Goodman Mfg MSC/MSH 9 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 12 pages
- 0.9 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Air Conditioner
Goodman Mfg ARUF363616CA
10 pages 0.25 mb -
Air Conditioner
Goodman Mfg Light Commercial Self-Contained Packaged Heating & Cooling Unit
28 pages 0.57 mb -
Air Conditioner
Goodman Mfg energy-efficient air conditition
4 pages 0.66 mb -
Air Conditioner
Goodman Mfg ARUF303016CA
10 pages 0.25 mb -
Air Conditioner
Goodman Mfg 000 BTUH + 115 Volt
12 pages 0.9 mb -
Air Conditioner
Goodman Mfg AVPTC183014AA
6 pages 0.14 mb -
Air Conditioner
Goodman Mfg SS-CPH90-150
36 pages 1.4 mb -
Air Conditioner
Goodman Mfg High-Efficiency Split System Air Conditioner 1 To 5 Tons Up to 16 SEER
64 pages 0.8 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Goodman Mfg MSC/MSH 9. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Goodman Mfg MSC/MSH 9 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Goodman Mfg MSC/MSH 9 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Goodman Mfg MSC/MSH 9 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Goodman Mfg MSC/MSH 9
- nom du fabricant et année de fabrication Goodman Mfg MSC/MSH 9
- instructions d'utilisation, de réglage et d’entretien de l'équipement Goodman Mfg MSC/MSH 9
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Goodman Mfg MSC/MSH 9 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Goodman Mfg MSC/MSH 9 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Goodman Mfg en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Goodman Mfg MSC/MSH 9, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Goodman Mfg MSC/MSH 9, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Goodman Mfg MSC/MSH 9. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Important Safety Instructions The following symbols and labels are used throughout this manual to indicate immediate or potential safety hazards. It is the owner’s and installer’s responsibility to read and comply with all safety information and instructions accompanying these symbols. Failure to heed safety information increases the risk of pe[...]
-
Page 2
2 CONTENTS Important Safety Instructions .............................................. 1 Shipping Inspection ............................................................ 1 Codes & Regulations ......................................................... 2 Installation Considerations ................................................. 2 Rooftop Insta[...]
-
Page 3
3 • Select a location where noise, vibration and hot dis- charged air will not be an issue. • Do not install where high frequency equipment is used (wireless equipment, welding machine, medical facility) as it may interfere with the unit’s operation. Rooftop Installations If it is necessary to install the outdoor unit on a roof structure, ens[...]
-
Page 4
4 NOTE: Install the mounting bracket and drill the holes in the wall according to the wall structure and the correspond- ing mounting points on the mounting bracket. (The mounting brackets vary according to the model.) Inco rrect o rie ntation of Inst al lat ion Pl ate Corr ect orienta tion of Inst al lat ion Pl ate Figure 4 4. Determine the hole p[...]
-
Page 5
5 Indoor Unit Installation 9. Pass the piping through the hole in the wall. 10 . Place the upper claw on the back of the indoor unit on the upper hook of the installation plate. Move the indoor unit from side to side to ensure it is securely mounted. (See Figure 10 ). NOTE: By placing cushioning material between the in- door unit and the wall, plac[...]
-
Page 6
6 1 H Figure 14A 2 W 1 W 2 Figure 14B MS* 9 & MS * 12 Ou tdo o r Un it Dimen sion s Inc hes /mm ( L1x Hx W1) L2 ( mm) W 2 ( mm) 30" x 23" x 11" 760 x 590 x 285 21" 530 11 1/ 2" 290 M oun tin g Di me n s ions Drain joint installation NOTE: Drain joints differ slightly according to the different outdoor units. Inspect you[...]
-
Page 7
7 2. Insert tube in flare tool to measurement “A” in chart. Flare tubing as shown in Figure 19. Make sure flare is free of burrs and completely formed to make a leak proof joint. NOTE: In order to avoid dropping burrs into the tubing, angle the end of the copper tube/pipe in a downward direction as you remove the burrs. Pi pe Rea mer Point down[...]
-
Page 8
8 IMPORTANT NOTES: • If there are safety issues concerning the power supply, the unit should not be connected until safety issues are resolved. • Ensure that the electrical power supply is sufficient to safely power and run the unit. • Power voltage should range for 90% - 110% of the rated voltage. • Main power switch and surge protector sh[...]
-
Page 9
9 T erminal s on the indoor un it L N S L N S Model A T er minals on t he i n d o or u ni t L N S Te r m i n a l s o n the outdoor un i t 1 ( L ) 2 ( N ) S L N Pow er sup pl y Model B 3. Secure the wire onto the control board with the cord clamp. 4. To prevent the ingress of water, form a loop of the con- nective wires as illustrated in the install[...]
-
Page 10
10 • When relocating the unit to another place, perform the evacuation using a vacuum pump. • Refrigerant added to the unit must be in liquid form. (Does not apply to units using R-22.) Safe Refrigerant Handling While these items will not cover every conceivable situation, they should serve as a useful guide. Refri ger ants are hea vier th an a[...]
-
Page 11
11 T est Running After completing the gas leak check at the flare nut connec- tions and electrical safety check, perform the test operation. • Ensure all tubing and wiring have been properly con- nected. • Make sure both the gas and liquid side service valves are fully open. 1. Connect the power; press the ON/OFF button on the re- mote control [...]
-
Page 12
12 Goodman Manufacturing Comp any , L.P . 5151 San Felipe, Suite 500, Houston, TX 77056 www .goodmanmfg.com © 201 1 Goodman Manufacturing Company , L.P .[...]