First Alert First Alert Professional Security System manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 44 pages
- 0.22 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Home Security System
First Alert fire and burglary partitioned security systems with scheduleing
80 pages 0.46 mb -
Home Security System
First Alert FA210RF
1 pages 0.03 mb -
Home Security System
First Alert DWB-700
12 pages 0.34 mb -
Home Security System
First Alert cm420
5 pages 1.15 mb -
Home Security System
First Alert P-500
12 pages 0.22 mb -
Home Security System
First Alert FA148CP
56 pages 0.57 mb -
Home Security System
First Alert FAI34OC
70 pages 3.11 mb -
Home Security System
First Alert SMOKE AND FIRE ALARM
7 pages 0.24 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation First Alert First Alert Professional Security System. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel First Alert First Alert Professional Security System ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation First Alert First Alert Professional Security System décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation First Alert First Alert Professional Security System devrait contenir:
- informations sur les caractéristiques techniques du dispositif First Alert First Alert Professional Security System
- nom du fabricant et année de fabrication First Alert First Alert Professional Security System
- instructions d'utilisation, de réglage et d’entretien de l'équipement First Alert First Alert Professional Security System
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage First Alert First Alert Professional Security System ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles First Alert First Alert Professional Security System et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service First Alert en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées First Alert First Alert Professional Security System, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif First Alert First Alert Professional Security System, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation First Alert First Alert Professional Security System. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
USER'S MANUAL FA142C Security System N7229–1V2 Rev B 4/99 Previous Menu[...]
-
Page 2
–2– TABLE OF CONTENTS SYSTEM OVERVIEW ...................................................................................... 3 General.......................................................................................................... 3 Keypads................................................................................................[...]
-
Page 3
–3– SYSTEM OVERVIEW General Congratulations on your ownership of a First Alert Professional Security System. You've made a wise decision in choosing it, for it represents the latest in security protection technology today, including microcomputer technology to monitor all system status. Basically, this system offers you three forms of prot[...]
-
Page 4
–4– SYSTEM OVERVIEW Fire Protection The fire protection portion of your security system (if used) is always on and will sound an alarm if a fire condition is detected. Refer to the FIRE ALARM SYSTEM section for important information concerning fire protection, smoke detectors and planning emer- gency exit routes from your house. Alarms When an [...]
-
Page 5
–5– ABOUT THE KEYPADS General Your keypad(s) (see page 7) allow you to control all system functions. The keypads feature a telephone style (digital) keypad and a Liquid Crystal Display (LCD) which shows the nature and location of all occurrences. The keypads feature a built-in sounder which emits alarm sounds during alarm conditions and produce[...]
-
Page 6
–6– ABOUT THE KEYPADS Fixed-Word Keypad Displays AWAY All burglary zones, interior & perimeter, are armed. STAY Perimeter burglary zones, such as windows and doors are armed. INSTANT Perimeter burglary zones armed and entry delay is turned off. BYPASS One or more burglary protection zones have been bypassed. NOT READY Appears when burglary [...]
-
Page 7
–7– ABOUT THE KEYPADS KEYPADS WITH FLIP-DOWN KEY COVERS ARE SHOWN WITH COVER REMOVED ARMED READY Professional OFF AWAY STAY MAXIMUM TEST BYPASS INSTANT CODE CHIME READY 1 A B C D 2 3 4 5 6 7 8 9 * 0# First Alert First Alert ® READY Professional OFF AW A Y STA Y MAXIMUM TEST BYP ASS INST ANT CODE CHIME READY P ANIC 1 2 3 4 5 6 7 8 9 * 0 # ARMED[...]
-
Page 8
–8– FUNCTIONS OF THE KEYPAD SEE TYPICAL ALPHA KEYPAD ON NEXT PAGE 1. DISPLAY WINDOW. Alpha Keypad: A 2-line, 32- character Liquid Crystal Display (LCD). Displays protection zone identification, system status, and messages (see page 9). Fixed-Word Keypad: Displays protection zone ID and system status messages using pre-designated words (see page[...]
-
Page 9
– 9 – † Note: Keys 1 through 9 each perform their associated companion functions (OFF, AWAY, STAY, etc.) when preceded by an entry of the security code (as described later). IMPORTANT! : When entering codes and commands, se- quential key depressions must be made within 2 seconds of one another. If 2 seconds elapses without a key depression, t[...]
-
Page 10
–10– SECURITY CODES General At the time of installation, your installer programmed a personal four-digit Master code, known only to you and yours. This code is used to perform most system functions, including arming and disarming of the system. As an additional safety feature, up to 4 temporary User Codes can be assigned for use by those not ha[...]
-
Page 11
–11– SECURITY CODES (Continued) Duress Code (Continued) If a DURESS code is assigned, check here: - The Duress code may be any 4-digit code assigned to User Number 8. To program a Duress code: Enter your Master Code + 8 + 8 + [desired 4-digit duress code]. The keypad will beep once. Note: The Duress code must differ from the Master Code or any [...]
-
Page 12
–12– ENTRY/EXIT DELAYS General Information Your system has preset time delays, known as exit delay and entry delay. When you arm your system, exit delay gives you time to leave through the entry/exit door without setting off an alarm. Entry delay gives you time to disarm the system when you reenter through the entry/exit door. The system must b[...]
-
Page 13
–13– CHECKING FOR OPEN ZONES Using the ✱ READY Key Before arming your system, all protected doors, windows and other protection zones must be closed or bypassed (see BYPASSING PROTECTION ZONES section), otherwise the keypad will display a "Not Ready" message, and your keypad’s READY indicator light will not be lit. The READY ( ✱[...]
-
Page 14
–14– BYPASSING PROTECTION ZONES Using the 6 BYPASS Key LIMITATION The system will not allow fire zones to be bypassed. All bypasses are removed when an OFF sequence (security code plus OFF) is performed. This key is used when you want to arm your system with one or more zones intentionally unprotected. The system must be disarmed first. 1 . Ent[...]
-
Page 15
–15– BYPASSING PROTECTION ZONES (Continued) Quick Bypass Ask your installer if "Quick Bypass" is active for your system, and determine which box(es) you should check here. → If your system supports "Quick Bypass", it allows you to easily bypass zones as checked below, without having to enter zone numbers individually. This[...]
-
Page 16
–16– ARMING PERIMETER ONLY WITH ENTRY DELAY ON Using the 3 STAY Key BEFORE ARMING, make sure all doors and windows are closed. Refer to CHECKING FOR OPEN ZONES on page 13. Use this key when staying inside, but expect someone to use an entry/exit door later. 1 . Enter your security code and press the STAY key. 2 . The keypad beeps three times an[...]
-
Page 17
–17– ARMING PERIMETER ONLY WITH ENTRY DELAY OFF Using the 7 INSTANT Key BEFORE ARMING, make sure all doors and windows are closed. Refer to CHECKING FOR OPEN ZONES on page 13. THE INSTANT MODE ARMS THE PERIMETER (INCLUDING THE ENTRY/ EXIT DOOR), WITH NO ENTRY DELAY. PERSONS WITHIN THE PREMISES CAN MOVE ABOUT FREELY Use this key when staying ins[...]
-
Page 18
–18– ARMING ALL PROTECTION WITH ENTRY DELAY ON Using the 2 AWAY Key BEFORE ARMING, make sure all doors and windows are closed. Refer to CHECKING FOR OPEN ZONES on page 13. Use this key when no one will be staying inside. 1 . Enter your security code and press the AWAY key. 2 . The keypad beeps twice and displays the armed message. The red ARMED[...]
-
Page 19
–19– ARMING ALL PROTECTION WITH ENTRY DELAY OFF Using the 4 MAXIMUM Key BEFORE ARMING, close all doors and windows (see CHECKING FOR OPEN ZONES on page 13) U se this key when the premises will be vacant for extended periods of time such as vacations, etc., or when retiring for the night and no one will be moving through protected interior areas[...]
-
Page 20
–20– DISARMING THE SYSTEM AND SILENCING ALARMS Using the 1 OFF Key IMPORTANT: If you return and the main burglary sounder is on, DO NOT ENTER, but CONTACT THE POLICE from a nearby safe location. If you return after an alarm has occurred and the main sounder has shut itself off, the keypad will beep rapidly upon your entering, indicating that an[...]
-
Page 21
–21– EXIT ALARMS Exit Alarm Warning Displays and Sounds Ask your installer if "Exit Alarm Warning" is active for your system, and if so, check here: Your system may support and have been programmed for this feature. When arming, if an exit or interior zone contains a fault during closing at the time the exit delay ends , the alarm sou[...]
-
Page 22
–22– PANIC KEYS (FOR MANUALLY ACTIVATING SILENT AND/OR AUDIBLE ALARMS) Using Panic Keys Your system may have been programmed to use special keys or combinations of keys to manually activate emergency (panic) functions. The functions that might be programmed are: Silent Emergency, Audible Emergency, Personal Emergency, and Fire. A silent emergen[...]
-
Page 23
–23– PANIC KEYS CHECK IF PANIC P R O G R A M M E D ZONE ACTIVE KEY(S) F U N C T I O N NUMBER [A] ____SILENT, ____AUDIBLE, ____PERSONAL, ____FIRE 9 5 [B] ____SILENT, ____AUDIBLE, ____PERSONAL, ____FIRE 0 7 SEE YOUR INSTALLER [C] ____SILENT, ____AUDIBLE, ____PERSONAL, ____FIRE 9 6 AND NOTE HERE OR THE KEY(S) & FUNCTION(S) [1] & [ ✴ ] __[...]
-
Page 24
–24– TESTING THE SYSTEM TO BE CONDUCTED WEEKLY Using the 5 TEST Key NO ALARM REPORTS WILL BE SENT TO THE CENTRAL MONITORING STATION while the system is in Test mode. The TEST key puts your system into Test mode, which allows each protection point to be checked for proper operation. 1 . Disarm the system and close all protected windows, doors, e[...]
-
Page 25
–25– TESTING THE SYSTEM (Continued) 7 . After all protection points have been checked and restored, there should be no zone identification numbers displayed. If a problem is experienced with any protection point (no confirming sounds, no display), CALL FOR SERVICE IMMEDIATELY. 8 . Turn off the Test mode by entering the security code and pressin[...]
-
Page 26
–26– TROUBLE CONDITIONS "Check" and "Battery" Displays * Not all systems use wireless sensors. T he word CHECK on the keypad's display, accompanied by a "beeping" at the keypad, indicates a trouble condition in the system. To silence the beeping for these conditions, press any key. 1. A display of "CHECK&[...]
-
Page 27
– 27 – TROUBLE CONDITIONS Words or letters in parentheses ( ) are those that are displayed on Fixed-word keypads. [ Other Trouble Displays * Any “beeping” that accompanies a trouble display can be stopped by entering an OFF sequence (code + OFF) ** Not all systems use wireless transmitters. 1. COMM. FAILURE Indicates that a failure has occu[...]
-
Page 28
– 28 – TROUBLE CONDITIONS Other Trouble Displays (Continued) 5. AC LOSS is displayed The system is operating on battery power only due to a (or NO AC ) power failure. If only some lights are out on the premises, check circuit breakers and fuses and reset or replace as necessary. CALL FOR SERVICE if AC power cannot be restored to the system. 6. [...]
-
Page 29
–29– FIRE ALARM SYSTEM (IF INSTALLED) General Your fire alarm system (if installed) is on 24 hours a day, for continuous protection. In the event of an emergency, the strategically located smoke and heat detectors will au- tomatically send signals to your system, triggering a loud, interrupted pulsed sound* from the Keypad(s). This sound will a[...]
-
Page 30
–30– FIRE ALARM SYSTEM (Continued) Manually Initiating a Fire Alarm 1 . Should you become aware of a fire emergency before your detectors sense the problem, go to your nearest Keypad and manually initiate an alarm by pressing the appropriate panic key(s), assigned for FIRE emergency (if programmed by the installer). Check below, and on page 23.[...]
-
Page 31
–31– NATIONAL FIRE PROTECTION ASSOCIATION RECOMMENDATIONS ON SMOKE DETECTORS DINING KITCHEN BEDROOM BEDROOM BEDROOM BEDROOM LIVING ROOM ✪ ✪ ✪ ✪ ✪ ▲ ▲ BEDROOM BDRM BDRM DINING LIVING ROOM TV ROOM KITCHEN ■ ■ ■ ✪ ✪ ✪ ✪✪ ✪ ▲ ✪ ✪ ✪ BEDROOM BEDROOM TO BR ■ ■ ■ ■ ■ LVNG RM BASEMENT KTCHN ▲ ▲ . CLO[...]
-
Page 32
–32– EMERGENCY EVACUATION Steps to Safety • FRONT • BACK • BEDROOM BA TH BEDROOM KITCHEN BACK DOOR 1 FLOOR ST BEDROOM BEDROOM 2 FLOOR ND BA TH BEDROOM PORCH CLOSET Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the National Fire Protection Association: 1 . Plan on your detect[...]
-
Page 33
–33– QUICK GUIDE TO ALARM SYSTEM FUNCTIONS FUNCTION PROCEDURE COMMENTS Check Zones Press READY key. To view faulted zones when system not ready. Arm System Enter code. Press arming key desired: (AWAY, STAY, INSTANT, MAXIMUM) Arms system in mode selected. Quick Arm (if programmed) Press #. Press arming key desired: (AWAY, STAY, INSTANT, MAXIMUM)[...]
-
Page 34
–34– SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS (ALPHA DISPLAY KEYPADS) SOUND CAUSE DISPLAY LOUD, INTERRUPTED* Keypad & External FIRE ALARM FIRE is displayed; descriptor of zone in alarm is displayed. LOUD, CONTINUOUS* Keypad & External BURGLARY/AUDIBLE EMERGENCY ALARM ALARM is displayed; descriptor of zone in alarm is also displayed.. Als[...]
-
Page 35
–35– SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS (FIXED-WORD DISPLAY KEYPADS) SOUND CAUSE DISPLAY LOUD, INTERRUPTED* Keypad & External FIRE ALARM FIRE and ALARM are displayed; protection zone in alarm is displayed. LOUD, CONTINUOUS* Keypad & External BURGLARY/AUDIBLE EMERGENCY ALARM ALARM is displayed; protection zone in alarm is also displ[...]
-
Page 36
–36– PROTECTION ZONES LIST One or more sensing devices will have been assigned by the installer of your alarm system to each of the various protection zones in your system (although not every zone number can be used). For example, the sensing device on your Entry/Exit door may have been assigned to zone 06, sensing devices on windows in the mas[...]
-
Page 37
–37– OWNER'S INSURANCE PREMIUM CREDIT REQUEST This form should be completed and forwarded to your homeowner's insurance carrier for possible premium credit. A . GENERAL INFORMATION: Insured's Name and Address: ____________________________________________________________________________ ____________________________________________[...]
-
Page 38
–38– OWNER'S INSURANCE PREMIUM CREDIT REQUEST (cont.) E . SMOKE DETECTOR LOCATIONS: Furnace Room Kitchen Bedrooms Attic Basement Living Room Dining Room Hall F . BURGLARY DETECTING DEVICE LOCATIONS: Front Door Basement Door Rear Door All Exterior Doors 1st Floor Windows All windows Interior Locations All Accessible Openings, Including Skyl[...]
-
Page 39
–39– CANADIAN DEPARTMENT OF COMMUNICATIONS (DOC) STATEMENT NOTICE The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to th[...]
-
Page 40
–40– UL NOTICE: This is a "Grade A" Residential System. FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statem ent for your information: This equipment generates and uses radio frequency energy and if not [...]
-
Page 41
–41– FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 STATEMENT This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains, among oth er information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the [...]
-
Page 42
–42– WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or ot her emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons. For example: • Intruders ma[...]
-
Page 43
–43– (continued) WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM • Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the other side of closed or partly open doors. If warning devices sound on a different level of the residence from the bedrooms, then they are less likely to wake[...]
-
Page 44
àN7229-1V2"ä N7229–1V2 Rev B 4/99 ONE YEAR LIMITED WARRANTY Pittway Corporation, and its divisions, subsidiaries and affiliates ("Seller"), 165 Eileen Way, Syosset, New York 11791, warran ts its First Alert Professional security equipment (the "product") to be free from defects in materials and workmanship for one year [...]