Emerson Process Management TF396 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 20 pages
- 0.45 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Stud Sensor
Emerson Process Management 37-5392D
4 pages 0.07 mb -
Stud Sensor
Emerson Process Management T-SERIES
20 pages 1.89 mb -
Stud Sensor
Emerson Process Management DVS205
4 pages 0.06 mb -
Stud Sensor
Emerson Process Management 369P
40 pages 8.15 mb -
Stud Sensor
Emerson Process Management 396PVP
40 pages 8.15 mb -
Stud Sensor
Emerson Process Management 53eA
116 pages 0.99 mb -
Stud Sensor
Emerson Process Management 00809-0100-4952 Rev BA
24 pages 0.43 mb -
Stud Sensor
Emerson Process Management 381
32 pages 0.48 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Emerson Process Management TF396. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Emerson Process Management TF396 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Emerson Process Management TF396 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Emerson Process Management TF396 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Emerson Process Management TF396
- nom du fabricant et année de fabrication Emerson Process Management TF396
- instructions d'utilisation, de réglage et d’entretien de l'équipement Emerson Process Management TF396
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Emerson Process Management TF396 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Emerson Process Management TF396 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Emerson Process Management en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Emerson Process Management TF396, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Emerson Process Management TF396, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Emerson Process Management TF396. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
COMBINA TION pH SENSOR Instruction Manual PN 51-TF396/rev .G June 2012 MODEL TF396 with mating cable Model TF396[...]
-
Page 2
CAUTION SENSOR/PROCESS APPLICA TION COMP A TIBILITY The wetted sensor materials may not be comp atible with process com position and operating conditions. Application comp at ibility is entirely the responsibility of the user . DANGER HAZARDOUS AREA INST ALLA TION This sensor is not Intrinsically Safe. or Explosion Proof. Installations near flammab[...]
-
Page 3
i MODEL TF396 T ABLE OF CONTENTS MODEL TF396 COMBINA TION pH SENSOR T ABLE OF CONTENTS Section Title Page 1.0 DESCRIPTION AND SPECIFICA TIONS ................................................................. 1 1.1 Features and Applications ........................................................................................ 1 1.2 S pecifications[...]
-
Page 4
MODEL TF396 T ABLE OF CONTENTS LIST OF FIGURES Number Title Page 2-1 Dimensional Drawing ............................................................................................... 4 2-2 Flow-Through T ee with Adapter ................................................................................ 4 2-3 Flow-Through and Insertion Installations [...]
-
Page 5
greater than typical teflon or ceramic junctions) is made of micron-sized reference pathways allowing for ionic exchange but preventing plugging by larger particles and will continue to send a steady pH signal, even in the dirtiest of applications. The field-proven TUpH reference junction tech- nology results in greatly reduced maintenance requirem[...]
-
Page 6
MODEL TF396 SECTION 1.0 DESCRIPTIONS AND SPECIFICA TIONS The Model TF396 TUpHFET Non-glass ISFET pH Sensor is housed in a molded reinforced polypropylene body with 1 in. MNPT threads suit able for insertion, submersion or flow through installation, or housed in a 316SST body for use with a 2.0 inch T ri-Clamp fitting. The sensor includes an ion-sel[...]
-
Page 7
3 MODEL TF396 SECTION 2.0 INST ALLA TION SECTION 2.0 INST ALLA TION In most cases, the pH sensor can simply be installed as shipped and readings with an accuracy of ± 0.6 pH may be obtained. T o obtain greater accuracy or to ver- ify proper operation, the sensor must be calibrated as a loop with its comp atible analyzer or transmitter . 2.2.1 Flow[...]
-
Page 8
4 MODEL TF396 SECTION 2.0 INST ALLA TION FIGURE 2-1. Dimensional Drawing DWG . NO. REV . 4TF39604 B MILLIMETER INCH FIGURE 2-2. Flow-Through T ee with Adapter (PN 915240-xx*) MILLIMETER INCH xx* Process Connection Threads 03 3/4 inch 04 1 inch 05 1-1/2 inch SENSOR CABLE WITH CONNECTOR - NOT SHOWN[...]
-
Page 9
MODEL TF396 SECTION 2.0 INST ALLA TION DWG . NO. REV . 4TF39601 A 5 FIGURE 2-4. Model TF396 with Insertion Mounting Adapter PN 23242-02 FIGURE 2-3. Flow-Through and Insertion Inst allations DWG . NO. REV . 40396P05 C[...]
-
Page 10
MODEL TF396 SECTION 2.0 INST ALLA TION FIGURE 2-5. Submersion Inst allations WHEN INCH AND METRIC DIMS ARE GIVEN MILLIMETER INCH DWG . NO. REV . 4TF39602 A DWG . NO. REV . 4TF39603 B 6 PN 23550-00 (WITHOUT PREAMP)[...]
-
Page 11
7 MODEL TF396 SECTION 2.0 INST ALLA TION FIGURE 2-7. Jet Spray Cleaner PN 12707-00 MILLIMETER INCH LOW FLOW CELL PN 24091-00 Inlet and outlet connections are stainless steel and take 1/4-inch OD tubing. Flow cell is polycarbonate with 1/4-inch FNPT fittings. WETTED MA TERIALS: BODY - ACRYLIC NUT - CPVC FITTINGS - 316 SST SEALS - BUNA N FLOW CELL RA[...]
-
Page 12
8 Wiring. The Model TF396 has a mating cable with built-in preamplifier and is offered with a shielded cable. The cable should be handled carefully and kept dry and free of corrosive chemicals at all times. Extreme care should be used to prevent it from being twisted, damaged or scraped by rough, sharp edges or surfaces. Please refer to Figures 3-1[...]
-
Page 13
9 MODEL TF396 SECTION 3.0 WIRING - MODEL TF396 FIGURE 3-1. Wiring to Model 1055. DWG . NO. REV . 14055103 B DWG . NO. REV . 41055102 B[...]
-
Page 14
10 MODEL TF396 SECTION 3.0 WIRING - MODEL TF396 FIGURE 3-2. Wiring to Model 54e. DWG . NO. REV . 40054E04 A FIGURE 3-2. Wiring to Models 3081, 4081, & 5081. DWG . NO. REV . 40508114 A[...]
-
Page 15
Recommended pH Sensor St andardization: For maximum accuracy , the sensor can be standardized online or with a process grab sample after a buf fer calibra- tion has been performed and the sensor has been condi- tioned to the process. S t andardization account s for the sensor junction potential and other interferences. S t andardization will not ch[...]
-
Page 16
12 MODEL TF396 SECTION 5.0 MAINTENANCE The Model TF396 Sensors require minimum mainte- nance. The sensor should be kept clean and free of debris and sediment at all times. The frequency of cleaning by wiping or brushing with a soft cloth or brush is determined by the nature of the solution being measured. The sensor should be removed from the proce[...]
-
Page 17
13 MODEL TF396 SECTION 6.0 RETURN OF MA TERIAL SECTION 6.0 RETURN OF MA TERIAL 6.1 GENERAL. T o expedite the repair and return of instruments, prop- er communication between the customer and the fac- tory is important. Before returning a product for repair , call 1-949-757-8500 for a Return Materials Authorization (RMA) number . 6.2 W ARRANTY REP A[...]
-
Page 18
FROM: RETURN BILL T O: _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ CUSTOMER/USER MUST SUBMIT MA TERIAL SAFETY SHEET (MSDS) O[...]
-
Page 19
W ARRANTY Seller warrants that the firmware will execute the programming instructions provided by Seller , and that the Goods manufactured or Services provided by Seller will be free from defects in materials or workmanship under normal use and care until the expira- tion of the applicable warranty period. Goods are warranted for twelve (12) months[...]
-
Page 20
Credit Cards for U.S. Purchases Only . The right people, the right answers, right now . ON-LINE ORDERING NOW A V AILABLE ON OUR WEB SITE http://www .rosemountanalytical.com Specifications subject to change without notice. 8 Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA T el: (949) 757-8500 Fax: (949) 474-7250 http://www .ros[...]