Aller à la page of
Les manuels d’utilisation similaires
-
Air Conditioner
Goodman Mfg Condensing Units
21 pages 0.44 mb -
Air Conditioner
Goodman Mfg SS-CPKF50
16 pages 0.52 mb -
Air Conditioner
Goodman Mfg GPH14H
4 pages 0.42 mb -
Air Conditioner
Goodman Mfg Self-Contained Packaged Air Conditioner with R-410A
12 pages 0.74 mb -
Air Conditioner
Goodman Mfg Air Conditioning and Heat Pump Packaged Units
4 pages 0.42 mb -
Air Conditioner
Goodman Mfg 15-TON COMMERCIAL PKG AC
40 pages 0.93 mb -
Air Conditioner
Goodman Mfg GSX130181E
44 pages 0.7 mb -
Air Conditioner
Goodman Mfg ARPT
13 pages 0.3 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Goodman Mfg IO-402G. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Goodman Mfg IO-402G ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Goodman Mfg IO-402G décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Goodman Mfg IO-402G devrait contenir:
- informations sur les caractéristiques techniques du dispositif Goodman Mfg IO-402G
- nom du fabricant et année de fabrication Goodman Mfg IO-402G
- instructions d'utilisation, de réglage et d’entretien de l'équipement Goodman Mfg IO-402G
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Goodman Mfg IO-402G ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Goodman Mfg IO-402G et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Goodman Mfg en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Goodman Mfg IO-402G, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Goodman Mfg IO-402G, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Goodman Mfg IO-402G. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
CONDENSING AC UNIT SINGLE / THREE PHASE AIR CONDITIONERS INSTALLATION & SERVICE REFERENCE © 2010-2012 Goodman Manufacturing Company, L.P. 5151 San Felipe, Suite 500, Houston, TX 77056 www.goodmanmfg.com -or- www.amana-hac.com P/N: IO-402G Date: May 2012 See unit rating plate for initial charge. Important Safety Instructions The following symbo[...]
-
Page 2
2 Installation Clearances Special consideration must be given to location of the con- densing unit(s) in regard to structures, obstructions, other units, and any/all other factors that may interfere with air circulation. Where possible, the top of the unit should be completely unob- structed; however, if vertical conditions require placement be- ne[...]
-
Page 3
3 Use only refrigerant grade (dehydrated and sealed) copper tub- ing to connect the condensing unit with the indoor evaporator. After cutting the tubing, install plugs to keep refrigerant tubing clean and dry prior to and during installation. Tubing should always be cut square keeping ends round and free from burrs. Clean the tubing to prevent cont[...]
-
Page 4
4 Refrigerant Line Connections NOTICE THIS UNIT IS SHI PPED WITH A NITROG EN/HELIUM HOLDING CH ARGE O NL Y . UNI T MU ST BE EV ACUA TED AND CHARGED PER INST ALLA TION INSTRUCTIONS WITH REFRIGERANT LISTED O N SERIAL RA TING PLA TE. NOTICE UNITS SHI PPED WITH A HOLDING CHARGE ARE INTENDED FOR COMPON ENT REPLACEM ENT ONL Y ON EXISTING SYSTEMS, AND NOT[...]
-
Page 5
5 NOTICE THIS UNIT IS SHI PPED WITH A NITROG EN/HELIUM HOLDING CH ARGE O NL Y . UNI T MU ST BE EV ACUA TED AND CHARGED PER INST ALLA TION INSTRUCTIONS WITH REFRIGERANT LISTED O N SERIAL RA TING PLA TE. NOTICE UNITS SHI PPED WITH A HOLDING CHARGE ARE INTENDED FOR COMPON ENT REPLACEM ENT ONL Y ON EXISTING SYSTEMS, AND NOT I NTENDED FOR USE I N NEW SY[...]
-
Page 6
6 Local codes often require a disconnect switch located near the unit; do not install the switch on the unit. Refer to the installa- tion instructions supplied with the indoor furnace/air handler for specific wiring connections and indoor unit configuration. Like- wise, consult the instructions packaged with the thermostat for mounting and location[...]
-
Page 7
7 Charge V erification REFRIGERANT UNDER PRES SUR E! • Do not over charg e sy stem w ith refr iger ant. • Do not opera te uni t i n a va cuu m or a t ne gative p res- sure. Fa il ure t o fol l o w pro per proc e dur es ma y ca use pr ope rty da m ag e , pe r sona l i nj ur y or de a t h. WARN ING Us e refr ige ra nt cert i fied stan da r ds . U[...]
-
Page 8
8 L I Q UI D PR E SSU R E S ATU RATED LIQUI D T E M P ER A T U R E º F P SIG R - 2 2 20 0 1 0 1 21 0 1 0 5 22 0 1 0 8 22 5 1 1 0 23 5 1 1 3 24 5 1 1 6 25 5 1 1 9 26 5 1 2 1 27 5 1 2 4 28 5 1 2 7 29 5 1 3 0 30 5 1 3 3 32 5 1 3 7 35 5 1 4 4 37 5 1 4 8 40 5 1 5 5 41 5 1 5 7 42 5 n /a 43 5 n /a 44 5 n /a 47 5 n /a 50 0 n /a 52 5 n /a 55 0 n /a 57 5 n [...]
-
Page 9
9 Fixed Orifice CAUTION T o pre ven t pe rsona l injury , carefully c onn ect a nd disconne ct manifold ga uge ho ses. Es capin g liqu id re frigerant can ca use burns. Do no t ven t refrige rant into the atm osph ere. Re cove r all refrigerant during sy stem rep air a nd befor e final un it disp osal. 1. Purge gauge lines. Connect service gauge ma[...]
-
Page 10
10 T roubleshooting Information For detailed service information refer to the Remote Condensing Unit Service manual. Complaint Unsatisfact ory Cooling POSSIB LE CAUSE DOT S IN ANA LYSIS GUIDE INDICATE "POSSIBLE CAUSE" SYMPTOM System wi ll not sta rt Compressor will not start - fan runs Compres sor and Conden ser F an will not s tart Evapo[...]
-
Page 11
11 THIS PAGE INTENTIONALL Y LEFT BLANK[...]
-
Page 12
12 SPLIT SYSTEMS AIR CONDITIONING AND HEA T PUMP HOMEOWNER’S ROUTINE MAINTENANCE RECOMMENDA TIONS We strongly recommend a bi-annual maintenance checkup be performed before the heating and cooling seasons begin by a qualified servicer . R EPLACE OR C LEAN F IL TER IMPORTANT NOTE: Never operate unit without a filter installed as dust and lint will [...]
-
Page 13
Important Safety Instructions The following symbols and labels are used throughout this manual to indicate immediate or potential safety hazards. It is the owner’s and installer’s responsibility to read and comply with all safety information and instructions accompanying these symbols. Failure to heed safety information increases the risk of pe[...]
-
Page 14
2 Use field-supplied spreader bars when lifting the unit to mini- mize the possibility of lifting cable/straps damage. To protect the cabinet louvers, use protective material such as plywood behind the cable/straps. Arrange the straps to form a central suspension point. NOTE: When raising and setting the unit, observe all safety rules. Remove shipp[...]
-
Page 15
3 To a void po s sib le ex plo si on, use on ly ret u rna bl e ( n ot disp osable) serv ice cyli nders w hen r emovi ng r ef rig- erant fro m a s y stem. • Ensure th e cyli nd er is free of dama ge which coul d l e ad t o a lea k o r e xplos i on . • Ensure the hy drostat ic test date do es not excee d 5 years. • Ensure t he pr essu re rat in[...]
-
Page 16
4 Refrigerant Line Connections NOTI CE THIS UN IT IS SHIP P ED WIT H A NITROGEN /H E LIU M HOL DING CHAR GE ONL Y . UNIT MUS T BE EVAC UATED AN D CHA RG ED P ER I NS T AL LA TIO N INSTR U CTIONS WIT H R EFRIG ERA NT L ISTED ON SERIAL RATING PLATE. NOTE: Holding charge must be removed before brazing. Open service valves slowly to remove holding char[...]
-
Page 17
5 5000 4500 4000 3500 3000 2500 2000 1500 1000 500 0 1 2 3 4 5 6 7 8 9 10 LEA K(S) PRESENT MINU T E S V ACUUM IN M IC RON S CONDENSIBLES OR SMALL LEAK PR ESENT NO LEA KS NO CO NDENSIBLES • If the pressure rises to 1000 microns or less and remains steady the system is considered leak-free; proceed to startup. • If pressure rises above 1000 micro[...]
-
Page 18
6 Example: A 7 ½ T on unit i s t o be i nstal led. The dist ance fr om the building to the u nit is 75’. Ca lculate the m inimum wire size assuming no mor e than 2% volt age d rop . MCA for 7 T on 230V unit = 43.3 (f rom S&R pl ate ). Applyi ng previous tab le wi re s izes less t han #8 A WG canno t be us ed for ci rcui t s wh ic h h ave a r[...]
-
Page 19
7 For the 7-1/2 ton unit starting charge should be 15 lb of R-22 and 18 lbs for the 10 ton unit. The length of line set, indoor unit airflow, condensing unit location and number of tubing fittings will have an impact on final unit charge amount. Turn the elec- trical power on, and let the system run. Wait for the refrigerant pressures to stabilize.[...]
-
Page 20
8 TROUBLESHOOTING ANAL YSIS T ABLE CO M P LAIN T PR O BA BL E CA USE RE M ED Y 1 . E x c essi v e c harge o f r efr i ger ant i n s y stem . 1 . Purge o r pump- do wn ex c ess i v e c harge. 2 . Inadeq uate s up pl y of ai r acros s the 2. M a k e ce r tai n that c o i l i s no t foul ed i n any c onde ns er c oi l. way , or that ai r i s no t r e-[...]