Desa VF-24P-PJD,VF-24N-PJD, VF-18N-PJD, VF-18P-PJD manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 32 pages
- 1.62 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Water Heater
Desa CSG3924NR
38 pages 5.32 mb -
Water Heater
Desa CCL3924PTA
42 pages 4.95 mb -
Water Heater
Desa CFN2800BTB
32 pages 0.36 mb -
Water Heater
Desa CTB3924NT
38 pages 5.32 mb -
Water Heater
Desa VN10T
20 pages 0.25 mb -
Water Heater
Desa VN2800BTA
36 pages 0.39 mb -
Water Heater
Desa VN2000BTA
36 pages 0.39 mb -
Water Heater
Desa CGD3018N, CGD3924N, CGD3930N, CRL2718N, CCL3924N, CRL3124N, CCL3018N, CGD3924NT, CGD3018NT, CCL3924NT, CGD3930NT, CCL3018NT, CCL3930NTA
40 pages 2.67 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Desa VF-24P-PJD,VF-24N-PJD, VF-18N-PJD, VF-18P-PJD. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Desa VF-24P-PJD,VF-24N-PJD, VF-18N-PJD, VF-18P-PJD ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Desa VF-24P-PJD,VF-24N-PJD, VF-18N-PJD, VF-18P-PJD décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Desa VF-24P-PJD,VF-24N-PJD, VF-18N-PJD, VF-18P-PJD devrait contenir:
- informations sur les caractéristiques techniques du dispositif Desa VF-24P-PJD,VF-24N-PJD, VF-18N-PJD, VF-18P-PJD
- nom du fabricant et année de fabrication Desa VF-24P-PJD,VF-24N-PJD, VF-18N-PJD, VF-18P-PJD
- instructions d'utilisation, de réglage et d’entretien de l'équipement Desa VF-24P-PJD,VF-24N-PJD, VF-18N-PJD, VF-18P-PJD
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Desa VF-24P-PJD,VF-24N-PJD, VF-18N-PJD, VF-18P-PJD ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Desa VF-24P-PJD,VF-24N-PJD, VF-18N-PJD, VF-18P-PJD et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Desa en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Desa VF-24P-PJD,VF-24N-PJD, VF-18N-PJD, VF-18P-PJD, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Desa VF-24P-PJD,VF-24N-PJD, VF-18N-PJD, VF-18P-PJD, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Desa VF-24P-PJD,VF-24N-PJD, VF-18N-PJD, VF-18P-PJD. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
For more information, visit www .desatech.com W ARNING: If the information in this manual is not fol- lowed exactly , a fire or explosion may result causing property damage, personal injury or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHA T TO DO IF YOU[...]
-
Page 2
www .desatech.com 1 1 1826-04A 2 W ARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer , service agency or the gas supplier . W ARNING:[...]
-
Page 3
www .desatech.com 1 1 1826-04A 3 W ARNING: Do not allow fans to blow directly into the heater . A void any dra fts that alter bur ner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting. WAR NI N G : D o n o t p l a c e lo g s cr ap s o r l av a r oc ks o n burner . Due to hig[...]
-
Page 4
www .desatech.com 1 1 1826-04A 4 1. This ap plia nce is only for us e wi th t he type of ga s indi ca te d on the rat in g plat e. This ap pli ance is n ot conv erti ble for use wit h ot her gas es. 2. Do not place propane/LP supply tank(s) in - side any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only). 3. If you smell g[...]
-
Page 5
www .desatech.com 1 1 1826-04A 5 LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the lat - est edition of The National Fuel Gas Code ANSI Z223.1/NFP A 54 *. *A vailable from: American National Standards Institute, Inc. 1430 Broadway New Y ork, NY 10018 National Fire Protection Association, In[...]
-
Page 6
www .desatech.com 1 1 1826-04A 6 Unusually tight construction is defined as construction where: a. w all s and ceilin gs expos ed to the out - side atmosphere have a continuous wa te r vap or ret ar de r wi th a rati ng of on e perm (6 x 10 -1 1 kg per pa-sec -m 2 ) or less with op enin gs g aske ted or seal ed and b. weather stripping has been ad[...]
-
Page 7
www .desatech.com 1 1 1826-04A 7 AIR FOR COMB USTION AND VENTILA TION Continued If the actual Btu/Hr used is les s than th e maxim um Bt u/ Hr th e spa ce ca n sup port , the space is an uncon- fined space. Y ou will need no additional fresh air ventilation. W ARNING: If the area in which the heater may be oper- ated is smaller than that defined [...]
-
Page 8
www .desatech.com 1 1 1826-04A 8 INST ALLA TION NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heati ng system, you may run system’s circulating blower while using heater . This will help cir cula [...]
-
Page 9
www .desatech.com 1 1 1826-04A 9 INST ALLA TION AND CLEARANCES FOR VENT -FREE OPERA TION W ARNING: Maintain the min imu m cl ear anc es. If you ca n, pro vid e great er cle ara nce s from floo r , cei lin g and ad joi nin g wal l. INST ALLA TION Continued Carefully follow the instructions below . This will ensure safe installation into a masonry ,[...]
-
Page 10
www .desatech.com 1 1 1826-04A 10 Figure 6 - Minimum Mantel Clearances Without Using Hood Minimum Non- Combustible Material Minimum Non- Combustible Material Height Distances to Underside of Mantel T op of Fireplace Opening Underside of Mantel Shelf Mantel Shelf 12" ( A ) 18" 20" 22" 24" All minimum distances are in inches [...]
-
Page 11
www .desatech.com 1 1 1826-04A 1 1 MANTEL CLEARANCES In addition to meeting noncombustible material clea ranc es, you must also meet requir ed cleara nces between fireplace openings and mantel shelf on each side of the fireplace. If you do not meet the clearances listed below , you will need a hood. Determining Minimum Mantel Clearance If you mee[...]
-
Page 12
www .desatech.com 1 1 1826-04A 12 CONNECTING TO GAS SUPPL Y W ARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator . W ARN IN G: A q ua lifi ed se rvi ce p er so n mu s t co n n e ct h e at er t o g a s su pp ly . Fo llo w al l lo cal c od es . CAU TION: Neve r con nect propane/LP firep[...]
-
Page 13
www .desatech.com 1 1 1826-04A 13 W e recommend that you install a sediment trap in supp ly line as shown in Figu re 12. Locate sed imen t trap where it is within reach for cleaning. Install in piping system between fuel supply and heater . Locate sediment trap where trapped matter is not likel y to freeze. A sedime nt trap traps moisture and conta[...]
-
Page 14
www .desatech.com 1 1 1826-04A 14 INST ALLA TION Continued PRESSURE TESTING HEA TER GAS CONNECTIONS 1. Op en e quip men t sh ut of f v alv e (s ee F ig ure 13) . 2. Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve. 3. Make sure control knob of heate r is in the OFF position. 4. Check all joints f[...]
-
Page 15
www .desatech.com 1 1 1826-04A 15 WHA T TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • I m m e d i a t el y c a l l y o u r g a s s u p pl i e r from a neighbor ʼ s phone. Follow the gas supplierʼs instructions. • If you cannot reach your gas supplie[...]
-
Page 16
www .desatech.com 1 1 1826-04A 16 Changing The Code • The control is radio frequency operated. A code (chosen from among 4,000 available code s) i s pres et for al l va lves , bu t ca n be changed if required (15 additional codes availab le). Change DIP switch position. (The DIP switch is located inside the hand held control at the top of the bat[...]
-
Page 17
www .desatech.com 1 1 1826-04A 17 OPERA TING HEA TER Continued Set Timer • Switch to timer mode by pressing the SET button briefly . • Press the SET button until P1 flashes. • Set t he h ou rs w ith an d mi nu tes wit h . • Press SET briefly for the next burner cycle time. • If all 4 times are set, pres sing the OFF button or waiting w[...]
-
Page 18
www .desatech.com 1 1 1826-04A 18 10 . Continue holding down metal core for about 10 secon ds and then releas e the metal cor e. Pil ot shoul d stay lit. If not, rep eat step s one through 4, page 17. 1 1. T urn MAN-Knob to ON position - main gas flows. 12. T urn Motor -kno b to adj ust flam e. Knob has a slipping clutch that allows manual flame[...]
-
Page 19
www .desatech.com 1 1 1826-04A 19 CLEANING AND MAINTENANCE W ARNING: T urn off heater and let cool before cleaning. CA UT I O N : Y o u mu st ke ep co n- tr ol ar eas , bu rne r and ci rc ula tin g ai r pas sa gew ays of he ate r cle an. Inspec t these areas of heater befo re e ach u se. Have he ater in spe cte d yea rly by a qu ali fied se rvi ce[...]
-
Page 20
www .desatech.com 1 1 1826-04A 20 TROUBLESHOO TING W ARNING: T urn off heater and let cool before servicing. Only a qualified service person should service and repair heater . CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit. Note: All troubleshooting items are listed in order of operation. POS[...]
-
Page 21
www .desatech.com 1 1 1826-04A 21 TROUBLESHOO TING Continued OBSERVED PROBLEM Burner backfiring during com- bustion Orange flame in burner during burner combustion Slight smoke or odor during initial operation (first hour) Hea ter pr odu ces a w hist lin g noise when burner is lit White powder residue forming within burner box or on adjacent wal[...]
-
Page 22
www .desatech.com 1 1 1826-04A 22 TROUBLESHOO TING Continued W ARNING: If you smell gas • Shut off gas supply . • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone. Fol- low the gas supplier ’ s instructions. • [...]
-
Page 23
www .desatech.com 1 1 1826-04A 23 TROUBLESHOO TING Continued POSSIBLE CAUSE Battery nearly down. (When signal appears the first time ap - proximately 10 ignitions left) Cable is not connected, ON/OFF switch is in OFF position Ignition not successful, possible air in supplyline REMEDY Replace battery Connect cables Swit to ON. Repeat procedure OBSE[...]
-
Page 24
www .desatech.com 1 1 1826-04A 24 SERVICE HINTS When Gas Pressure Is T oo Low • pilot will not stay lit • burners will have delayed ignition • propane/LP gas supply may be low Y ou may feel your gas pressure is too low . If so, contact your local propane/LP or natural gas supplier . TECHNICAL SERVICE Y ou may ha ve furthe r q uest ion s a bou[...]
-
Page 25
www .desatech.com 1 1 1826-04A 25 VF-18N-PJD VF-24N-PJD Btu (V ariable) 21,000/30,000 21,000/39,000 T ype Gas Natural Gas Only Natural Gas Only Ignition Piezo Piezo Manifold Pressure 3.5" W .C. 3.5" W .C. Inlet Gas Pressure (in. of water) Maximum 10.5" W .C. 10.5" W .C. Minimum* 5.0" W .C. 5.0" W .C. Shipping W eight 3[...]
-
Page 26
www .desatech.com 1 1 1826-04A 26 ILL USTRA TED P ARTS BREAKDOWN MODELS VF-18N-PJD AND VF-18P-PJD 1 2 24 24 24 24 24 24 24 24 7 8 9 10 1 1 12 1 1 13 14 15 16 17 18 3 6 4 19 20 21 22 23 5[...]
-
Page 27
www .desatech.com 1 1 1826-04A 27 P ARTS LIST This list contains replaceable parts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual. KEY P ART NUMBER NO. VF-18N-PJD VF-18P-PJD DESCRIPTION QTY . 1 ** ** Chassis 1 2 1 12791-01 1 12791-01 Grate 1 3 1 16672-01 1 16672-02 PJD Rem[...]
-
Page 28
www .desatech.com 1 1 1826-04A 28 ILL USTRA TED P ARTS BREAKDOWN MODELS VF-24N-PJD AND VF-24P-PJD 1 2 3 6 4 25 25 25 25 25 25 7 8 9 10 1 1 1 1 12 13 14 15 16 17 18 19 20 21 22 23 24 5[...]
-
Page 29
www .desatech.com 1 1 1826-04A 29 P ARTS LIST This list contains replaceable parts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual. KEY P ART NUMBER NO. VF-24N-PJD VF-24P-PJD DESCRIPTION QTY . 1 ** ** Chassis 1 2 1 1 181 1-01 1 1 181 1-01 Grate 1 3 1 16672-01 1 16672-02 PJD[...]
-
Page 30
www .desatech.com 1 1 1826-04A 30 _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __________________________________________[...]
-
Page 31
www .desatech.com 1 1 1826-04A 31 _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __________________________________________[...]
-
Page 32
2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com NOT A UPC WARRANTY INFORMA TION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory . W e reserve the right to amend these specifications at any time without notice. The only warranty appli[...]