min imum, nominal, and max i mum input voltage at 25°C. Figure 3: T ypical full l oad input characteristics at room temperature.[...]
-
Page 4
ELECTRICAL CHARACTERISTICS CUR VES Figure 4: T urn-on trans ient at full rated load current (CC mode) (5ms/div). Vin=48V .T op T rac e: V out, 2V/div; Bottom T race: ON/OFF input, 5V/div . Figure 5: T urn-on transient at zero load current (5ms/ div). Vin=48V .T op T race: Vout, 2V/div; Bottom T race: ON/OFF input, 5V/div . Figure 6: T urn-on trans [...]
-
Page 5
ELECTRICAL CHARACTERISTICS CUR VES Figure 8: Output voltage response to step-change in load current (50%-25% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF , tantalum cap acitor and 1 µF ceramic cap acitor. T op T race: Vout (100mV/div , 200us/div), Bottom T race: I out (5A/div). DS_E36SR05015_010 42008 5 Figure 9: Output voltage response to step-[...]
-
Page 6
ELECTRICAL CHARACTERISTICS CUR VES Figure 12: Input reflected ripple current, i s , through a 12µH source inductor at 48Vin and 15A output current (20 mA/ div , 2us/div). Strip Copper Vo(-) Vo(+) 10u 1u SCOPE RESISTIV E LOAD Figure 13: Output voltage noise and ripple measur ement test setup. Figure 14: Output voltage ripple at 48Vin and rated load[...]
-
Page 7
The input source must be insulated f rom the ac mains by reinforced or double insulation. The input terminals of the module are not operator accessible. If the metal baseplate is grounded , one Vi pin and one Vo pin shall also be grounded. A SELV reliability test is conducted on the system where the module is used , in combination w[...]
-
Page 8
DS_E36SR05015_010 42008 8 FEA TURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-curre nt protection circuit, which will endure current limiting for an unlimited duration during output overload. If the output current exceeds the OCP set point, the modul es will automatically shut down (hiccup mode). The modules w[...]
-
Page 9
FEA TURES DESCRIPTIONS (CON.) Output V oltage Adjustment (TRIM) To increase or decrea se the output voltage set poin t, the modules may be connected wit h an external resistor betwee n the TRIM pin and either the SENSE(+) or SENSE(-). The TRIM pin should be left open if this feature is not used. Figure 18: Circuit configuration for trim-down (decre[...]
-
Page 10
DS_E36SR05015_010 42008 10 THERMAL CONSIDERA TIONS Thermal management is an important part of the syst em design. To ensure p roper, reliable operation, sufficie nt cooling of the power mod ule is needed over the entire temperature range of the modul e. Convection coolin g is usually the dominant mode of heat transfer. Hence, the choice of equipmen[...]
-
Page 11
P I C K A N D P L A C E L O C A T I O N S U R F A C E - M O U N T T A P E & R E E L RECOMMENDED P AD LA YOUT (SMD) DS_E36SR05015_010 42008 11[...]
-
Page 12
LEADED (Sn/Pb) PROCESS RECOMMEND TEMP . PROFILE T ime ( sec. ) Pre-h eat tem p. 140~180 ° C 60~120 sec. Peak tem p. 210~230 ° C 5sec . Ramp-up te mp. 0.5~3.0 ° C /sec . T emperature ( ° C ) 50 100 150 200 250 300 60 0 120 180 240 2nd Ramp-up temp. 1.0~3.0 ° C /sec. Over 200 ° C 40~50sec. Cooling down rate <3 ° C / sec . Note: The temperat[...]
-
Page 13
MECHANICAL DRA WING Surface-mount module Through-hole module Pin No. Name Function 1 2 3 4 5 6 7 8 +Vin ON/OFF -Vin -V out -SENSE TRIM +SENSE +V out Positive input voltage Remote ON/OFF Negative input voltage Negative output voltage Negative remote sense Output voltage trim Positive remote sense Positive output voltage DS_E36SR05015_010 42008 13[...]
-
Page 14
MECHANICAL DRA WING (WITH HEA TSPREADER) THROUGH-HOLE MODULE DS_E36SR05015_010 42008 14[...]
-
Page 15
DS_E36SR05015_010 42008 15 P ART NUMBERING SYSTEM E 36 S R 050 15 N R F A T ype of Product Input V o ltage Number of Output s Product Series Output V o ltage Output Current ON/OFF Logic Pin Length/T ype Option Code E- Eighth Brick 36-18~75V S- Single R- Regular 050- 5.0V 15-15A N- Negative R- 0.170” F- RoHS 6/6 (Lead Free) A- S tandard Fu nctions[...]