Friedrich SH20L50-A manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 20 pages
- 0.3 mb
Aller à la page of
Les manuels d’utilisation similaires
- 
									
                                        Air ConditionerFriedrich R410A7 pages 0.64 mb
- 
									
                                        Air ConditionerFriedrich WS14B10A6 pages 0.92 mb
- 
									
                                        Air ConditionerFriedrich WS08B10A-C30 pages 0.83 mb
- 
									
                                        Air ConditionerFriedrich ZQ08B1028 pages 1.61 mb
- 
									
                                        Air ConditionerFriedrich MW09Y3H18 pages 1.59 mb
- 
									
                                        Air ConditionerFriedrich P/N9359944072-0120 pages 0.56 mb
- 
									
                                        Air ConditionerFriedrich MR12C1F46 pages 0.62 mb
- 
									
                                        Air ConditionerFriedrich P12B12 pages 2.01 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Friedrich SH20L50-A. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Friedrich SH20L50-A ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Friedrich SH20L50-A décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Friedrich SH20L50-A devrait contenir: 
							 - informations sur les caractéristiques techniques du dispositif Friedrich SH20L50-A 
							 - nom du fabricant et année de fabrication Friedrich SH20L50-A 
							 - instructions d'utilisation, de réglage et d’entretien de l'équipement Friedrich SH20L50-A 
							 - signes de sécurité et attestations confirmant la conformité avec les normes pertinentes  
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Friedrich SH20L50-A ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Friedrich SH20L50-A et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Friedrich en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Friedrich SH20L50-A, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Friedrich SH20L50-A,  l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Friedrich SH20L50-A. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
- 
                            Page 1SH15L30-A SH20L30-A SH20L50-A HG-SVC-PRTS-05 (4-05) Ser vic e & P ar ts Manual R oom Air Conditioners 50 & 60 Hz M ode ls 20 05[...] 
- 
                            Page 22 TA B L E O F C O N T E N T S Specifi cations ............................................................................................................... .................... 3 Performance Data ............................................................................................................. ............... 3 Component Operation &a[...] 
- 
                            Page 33 EV APORA TOR AIR TEMP . DEG. F EV APORA TOR TEMP . DEG. F CONDENSER TEMP . DEG. F Discharge Te m p Suction Te m p Liquid Te m p Super Heat Sub- Cooling OPERA TING PRESSURES ELECTRICAL RA TINGS R-22 REF . Evap CFM Motor RPM BREAKER FUSE Discharge Air Te m p . Drop F . E(in) E(out) Suction Discharge Amps Cool Amps Heat Locked Rotor Amps Charge in O[...] 
- 
                            Page 44 COMPRESSOR WINDING TEST (Figure 2.) Remov e the co mpressor ter minal box cover and disconnect the wires from the ter minals. Using an ohmmet er , check c ontinuity across the following: COMPONENT OPERA TION AND TESTING COMPRESSORS Com pr ess ors ar e s ing le p has e , 2 08 /230 v ol t. Al l compressor motors are per manent spl it capacitor t yp[...] 
- 
                            Page 55 F AN MOTOR (Figure 4) A 230 volt single phase permanent spl it capacitor motor is used to dr ive the evaporator blower and c ondens er fan. A running capacitor is wired a cross the star t and run terminals of the motor . The motor is t otally enclosed and is prot ected with a line voltage ov erload loc ated int ernally of the motor . The motor s [...] 
- 
                            Page 66 RED DOT RUN CAP ACITOR FA N MOTOR COMPRESSOR FIGURE 7 RUN CAP ACITOR HOOK–UP CAP ACITOR, RUN A run capacitor is wired across the auxiliar y and main winding of a single ph ase permanent split capacitor motor s uch as the compressor and fan motors. A s ingle capacitor can be used for each moto r or a dual rat ed capacitor can be used for both . [...] 
- 
                            Page 77 Note: The t emperature mu st be within the range li sted to check the th ermostat. Ref er to the trou bleshooti ng section in this manual for additional in formation on ther most at te sting. TEST Remo ve the wires from the th ermostat. T urn the thermostat to its coldest position. Check to see if there is continuity bet ween the t wo terminals. [...] 
- 
                            Page 88 LOW AMBIENT BYP ASS V AL VE (Figure 9) T h e H a z a r d G a r d u n i t i s d e s i g n e d t o o p e r a t e a t l o w outside ambient temperatures. This is acc omplished by the use of a b y pass valv e installed in the refr igeration circuit. The v alve is connected be t ween the discha rge line at the compressor and the su ction proc ess tube[...] 
- 
                            Page 99 NOTE: This procedur e can be sped up by the use of heat lam ps, or by brea king the vacuum with refrigerant or dr y nitrogen at 5,00 0 microns. Pressure s ystem to 5 PSIG an d leav e in the sys- tem a minimum o f 1 0 minutes. R ecover refriger - ant, an d proceed with evacu ation to a pressu re of 200 mic rons or a minimum of 1 0 % . 1 1 . Break [...] 
- 
                            Page 1010 NOTE: All inoperative compressors returned to Friedrich must have all lines properly plugged with the plugs from the replacement compressor . REFRIGERANT CHARGE 1 . The refrigerant charge is e xtremely c ritic al. Measure the charge carefully an d as e xactly as possible t o the namepl ate ch arge. 2. The cor rect method for chargi ng the rotar [...] 
- 
                            Page 1111 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE TO CORRECT UNI T DOES N OT RUN. Power disconnected. Check power sourc e. System switch in “O f f ” position. Se t switch co rrec tly . Branch c ircuit fuse blown or circuit breaker tripped. Replace fuse, reset break er . If repeats, check f use or breaker siz e. Check for shor ts in unit w iring and com[...] 
- 
                            Page 1212 TROUBLESHOOTING (Co ntinu ed ) PROBLEM POSSIBLE CAUSE T O CORRECT COM PRESSO R AT T E M P T S T O ST ART , O R RUNS FO R S H O R T PERIOD S ONL Y . C Y CLES ON OV ER LOA D. Compress or attempts to st ar t before system pressures are equal ized . Allow a minimum of t wo ( 2) minutes to allow pressures to equalize before attempting to st ar t. Low[...] 
- 
                            Page 1313 TROUBLESHOOTING (Co ntinu ed ) PROBLEM POSSIBLE CAUSE T O CORRECT FA N M O T O R D O E S NOT R UN. Defective switch (O n- Of f ) . Check c ontinuit y across ter minals 2 and 3. Fan c a p a c i t o r o p e n . Check by substituting a known good c apac itor of the same rating . Inoperative fan motor . Direct test fan motor . Incor rec t wiring of [...] 
- 
                            Page 1414 WIRING D IA GR AM MODELS SH 1 5L3 0 - A , SH20 L30 - A , SH20L5 0 - A[...] 
- 
                            Page 1515 HAZARDGARD CABINET P ARTS[...] 
- 
                            Page 1616 HAZARDGARD CHASSIS P ARTS[...] 
- 
                            Page 1717 HAZARDGARD P ARTS LIST REF DESCRIPTION P ART NO# MODELS CODE ELECTRICAL P ARTS SH15L30-A SH20L30-A SH20L50-A 1 COMPRESSOR 61 193549 1 600 1 COMPRESSOR 61 193550 1 600 1 COMPRESSOR 61 193565 1 600 2 MOTOR, F AN 61871426 11 1 0 2 MOTOR, F AN 61871427 11 1 0 2 MOTOR, F AN 61871450 11 1 0 5 SWITCH, ON-OFF DPST 60935300 1 1 1 130 * INSULA TOR, ELECTR[...] 
- 
                            Page 1818 REF DESCRIPTION P ART NO# MODELS CODE CHASSIS P ARTS SH15L30-A SH20L30-A SH20L50-A 26 SHROUD, CONDENSER 61803601 17 2 0 26 SHROUD, CONDENSER 61804901 11 7 2 0 27 BRACE, COND.SHROUD 61802600 33 3 7 2 2 22 F AN BLADE, COND. 60542003 17 1 0 22 F AN BLADE, COND. 60542004 11 7 1 0 23 BLOWER WHEEL, EV AP . 60610616 17 0 0 23 BLOWER WHEEL, EV AP . 6061[...] 
- 
                            Page 1919[...] 
- 
                            Page 20HG-SVC-PRTS-05 (4-05) Use Factory Certifi ed Parts. FRIEDRICH AIR CONDITIONING CO. P ost Office Box 1540 · San Antonio, T exas 78295-1540 4200 N. P an Am Expressway · San Antonio, T exas 78218-5212 (210) 357-4400 · F AX (210) 357-4480 www .friedrich.com Printed in the U.S.A.[...] 

